Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Response to Notice of Disapproval TA-63 Transuranic Waste Facility Permit Modification Request, Rev. 2, Los Alamos National Laboratory

This document responds to the August 30, 2012, New Mexico Environment Department- Hazardous Waste Bureau (NMED-HWB) Disapproval notice referenced above. The notice was issued for the Permit Modification Request for Technical Area 63, Transuranic Waste Facility, Hazardous Waste Container Storage Unit (PMR), Revision 2.0, submitted to NMED-HWB on July 13, 2012, by the United States Department of Energy (DOE) and Los Alamos National Security, LLC, collectively the Permittees. The Permittees are seeking to modify the Hazardous Waste Facility Permit (Permit) for Los Alamos National Laboratory (LANL) for approval of the construction of the Transuranic Waste Facility (TWF) at Technical Area 63 (TA-63) and permission to store hazardous waste there. This response may contain information regarding the management of radioactive materials, including source, special nuclear, and byproduct material. Information on radioactive materials and radionuclides, including the results of sampling and analysis of radioactive constituents, is voluntarily provided to NMED-HWB in accordance with DOE policy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Special Analysis for the Disposal of U.S. Department of Energy High Activity Cesium Sources Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

This special analysis evaluates whether the Lawrence Livermore National Laboratory (LLNL) U.S. Department of Energy (DOE) High Activity Cesium (Cs) Sources waste stream is suitable for shallow land burial at the Area 5 Radioactive Waste Management Site on the Nevada National Security Site. Disposal of the LLNL DOE High Activity Cs Sources waste meets all DOE M 435.1-1, “Radioactive Waste Management Manual,” Chapter IV, Section P performance objectives (DOE 1999). The LLNL DOE High Activity Cs Sources waste stream is recommended for acceptance with the conditions that 1) the total waste stream cesium-137 activity be limited to 1.7E16 Bq and 2) the waste be disposed 4.4 m (10 ft) below existing grade.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Special Analysis for the Disposal of the Neutron Products Incorporated Sealed Source Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

The purpose of this special analysis (SA) is to determine if the Neutron Products Incorporated (NPI) Sealed Sources waste stream (DRTK000000056, Revision 0) is suitable for disposal by shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS). The NPI Sealed Sources waste stream consists of 850 60Co sealed sources (Duratek [DRTK] 2013). The NPI Sealed Sources waste stream requires a special analysis (SA) because the waste stream 60Co activity concentration exceeds the Nevada National Security Site (NNSS) Waste Acceptance Criteria (WAC) Action Levels.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion source developments for the production of radioactive isotope beams at TRIUMF

At the ISAC facility at TRIUMF radioactive ions are produced by bombarding solid targets with up to 100 μA of 500 MeV protons. The reaction products have to diffuse out of the hot target into an ion source. Normally, singly charged ions are extracted. They can be transported either directly to experiments or via an ECR charge state breeder to a post accelerator. Several different types of ion sources have to be used in order to deliver a large variety of rare isotope beams. At ISAC those are surface ion sources, forced electron beam arc discharge (FEBIAD) ion sources and resonant laser ionization sources. Recent development activities concentrated on increasing the selectivity for the ionization to suppress isobaric contamination in the beam. Therefore, a surface ion rejecting resonant laser ionization source (SIRLIS) has been developed to suppress ions from surface ionization. For the FEBIAD ion source a cold transfer line has been introduced to prevent less volatile components from reaching the ion source.

43 PARTICLE ACCELERATORS↗

Nuclear Security Interface Considerations for Regaining Control of Discovered Nuclear and Radioactive Materials

Recognizing that regaining control of orphan radioactive and nuclear material is challenging, the international community has developed requirements and guidance to support countries in addressing the problem. However, limited guidance is available on the practical nuclear security related issues that arise when nuclear or other radioactive material out of regulatory control (MORC) is encountered and efforts are undertaken to regain control. For example, the IAEA Specific Safety Guide No. SSG-19, “National Strategy for Regaining Control over Orphan Sources and Improving Control over Vulnerable Sources”, provides recommendations on a methodology for establishing a national strategy for regaining control of orphan sources. However, except for Pu239 in radioactive sources, nuclear material is outside the scope of this safety guide, and practical safety and security measures below the level of national strategy are not discussed adequately.This paper discusses the interfaces between the stakeholder groups and the responsibilities of each when encountering common scenarios that deal with MORC transitioning to regulatory control. The stakeholders include but are not limited to individuals who encounter MORC, and providers of formal and informal transport systems, and traditional and ad hoc storage solutions. This paper explores practical legal, financial, and institutional issues that hinder implementation of required safety and security practices. This paper also offers strategies that can be implemented on the individual, organizational, national, and international level to regain control of MORC.

