Search NASA⌕ Search

SEARCH · Search NASA

Results for “R value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Properties of the rotational bands in {sup 161}Er

High-spin states in {sup 161}Er have been studied experimentally using the {sup 150}Nd({sup 16}O,5n) reaction at a beam energy of 86 MeV. The 5/2{sup +}[642], 3/2{sup -}[521], and 11/2{sup -}[505] bands are extended up to high-spin states, and particularly the {alpha}=-1/2 branch of the ground state 3/2{sup -}[521] band is revised significantly. The relatively enhanced E1 transitions from the 3/2{sup -}[521] band to the 5/2{sup +}[642] band are observed. The band properties are analyzed within the framework of a triaxial particle-rotor model, and near-prolate shape and triaxial deformation are proposed to the 3/2{sup -}[521] and 5/2{sup +}[642] bands, respectively. Signature inversion occurs in the 3/2{sup -}[521] band after the band crossing in {sup 161}Er, and the systematics of the signature inversion associated with the 3/2{sup -}[521] configuration are discussed. By analyzing the properties of the relatively enhanced E1 transitions, it is found that the R(E1/E2) values show angular momentum dependence before the band crossing, and these enhanced E1 transitions could be attributed to octupole softness.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy distribution of massless particles on black hole backgrounds with generalized uncertainty principle

We derive new formulas for the spectral energy density and total energy density of massless particles in a general spherically symmetric static metric from a generalized uncertainty principle. Compared with blackbody radiation, the spectral energy density is strongly damped at high frequencies. For large values of r, the spectral energy density diminishes when r grows, but at the event horizon, the spectral energy density vanishes and therefore thermodynamic quantities near a black hole, calculated via the generalized uncertainty principle, do not require any cutoff parameter. We find that the total energy density can be expressed in terms of Hurwitz zeta functions. It should be noted that at large r (low local temperature), the difference between the total energy density and the Stefan-Boltzmann law is too small to be observed. However, as r approaches an event horizon, the effect of the generalized uncertainty principle becomes more and more important, which may be observable. As examples, the spectral energy densities in the background metric of a Schwarzschild black hole and of a Schwarzschild black hole plus quintessence are discussed. It is interesting to note that the maximum of the distribution shifts to higher frequencies when the quintessence equation of state parameter w decreases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU(3) symmetry breaking in decay constants and electromagnetic properties of pseudoscalar heavy mesons

In this paper, the decay constants and mean square radii of pseudoscalar heavy mesons are studied in the SU(3) symmetry breaking. Within the light-front framework, the ratios f{sub D{sub s}}/f{sub D} and f{sub B{sub s}}/f{sub B} are individually estimated using the hyperfine splittings in the D{sub (s)}*-D{sub (s)} and B{sub (s)}*-B{sub (s)} states and the light quark masses, m{sub s,q} (q=u, d), to extract the wave function parameter {beta}. The values f{sub D{sub s}}/f{sub D}=1.29{+-}0.07 and f{sub B{sub s}}/f{sub B}=1.32{+-}0.08 are obtained, which are not only chiefly determined by the ratio of light quark masses m{sub s}/m{sub q}, but also insensitive to the heavy quark masses m{sub c,b} and the decay constants f{sub D,B}. The dependence of f{sub B{sub c}}/f{sub B} on {Delta}M{sub B{sub cB{sub c*}}} with the varied charm quark masses is also shown. In addition, the mean square radii are estimated as well. The values {radical}(<r{sub D{sub s}{sup +2}>/<r{sub D}{sup +2}>)=0.740{sub +0.050}{sup -0.041} and {radical}(<r{sub B{sub s}{sup 02}>/<r{sub B}{sup 02}>)=0.711{sub +0.058}{sup -0.049} are obtained, and the sensitivities of <r{sub P}{sup 2}> on the heavy and light quark masses are similar to those of the decay constants.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge radii of neutron deficient Fe 52 , 53 produced by projectile fragmentation

