Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Spectroscopy of atoms in an optical dipole trap using spectrally selective heating by a probe laser field

Spectral properties of atoms localised in an optical dipole trap are studied using the method of spectrally selective heating by a probe field. The method is based on measuring the number of atoms in a trap after they interact with a probe field. The dependence of the number of atoms on the frequency of the probe field fully characterises the shift and width of the spectral absorption line of trapped atoms. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the Spectral Stability of the Generalized Runge–Kutta Methods Applied to Initial-Boundary-Value Problems for Equations of the Parabolic Type. I. Explicit Methods

We develop a general algorithm for the analysis the spectral stability of generalized multistage Runge–Kutta methods of various orders of accuracy as applied to the numerical integration with respect to time of an initial-boundary-value problem for the second-order parabolic equation. The expression for the function of spectral stability is obtained in two alternative forms: on the basis of matrix relations and in the determinant form. We study specific realizations of various generalized explicit Runge–Kutta methods and their spectral stability. It is shown that all explicit generalized Runge–Kutta methods possess the property of conditional spectral stability and the property of conditional monotonicity of the numerical solution in time whose violation leads to the appearance of false oscillations of the approximate solution. The stability function for these methods is polynomial. It is shown that the application of two-stage generalized explicit Runge–Kutta methods leads to the appearance of predictor-corrector-type schemes. In the case of nonstationary one-dimensional heat-conduction problem, on the basis of a one-stage generalized Runge–Kutta method, we obtain the classical two-layer conditionally stable explicit finite-difference scheme on a four-point template. It is demonstrated that the five-stage generalized Runge–Kutta–Merson method is characterized by the weakest condition of spectral stability as compared with all investigated explicit generalized Runge–Kutta methods.

42 ENGINEERING↗

Spectral measurements by the filter method on Lewis' carbon arc solar simulators

There exists a problem in the measuring of the spectral irradiance of solar simulators. This difficulty has manifested intself in both monochromator and filter measurements. This report is the discussion of the measurements by Eppley Laboratory on the Lewis carbon arc solar Simulators, the further analysis of the method of filter radiometry made by Lewis personnel, and the comparison with the monochromator measurements. Previously when the filter technique was used it was assumed that the a priori knowledge of the source's spectral characteristics must be known. In this report it will be shown that for a carb0n arc source a knowledge of the source is not required after the filters have been properly chosen.

RADIOMETRY↗

An approach based on dwindling filter method for positive definite generalized eigenvalue problem

In this paper, we present a new spectral residual method for solving large-scale positive definite generalized eigenvalue problems. The proposed algorithm is equipped with a dwindling multidimensional nonmonotone filter, in which the envelope dwindles as the step length decreases. We have also employed a relaxed nonmonotone line search technique in the structure of the algorithm which allows it to enjoy the nonmonotonicity from scratch. Under some mild and standard assumptions, the global convergence property of the proposed algorithm is established. An implementation of the new algorithm on some test problems shows the efficiency and effectiveness of the proposed algorithm in practice.

97 MATHEMATICS AND COMPUTING↗

Cross-calibration of Imaging Sensors using Model-based, SI-traceable Predictions of At-sensor Radiance

Many inter-consistency efforts force empirical agreement between sensors viewing a source nearly coincident in time and geometry that ensures consistency between sensors rather than obtain an SI-traceable calibration with documented error budgets. The method described here provides interconsistency via absolute radiometric calibration with defensible error budget avoiding systematic errors through prediction of at-sensor radiance for a site viewed by multiple sensors but not necessarily viewed at coincident times. The method predicts spectral radiance over a given surface site for arbitrary view and illumination angles and for any date dominated by clear-sky conditions. The foundation is a model-based, SI-traceable prediction of at-sensor radiance over selected sites based on physical understanding of the surface and atmosphere. The calibration of the ground site will include spatial, spectral, and sunview geometric effects based on satellite and ground-based data. The result is an interconsistency of hyperspectral and multispectral sensors spanning spatial resolutions from meters to kilometers all relative to the surface site rather than a single sensor. The source-centric philosophy of calibrating the site inherently accounts for footprint size mismatch, spectral band mismatch, and temporal and spatial sampling effects. The method for characterizing the test site allows its use for SI-traceable calibration of any sensor that can view the calibrated test site. Interconsistency is obtained through the traceability and error budget rather than coincident views. Such an approach to inter-consistency provides better understanding of biases between sensors as well producing more accurate results with documented SI-traceability that reduces the need for overlapping data sets.

