Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Design of Phosphor Thermometry System for Transient High Heat Flux Surface Thermometry

Abstract: A transformative calibration methodology is presented for predicting transient surface temperatures in a thermally conducting medium from in-depth, time-varying temperature measurements. The surface temperature is resolved using two experimental runs and a newly devised first-kind Volterra integral equation. The first experimental run involves calibration with known surface temperature while the second run involves resolving the surface temperature of interest through the ill-posed integral equation. This paper presents the concept genesis and numerically demonstrates the concept for feasibility, robustness, stability and accuracy. From this demonstration, we propose to implement surface placed thermographic phosphors in the calibration stage of the inverse method for estimating the required surface temperature. As a preliminary study, we consider transient, constant property, onedimensional heat conduction in a semi-infinite medium. It is mathematically demonstrated that a Volterra integral equation of the first kind is developed for estimating the surface temperature using a calibrated system (host material and sensor). Sensor characterization, explicit sensor positioning and thermophysical properties are implicitly contained in the new calibration integral equation. The calibration integral equation displays only four terms; namely, the measured front surface temperature and corresponding measured in-depth temperature response associated with the calibration run; and, the unknown surface temperature and its measured in-depth temperature response associated with the second run. Preliminary numerical results indicate the merit of the concept. This paper suggests using thermographic phosphors for estimating the surface temperature in the calibration portion of the process owing to their rapid thermal response, good surface thermal contact characteristics and lack of capacitance for assuring minimal delay. Though the present paper describes the theoretical basis for resolving such problems, it is intended for near-term application using the UTK s high-heat flux laser facility which is presently under development

Fluorescence thermometry↗

Reflected solar radiance seen by satellite

We derive the integral expression for the reflected solar flux F (W/m 2 ) seen by a sensor deployed on a satellite circling the earth at elevation h t . The sensor’s responsivity is that of a Si photodiode, (0.3, 1.1) µm. We first ignore atmospheric absorption, but account for light emanating from all angles, zenith up to parallel to earth surface. The expression, which holds for all “Solar–Earth–Sensor” (elevation) angles φ e , corrects a long-used equation in the USNDS program, that models “background irradiance,” Ramsey [3], Eq.(2.2). Flux striking the sensor is proportional to the sea-level solar radiance I 0 and the average earth albedo A. Results are displayed for h t = 2.02 · 10 4 km. The integral varies with angle φ e , i.e., F = F(φ e ). When sensor and sun are aligned with earth center, F = F(0) = 0.620 I 0 AR 2 , where R = r e /(r e + h t ) and r e is the average earth radius. For the specified h t , |φ e | < 180 - θ 0 deg, where θ 0 = 13.90. For larger angles, F = 0 since the sensor cannot see any part of earth illuminated by the sun. The flux F(φ e ) decays as ϵ 3.5 when φ e = 180-θ 0 - ϵ and ϵ→ 0, i.e., as the sensor enters darkness. Our ϵ 3.5 result differs from Ramsey’s [3], Eq.(2.2), which has ϵ 4.3 . We conclude Eq.(2.2) is incorrect for two reasons: the erroneous decay and, more importantly, that it vanishes only at φ e = 180. Our result, Eq.(14), presents a simple approximation to F(φ e ), accurate to better than 0.5%. The approximation blends Ramsey’s expression for small φ e with an ϵ 3.5 decay for large angles. Assuming a solar radiance I 0 = 1120, W/m 2 Wikipedia [7], and albedo A = 0.3, NASA, yields F(0) = 3.8 W/m 2 , which is 80% less than the leading term in Ramsey [3], Eq.(2.2). If atmospheric absorption is not ignored our integrand is modified by the factor exp(-τ N atm ), where τ is the atmosphere’s optical depth and N atm accounts for slant path absorption. The result is spectrally dependent. Absorption significantly decreases the flux as φ e → 180 - θ 0 .

