Comparison of Data Quality of NOAA's ISIS and SURFRAD Networks to NREL's SRRL-BMS

This report provides analyses of broadband solar radiometric data quality for the National Oceanic and Atmospheric Administration's Integrated Surface Irradiance Study and Surface Radiation Budget Network (SURFRAD) solar measurement networks. The data quality of these networks is compared to that of the National Renewable Energy Laboratory's Solar Radiation Research Laboratory Baseline Measurement System (SRRL-BMS) native data resolutions and hourly averages of the data from the years 2002 through 2013. This report describes the solar radiometric data quality testing and flagging procedures and the method used to determine and tabulate data quality statistics. Monthly data quality statistics for each network were plotted by year against the statistics for the SRRL-BMS. Some of the plots are presented in the body of the report, but most are in the appendix. These plots indicate that the overall solar radiometric data quality of the SURFRAD network is superior to that of the Integrated Surface Irradiance Study network and can be comparable to SRRL-BMS.

14 SOLAR ENERGY↗

DOE-RCT-0003641 Final Technical Report

This program studied novel concepts for an Axial Flux Reluctance Machine to capture energy from marine hydrokinetic sources and compared their attributes to a Radial Flux Reluctance Machine which was designed under a prior Department of Energy program for the same application. Detailed electromagnetic and mechanical analyses were performed to determine the validity of the concept and to provide a direct comparison with the existing conventional Radial Flux Switched Reluctance Machine designed during the Advanced Wave Energy Conversion Project, DE-EE0003641. The alternate design changed the machine topology so that the flux that is switched flows axially rather than radially and the poles themselves are long radially, as opposed to the radial flux machine that has pole pieces that are long axially. It appeared possible to build an axial flux machine that should be considerably more compact than the radial machine. In an “apples to apples” comparison, the same rules with regard to generating magnetic force and the fundamental limitations of flux density hold, so that at the heart of the machine the same torque equations hold. The differences are in the mechanical configuration that limits or enhances the change of permeance with rotor position, in the amount of permeable iron required to channel the flux via the pole pieces to the air-gaps, and in the sizing and complexity of the electrical winding. Accordingly it was anticipated that the magnetic component weight would be similar but that better use of space would result in a shorter machine with accompanying reduction in housing and support structure. For the comparison the pole count was kept the same at 28 though it was also expected that the radial tapering of the slots between pole pieces would permit a higher pole count machine, enabling the generation of greater power at a given speed in some future design. The baseline Radial Flux Machine design was established during the previous DOE program. Its characteristics were tabulated for use in comparing to the Axial Flux Machine. Three basic conceptual designs for the Axial Flux Machine were considered: (1) a machine with a single coil at the inner diameter of the machine, (2) a machine with a single coil at the outside diameter of the machine, and (3) a machine with a coil around each tooth. Slight variations of these basic configurations were considered during the study. Analysis was performed on these configurations to determine the best candidate design to advance to preliminary design, based on size, weight, performance, cost and manufacturability. The configuration selected as the most promising was the multi-pole machine with a coil around each tooth. This configuration provided the least complexity with respect to the mechanical configuration and manufacturing, which would yield the highest reliability and lowest cost machine of the three options. A preliminary design was performed on this selected configuration. For this first ever axial design of the multi rotor configuration the 'apples to apples' comparison was based on using the same length of rotor pole as the axial length of rotor pole in the radial machine and making the mean radius of the rotor in the axial machine the same as the air gap radius in the radial machine. The tooth to slot ratio at the mean radius of the axial machine was the same as the tooth to slot ratio of the radial machine. The comparison between the original radial flux machine and the new axial flux machine indicates that for the same torque, the axial flux machine diameter will be 27% greater, but it will have 30% of the length, and 76% of the weight. Based on these results, it is concluded that an axial flux reluctance machine presents a viable option for large generators to be used for the capture of wave energy. In the analysis of Task 4, below, it is pointed out that our selection of dimensional similarity for the 'apples to apples' comparison did not produce an optimum axial flux design. There is torque capability to spare, implying we could reduce the magnetic structure, but the winding area, constrained by the pole separation at the inner pole radius has a higher resistance than desirable, implying we need more room for copper. The recommendation is to proceed via one cycle of optimization and review to correct this unbalance and then proceed to a detailed design phase to produce manufacturing drawings, followed by the construction of a prototype to test the performance of the machine against predicted results.