Bunched-beam collinear laser spectroscopy is performed on neutron deficient 52,53 Fe prepared through in-flight separation followed by a gas stopping. This novel scheme is a major step to reach nuclides far from the stability line in laser spectroscopy. Differential mean-square charge radii δ$\langle$r 2 $\rangle$ of 52,53 Fe are determined relative to stable 56 Fe as δ$\langle$r2$\rangle$ 56,52 =$-$0.034(13) fm 2 and δ$\langle$r 2 $\rangle$56,53=$-$0.218(13) fm 2 , respectively, from the isotope shift of atomic hyperfine structures. The multiconfiguration Dirac-Fock method is used to calculate atomic factors to deduce δ$\langle$r 2 $\rangle$. The values of δ$\langle$r 2 $\rangle$ exhibit a minimum at the N=28 neutron shell closure. The nuclear density functional theory with Fayans and Skyrme energy density functionals is used to interpret the data. As a result, the trend of δ$\langle$r 2 $\rangle$ along the Fe isotopic chain results from an interplay between single-particle shell structure, pairing, and polarization effects and provides important data for understanding the intricate trend in the δ$\langle$r 2 $\rangle$ of closed-shell Ca isotopes

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tidal Deformabilities and Radii of Neutron Stars from the Observation of GW170817

In this study, we use gravitational-wave observations of the binary neutron star merger GW170817 to explore the tidal deformabilities and radii of neutron stars. We perform a Bayesian parameter estimation with the source location and distance informed by electromagnetic observations. We also assume that the two stars have the same equation of state; we demonstrate that, for stars with masses comparable to the component masses of GW170817, this is effectively implemented by assuming that the stars’ dimensionless tidal deformabilities are determined by the binary’s mass ratio q by Λ 1 /Λ 2 = q 6 . We investigate different choices of prior on the component masses of the neutron stars. We find that the tidal deformability and 90% credible interval is ˜Λ = 222$+420\atop{-138}$ for a uniform component mass prior, ˜Λ = 245$+453\atop{-151}$ for a component mass prior informed by radio observations of Galactic double neutron stars, and ˜Λ = 233$+448\atop{-144}$ for a component mass prior informed by radio pulsars. We find a robust measurement of the common areal radius of the neutron stars across all mass priors of 8.9 ≤ $\hat{R}$ ≤ 13.2 km , with a mean value of <$\hat{R}$> = 10.8 km . Finally, our results are the first measurement of tidal deformability with a physical constraint on the star’s equation of state and place the first lower bounds on the deformability and areal radii of neutron stars using gravitational waves.

79 ASTRONOMY AND ASTROPHYSICS↗

Antiferro- and metamagnetism in the S = 7 / 2 hollandite analog Eu Ga 2 Sb 2

Recent work analyzing the impact of nonsymmorphic symmetries on electronic states has given rise to the discovery of multiple types of topological matter. Here we report the single-crystal synthesis and magnetic properties of Eu Ga 2 Sb 2 , a Eu-based antiferromagnet structurally consisting of pseudo-1D chains of Eu ions related by a nonsymmorphic glide plane. Here we find the onset of antiferromagnetic order at T N = 8K. Above T N the magnetic susceptibility is isotropic. Curie-Weiss analysis suggests competing ferromagnetic and antiferromagnetic interactions, with p eff = 8.1 μ B as expected for 4f 7 J = S = 7/2 Eu 2+ ions. Below T N and at low applied magnetic fields, an anisotropy develops linearly, reaching χ ⊥ /χ ∥ = 6 at T = 2K. There is concomitant metamagnetic behavior along χ ∥ , with a magnetic field of μ 0 H ≈ 0.5 T sufficient to suppress the anisotropy. Independent of crystal orientation, there is a continuous evolution to a field-polarized paramagnetic state with M = 7μ B /Eu 2+ at μ 0 H = 2 T as T → 0 K. Specific-heat measurements show a recovered magnetic entropy of ΔS mag ≈ 16.4 Jmol –1 K –1 from T ~ 0 K to T = T N , close to the expected value of R ln(8) for an S = 7/2 ion, indicating negligible low-dimensional spin fluctuations above T N . We find no evidence of unusual behaviors arising either from the dimensionality or the presence of the nonsymmorphic symmetries.

1-dimensional spin chains↗

Evaluation of models determined by neutron diffraction and proposed improvements to their validation and deposition