Shannon, Michael↗

Developing Source Term Database for Advanced Reactors

A source term database is crucial to informing nuclear emergency response measures, enabling emergency responders to assess the potential severity of nuclear and radiological consequences. In recent times, various advanced reactor designs have come into operation, are under construction, or are being designed and developed. This report documents an effort carried out to develop a source term database for advanced reactors. The report covers key design features of these reactors and discusses radioactivity buildup and source term inventories of dose-significant radionuclides in the reactor core. For neutronic and depletion analyses, we used the SCALE code system, a computational suite for reactor physics, depletion, criticality, and sensitivity/uncertainty quantification. We used SCALE/TRITON to perform depletion calculations to predict cycle length and discharge burnup and to generate the ORIGEN reactor library. Subsequently, we used SCALE/ORIGAMI to calculate radioactivity buildup and, thereby, the source term inventories at the targeted discharge burnup, using the ENDF/B-VII.1 nuclear data library. This report covers several advanced reactors, including the KLT-40S, RITM-200N, VOYGR, and eVinci. However, other reactors, such as the RITM-200S and ARC-100, have yet to be investigated and will be explored in future efforts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Special Analysis for the Disposal of U.S. Department of Energy High Activity Cesium Sources Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

This special analysis (SA) evaluates whether the Lawrence Livermore National Laboratory (LLNL) U.S. Department of Energy (DOE) High Activity Cesium (Cs) Sources waste stream (BCLADOEOSRPCS, Revision 0) is suitable for shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS) on the Nevada National Security Site (NNSS). Disposal of the LLNL DOE High Activity Cs Sources waste meets all U.S. Department of Energy (DOE) Manual DOE M 435.1-1, “Radioactive Waste Management Manual,” Chapter IV, Section P performance objectives (DOE 1999). The LLNL DOE High Activity Cs Sources waste stream is recommended for acceptance with the conditions that 1) the total waste stream cesium-137 ( 137 Cs) activity be limited to 1.7E16 becquerel (Bq) and 2) the waste be disposed greater than 4.4 meters (m) (14 feet [ft], 5 inches [in.]) below existing grade.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Special Analysis for the Disposal of the Lawrence Livermore National Laboratory Low Activity Beta/Gamma Sources Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

This special analysis (SA) evaluates whether the Lawrence Livermore National Laboratory (LLNL) Low Activity Beta/Gamma Sources waste stream (BCLALADOEOSRP, Revision 0) is suitable for disposal by shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site (NNSS). The LLNL Low Activity Beta/Gamma Sources waste stream consists of sealed sources that are no longer needed. The LLNL Low Activity Beta/Gamma Sources waste stream required a special analysis because cobalt-60 (60Co), strontium-90 (90Sr), cesium-137 (137Cs), and radium-226 (226Ra) exceeded the NNSS Waste Acceptance Criteria (WAC) Action Levels (U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office [NNSA/NFO] 2015). The results indicate that all performance objectives can be met with disposal of the LLNL Low Activity Beta/Gamma Sources in a SLB trench. The LLNL Low Activity Beta/Gamma Sources waste stream is suitable for disposal by SLB at the Area 5 RWMS. However, the activity concentration of 226Ra listed on the waste profile sheet significantly exceeds the action level. Approval of the waste profile sheet could potentially allow the disposal of high activity 226Ra sources. To ensure that the generator does not include large 226Ra sources in this waste stream without additional evaluation, a control is need on the maximum 226Ra inventory. A limit based on the generator’s estimate of the total 226Ra inventory is recommended. The waste stream is recommended for approval with the control that the total 226Ra inventory disposed shall not exceed 5.5E10 Bq (1.5 Ci).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tracking radioactivity content in the spent fuel pool in PWRS - 15150