79 ASTRONOMY AND ASTROPHYSICS↗

Application of 3D Printing for Smart Objects with Embedded Electronic Sensors and Systems

Applications of a 3D printing process are presented. This process integrates liquid-state printed components and interconnects with IC chips in all three dimensions, various orientations, and multiple printing layers to deliver personalized system-level functionalities. Here, as an example application, a form-fitting glove is demonstrated with embedded programmable heater, temperature sensor, and the associated control electronics for thermotherapeutic treatment.

36 MATERIALS SCIENCE↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterisation of irradiated thin silicon sensors for the CMS phase II pixel upgrade

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment’s silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equivalent fluence of up to $\Phi _{eq} = 2 \times 10^{16}$ cm$^{-2}$ , and an ionising dose of ${\approx } 5$ MGy after an integrated luminosity of 3000 fb$^{-1}$ . Thin, planar silicon sensors are good candidates for this application, since the degradation of the signal produced by traversing particles is less severe than for thicker devices. In this paper, the results obtained from the characterisation of 100 and 200 $\upmu $ m thick p-bulk pad diodes and strip sensors irradiated up to fluences of $\Phi _{eq} = 1.3 \times 10^{16}$ cm$^{-2}$ are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control Center Viewing of UAS-Based Real-Time Sensor and Video Measurements at an Electric Utility Facility

Drones equipped with video cameras, LIDAR and thermal imagers have been demonstrated in industrial and utility settings. In such instances, the images are typically locally stored onboard the drone then retrieved from the image storage media and analyzed. We report on a project involving the transport and display of measurements and thermal and visual video streams into a utility control center. Relying on an integrated multimedia communications network, realtime control center viewing of sensor readings and image streams is achieved. Details of this activity are reported.

42 ENGINEERING↗

Measured Indoor Nitrogen Oxides in Homes with a Child with Asthma and Gas or Induction Electric Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study is a randomized control trial investigating the effects of replacing gas with induction electric ranges in the homes of children with asthma in California's San Joaquin Valley. Indoor air quality parameters and respiratory health indicators were measured over 2-week intensive at Baseline and after consecutive 3-month study phases, with half getting electric cooking at the start of Phase 1 and others in Phase 2. Indoor air measurements included time-integrated NO 2 and NO X by passive sampler and time-resolved NO 2 by electrochemical sensors. In the first 40 homes, data were collected during 61 intensives for gas cooking and 55 for induction. Cooking was identified using temperature sensors above the cooktop. Pollutant events were identified from sharp rises in concentrations Time integrated NOX species were lower with electric cooking, with mean differences of 14.2 ppb for NO 2 (95% CI: 9.6, 18.7; p < 0.001), 55.6 ppb for NO X (95% CI: 30.4, 80.9; p < 0.001), and 41.5 ppb for derived NO (95% CI: 19.7, 63.2; p < 0.001). A paired, within home analysis showed larger reductions in Group 2 (gas to induction) than Group 1 that remained electric across Phase 1 and Phase 2 for NO 2 (mean difference in As of 10.5 ppb; 95% CI: 5.6, 15.4; p < 0.001), NO X (32.3 ppb; 95% CI: 10.0, 54.5; p=0.007), and derived NO (21.8 ppb; 95% CI: 3.6, 40.0; p=0.022). Compared to electric cooking, gas had much higher rates of associated NO 2 events, and larger above-baseline NO 2 peaks. These preliminary results are consistent with prior findings that shifting to induction cooking can substantially lower indoor NO 2 compared with gas cooking.