Thome, Kurtis↗

Aircraft Engine Noise Scattering by Fuselage and Wings: A Computational Approach

The paper presents a time-domain method for computation of sound radiation from aircraft engine sources to the far-field. The effects of nonuniform flow around the aircraft and scattering of sound by fuselage and wings are accounted for in the formulation. The approach is based on the discretization of the inviscid flow equations through a collocation form of the Discontinuous Galerkin spectral element method. An isoparametric representation of the underlying geometry is used in order to take full advantage of the spectral accuracy of the method. Large-scale computations are made possible by a parallel implementation based on message passing. Results obtained for radiation from an axisymmetric nacelle alone are compared with those obtained when the same nacelle is installed in a generic configuration, with and without a wing.

Stanescu, D.↗

Aircraft Engine Noise Scattering by Fuselage and Wings: A Computational Approach

The paper presents a time-domain method for computation of sound radiation from aircraft engine sources to the far field. The effects of non-uniform flow around the aircraft and scattering of sound by fuselage and wings are accounted for in the formulation. The approach is based on the discretization of the inviscid flow equations through a collocation form of the discontinuous Galerkin spectral element method. An isoparametric representation of the underlying geometry is used in order to take full advantage of the spectral accuracy of the method. Large-scale computations are made possible by a parallel implementation based on message passing. Results obtained for radiation from an axisymmetric nacelle alone are compared with those obtained when the same nacelle is installed in a generic configuration, with and without a wing. 0 2002 Elsevier Science Ltd. All rights reserved.

Farassat, F.↗

Linear and circular digital spectral analysis of serial data

Two methods of digital spectral analysis of unevenly sampled data are developed and illustrated here. One method uses a linear function of time (or space), the other uses circular functions. The circular method turns out to be essentially equivalent to a least-squares sine-wave analysis. The linear, anharmonic method uses only the field of real numbers and elementary algebraic operations, and hence it can be made computationally very fast and accurate. Both methods are very general, properly handling all kinds of time series ranging from simple series consisting only of the times of events to complicated series consisting of pulses with long duty cycles. The two methods are here applied to the analysis of annual mean relative sunspot numbers.

Stothers, Richard B.↗

Islet: interpolation semi-Lagrangian element-based transport

Abstract. Advection of trace species, or tracers, also called tracer transport, in models of the atmosphere and other physical domains is an important and potentially computationally expensive part of a model's dynamical core. Semi-Lagrangian (SL) advection methods are efficient because they permit a time step much larger than the advective stability limit for explicit Eulerian methods without requiring the solution of a globally coupled system of equations as implicit Eulerian methods do. Thus, to reduce the computational expense of tracer transport, dynamical cores often use SL methods to advect tracers. The class of interpolation semi-Lagrangian (ISL) methods contains potentially extremely efficient SL methods. We describe a finite-element ISL transport method that we call the interpolation semi-Lagrangian element-based transport (Islet) method, such as for use with atmosphere models discretized using the spectral element method. The Islet method uses three grids that share an element grid: a dynamics grid supporting, for example, the Gauss–Legendre–Lobatto basis of degree three; a physics parameterizations grid with a configurable number of finite-volume subcells per element; and a tracer grid supporting use of Islet bases with particular basis again configurable. This method provides extremely accurate tracer transport and excellent diagnostic values in a number of verification problems.

58 GEOSCIENCES↗

Remote Sensing of Atmospheric Temperature, Water Vapor, Trace Gases, Cloud, and Surface Properties on Daily and Decadal Time Scales

Hyperspectral IR sounders such as AIRS on Aqua, CrIS on S-NPP, NOAA20 and JPSS-2, IASI on Metop A, B, and C provide high-quality atmospheric temperature, water, vapor, and greenhouse gas vertical profiles. Additionally, they provide atmospheric cloud properties, surface emissivity, and surface skin temperatures. We have developed two algorithms which can consistently derive these products from multiple IR sounders. The first one is a Single Field-of-view Sounder Atmospheric Product (SIFSAP) algorithm and the second one is a Climate Fingerprinting Sounder Product (ClimFiSP) algorithm. The SiFSAP algorithm performs one retrieval for each FOV using an all-sky optimal estimation approach. The core of the SiFSAP algorithm is an accurate and fast Principal Component-based Radiative Transfer Model (PCRTM), which can calculate hyperspectral radiance spectra under both clear and cloudy conditions. The PCRTM was developed in the past decade using consistent reference line-by-line radiative transfer model and spectroscopy for hyperspectral sounders such as AIRS, CrIS, IASI, NAST-I, and S-HIS. The ClimFiSP algorithm, which performs retrievals from spatiotemporally averaged L1 hyperspectral radiances directly, will be orders of magnitude faster than traditional method. he ClimFiSP algorithm uses consistent radiative kernels and a robust spectral fingerprinting method. It provides accurate data climate data fusion products from multiple satellite sensors. Both SiFSAP and ClimFiSP will be available at NASA GES DISC data center for public access.