The Protein Data Bank (PDB) contains a growing number of models that have been determined using neutron diffraction or a hybrid method that combines X-ray and neutron diffraction. The advantage of neutron diffraction experiments is that the positions of all atoms can be determined, including H atoms, which are hardly detectable by X-ray diffraction. This allows the determination of protonation states and the assignment of H atoms to water molecules. Because neutrons are scattered differently by hydrogen and its isotope deuterium, neutron diffraction in combination with H/D exchange can provide information on accessibility, dynamics and chemical lability. In this study, the deposited data, models and model-to-data fit for all PDB entries that used neutron diffraction as the source of experimental data have been analysed. In many cases, the reported R work and R free values were not reproducible. In such cases, the model and data files were analysed to identify the reasons for this mismatch. The issues responsible for the discrepancies are summarized and explained. The analysis unveiled limitations to the annotation, deposition and validation of models and data, and a lack of community-wide accepted standards for the description of neutron models and data, as well as deficiencies in current model refinement tools. Most of the issues identified concern the handling of H atoms. Since the primary use of neutron macromolecular crystallography is to locate and directly visualize H atoms, it is important to address these issues, so that the deposited neutron models allow the retrieval of the maximum amount of information with the smallest effort of manual intervention. A path forward to improving the annotation, validation and deposition of neutron models and hybrid X-ray and neutron models is suggested.

59 BASIC BIOLOGICAL SCIENCES↗

Impedance-Aware Graph Convolutional Networks for Voltage Estimation in Active Distribution Networks

Voltage estimation plays a key role in ensuring the effective control and reliability of distribution networks. However, traditional machine learning methods often fail to capture the details of the distribution network’s topology. To overcome this challenge, graph convolutional networks (GCN) have emerged as an alternative. Graph convolutional networks inherently capture the topology of the grid, utilizing correlations to achieve precise voltage estimation. Other machine learning models and conventional GCNs fail to account for the distribution line characteristics found in the real world, limiting their effectiveness. This paper proposes an advanced variant of GCN called the Impedance-Aware Graph Convolutional Network (IA-GCN). The IA-GCN layer incorporates the magnitude of the impedance into the graph convolution mechanism, allowing it to capture topological nuances and provide valuable insights into node interrelationships by considering impedance as an intrinsic dimension. The performance of the IA-GCN layer is then compared with that of GCN and GraphSAGE layers through a surrogate model for voltage estimation. The performance analysis demonstrates that IA-GCN outperforms GCN by reducing the MAE by 87.55% and improving the R-squared value by 98%.

Ravi, Abhijith↗

Optimized Machine Learning Model for Predicting Groundwater Contamination

The use of physical models to predict groundwater contaminant movement remains technically challenging due to the complexity of the phenomena, the heterogeneity of key parameters in nature, and the presence of poorly defined interactive and feedback processes. New approaches to address these challenges are needed. In this study, we evaluate various Artificial Intelligence (AI)-based approaches to understand a hexavalent chromium (Cr(VI)) plumes located on the U.S. Department of Energy’s (DOE) Hanford Site in Richland, WA. The groundwater monitoring dataset used in this study included data from the 100 Area along the Columbia River and included data collected between 2010 to 2019. This study investigates the most prominent contaminant, Cr(VI), with the Extreme Gradient Boosting (XGBoost) machine learning model. The XGBoost models were compared with optimized versions using an Empirical Bayes Search Cross-Validation technique for better prediction. The optimized XGBoost model yielded an R^2 value of 0.99 on the training set and 0.85 on the testing set, whereas XGBoost without optimization yielded a value of 0.83 on the training set and 0.85 on the testing set. This paper provides an overview of a computational method for groundwater contamination modeling that shows promise for improving current remediation efforts.

Mazumdar, Hirak↗

Continental Scale Hydrostratigraphy: Comparing Geologically Informed Data Products to Analytical Solutions

Abstract This study synthesizes two different methods for estimating hydraulic conductivity (K) at large scales. We derive analytical approaches that estimate K and apply them to the contiguous United States. We then compare these analytical approaches to three‐dimensional, national gridded K data products and three transmissivity (T) data products developed from publicly available sources. We evaluate these data products using multiple approaches: comparing their statistics qualitatively and quantitatively and with hydrologic model simulations. Some of these datasets were used as inputs for an integrated hydrologic model of the Upper Colorado River Basin and the comparison of the results with observations was used to further evaluate the K data products. Simulated average daily streamflow was compared to daily flow data from 10 USGS stream gages in the domain, and annually averaged simulated groundwater depths are compared to observations from nearly 2000 monitoring wells. We find streamflow predictions from analytically informed simulations to be similar in relative bias and Spearman's rho to the geologically informed simulations. R ‐squared values for groundwater depth predictions are close between the best performing analytically and geologically informed simulations at 0.68 and 0.70 respectively, with RMSE values under 10 m. We also show that the analytical approach derived by this study produces estimates of K that are similar in spatial distribution, standard deviation, mean value, and modeling performance to geologically‐informed estimates. The results of this work are used to inform a follow‐on study that tests additional data‐driven approaches in multiple basins within the contiguous United States.