Fang, Yi↗

Enhancing Camera Calibration for Traffic Surveillance with an Integrated Approach of Genetic Algorithm and Particle Swarm Optimization

Recent advancements in sensor technologies, coupled with signal processing and machine learning, have enabled real-time traffic control systems to effectively adapt to changing traffic conditions. Cameras, as sensors, offer a cost-effective means to determine the number, location, type, and speed of vehicles, aiding decision-making at traffic intersections. However, the effective use of cameras for traffic surveillance requires proper calibration. This paper proposes a new optimization-based method for camera calibration. In this approach, initial calibration parameters are established using the Direct Linear Transformation (DLT) method. Then, optimization algorithms are applied to further refine the calibration parameters for the correction of nonlinear lens distortions. A significant enhancement in the optimization process is achieved through the integration of the Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) into a combined Integrated GA and PSO (IGAPSO) technique. The effectiveness of this method is demonstrated through the calibration of eleven roadside cameras at three different intersections. The experimental results show that when compared to the baseline DLT method, the vehicle localization error is reduced by 22.30% with GA, 22.31% with PSO, and 25.51% with IGAPSO.

47 OTHER INSTRUMENTATION↗

The Concept of a Quantum Edge Simulator: Edge Computing and Sensing in the Quantum Era

Sensors, enabling observations across vast spatial, spectral, and temporal scales, are major data generators for information technology (IT). Processing, storing, and communicating this ever-growing amount of data pose challenges for the current IT infrastructure. Edge computing—an emerging paradigm to overcome the shortcomings of cloud-based computing—could address these challenges. Furthermore, emerging technologies such as quantum computing, quantum sensing, and quantum communications have the potential to fill the performance gaps left by their classical counterparts. Here, we present the concept of an edge quantum computing (EQC) simulator—a platform for designing the next generation of edge computing applications. An EQC simulator is envisioned to integrate elements from both quantum technologies and edge computing to allow studies of quantum edge applications. The presented concept is motivated by the increasing demand for more sensitive and precise sensors that can operate faster at lower power consumption, generating both larger and denser datasets. These demands may be fulfilled with edge quantum sensor networks. Envisioning the EQC era, we present our view on how such a scenario may be amenable to quantification and design. Given the cost and complexity of quantum systems, constructing physical prototypes to explore design and optimization spaces is not sustainable, necessitating EQC infrastructure and component simulators to aid in co-design. We discuss what such a simulator may entail and possible use cases that invoke quantum computing at the edge integrated with new sensor infrastructures.

47 OTHER INSTRUMENTATION↗

Provenance In Sensor Data Management: A Cohesive, Independent Solution

In today's information-driven workplaces, data is constantly undergoing transformations and being moved around. The typical business-as-usual approach is to use email attachments, shared network locations, databases, and now, the cloud. More often than not, there are multiple versions of the data sitting in different locations and users of this data are confounded by the lack of metadata describing its provenance, or in other words, its lineage. Our project is aimed to solve this issue in the context of sensor data. The Oak Ridge National Laboratory's Building Technologies Research and Integration Center has reconfigurable commercial buildings deployed on the Flexible Research Platforms (FRPs). These FRPs are instrumented with a large number of sensors which measure a number of variables such as HVAC efficiency, relative humidity, and temperature gradients across doors, windows, and walls. Sub-minute resolution data from hundreds of channels is acquired. This sensor data, traditionally, was saved to a shared network location which was accessible to a number of scientists for performing complicated simulation and analysis tasks. The sensor data also participates in elaborate quality assurance exercises as a result of inherent faults. Sometimes, faults are induced to observe building behavior. It became apparent that proper scientific controls required not just managing the data acquisition and delivery, but to also manage the metadata associated with temporal subsets of the sensor data. We built a system named ProvDMS, or Provenance Data Management System for the FRPs, which would both allow researchers to retrieve data of interest as well as trace data lineage. This provides researchers a one-stop shop for comprehensive views of various data transformation allowing researchers to effectively trace their data to its source so that experiments, and derivations of experiments, may be reused and reproduced without much overhead of the repeatability of experiments that use it. Using these traces, researchers can determine exactly what happens to data as it moves through its life cycle.

