Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

High-resolution hypernuclear decay pion spectroscopy at MAMI and future

Hypernuclear decay pion spectroscopy was established in 2012 at MAMI as a mass spectroscopy method for light hypernuclei. A monochromatic pion peak from $^4_Λ$H was successfully observed, and the Λ binding energy was determined to be B Λ = 2.157±0.005(stat.)±0.077(syst.) MeV in the 2014 run. In 2022, an upgrade experiment for $^3_Λ$H spectroscopy was conducted using a newly developed Li target. The absolute electron beam energy will be measured by the synchrotron radiation interferometry, which will be applied with the spectrometer calibration to improve the systematic error. The decay pion spectroscopy is planned to be performed at JLab Hall-C, which would significantly increase the statistics thanks to the higher energy beam, the better K + identification, and the faster data acquisition system. This experiment has been submitted as a Letter of Intent in JLab PAC51. The upgraded decay pion spectroscopy method is expected to provide new, accurate hypernuclear data, which will contribute to the advancement of our understanding of hypernuclear physics

47 OTHER INSTRUMENTATION↗

Time-domain terahertz emission spectroscopy on van der Waals materials

Time-domain terahertz (THz) emission spectroscopy provides a direct method to probe transient photo-currents by recording the emitted terahertz electric field. Although the basic principles of THz surface emission have been understood for more than 30 years, the constant progress in ultrafast laser science to ever shorter pulses, the development of new materials and enhanced sensitivity promote THz emission spectroscopy as a reliable method to gain insights into charge carrier dynamics with unprecedented precision. It provides a versatile tool to study ultrafast processes, such as plasmon-driven hot carriers, dynamics of Dirac fermions, interfacial charge transfer, coherent phonon emission and quantum beating, to name only a few. However, despite the rapidly growing body of research on van der Waals materials, especially in their low-dimensional limit, THz emission spectroscopy has only been applied to a limited extent in these material systems. In this prospective, we review time-domain THz emission spectroscopy as a complementary approach to probe ultrafast charge carrier dynamics and the material’s nonlinear response. After a description of the experimental method, we report on THz emission spectroscopy of bulk and 2D van der Waals materials with special focus on graphene and transition metal dichalcogenide layers.

2D materials↗

Electronic Structure, Spectroscopy and Correlation Effects in Novel Materials

This project was targeted on electronic structure, spectroscopic studies, and correlation effects in a variety of novel materials of great current interest. Spectroscopies resolved highly in momentum, energy or spatial dimensions are playing a key role in unraveling the nature of the ground state and excitation properties in wide classes of novel materials. The seminal insights thus obtained are of critical importance not only for answering some of the fundamental questions facing condensed matter physics and materials science today, but also for understanding and thus helping to design and develop new materials with desirable properties, which will continue to be the key to the survival of mankind and its energy needs as a technological society long into the future. However, spectroscopies do not provide a direct map of electronic states, but act as a very complex ‘filter’ or ‘mapping’ of the underlying spectrum. This connection between the electronic states and measured spectra—called the ‘matrix element effect’—is in general an extremely complex function of the phase space of the experiment (e.g. energy/polarization of photons in photoemission), presenting both a challenge and an opportunity. So motivated, this project pursued techniques for realistic treatment of electronic spectra of a wide variety of materials, which served as a prelude to formulating and implementing methodologies for making direct connection with various spectroscopies such as ARPES, STS/STM, and inelastic light scattering. Specific systems are topological materials, including 2D ultrathin films beyond graphene, novel superconductors, and nanocrystals, among others. Our goal was to exploit the strengths of various spectroscopies to piece together the most complete picture of electronic states in systems of current interest, enabling direct and sharpened confrontations with theoretical models, and also to help advance the reach of various spectroscopies.

36 MATERIALS SCIENCE↗

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis Tools for Next-Generation Hadron Spectroscopy Experiments

The series of workshops on New Partial-Wave Analysis Tools for Next-Generation Hadron Spectroscopy Experiments was initiated with the ATHOS 2012 meeting, which took place in Camogli, Italy, June 20-22, 2012. It was followed by ATHOS 2013 in Kloster Seeon near Munich, Germany, May 21-24, 2013. The third, ATHOS3, meeting is planned for April 13-17, 2015 at The George Washington University Virginia Science and Technology Campus, USA. The workshops focus on the development of amplitude analysis tools for meson and baryon spectroscopy, and complement other programs in hadron spectroscopy organized in the recent past including the INT-JLab Workshop on Hadron Spectroscopy in Seattle in 2009, the International Workshop on Amplitude Analysis in Hadron Spectroscopy at the ECT*-Trento in 2011, the School on Amplitude Analysis in Modern Physics in Bad Honnef in 2011, the Jefferson Lab Advanced Study Institute Summer School in 2012, and the School on Concepts of Modern Amplitude Analysis Techniques in Flecken-Zechlin near Berlin in September 2013. The aim of this document is to summarize the discussions that took place at the ATHOS 2012 and ATHOS 2013 meetings. We do not attempt a comprehensive review of the field of amplitude analysis, but offer a collection of thoughts that we hope may lay the ground for such a document.

