Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Back-side readout semiconductor photomultiplier

This disclosure provides systems, methods, and apparatus related to semiconductor photomultipliers. In one aspect, a device includes a p-type semiconductor substrate, the p-type semiconductor substrate having a first side and a second side, the first side of the p-type semiconductor substrate defining a recess, and the second side of the p-type semiconductor substrate being doped with n-type ions. A conductive material is disposed in the recess. A p-type epitaxial layer is disposed on the second side of the p-type semiconductor substrate. The p-type epitaxial layer includes a first region proximate the p-type semiconductor substrate, the first region being implanted with p-type ions at a higher doping level than the p-type epitaxial layer, and a second region disposed on the first region, the second region being doped with p-type ions at a higher doping level than the first region.

42 ENGINEERING↗

Commissioning of the Mu2e Data AcQuisition System and the Vertical Slice Test of the Straw Tracker

The report discusses the commissioning of the DAQ system of the Mu2e experiment. We studied how the tracker works and especially the tracker readout. We used a generator to send pulses and we tried to understand the output and non-output of the DTC, in order to validate the event and run format and all the failure modes. In section one, we describe Charged Lepton Flavour Violation, the main purpose of Mu2e, in section two we describe Mu2e experiment. Section three presents the tracker description and readout, meanwhile section four the DAQ system and event building. In section five, we start explaining the analysis we have done on events and all the failure modes we discovered. In section six, we have done an analysis of the logger and boardreader rate, we validated the generator frequency in section seven and studied the number of hits in function of the channel number in section eight. To conclude we investigated the channel to channel time differences in section nine and in section ten we explain our Monte Carlo simulation, reproducing ROCs readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wide field imaging of solar system objects with an 8192 x 8192 CCD mosaic

As part of this program, we successfully completed the construction of the world's largest CCD camera, an 8192 x 8192 CCD mosaic. The system employs 8 2K x 4K 3-edge buttable CCDs arranged in a 2 x 4 chip mosaic. The focal plane has small gaps (less than 1 mm) between mosaic elements and measures over 120 mm x 120 mm. The initial set of frontside illuminated CCDs were developed with Loral-Fairchild in a custom foundry run. The initial lots yielded of order 20 to 25 functional devices, of which we selected the best eight for inclusion for the camera. We have designed a custom 3-edge-buttable package that ensures the CCD dies are mounted flat to plus or minus 10 microns over the entire area of the mosaic. The mosaic camera system consists of eight separate readout signal chains controlled by two independent DSP microcontrollers. These are in turn interfaced to a Sun Sparc-10 workstation through two high speed fiber optic interfaces. The system saw first-light on the Canada-France-Hawaii Telescope on Mauna Kea in March 1995. First-light on the University of Hawaii 2.2-M Telescope on Mauna Kea was in July 1995. Both runs were quite successful. A sample of some of the early science from the first light run is reported in the publication, 'Observations of Weak Lensing in Clusters with an 8192 x 8192 CCD Mosaic Camera'.

Hall, Donald N. B.↗

High Pressure Sensing and Dynamics Using High Speed Fiber Bragg Grating Interrogation Systems

Fiber Bragg gratings (FBGs) are developing into useful sensing tools for measuring high pressure dynamics in extreme environments under shock loading conditions. Approaches using traditional diode array coupled FBG interrogation systems are often limited to readout speeds in the sub-MHz range. For shock wave physics, required detection speeds approaching 100 MHz are desired. We explore the use of two types of FBG sensing systems that are aimed at applying this technology as embedded high pressure probes for transient shock events. Both approaches measure time resolved spectral shifts in the return light from short (few mm long) uniform FBGs at 1550 nm. In the first approach, we use a fiber coupled spectrometer to demultiplex spectral channels into an array (up to 12) of single element InGaAs photoreceivers. By monitoring the detectors during a shock impact event with high speed recording, we are able to track the pressure induced spectral shifting in FBG down to a time resolution of 20 ns. In the second approach, developed at the Special Technologies Lab, a coherent mode-locked fiber laser is used to illuminate the FBG sensor. After the sensor, wavelength-to-time mapping is accomplished with a chromatic dispersive element, and entire spectra are sampled using a single detector at the modelocked laser repetition rate of 50 MHz. By sampling with a 12 GHz InGaAs detector, direct wavelength mapping in time is recorded, and the pressure induced FBG spectral shift is sampled at 50 MHz. Here, the sensing systems are used to monitor the spectral shifts of FBGs that are immersed into liquid water and shock compressed using explosives. In this configuration, the gratings survive to pressures approaching 50 kbar. We describe both approaches and present the measured spectral shifts from the shock experiments.