Hensley, Zachary P↗

NuScale Power Module Instrumentation

The safe and efficient operation of any nuclear power plant (NPP) depends on accurate and timely measurement of the primary system temperature, pressure, level, flow, and neutron flux. Integral pressurized water reactor (iPWR) or small modular reactors (SMRs) present unique challenges to instrumentation and control (I&C) sensors and their maintenance strategies. More specifically, the calibration and response time of these sensors may have to be verified periodically to ensure that they maintain their required degree of accuracy and speed of response. A review of technical reports and safety analysis documentation of the NuScale Power Module (NPM) by Analysis and Measurement Services Corporation (AMS), together with NuScale engineers, confirms that the I&C sensors within the NPM will need to be testable as installed to verify their static and dynamic performance at plant operating conditions. Sensor placement and installation as well as the process conditions expected in natural circulation integral SMRs like the NPM are very different from those in large scale NPPs with conventional primary system loop piping. In particular, reactor coolant system (RCS) flows are more complex and flow rates much lower, the average containment temperature is higher, nuclear radiation levels in some areas are greater, and the accessibility of sensors for hands-on maintenance is very limited. These challenges among others related to I&C sensors can be overcome by adapting existing I&C sensor test methods, developing new techniques for non-conventional I&C sensors, and incorporating online monitoring (OLM) technologies into the I&C architecture of the plant to verify the calibration and response time of sensors within the NPM prior to startup, during operation, and during subsequent refueling outages. These methods and technologies will be demonstrated and validated through a research and development (R&D) grant recently awarded to AMS by the U.S. Department of Energy (DOE) to facilitate timely deployment of the first NuScale SMR in the United States and to enable efficient I&C maintenance strategies during the life of the plant. Lastly, this paper presents the R&D plan for the DOE project with a focus on temperature measurement needs of NuScale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NXIS - Well integrity inspection in unconventional gas wells

The objective of this project is to advance the state-of-the-art and to develop an integrity inspection system capable of detecting physical flaws in the wellbore structure of conventional and unconventional hydrocarbon producing wells. Measuring the integrity of multiple wellbore casings and cement annuli for onshore and offshore wells remains a challenging task. We propose a multi-modality inspection system composed of neutron and X(gamma)-ray imaging modalities (nXis) to address the above challenge. The functional principle of this wellbore integrity inspection system is the combination of high-energy modalities, such as X(gamma)-ray and neutron backscatter imaging, with conventional low-energy modalities, such as electromagnetic or ultrasound imaging techniques. By combining multiple sensing modalities into one sensing system and by fusing data between modalities, one can gather more information about the integrity of the wellbore structure compared to simply using multiple sensors individually. Imaging prototypes for gamma, neutron, and electromagnetics were designed, manufactured, and tested at GE Global Research and Starfire Industries. Wellbore phantoms with engineered defects were manufactured and the performance of the developed wellbore integrity inspection tool prototypes was evaluated in a test pit test at an industrial GE Oil & Gas facility. Data analysis and fusion between various inspection techniques show enhanced defect detectability. These exciting results were presented at various technical conferences and discussed with operators in the oil & gas industry. Great interest from oil operators lead to discussions about joint industrial partnerships to move the developed technology from the prototype phase to the product phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Air Conditioning Systems Fault Detection and Diagnosis-Based Sensing and Data-Driven Approaches

The air conditioning (AC) system is the primary building end-use contributor to the peak demand for energy. The energy consumed by this system has grown as fast as it has in the last few decades, not only in the residential section but also in the industry and transport sectors. Therefore, to combat energy crises, urgent actions on energy efficiency should be taken to support energy security. Consequently, the faults in AC system components increase energy consumption due to the degradation of the system’s performance and the losses in the energy conversion procedure. In this work, AC system fault detection and diagnosis (FDD) methods are investigated to propose analytic tools to identify faults and provide solutions to those problems. The analysis of existing work shows that data-driven approaches are more accurate for both soft and hard fault detection and diagnosis in AC systems. Therefore, the proposed methods are not accurate for simultaneous fault detection, while in some works, authors tested the method with several faults separately without investigating scenarios that combine more than one fault. Moreover, this study shows that integrating data-driven approaches requires deploying an optimal sensing and measurement architecture that can detect a maximum number of faults with minimally deployed sensors. The new sensing, information, and communication technologies are discussed for their integration in AC system monitoring in order to optimize system operation and detect faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Target diagnostic control system implementation for the National Ignition Facility (invited)