Over the last decade, significant progress has been made in managing radioisotopes generated in the PWR primary systems. These include limiting the use of cobalt containing materials, along with improved fuel performance and zinc injection to passivate the corrosion layers to limit the accumulation of Co-58 and Co-60 on primary coolant surfaces. Attention here is directed to the spent fuel pool where accumulation of spent fuel and activated material represents a growing source of mobile radioactivity supplemented with periodic exchanges of water from the reactor cooling system. Characterization of this source is increasingly important to effective management of disposal options. This paper examines the radioactive resin source term as determined from routine sampling of the coolant and fuel pool liquids. Targeted resin stream sampling and radiochemical analyses conducted at Diablo Canyon serve to inform and provide context for this examination. This examination is supplemented with computer modelling using the DW James Consulting computer program, 3R-SCAN. At most operating plants daily reactor coolant samples are counted using gamma spectroscopy and recorded. These samples serve to track fuel performance and maintain water chemistry. A secondary use for this data is to maintain a day to day tracking of releases of radioisotopes important to waste disposal. Given the coolant concentrations, plant operating history, and corroborative mathematical models and sampling, accumulation of these radioisotopes in coolant cleanup system ion-exchangers can be predicted. Fuel pool sampling is less frequent, but at the same time, things change more slowly there. The fuel pool contains about ten times the volume of the reactor coolant but its cleanup system process rate is comparable to reactor coolant letdown, i.e. 5.047 - 8.833 liters per second [lps] (80-140 gallons per minute [gpm]). A spent fuel pool clean-up demineralizer flow rate is typically about 5.047 lps (80 gpm). Concentrations of longer lived radioisotopes in the spent fuel pool can be comparable to those in reactor coolant. Releases of corrosion products and fission products from the stored fuel occur at a low rate but given the overall inventory can be significant. Recognized scaling factor ratios, particularly those to Co-60, are skewed by the aging of the material in the pool. An additional consideration stems from refueling operations themselves. Prior to refueling, it is common practice to conduct a forced oxidation of the corrosion films within the reactor. This spikes the activity within the reactor coolant. Most of this activity is removed by the reactor coolant purification system prior to removing the reactor head. This paper examines the accumulation of activity in the fuel pool purification ion exchange resins and how it impacts the overall classification of those ion exchange resins. The following discussion focuses on the transport of nickel and cobalt isotopes particularly as it relates to determination of Ni-63 which has become increasingly prominent in disposal classification. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time dependence of energy spectra of brachytherapy sources and its impact on the half and the tenth value layers

Purpose: Several factors including radionuclide purity influence the photon energy spectra from sealed brachytherapy sources. The existence of impurities and trace elements in radioactive materials as well as the substrate and encapsulation may not only alter the spectrum at a given time but also cause change in the spectra as a function of time. The purpose of this study is to utilize a semiempirical formalism, which quantitatively incorporates this time dependence, to calculate and evaluate the shielding requirement impacts introduced by this time dependence for a {sup 103}Pd source. Methods: The formalism was used to calculate the NthVL thicknesses in lead for a {sup 103}Pd model 200 seed. Prior to 2005, the {sup 103}Pd in this source was purified to a level better than 0.006% of the total {sup 103}Pd activity, the key trace impurity consisting of {sup 65}Zn. Because {sup 65}Zn emits higher energy photons and has a much longer half-life of 244 days compared to {sup 103}Pd, its presence in {sup 103}Pd seeds led to a time dependence of the photon spectrum and other related physical quantities. This study focuses on the time dependence of the NthVL and the analysis of the corresponding shielding requirements. Results: The results indicate that the first HVL and the first TVL in lead steadily increased with time for about 200 days and then reached a plateau. The increases at plateau were more than 1000 times compared to the corresponding values on the zeroth day. The second and third TVLs in lead reached their plateaus in about 100 and 60 days, respectively, and the increases were about 19 and 2.33 times the corresponding values on the zeroth day, respectively. All the TVLs demonstrated a similar time dependence pattern, with substantial increases and eventual approach to a plateau. Conclusions: The authors conclude that the time dependence of the emitted photon spectra from brachytherapy sources can introduce substantial variations in the values of the NthVL with time if certain impurities are present. The contribution of {sup 65}Zn to the dose rate constant was less than 0.03% in the earlier {sup 103}Pd seeds, and because of the use of new processing technologies since 2005, this impurity has been essentially eliminated, as demonstrated in the measured spectra of current {sup 103}Pd model 200 seeds. This study illustrates the importance of performing photon spectroscopy of the manufactured radioactive sources as a quality assurance test for an assessment over time of both the radiation protection and the dosimetric properties.