43 PARTICLE ACCELERATORS↗

2012 ELECTRONIC SPECTROSCOPY & DYNAMICS GORDON RESEARCH CONFERENCE, JULY 22-27, 2012

Topics covered in this GRC include high-resolution spectroscopy, coherent electronic energy transport in biology, excited state theory and dynamics, excitonics, electronic spectroscopy of cold and ultracold molecules, and the spectroscopy of nanostructures. Several sessions will highlight innovative techniques such as time-resolved x-ray spectroscopy, frequency combs, and liquid microjet photoelectron spectroscopy that have forged stimulating new connections between gas-phase and condensed-phase work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2012 Gordon Research Conference on Vibrational Spectroscopy - Formal Schedule and Speaker/Poster Program

The Vibrational Spectroscopy conference brings together experimentalists and theoreticians working at the frontiers of modern vibrational spectroscopy, with a special emphasis on spectroscopies that probe the structure and dynamics of molecules in gases, liquids, and at interfaces. The conference explores the wide range of state-of-the-art techniques based on vibrational motion. These techniques span the fields of time-domain, high-resolution frequency-domain, spatially-resolved, nonlinear, and multidimensional spectroscopies. The conference highlights both the application of these techniques in chemistry, materials, biology, the environment, and medicine as well as the development of theoretical models that enable one to connect spectroscopic signatures to underlying molecular motions including chemical reaction dynamics. The conference goal is to advance the field of vibrational spectroscopy by bringing together a collection of researchers who share common interests and who will gain from discussing work at the forefront of several connected areas. The intent is to emphasize the insights and understanding that studies of vibrations provide about a variety of molecular systems ranging from small polyatomic molecules to large biomolecules, nanomaterials, and environmental systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical spectroscopy system and method for monitoring liquid phase chemical reactions

A system for monitoring a chemical reaction in a liquid reactor system includes a sample liquid conduit in communication with the liquid reactor system for receiving sample liquid and directing the sample liquid to an optical spectroscopy device, and a laser beam source. The optical spectroscopy device receives the laser beam from the laser source, and guides the laser beam to the sample liquid to generate an optical spectroscopy signal. A detector detects the optical spectroscopy signal and creates a detection signal responsive to the optical spectroscopy signal. A processor processes the detection signal to determine the identity and amount of at least one chemical species in the liquid. A system for continuously sampling a chemical reaction and a method for continuously monitoring and controlling a chemical reaction are also disclosed.

Morales Rodriguez, Marissa E.↗

Raman Spectroscopy

Raman spectroscopy is one of the mostly utilized optical spectroscopic tools for revealing both the catalyst structure and surface chemistry in heterogeneous catalysis. It has recently seen increasing role in catalysis research, thanks to the development of new Raman instrumentations, reactors, and combination with other techniques, leading to in situ and operando studies with significant temporal and spatial resolutions. This chapter aimed to provide a general overview of the applications of Raman spectroscopy in heterogeneous catalysis. It starts with an introduction to the fundamentals of Raman scattering including theory and pros and cons for catalysis research; followed by a description of the typical setup of a Raman system and recent advances in Raman instrumentations; then a chronology of the applications of Raman spectroscopy for ex situ, in situ, and operando studies of catalysis; elucidations of the advances in improving the temporal and spatial resolution of Raman spectroscopy of catalysis; Raman application case studies related to catalyst synthesis, treatments, and function under reaction conditions; illustrations of the power of multimodal approach including Raman spectroscopy in catalysis research; and ended with a brief summary and a future outlook.

Braatz, Jisue↗

Raman Spectroscopy

Raman spectroscopy is one of the mostly utilized optical spectroscopic tools for revealing both the catalyst structure and surface chemistry in heterogeneous catalysis. It has recently seen increasing role in catalysis research, thanks to the development of new Raman instrumentations, reactors, and combination with other techniques, leading to in situ and operando studies with significant temporal and spatial resolutions. This chapter aimed to provide a general overview of the applications of Raman spectroscopy in heterogeneous catalysis. It starts with an introduction to the fundamentals of Raman scattering including theory and pros and cons for catalysis research; followed by a description of the typical setup of a Raman system and recent advances in Raman instrumentations; then a chronology of the applications of Raman spectroscopy for ex situ, in situ, and operando studies of catalysis; elucidations of the advances in improving the temporal and spatial resolution of Raman spectroscopy of catalysis; Raman application case studies related to catalyst synthesis, treatments, and function under reaction conditions; illustrations of the power of multimodal approach including Raman spectroscopy in catalysis research; and ended with a brief summary and a future outlook.