fiber Bragg grating sensors, shockwave diagnostics↗

Cooling the Dark Energy Camera CCD Array using a Closed-Loop, Two-Phase Liquid Nitrogen system

The Dark Energy Camera (DECam) is the new wide field prime-focus imager for the Blanco 4m telescope at CTIO. This instrument is a 3 sq. deg. camera with a 45 cm diameter focal plane consisting of 62 2k x 4k CCDs and 12 2k x 2k CCDs and was developed for the Dark Energy Survey that will start operations at CTIO in 2011. The DECam CCD array is inside the imager vessel. The focal plate is cooled using a closed loop liquid nitrogen system. As part of the development of the mechanical and cooling design, a full scale prototype imager vessel has been constructed and is now being used for Multi-CCD readout tests. The cryogenic cooling system and thermal controls are described along with cooling results from the prototype camera. The cooling system layout on the Blanco telescope in Chile is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An 82 to 84 percent efficient, small size, 2 and 4 stage depressed collector for octave bandwidth high performance TWT's

Improvements were carried out on a TWT (traveling wave tube) for use in EMC (electronic countermeasure) systems by applying MDC (multi-stage depressed collector) and spent-beam refocusing techniques. The MDC geometric design consists of six collecting elements (electrodes) at ground and cathode potentials operating in 2 or 4 stage configuration. The refocusing system designed allows a controlled beam expansion to the point that space charge becomes negligible at the MDC entrance. Simultaneously, the standard deviation of the radial velocity (angular spread) is reduced. This system provides an analog real time readout of P(recovered). Data on all tests is obtained with an automated data acquisition system.

Kosmahl, H.↗

Multi-purpose γ-Ray Interface to Auxiliary Detectors (MyRIAD) User Manual

The MyRIAD (Multipurpose γ-Ray Interface to Auxiliary Detectors) module provides a general-purpose interface to allow other detector systems that work in concert with the digital data acquisition (DAQ) sytems of Digital Gammasphere (DGS) and GRETINA to receive the timestamp and triggering information from those systems to synchronize the data acquisition system of an auxiliary detector used in concert with these large detector arrays. Additionally the MyRIAD may be used to transmit time-stamped trigger messages from the auxiliary detector to the main system so that the main system may filter its event readout based upon the presence or absence of a local trigger in the auxiliary detector. Finally, the MyRIAD provides signal interface capabilities designed to allow legacy CAMAC-based detector DAQ systems to be directly controlled and interfaced by the DAQ system of DGS or GRETINA.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Double Image Polarimeter—Ultra Fast: Simultaneous Three-color (BVR) Polarimeter with Electron-multiplying Charge-coupled Devices

We describe a new instrument capable of high-precision (10{sup −5}) polarimetric observations simultaneously in three passbands (BVR). The instrument utilizes electron-multiplying charge-coupled device (EM CCD) cameras for high efficiency and fast image readout. The key features of the Double Image Polarimeter—Ultra Fast (DIPol-UF) are: (i) the optical design with high throughput and inherent stability; (ii) great versatility, which makes the instrument optimally suitable for observations of bright and faint targets; and (iii) a control system, which allows the use of the polarimeter remotely. Examples are given of the first results obtained from high signal-to-noise observations of bright nearby stars and of fainter sources such as X-ray binaries in their quiescent states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory, Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (V ov ) of SiPMs using the LED as well as a cosmic muon telescope. The V ov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. Furthermore, this paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the V ov of the SiPMs and muon selection criteria for the veto detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical mass memory investigation