07 ISOTOPE AND RADIATION SOURCES↗

Assessment on Transport of Radioactive Species from Nuclear Facilities - 17079

It is generally recognized that radioactive nuclides are most hazardous fission products that could be released in the event of reactor accidents. The reactor coolant system of a pressurized water reactor (PWR) nuclear plant exhibits radioactivity from various sources. These radiation sources consist of the fission products from fuel element and activated products from corrosion products. The complex infrastructure of the processes does not allow detailed measurement of activity until after the reactor is shutdown. All of the components that require dismantling will be radioactive which was caused by neutron activation during operation, contamination by corrosion products, contamination by damaged by fuel rods and leaks by equipment. Due mainly to the various operation modes and their aging, there are the increasing needs to carry out repair works that are not sufficiently provided for by the original design. Many difficulties are involved in these tasks, namely, high radiation doses, cramped areas, hard to reach components, coupled with stringent quality conditions. The need to simulate the behavior of corrosion products in a nuclear power plant environment has attracted many researchers' attention. It has performed the in-depth reviews of the various theories and physics associated with the corrosion products transportation, the laboratory loop testing, and the field measurements in operating plants. Before we start the decommissioning of nuclear power plants, workers, the public and the environment shall be properly protected from radiation hazards. For this purpose, a safety assessment should be carried out relating to the potential hazards that may occur during the decommissioning. The radiological hazards involved in the decommissioning activities also should be identified, and be taken into account in the safety assessment. The radiation conditions of the primary circuit are determined by the activity of corrosion and fission products that have accumulated on the internal surfaces of the components. Therefore the estimation of contamination on the components is very important and, may be the first step in the reactor operation and decommissioning of components. The predominant radionuclide in the PWR primary coolant is Co-60, although Co-58 contributes significantly to radioactivity level at the early stage of a reactor operation. Since Co-60 is produced from the in-core Co-58, which is the source of cobalt in a reactor coolant system, many researchers have investigated its transmutation in the core, its transport around the system, and its subsequent deposition on surfaces. The major parameter influencing the behavior of radioactivity, such as Co-60 in the coolant, is the corrosion product oxides. The objective of this work is to analyze the corrosion product activity transported in the primary circuit by using a multi-region model. This model, which is incorporated with the mass and activity transport between the dissolved corrosion products in the coolant and the surface, describes the specific activity of corrosion products in coolant and on the surfaces according to the operation modes as well as decommissioning stage. In order to evaluate the analysis of the corrosion products in an integral type reactor, a multi-region mass balance model is applied. The specific activities of the various species on the surface of core and steam generator throughout the effective full power hours, 15,000 hours, are simulated for the various modes of operations. As a result, the specific activities of corrosion products from the surface of primary circuit were shown as very low compared to those of other commercial nuclear power plants. In this simulated reactor, a significant reduction of specific activities from the activated corrosion products is obtained due to the introduction of titanium alloy to the steam generator tube and the avoidance of boric acid induced corrosion. From this result we conclude that we are able to predict the level of radioactive nuclides generated by corrosion products in a primary circuit according to the various modes of operations by using multi-region model. In this point of view it is concluded that this multi-region model can be used as an engineering tool for analysis of the corrosion products within the primary coolant for the nuclear power plants. It is also considered that it is possible to extend to a calculation tool for estimating the radiological hazards involved in the decommissioning activities in terms of safety assessment. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

A simple radionuclide-driven single-ion source

We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating {sup 148}Gd onto a silicon {alpha}-particle detector and vapor depositing a layer of BaF{sub 2} over it. {sup 144}Sm recoils from the alpha decay of {sup 148}Gd are used to dislodge Ba{sup +} ions from the BaF{sub 2} layer and emit them in the surrounding environment. The simultaneous detection of an {alpha} particle in the substrate detector allows for tagging of the nuclear decay and of the Ba{sup +} emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(U) Using the MCNP6 Perturbation Capability for Source Nuclide Density Sensitivities

The Taylor series (differential operator) perturbation method, as implemented in the PERT capability in MCNP6 (Ref. 1), can be used for first- and second-order sensitivity analyses in fixed-source problems. Unfortunately, the PERT capability does not yet work with point-detector (F5) or pulse-height (F8) tallies. Also, the second-order Taylor series term lacks the cross terms that would allow the calculation of mixed sensitivities. Finally, the PERT capability does not compute any sensitivities involving the source in a fixed-source problem. When neutrons or gamma rays are emitted due to radioactive decay, the source rate density depends intrinsically on the nuclide densities in the source material. When the PERT capability in MCNP6 is used to compute sensitivities of a response to nuclide and material densities, those sensitivities do not include the effect of the source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sealed source peer review plan