54 ENVIRONMENTAL SCIENCES↗

On the wall perturbation correction for a parallel-plate NACP-02 chamber in clinical electron beams

Purpose: In recent years, several Monte Carlo studies have been published concerning the perturbation corrections of a parallel-plate chamber in clinical electron beams. In these studies, a strong depth dependence of the relevant correction factors (p{sub wall} and p{sub cav}) for depth beyond the reference depth is recognized and it has been shown that the variation with depth is sensitive to the choice of the chamber's effective point of measurement. Recommendations concerning the positioning of parallel-plate ionization chambers in clinical electron beams are not the same for all current dosimetry protocols. The IAEA TRS-398 as well as the IPEM protocol and the German protocol DIN 6800-2 interpret the depth of measurement within the phantom as the water equivalent depth, i.e., the nonwater equivalence of the entrance window has to be accounted for by shifting the chamber by an amount {Delta}z. This positioning should ensure that the primary electrons traveling from the surface of the water phantom through the entrance window to the chamber's reference point sustain the same energy loss as the primary electrons in the undisturbed phantom. The objective of the present study is the determination of the shift {Delta}z for a NACP-02 chamber and the calculation of the resulting wall perturbation correction as a function of depth. Moreover, the contributions of the different chamber walls to the wall perturbation correction are identified. Methods: The dose and fluence within the NACP-02 chamber and a wall-less air cavity is calculated using the Monte Carlo code EGSnrc in a water phantom at different depths for different clinical electron beams. In order to determine the necessary shift to account for the nonwater equivalence of the entrance window, the chamber is shifted in steps {Delta}z around the depth of measurement. The optimal shift {Delta}z is determined from a comparison of the spectral fluence within the chamber and the bare cavity. The wall perturbation correction is calculated as the ratio between doses for the complete chamber and a wall-less air cavity. Results: The high energy part of the fluence spectra within the chamber strongly varies even with small chamber shifts, allowing the determination of {Delta}z within micrometers. For the NACP-02 chamber a shift {Delta}z=-0.058 cm results. This value is independent of the energy of the primary electrons as well as of the depth within the phantom and it is in good agreement with the value recommended in the German dosimetry protocol. Applying this shift, the calculated wall perturbation correction as a function of depth is varying less than 1% from zero up to the half value depth R{sub 50} for electron energies in the range of 6-21 MeV. The remaining depth dependence can mainly be attributed to the scatter properties of the entrance window. When neglecting the nonwater equivalence of the entrance window, the variation of p{sub wall} with depth is up to 10% and more, especially for low electron energies. Conclusions: The variation of the wall perturbation correction for the NACP-02 chamber in clinical electron beams strongly depends on the positioning of the chamber. Applying a shift {Delta}z=-0.058 cm toward the focus ensures that the primary electron spectrum within the chamber bears the largest resemblance to the fluence of a wall-less cavity. Hence, the influence of the chamber walls on the perturbation correction can be separated out and the residual variation of p{sub wall} with depth is minimized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-342: Use of Patient Geometry Measurements to Predict Dosimetric Gain with VMAT Over 3D for Chestwall and Regional Nodal Radiation

Purpose: To predict the dosimetric gain of VMAT over 3D for the treatment ofchestwall/IMN/supraclavicular nodes using geometric parameters acquired during simulation Methods: CT scans for 20 left and 20 right sided patients were retrospectively analyzed toobtain percent ipsilateral lung volume included in the PWT and supraclavicular fields, central lung depth (CLD), maximum lung depth (MLD), separation, chestwall concavity (defined here as the product of CLD and separation) and the maximum heart depth (MHD). VMAT, PWT and P/E plans were done for each case. The ipsilateral lung V20 Gy and mean, total lung V20 Gy and mean, heart V25 Gy and mean were noted for each plan. Correlation coefficients were obtained and linear regression models were built using data from the above training set of patients and then tested on 4 new patients. Results: The decrease in ipsilateral lung V20 Gy, total lung V20 Gy, ipsilateral lung mean and total lung mean with VMAT over PWT significantly (p<0.05) correlated with the percent volume of ipsilateral lung included in the PWT and supraclavicular fields with correlation coefficient values of r = 0.83, r = 0.77, r = 0.78 and r = 0.75 respectively. Significant correlations were also found between MHD and the decrease in heart V25 Gy and mean of r = 0.77 and r = 0.67 respectively. Dosimetric improvement with VMAT over P/E plans showed no correlation to any of the geometric parameters investigated in this study. The dosimetric gain predicted for the 4 test cases by the linear regression models given their respective percent ipsilateral lung volumes fell within the 95% confidence intervals around the best regression fit. Conclusion: The percent ipsilateral lung volume appears to be a strong predictor of the dosimetric gain on using VMAT over PWT apriori.