Braatz, Jisue↗

Caught in the H inact : Crystal Structure and Spectroscopy Reveal a Sulfur Bound to the Active Site of an O 2 -stable State of [FeFe] Hydrogenase

[FeFe] hydrogenases are the most active H 2 converting catalysts in nature, but their extreme oxygen sensitivity limits their use in technological applications. The [FeFe] hydrogenases from sulfate reducing bacteria can be purified in an O 2 -stable state called H inact . To date, the structure and mechanism of formation of H inact remain unknown. Our 1.65 Å crystal structure of this state reveals a sulfur ligand bound to the open coordination site. Furthermore, in-depth spectroscopic characterization by X-ray absorption spectroscopy (XAS), nuclear resonance vibrational spectroscopy (NRVS), resonance Raman (RR) spectroscopy and infrared (IR) spectroscopy, together with hybrid quantum mechanical and molecular mechanical (QM/MM) calculations, provide detailed chemical insight into the Hinact state and its mechanism of formation. This may facilitate the design of O 2 -stable hydrogenases and molecular catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of alkali silica reaction gels using Raman spectroscopy

The ability of Raman spectroscopy to characterize amorphous materials makes this technique ideal to study alkali silica reaction (ASR) gels. The structure of several synthetic ASR gels was thoroughly characterized using Raman Spectroscopy. The results were validated with additional techniques such as Fourier transmission infrared spectroscopy, X-ray powder diffraction and thermogravimetric analysis. The Raman spectra were found to have two broad bands in the 800 to 1200 cm{sup −1} range and the 400 to 700 cm{sup −1} range indicating the amorphous nature of the gel. Important information regarding the silicate polymerization was deduced from both of these spectral regions. An increase in alkali content of the gels caused a depolymerization in the silicate framework which manifested in the Raman spectra as a gradual shift of predominant peaks in both regions. The trends in silicate depolymerization were in agreement with results from a NMR spectroscopy study on similar synthetic ASR gels.

36 MATERIALS SCIENCE↗

Multidimensional molecular high-harmonic spectroscopy: A road map for charge migration studies

This work discusses recent experimental and theoretical analyses of high-harmonic spectroscopy in small molecules, with the aim of characterizing charge migration. We discuss the formulation of molecular high-harmonic spectra followed by methods to extract molecular-target-specific information, both in experiments and ab initio simulations. We present measured and simulated high-harmonic spectra from carbon dioxide and carbonyl sulfide to illustrate the necessity for multidimensional analyses for high-harmonic spectroscopies that include both the spectral amplitude and phase. Leveraging these results, we examine how such multidimensional analyses pave the way for the study of charge migration with high-harmonic spectroscopy and illustrate the beneficial role a static molecular feature can play when probing dynamics. Finally, we briefly expand our scope with an outlook on the critical role of integrating theoretical and experimental approaches, beyond just high-harmonic spectroscopy, for the development of versatile harmonic spectroscopic probes of charge migration.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigations on the low voltage cathodoluminescence stability and surface chemical behaviour using Auger and X-ray photoelectron spectroscopy on LiSrBO{sub 3}:Sm{sup 3+} phosphor

Highlights: {yields} Stable orange-red cathodoluminescence observed from LiSrBO{sub 3}:Sm{sup 3+} phosphor. {yields} In situ Auger electron spectroscopy, while monitoring the CL output reduction, reveals surface concentration modification of Li, Sr, B and O atoms. {yields} X-ray photoelectron spectroscopy confirms the formation of SrO{sub 2} layer due to the electron stimulated surface chemical reactions (ESSCRs). This layer is possibly contributing to the surface chemical stability and prevents further degradation. -- Abstract: Orange-red emissive LiSrBO{sub 3}:Sm{sup 3+} phosphors were synthesized through the solid-state reaction method. Under UV radiation (221 nm) and low-voltage electron beam (2 keV, 12 mA/cm{sup 2}) excitation, the Sm{sup 3+} doped LiSrBO{sub 3} phosphor shows emission corresponding to the characteristic {sup 4}G{sub 5/2}-{sup 6}H{sub 7/2} transitions of Sm{sup 3+} with the strongest emission at 601 nm. A high stability of cathodoluminescence (CL) emission during prolong electron bombardment with low-energy electrons was observed. Surface sensitive diagnostic tools such as Auger electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS) were used to study the surface chemistry. AES results revealed modifications in the surface concentrations of Li, Sr, B, O and C on the surface of the LiSrBO{sub 3}:Sm{sup 3+} phosphor as indicated by the changes in their Auger peak to peak heights (APPH) as a function of electron dose. Observed changes in the high resolution XPS spectra of the LiSrBO{sub 3}:Sm{sup 3+} surface irradiated with the low energy electron beam provide evidence of compositional and structural changes as a result of the electron beam stimulated surface chemical reactions (ESSCRs). Additional SrO{sub 2} was identified by XPS on the phosphor surface after it received an electron dose of 300 C/cm{sup 2} together with the increase in the concentrations of chemical species containing the B-C-O bonding. The new surface chemical species formed during electron beam bombardment are possibly responsible for the stability of the CL in the LiSrBO{sub 3}:Sm{sup 3+} phosphor.