Sealed sources are known quantities of radioactive materials that have been encapsulated in quantities that produce known radiation fields. Sealed sources have multiple uses ranging from instrument calibration sources to sources that produce radiation fields for experimental applications. The Off-Site Source Recovery (OSR) Project at Los Alamos National Laboratory (LANL), created in 1999, under the direction of the Waste Management Division of the U.S. Department of Energy (DOE) Albuquerque has been assigned the responsibility to recover and manage excess and unwanted radioactive sealed sources from the public and private sector. LANL intends to ship drums containing qualified sealed sources to the Waste Isolation Pilot Plant (WIPP) for disposal. Prior to shipping, these drums must be characterized with respect to radiological content and other parameters. The U. S. Environmental Protection Agency (EPA) requires that ten radionulcides be quantified and reported for every container of waste to be disposed in the WIPP. The methods traditionally approved by the EPA include non-destructive assay (NDA) in accordance with Appendix A of the Contact-Handled Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (DOE, 2002) (CH WAC). However, because of the nature and pedigree of historical records for sealed sources and the technical infeasibility of performing NDA on these sources, LANL proposes to characterize the content of these waste drums using qualified existing radiological data in lieu of direct measurement. This plan describes the process and documentation requirements for the use of the peer review process to qualify existing data for sealed radiological sources in lieu of perfonning radioassay. The peer review process will be performed in accordance with criteria provided in 40 CFR {section} 194.22 which specifies the use of the NUREG 1297 guidelines. The plan defines the management approach, resources, schedule, and technical requirements for the subject peer review.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Testing claims of the GW170817 binary neutron star inspiral affecting β-decay rates

On August 17, 2017, the first gravitational wave signal from a binary neutron star inspiral (GW170817) was detected by Advanced LIGO and Advanced VIRGO. Here we present radioactive β-decay rates of three independent sources 44 Ti, 60 Co and 137 Cs, monitored during the same period by a precision experiment designed to investigate the decay of long-lived radioactive sources. We do not find any significant correlations between decay rates in a 5 h time interval following the GW170817 observation. This contradicts a previous claim published in this journal of an observed 2.5σ Pearson Correlation between fluctuations in the number of observed decays from two β-decaying isotopes ( 32 Si and 36 Cl) in the same time interval. By correcting for the choice of an arbitrary time interval, we find no evidence of a correlation above 1.5σ confidence. In addition, we argue that such analyses on correlations in arbitrary time intervals should always correct for the so-called Look-Elsewhere effect by quoting the global significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of source-production revision on the dose-rate constant of {sup 131}Cs interstitial brachytherapy sources

Purpose: Since its introduction in 2004, the model CS-1 Rev.1 {sup 131}Cs source has been used in many radiation therapy clinics for prostate brachytherapy. In 2006, this source model underwent a Rev.2 production revision. The aim of this work was to investigate the dosimetric influences of the Rev.2 production revision using high-resolution photon spectrometry. Methods: Three CS-1 Rev.1 and three CS-1 Rev.2 {sup 131}Cs sources were used in this study. The relative photon energy spectrum emitted by each source in the transverse bisector of the source was measured using a high-resolution germanium detector designed for low-energy photon spectrometry. Based on the measured photon energy spectrum and the radioactivity distribution in the source, the dose-rate constant ({Lambda}) of each source was determined. The effects of the Rev.2 production revision were quantified by comparing the emitted photon energy spectra and the {Lambda} values determined for the sources manufactured before and after the production revision. Results: The relative photon energy spectrum originating from the principal emissions of {sup 131}Cs was found to be nearly identical before and after the Rev.2 revision. However, the portion of the spectrum originating from the production of fluorescent x rays in niobium, a trace element present in the source construction materials, was found to differ significantly between the Rev.1 and Rev.2 sources. The peak intensity of the Nb K{sub {alpha}} and Nb K{sub {beta}} fluorescent x rays from the Rev.2 source was approximately 35% of that from the Rev.1 source. Consequently, the nominal {Lambda} value of the Rev.2 source was found to be greater than that determined for the Rev.1 source by approximately 0.7%{+-}0.5%. Conclusions: A significant reduction (65%) in relative niobium fluorescent x-ray yield was observed in the Rev.2 {sup 131}Cs sources. The impact of this reduction on the dose-rate constant was found to be small, with a relative difference of less than 1%. This study demonstrates that photon spectrometry can be used as a sensitive and convenient tool for monitoring and for quantifying the dosimetric effects of brachytherapy source-production revisions. Because production revision can change both the geometry and the atomic composition of brachytherapy sources, its dosimetric impact should be carefully monitored and evaluated for each production revision.

60 APPLIED LIFE SCIENCES↗