60 APPLIED LIFE SCIENCES↗

SU-C-304-05: Use of Local Noise Power Spectrum and Wavelets in Comprehensive EPID Quality Assurance

Purpose: As EPIDs are increasingly used for IMRT QA and real-time treatment verification, comprehensive quality assurance (QA) of EPIDs becomes critical. Current QA with phantoms such as the Las Vegas and PIPSpro™ can fail in the early detection of EPID artifacts. Beyond image quality assessment, we propose a quantitative methodology using local noise power spectrum (NPS) to characterize image noise and wavelet transform to identify bad pixels and inter-subpanel flat-fielding artifacts. Methods: A total of 93 image sets including bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Quantitative metrics such as modulation transform function (MTF), NPS and detective quantum efficiency (DQE) were computed for each image set. Local 2D NPS was calculated for each subpanel. A 1D NPS was obtained by radial averaging the 2D NPS and fitted to a power-law function. R-square and slope of the linear regression analysis were used for panel performance assessment. Haar wavelet transformation was employed to identify pixel defects and non-uniform gain correction across subpanels. Results: Overall image quality was assessed with DQE based on empirically derived area under curve (AUC) thresholds. Using linear regression analysis of 1D NPS, panels with acceptable flat fielding were indicated by r-square between 0.8 and 1, and slopes of −0.4 to −0.7. However, for panels requiring flat fielding recalibration, r-square values less than 0.8 and slopes from +0.2 to −0.4 were observed. The wavelet transform successfully identified pixel defects and inter-subpanel flat fielding artifacts. Standard QA with the Las Vegas and PIPSpro phantoms failed to detect these artifacts. Conclusion: The proposed QA methodology is promising for the early detection of imaging and dosimetric artifacts of EPIDs. Local NPS can accurately characterize the noise level within each subpanel, while the wavelet transforms can detect bad pixels and inter-subpanel flat fielding artifacts.

60 APPLIED LIFE SCIENCES↗

SU-F-T-43: Prediction of Dose Increments by Brain Metastases Resection Cavity Shrinkage Model with I-125 and Cs-131 LDR Seed Implantations

Purpose: This work aims to determine dose variability via a brain metastases resection cavity shrinkage model (RC-SM) with I-125 or Cs-131 LDR seed implantations. Methods: The RC-SM was developed to represent sequential volume changes of 95 consecutive brain metastases patients. All patients underwent serial surveillance MR and change in cavity volume was recorded for each patient. For the initial resection cavity, a prolate-ellipsoid cavity model was suggested and applied volume shrinkage rates to correspond to 1.7, 3.6, 5.9, 11.7, and 20.5 months after craniotomy. Extra-ring structure (6mm) was added on a surface of the resection volume and the same shrinkage rates were applied. Total 31 LDR seeds were evenly distributed on the surface of the resection cavity. The Amersham 6711 I-125 seed model (Oncura, Arlington Heights, IL) and the Model Cs-1 Rev2 Cs-131 seed model (IsoRay, Richland, WA) were used for TG-43U1 dose calculation and in-house-programed 3D-volumetric dose calculation system was used for resection cavity rigid model (RC-RM) and the RC-SM dose calculation. Results: The initial resection cavity volume shrunk to 25±6%, 35±6.8%, 42±7.7%, 47±9.5%, and 60±11.6%, with respect to sequential MR images post craniotomy, and the shrinkage rate (SR) was calculated as SR=56.41Xexp(−0.2024Xt)+33.99 and R-square value was 0.98. The normal brain dose as assessed via the dose to the ring structure with the RC-SM showed 29.34% and 27.95% higher than the RC-RM, I-125 and Cs-131, respectively. The dose differences between I-125 and Cs-131 seeds within the same models, I-125 cases were 9.17% and 10.35% higher than Cs-131 cases, the RC-RM and the RC-SM, respectively. Conclusion: A realistic RC-SM should be considered during LDR brain seed implementation and post-implement planning to prevent potential overdose. The RC-SM calculation shows that Cs-131 is more advantageous in sparing normal brain as the resection cavity volume changes with the LDR seeds implementation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-554: Dark Current Effect On CyberKnife Beam Dosimetry