The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flexible organic integrated electronics for self-powered multiplexed ocular monitoring

Smart contact lens has drawn extensive research interests due to the noninvasive real-time detection of the human body to provide biomedical information for health management. However, it has been difficult to accurately measure the physiological signals in tears, and the use of external power source has also hindered the future applications. Here, we demonstrated an organic electrochemical transistor based multiplexed sensors self-powered by the organic solar cells (OSCs). The integrated device was fabricated via simple process including solution blade-coating and thermal evaporation. OSCs were optimized to provide optimal operation voltage for the sensors that exhibit semilog-linear response to the glucose and calcium ions in tear fluids without any peripheral circuits. The sensing signals can be transmitted to the laptop wirelessly through a near filed communication unit. This integrated self-powered multiplexed sensing device will provide real-time monitoring of the biomarkers in tears, prospected to be installed on the smart contact lens for the early detection and diagnosis of diabetes.

36 MATERIALS SCIENCE↗

A theoretical study of a nano-opto-mechanical sensor using a photonic crystal-cantilever cavity

In this simulation study, integration of a nanocantilever inside a two-dimensional (2D) photonic crystal (PC) cavity resulted in a unique photonic crystal-cantilever cavity (PC 3 ), where the cantilever served as a tunable mechanical defect of the PC slab. Strong nano-opto-mechanical interactions between the cantilever and the defect-mode field inside the PC 3 gave rise to a high sensitivity of the resonance wavelength to surface stress-induced cantilever deflection. Mechanical and optical responses of the PC 3 to surface stress changes on the cantilever surface were studied by using a finite-element method (FEM) and a finite-difference time-domain (FDTD) method, respectively. Theoretical analysis revealed that the devised PC 3 sensor could resolve a conservative minimum surface stress at the level of ~0.8 mN m -1 , representing state-of-the-art cantilever sensor performance. Also, the PC 3 sensor design used an ultracompact structure with an on-chip optical length of only several microns, while a conventional reflected laser beam detection scheme requires a ~1 m long free-space optical path.

36 MATERIALS SCIENCE↗

Pyroprocessing Monitoring Technology Development at Idaho National Laboratory

The Idaho National Laboratory (INL), with support from the U.S. Department of Energy, Office of Nuclear Energy, Nuclear Technology Research and Development program, has been developing advanced instrumentation and approaches for enhancing the effectiveness of nuclear material control and accounting for future reprocessing facilities with particular emphasis on pyroprocessing. Advanced modeling capabilities augment new instrumentation development, predict material flows, integrate process monitoring data, and assess overall system effectiveness of the safeguards and security system. In this paper we provide a brief overview of the Safeguards and Security by Design approach being pursued under the program and details of advanced process monitoring instrumentation under development at the INL, which includes a triple bubbler system for on-line monitoring of level and density of molten salt, sensors for monitoring actinide concentrations in molten salt, and thermal-couple instrumentation for near real time determination of Pu content in U/TRU ingots. Laboratory and field testing data will be presented, as well as integration of these sensors into a concept for utilization of process monitoring information in concert with traditional nuclear material accountancy data.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Halo current diagnostic system of experimental advanced superconducting tokamak

The design, calibration, and installation of disruption halo current sensors for the Experimental Advanced Superconducting Tokamak are described in this article. All the sensors are Rogowski coils that surround conducting structures, and all the signals are analog integrated. Coils with two different cross-section sizes have been fabricated, and their mutual inductances are calibrated. Sensors have been installed to measure halo currents in several different parts of both the upper divertor (tungsten) and lower divertor (graphite) at several toroidal locations. Initial measurements from disruptions show that the halo current diagnostics are working well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