16 TIDAL AND WAVE POWER↗

Lightweight Materials for Automotive Application: An Assessment of Material Production Data for Magnesium and Carbon Fiber

The use of lightweight materials in vehicle components, also known as “lightweighting,” can result in automobile weight reduction, which improves vehicle fuel economy and generally its environmental footprint. Materials often used for vehicle lightweighting include aluminum, magnesium, and polymers reinforced with either glass or carbon fiber. However, because alternative materials typically used for vehicle lightweighting require more energy to make on a per part basis than the material being replaced (often steel or iron), the fuel efficiency improvement induced by a weight reduction is partially offset by an increased energy for the vehicle material production. To adequately quantify this tradeoff, reliable and current values for life-cycle production energy are needed for both conventional and alternative materials. Our focus here is on the production of two such alternative materials: magnesium and carbon fibers. Both these materials are low density solids with good structural properties. These properties have enabled their use in applications where weight is an issue, not only for automobiles but also for aerospace applications. This report addresses the predominant production methods for these materials and includes a tabulation of available material and energy input data necessary to make them. The life cycle inventory (LCI) information presented herein represents a process chain analysis (PCA) approach to life cycle assessment (LCA) and is intended for evaluation as updated materials production data for magnesium and carbon fiber for inclusion into the Greenhouse gases, Regulated Emissions, and Energy use in Transportation model (GREET2_2012). The summary life-cycle metrics used to characterize the cradle-to-gate environmental performance of these materials are the cumulative energy demand (CED) and greenhouse gas emissions (GHG) per kilogram of material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defect reaction network in Si-doped InAs. Numerical predictions.

This Report characterizes the defects in the defect reaction network in silicon-doped, n-type InAs predicted with first principles density functional theory. The reaction network is deduced by following exothermic defect reactions starting with the initially mobile interstitial defects reacting with common displacement damage defects in Si-doped InAs, until culminating in immobile reaction products. The defect reactions and reaction energies are tabulated, along with the properties of all the silicon-related defects in the reaction network. This Report serves to extend the results for the properties of intrinsic defects in bulk InAs as collated in SAND 2013 - 2477: ''Simple intrinsic defects in InAs : numerical predictions'' to include Si-containing simple defects likely to be present in a radiation-induced defect reaction sequence.

36 MATERIALS SCIENCE↗

Characterization Results for the 2014 HTF 3H & 2H Evaporator Overhead Samples

This report tabulates the radiochemical analysis of the 3H and 2H evaporator overhead samples for 137 Cs, 90 Sr, and 129 I to meet the requirements in the Effluent Treatment Project (ETP) Waste Acceptance Criteria (WAC) (rev. 6). This report identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. All data was found to be within the ETP WAC (rev. 6) specification for the Waste Water Collection Tanks (WWCT).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annex C. Data Libraries for IAEA Nuclear Security Assessment Methodologies (NUSAM)

Data Libraries are a collection of experimental data for PP elements based on specific defeat mechanisms. The data can de related to probability of detection, assessment, or barrier delay times. The data libraries can be a manually tabulated list or an electronic menu values enbedded in a stand-alone database or in an assessment software program such as SAVI or EASI. Data library values are usually based on years of historical testing data for many forms of common and sometimes unique PPS systems. Most useful testing libraries include data from the most basic alarm sensors, doors, walls, and barriers to very sophisticated PP elements. Each PP element is tested using increasing levels of defeat techniques from hand tools, power tools, breaching tools, explosives, and vehicles, as applicable.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Northeast Solid-State Lighting Strategic Information Network

This report summarizes results of a survey developed and issued by Northeast Energy Efficiency Partnerships (NEEP) to “assess the reach and impact of NEEP’s SSL information dissemination” undertaken as part of its Technical Information Network for Solid State Lighting (TINSSL) project1. Survey results will be used to develop recommendations to optimize project effectiveness, both for NEEP and the U.S. Department of Energy (DOE). Furthermore, completion of the 2008 and 2009 surveys fulfills the requirements of the funding agreement supporting the NEEP TINSSL project. Since this is the second of two surveys, comparisons from year to year are presented. The NEEP TINSSL Stakeholder Survey was developed using Surveymonkey and it was distributed via email on May 19, 2009 and May 26, 2009. It was also distributed at a kiosk via internet at the NEEP Summit on May 29, 2009 and was closed that evening. Response to the survey increased by 35 percent this year. Eighty-six respondents completed the survey, and 104 responded overall. In an effort to increase response, this year respondents were invited to participate in a raffle for an SSL lighting product. The survey was distributed to the NEEP TINSSL distribution list, which includes a diverse set of contacts that overlaps significantly with NEEP’s general distribution list. The report presents 2009 findings and comparisons with 2008, where appropriate, on respondents’ awareness and understanding of SSL technology as well as their awareness of NEEP, DOE and other information resources.2 This includes NEEP’s many, varied outreach venues that communicate about SSL as part of TINSSL. In addition, it presents findings from questions addressing information needed by program planners. In addition to the summary findings reported below, a spreadsheet with a question-by-question tabulation of survey responses and a full listing of verbatim responses is included as an attachment to this report.