The MASTER 1 optical mass storage system advanced working model (AWM) was designed to demonstrate recording and playback of imagery data and to enable quantitative data to be derived as to the statistical distribution of raw errors experienced through the system. The AWM consists of two subsystems, the recorder and storage and retrieval. The recorder subsystem utilizes key technologies such as an acoustic travelling wave lens to achieve recording of digital data on fiche at a rate of 30 Mbits/sec, whereas the storage and retrieval reproducer subsystem utilizes a less complex optical system that employs an acousto-optical beam deflector to achieve data readout at a 5 Mbits/sec rate. The system has the built in capability for detecting and collecting error statistics. The recorder and storage and retrieval subsystems operate independent of one another and are each constructed in modular form with each module performing independent functions. The operation of each module and its interface to other modules is controlled by one controller for both subsystems.

Source record↗

A Telescope Using CMS PSI46 Pixels and the CAPTAN for Acquisition and Control over Gigabit Ethernet

The Electronic Systems Engineering department of the Computing Division at the Fermi National Accelerator Laboratory has assembled a pixel test beam telescope for high energy physics detector research and development. The telescope features CMS PSI46 readout chips and a data acquisition and control system known as the Compact And Programmable daTa Acquisition Node or CAPTAN. The CAPTAN is a flexible and powerful system that meets the readout and control demands of a variety of pixel and strip detectors for high energy physics applications. The CAPTAN functions in a gigabit Ethernet network, which facilitates the coordination of the multiple pixel planes of the telescope. Through the use of the CAPTAN hardware, a unified telescope system is attained encompassing both the CMS PSI46 pixel components and adevice under test. This paper discusses results from the telescope project including mechanical design, alignment procedure, and attainble precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A data acquisition system for marine and ecological research.

Description of a self-contained portable data acquisition system for use in marine and ecological research. The compact lightweight data acquisition system is capable of recording 14 variables in its present configuration and is suitable for use in either a boat, pickup truck, or light aircraft. This system will provide the acquisition of reliable data on the structure of the environment and the effect of man-made and natural activities on the observed phenomenon. Utilizing both self-contained analog recording and a telemetry transmitter for real-time digital readout and recording, the prototype system has undergone extensive testing. Currently undergoing component performance upgrading, the prototype system has been utilized in several environmental science investigations associated with air pollution investigations and weather modification and is currently being used for marine data acquisition.

Johnson, R. A.↗

A Data Acquisition System (DAS) for marine and ecological research from aerospace technology

The efforts of researchers at Mississippi State University to utilize space-age technology in the development of a self-contained, portable data acquisition system for use in marine and ecological research are presented. The compact, lightweight data acquisition system is capable of recording 14 variables in its present configuration and is suitable for use in either a boat, pickup truck, or light aircraft. This system will provide the acquisition of reliable data on the structure of the environment and the effect of man-made and natural activities on the observed phenomenon. Utilizing both self-contained analog recording and a telemetry transmitter for real-time digital readout and recording, the prototype system has undergone extensive testing.

Johnson, R. A.↗

The Design of a Distributed Key-Value Store for Petascale Hot Storage in Data Acquisition Systems

Data acquisition systems for high energy physics experiments readout terabytes of data per second from a large number of electronic components. They are thus inherently distributed systems and require fast online data selection, otherwise requirements for permanent storage would be enormous. Still, incoming data need to be buffered while waiting for this selection to happen. Each minute of an experiment can produce hundreds of terabytes that cannot be lost before a selection decision is made. In this context, we present the design of DAQDB (Data Acquisition Database) - a distributed key-value store for high-bandwidth, generic data storage in event-driven systems. DAQDB offers not only high-capacity and low-latency buffer for fast data selection, but also opens a new approach in high-bandwidth data acquisition by decoupling the lifetime of the data analysis processes from the changing event rate due to the duty cycle of the data source. This is achievable by the option to extend its capacity even up to hundreds of petabytes to store hours of an experiment’s data. Our initial performance evaluation shows that DAQDB is a promising alternative to generic database solutions for the high luminosity upgrades of the LHC at CERN.