Xu Liu↗

Development of Radiative Transfer Models and Retrieval Algorithms for Satellite Remote Sensors

Hyperspectral IR sounders such as AIRS on Aqua, CrIS on S-NPP, NOAA20 and JPSS-2, IASI on Metop A, B, and C provide high-quality atmospheric temperature, water, vapor, and greenhouse gas vertical profiles. Additionally, they provide atmospheric cloud properties, surface emissivity, and surface skin temperatures. We have developed two algorithms which can consistently derive these products from multiple IR sounders. The first one is a Single Field-of-view Sounder Atmospheric Product (SIFSAP) algorithm and the second one is a Climate Fingerprinting Sounder Product (ClimFiSP) algorithm. The SiFSAP algorithm performs one retrieval for each FOV using an all-sky optimal estimation approach. The core of the SiFSAP algorithm is an accurate and fast Principal Component-based Radiative Transfer Model (PCRTM), which can calculate hyperspectral radiance spectra under both clear and cloudy conditions. The PCRTM was developed in the past decade using consistent reference line-by-line radiative transfer model and spectroscopy for hyperspectral sounders such as AIRS, CrIS, IASI, NAST-I, and S-HIS. The ClimFiSP algorithm, which performs retrievals from spatiotemporally averaged L1 hyperspectral radiances directly, will be orders of magnitude faster than traditional method. he ClimFiSP algorithm uses consistent radiative kernels and a robust spectral fingerprinting method. It provides accurate data climate data fusion products from multiple satellite sensors. Both SiFSAP and ClimFiSP will be available at NASA GES DISC data center for public access.

Xu Liu↗

A decision tree algorithm for investigation of model biases related to dynamical cores and physical parameterizations: CESM/CAM EVALUATION BY DECISION TREES

An object-based evaluation method using a pattern recognition algorithm (i.e., classification trees) is applied to the simulated orographic precipitation for idealized experimental setups using the National Center of Atmospheric Research (NCAR) Community Atmosphere Model (CAM) with the finite volume (FV) and the Eulerian spectral transform dynamical cores with varying resolutions. Daily simulations were analyzed and three different types of precipitation features were identified by the classification tree algorithm. The statistical characteristics of these features (i.e., maximum value, mean value, and variance) were calculated to quantify the difference between the dynamical cores and changing resolutions. Even with the simple and smooth topography in the idealized setups, complexity in the precipitation fields simulated by the models develops quickly. The classification tree algorithm using objective thresholding successfully detected different types of precipitation features even as the complexity of the precipitation field increased. The results show that the complexity and the bias introduced in small-scale phenomena due to the spectral transform method of CAM Eulerian spectral dynamical core is prominent, and is an important reason for its dissimilarity from the FV dynamical core. The resolvable scales, both in horizontal and vertical dimensions, have significant effect on the simulation of precipitation. The results of this study also suggest that an efficient and informative study about the biases produced by GCMs should involve daily (or even hourly) output (rather than monthly mean) analysis over local scales.

54 ENVIRONMENTAL SCIENCES↗

SU-C-207-06: In Vivo Quantification of Gold Nanoparticles Using K-Edge Imaging Via Spectrum Shaping by Gold Filter