36 MATERIALS SCIENCE↗

Spectroscopy investigation of nanostructured nickel–zinc ferrite obtained by mechanochemical synthesis

Highlights: • Nano powder of Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} prepared by a soft mechanochemicaly after 10 h milling. • Phase formation controlled by XRD, Raman and IR spectroscopy. • Spectroscopy measurements indicate that the prepared samples have spinel structure. • The average particles size are found to be around 20 nm. • The degree of inversion is δ = 0.36 for NZF obtained from hydroxides for 10 h. - Abstract: Nano crystalline samples of nickel–zinc ferrite, Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} were prepared by mechanochemical route in a planetary ball mill starting from two mixtures of the appropriate quantities of the powders: case (1) oxide powders: NiO, ZnO and α-Fe{sub 2}O{sub 3} in one case, and in the second case (2) hydroxide powders: Ni(OH){sub 2}, Zn(OH){sub 2} and Fe(OH){sub 3}. In order to monitor the progress of chemical reaction and confirm phase formation, powder samples obtained after 5 h and 10 h of milling were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), Raman, IR and Mössbauer spectroscopy. It is shown that the soft mechanochemical method, i.e. mechanochemical activation of hydroxides, produces high quality single phase Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} samples in much more efficient way. From the IR spectroscopy of single phase samples it is obvious that energy of modes depends on the ratio of cations. The deconvolution of Raman spectra allows to separate contributions of different cations to a particular type of vibration and to estimate the degree of inversion.

36 MATERIALS SCIENCE↗

In-gas-jet laser spectroscopy with S 3 -LEB

The Super Separator Spectrometer-Low Energy Branch (S 3 -LEB) is a low-energy radioactive ion beam experiment under commissioning as part of the GANIL-SPIRAL2 facility. It will be used for the production and study of exotic nuclei by in-gas laser ionization and spectroscopy (IGLIS), decay spectroscopy, and mass spectrometry. Here, we report recent results from the off-line commissioning of S 3 -LEB, including first laser spectroscopy measurements in both the gas cell and the supersonic gas jet, the determination of the transport efficiency of laser ions from the gas cell through the RFQ chain, and time-of-flight measurements with the multi-reflection time-of-flight mass spectrometer PILGRIM. The measurements were performed using erbium, introduced by evaporation from a heated filament in the gas environment. The reported laser spectroscopy results include a characterization of the pressure broadening in the gas cell, proof-of-principle isotope shift measurements, and hyperfine-structure measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonance Raman and surface- and tip-enhanced Raman spectroscopy methods to study solid catalysts and heterogeneous catalytic reactions.

Resonance Raman (RR) spectroscopy has several advantages over the normal Raman spectroscopy (RS) widely used for in situ characterization of solid catalysts and catalytic reactions. Compared with RS, RR can provide much higher sensitivity and selectivity in detecting catalytically-significant surface metal oxides. RR can potentially give useful information on the nature of excited states relevant to photocatalysis and on the anharmonic potential of the ground state. In this critical review a detailed discussion is presented on several types of RR experimental systems, three distinct sources of so-called Raman (fluorescence) background, detection limits for RR compared to other techniques (EXAFS, PM-IRAS, SFG), and three well-known methods to assign UV-vis absorption bands and a band-specific unified method that is derived mainly from RR results. In addition, the virtues and challenges of surface-enhanced Raman spectroscopy (SERS) are discussed for detecting molecular adsorbates at catalytically relevant interfaces. Tip-enhanced Raman spectroscopy (TERS), which is a combination of SERS and near-field scanning probe microscopy and has the capability of probing molecular adsorbates at specific catalytic sites with an enormous surface sensitivity and nanometre spatial resolution, is also reviewed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