97 MATHEMATICS AND COMPUTING↗

IMU/GPS System Provides Position and Attitude Data

A special navigation system is being developed to provide high-quality information on the position and attitude of a moving platform (an aircraft or spacecraft), for use in pointing and stabilization of a hyperspectral remote-sensing system carried aboard the platform. The system also serves to enable synchronization and interpretation of readouts of all onboard sensors. The heart of the system is a commercially available unit, small enough to be held in one hand, that contains an integral combination of an inertial measurement unit (IMU) of the microelectromechanical systems (MEMS) type, Global Positioning System (GPS) receivers, a differential GPS subsystem, and ancillary data-processing subsystems. The system utilizes GPS carrier-phase measurements to generate time data plus highly accurate and continuous data on the position, attitude, rotation, and acceleration of the platform. Relative to prior navigation systems based on IMU and GPS subsystems, this system is smaller, is less expensive, and performs better. Optionally, the system can easily be connected to a laptop computer for demonstration and evaluation. In addition to airborne and spaceborne remote-sensing applications, there are numerous potential terrestrial sensing, measurement, and navigation applications in diverse endeavors that include forestry, environmental monitoring, agriculture, mining, and robotics.

Lin, Ching Fang↗

DAQExpert the service to increase CMS data-taking efficiency

The Data Acquisition (DAQ) system of the Compact Muon Solenoid (CMS) experiment at the LHC is a complex system responsible for the data readout, event building and recording of accepted events. Its proper functioning plays a critical role in the data-taking efficiency of the CMS experiment. In order to ensure high availability and recover promptly in the event of hardware or software failure of the subsystems, an expert system, the DAQ Expert, has been developed. It aims at improving the data taking efficiency, reducing the human error in the operations and minimising the on-call expert demand. Introduced in the beginning of 2017, it assists the shift crew and the system experts in recovering from operational faults, streamlining the post mortem analysis and, at the end of Run 2, triggering fully automatic recovery without human intervention. DAQ Expert analyses the real-time monitoring data originating from the DAQ components and the high-level trigger updated every few seconds. It pinpoints data flow problems, and recovers them automatically or after given operator approval. We analyse the CMS downtime in the 2018 run focusing on what was improved with the introduction of automated recovery; present challenges and design of encoding the expert knowledge into automated recovery jobs. Furthermore, we demonstrate the web-based, ReactJS interfaces that ensure an effective cooperation between the human operators in the control room and the automated recovery system. We report on the operational experience with automated recovery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Assessment of Microwave Readout Multiplexing Factor

Ultra-high resolution microcalorimeter gamma spectroscopy is a new non-destructive assay technology for measurement of plutonium isotopic composition, with the potential to reduce total measurement uncertainty to a level competitive with destructive analysis methods [1-4]. Achieving this level of performance in practical applications requires not only the energy resolution now routinely achieved with transition-edge sensor microcalorimeter arrays (an order of magnitude better than for germanium detectors) but also high throughput. Microcalorimeter gamma spectrometers have not yet achieved detection efficiency and count rate capability that is comparable to germanium detectors, largely because of limits from existing readout technology. Microcalorimeter detectors must be operated at low temperature to achieve their exceptional energy resolution. Although the typical 100 mK operating temperatures can be achieved with reliable, cryogen-free systems, the cryogenic complexity and heat load from individual readout channels for large sensor arrays is prohibitive. Multiplexing is required for practical systems. The most mature multiplexing technology at present is time-division multiplexing (TDM) [3, 5-6]. In TDM, the sensor outputs are switched by applying bias current to one SQUID amplifier at a time. Transition-edge sensor (TES) microcalorimeter arrays as large as 256 pixels have been developed for X-ray and gamma-ray spectroscopy using TDM technology. Due to bandwidth limits and noise scaling, TDM is limited to a maximum multiplexing factor of approximately 32-40 sensors on one readout line [8]. Increasing the size of microcalorimeter arrays above the kilopixel scale, required to match the throughput of germanium detectors, requires the development of a new readout technology with a much higher multiplexing factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