Purpose: Gold nanoparticles (AuNP) are multifunctional platforms ideal for drug delivery, targeted imaging and radiosensitization. We have investigated quantitative imaging of AuNPs using on board imager (OBI) cone beam computed tomography (CBCT). To this end, we also present, for the first time, a novel method for k-edge imaging of AuNP by filter-based spectral shaping. Methods: We used a digital 25 cm diameter water phantom, embedded with 3 cm spheres filled with AuNPs of different concentrations (0 mg/ml – 16 mg/ml). A poly-energetic X-ray spectrum of 140 kVp from a conventional X-ray tube is shaped by balanced K-edge filters to create an excess of photons right above the K-edge of gold at 80.7 keV. The filters consist of gold, tin, copper and aluminum foils. The phantom with appropriately assigned attenuation coefficients is forward projected onto a detector for each energy bin and then integrated. FKD reconstruction is performed on the integrated projections. Scatter, detector efficiency and noise are included. Results: We found that subtracting the results of two filter sets (Filter A:127 µm gold foil with 254 µm tin, 330 µm copper and 1 mm aluminum, and Filter B: 635 µm tin with 264 µm copper and 1 mm aluminum), provides substantial image contrast. The resulting filtered spectra match well below 80.7 keV, while maintaining sufficient X-ray quanta just above that. Voxel intensities of AuNP containing spheres increase linearly with AuNP concentration. K-edge imaging provides 18% more sensitivity than the tin filter alone, and 38% more sensitivity than the gold filter alone. Conclusion: We have shown that it is feasible to quantitatively detect AuNP distributions in a patient-sized phantom using clinical CBCT and K-edge spectral shaping.

60 APPLIED LIFE SCIENCES↗

A Verification Suite of Test Cases for the Barotropic Solver of Ocean Models

Abstract The development of any atmosphere or ocean model warrants a suite of test cases (TCs) to verify its spatial and temporal discretizations, order of accuracy, stability, reproducibility, portability, scalability, etc. In this paper, we present a suite of shallow water TCs designed to verify the barotropic solver of atmosphere and ocean models. These include the non‐dispersive coastal Kelvin wave; the dispersive inertia‐gravity wave; the dispersive planetary and topographic Rossby waves; the barotropic tide; and a non‐linear manufactured solution. These TCs check the implementation of the linear pressure gradient term; the linear constant or variable‐coefficient Coriolis and bathymetry terms; and the non‐linear advection terms. Simulation results are presented for a variety of time‐stepping methods as well as two spatial discretizations: a mimetic finite volume method based on the TRiSK scheme, and a high‐order discontinuous Galerkin spectral element method. The experimental procedure for conducting these numerical experiments is detailed. It underscores several key considerations that vary depending on the chosen spatial discretization method. Finally, convergence studies of every TC are conducted with refinement in both space and time, only in space, and only in time. The convergence slopes match the expected theoretical predictions.

54 ENVIRONMENTAL SCIENCES↗

A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels

A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial Results in Using a Self-Coherence Method for Detecting Sustained Oscillations

This paper develops a self-coherence method for detecting sustained oscillations using phasor measurement unit (PMU) data. Sustained oscillations decrease system performance and introduce potential reliability issues. Timely detection of the oscillations at an early stage provides the opportunity for taking remedial reaction. Using high-speed time-synchronized PMU data, this paper details a self-coherence method for detecting sustained oscillation, even when the oscillation amplitude is lower than ambient noise. Simulation and field measurement data are used to evaluate the proposed method’s performance. It is shown that the proposed method can detect sustained oscillations and estimate oscillation frequencies with a low signal-to-noise ratio. Comparison with a power spectral density method also shows that the proposed self-coherence method performs better. Index Terms—coherence, power spectral density, phasor measurement unit (PMU), oscillations, power system dynamics

Zhou, Ning↗

Proof-of-Concept Study for Uncertainty Quantification and Sensitivity Analysis using the BRL Shaped-Charge Example

These are the slides for a graduate presentation at Mississippi State University. It covers the following: the BRL Shaped-Charge Geometry in PAGOSA, mesh refinement study, surrogate modeling using a radial basis function network (RBFN), ruling out parameters using sensitivity analysis (equation of state study), uncertainty quantification (UQ) methodology, and sensitivity analysis (SA) methodology. In summary, a mesh convergence study was used to ensure that solutions were numerically stable by comparing PDV data between simulations. A Design of Experiments (DOE) method was used to reduce the simulation space to study the effects of the Jones-Wilkins-Lee (JWL) Parameters for the Composition B main charge. Uncertainty was quantified by computing the 95% data range about the median of simulation output using a brute force Monte Carlo (MC) random sampling method. Parameter sensitivities were quantified using the Fourier Amplitude Sensitivity Test (FAST) spectral analysis method where it was determined that detonation velocity, initial density, C1, and B1 controlled jet tip velocity.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