Purpose: All RF linear accelerators produce dark current to varying degrees when an accelerating voltage and RF input is applied in the absence of electron gun injection. This study is to evaluate how dark current from the linear accelerator of CyberKnife affect the dose in the reference dosimetry. Methods: The G4 CyberKnife system with 6MV photon beam was used in this study. Using the ion chamber and the diode detector, the dose was measured in water with varying time delay between acquiring charges and staring beam-on after applying high-voltage into the linear accelerator. The dose was measured after the time delay with over the range of 0 to 120 seconds in the accelerating high-voltage mode without beam-on, applying 0, 10, 50, 100, and 200 MUs. For the measurements, the collimator of 60 mm was used and the detectors were placed at the depths of 10 cm with the source-to-surface distance of 80 cm. Results: The dark current was constant over time regardless of MU. The dose due to the dark current increased over time linearly with the R-squared value of 0.9983 up to 4.4 cGy for the time 120 seconds. In the dose rate setting of 720 MU/min, the relative dose when applying the accelerating voltage without beam-on was increased over time up to 0.6% but it was less than the leakage radiation resulted from the accelerated head. As the reference dosimetry condition, when 100 MU was delivered after 10 seconds time delay, the relative dose increased by 0.7% but 6.7% for the low MU (10 MU). Conclusion: In the dosimetry using CyberKnife system, the constant dark current affected to the dose. Although the time delay in the accelerating high-voltage mode without beam-on is within 10 seconds, the dose less than 100 cGy can be overestimated more than 1%.

07 ISOTOPE AND RADIATION SOURCES↗

Influence of surface tension on nuclear collective properties

Rigidities of even-even nuclei were estimated and compared with nuclear charge radii. Correlation of maximal nuclear rigidities with minimal values of r{sub 0} parameters was revealed. Influence of effective surface tension on nuclear properties was discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Occupation probabilities as variables in electronic structure theory: cooper pairing, OP-NSOFT-Cs,t, and the homogeneous electron liquid

The energy functional of a novel electronic structure theory, OP-NSOFT, has as variables the natural spin orbitals (NSO) of the trial function and their joint occupation probabilities in the search for the ground state energy. When occupancy is restricted to the spin-paired NSOs of DOCI, the resulting theory, OP-NSOFT-0, scales as M 3 , with M the size of the one-electron basis set. Accurate results were obtained for small molecules, particularly near dissociation where single reference theories like DFT are inaccurate. The homogeneous electron liquid (HEL) could serve as a test bed of OP-NSOFT for condensed systems, but OP-NSOFT-0 reduces to the Hartree–Fock approximation for the HEL. Cooper pairing is introduced instead, both singlet pairing, OP-NOFT-Cs, and fully polarized triplet pairing, OP-NSOFT-Ct. The former yields 1/3 of the diffusion-Monte-Carlo correlation energy, the latter 1/2 to 1/3 with decreasing electron density for r s values between 1 and 10. Both yield the discontinuity in the single-particle occupation number required by the Luttinger theorem. Furthermore, two-state joint occupation probabilities illustrate the importance of electron–electron small-angle scattering in establishing electron correlation in the unpolarized HEL.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Effect of Sulfuric Acid Anodization on the Electrochemical Properties of Aluminum Alloy AlSi 10 Mg Prepared by Selective Laser Melting

Aluminum alloy, AlSi 10 Mg, prepared by selective laser melt (SLM) fabrication was anodized in 9.8% sulfuric acid (Type II) at 15 V for a total of 23 min. Experiments were performed to study the potentiostatic anodization process and its effects on the oxide coating morphology, thickness, and electrochemical properties of the alloy. Prior to anodization, the alloy microstructure is composed of aluminum cells encapsulated in a silicon network. Anodizing the abraded and polished AlSi 10 Mg surface produced a porous oxide layer with a thickness of 5μm. The oxide coating weight was 698 ± 29 mg/ft 2 . The oxide coating forms in the aluminum cells that are isolated from one another by the silicon eutectic phase. In electrochemical tests, the anodic and cathodic potentiodynamic polarization currents were suppressed by factors of 15× and 215×, respectively, as compared to the unanodized controls. The data indicate the anodic oxide coating suppresses the cathodic more than the anodic reaction rate. Linear polarization resistance (R p ) values increased by 279× after anodization. The corrosion current density values (j corr ) decreased by 133× after anodization. Taken together, the electrochemical data indicate the anodic oxide coating (unsealed) increases the corrosion resistance of the SLM alloy by two orders of magnitude.

Electrochemistry↗