Schmidt, Ed↗

Results Of Hg Speciation Testing On DWPF SMECT-1, SMECT-3, And SMECT-5 Samples

The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The thirteenth shipment of samples was designated to include Defense Waste Processing Facility (DWPF) Slurry Mix Evaporator Condensate Tank (SMECT) from Sludge Receipt and Adjustment Tank (SRAT) Batch 736 and 738 samples. Triplicate samples of each material were prepared for this shipment. Each replicate was analyzed for seven Hg species: total Hg, total soluble (dissolved) Hg, elemental Hg [Hg(0)], ionic (inorganic) Hg [Hg(I) and Hg(II)], methyl Hg [CH 3 Hg-X, where X is a counter anion], ethyl Hg [CH 3 CH 2 -Hg-X, where X is a counter anion], and dimethyl Hg [(CH 3 ) 2 Hg]. The difference between the total Hg and total soluble Hg measurements gives the particulate Hg concentration, i.e. Hg adsorbed to the surface of particulate matter in the sample but without resolution of the specific adsorbed species. The average concentrations of Hg species in the aqueous samples derived from Eurofins reported data corrected for dilutions performed by SRNL are tabulated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Fourth Quarter Calendar Year 2015 Tank 50H Salt Solution Sample

In this memorandum, the chemical and radionuclide contaminant results from the Fourth Quarter Calendar Year 2015 (CY15) sample of Tank 50H salt solution are presented in tabulated form. The Fourth Quarter CY15 Tank 50H samples were obtained on October 29, 2015 and received at Savannah River National Laboratory (SRNL) on October 30, 2015. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Salt Feed Tank in the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Fourth Quarter Calendar Year 2015 (CY15) sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of the ambient gamma dose equivalent and kerma from the small 252 Cf source at 1 meter and the small 60 Co source at 2 meters

NASA Langley Research Center requested a measurement and determination of the ambient gamma dose equivalent rate and kerma at 100 cm from the 252 Cf source and determination of the ambient gamma dose equivalent rate and kerma at 200 cm from the 60 Co source for the Radiation Budget Instrument Experiment (Rad-X). An Exradin A6 ion chamber with Shonka air-equivalent plastic walls in combination with a Supermax electrometer were used to measure the exposure rate and free-in-air kerma rate of the two sources at the requested distances. The measured gamma exposure, kerma, and dose equivalent rates are tabulated.

07 ISOTOPE AND RADIATION SOURCES↗

Technical Reports - FY16 Q1 - October-December 2015

Recent experiments have demonstrated that the frequency dependence of motional heating rates in ion traps can vary dramatically with temperature.1-6 More specifically, it has been shown that, at temperatures below roughly 70 K, heating rates are substantially lower than those observed at temperatures above 70 K.1,2 These observations, combined with experiments that show that ion bombardment may also reduce heating rates,4,5 suggest that one potential source of heating may be the presence of unwanted adatoms on trap surfaces. Based upon this evidence, this past quarter, we have used our previously detailed microscopic model of anomalous heating to study which adatoms may be responsible for the observed temperature-dependent scaling of motional heating rates with frequency. We have also examined the validity of one of the key assumptions in our model - that surface adatom dipoles can be accurately obtained from a variational ansatz - by using more direct DFT calculations of the dipole moments. Our current results suggest that the adatoms potentially responsible for the observed motional heating rates should bind weakly to the electrode surface and likely have a mass that exceeds that of Ne. Preliminary DFT calculations suggest that an analytical adatom dipole model,9 previously used in the ion trap noise literature7 to obtain the dipole as a function of adatom-surface distance, may be insufficiently accurate. Therefore, we are working toward obtaining a tabulation of the distance-dependent dipole for several adsorbates using first principles calculations for more accurate input to the heating model. The accurate calculation of the adatom dipole is important because its fluctuation is what couples to and heats the trapped ion qubit. Future work will focus on calculating the frequency spectra of a variety of hydrocarbons, which should have the binding characteristics identified below as necessary for reproducing experimental results. Upcoming efforts will moreover be directed toward deriving an improved microscopic model of heating which will enable direct comparisons of heating rates with measured ion-surface distances and will more accurately account for experimental parameters such as the trapping frequency, ion-electrode distance, and RF power applied to the electrodes.

36 MATERIALS SCIENCE↗

Results For The Third Quarter Calendar Year 2016 Tank 50H Salt Solution Sample

In this memorandum, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2016 (CY16) sample of Tank 50H salt solution are presented in tabulated form. The Third Quarter CY16 Tank 50H samples (a 200 mL sample obtained 6” below the surface (HTF-5-16-63) and a 1 L sample obtained 66” from the tank bottom (HTF-50-16-64)) were obtained on July 14, 2016 and received at Savannah River National Laboratory (SRNL) on the same day. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours, and the samples were pulled immediately after pump shut down. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Third Quarter CY16 sampling of Tank 50H were requested by Savannah River Remediation (SRR) personnel and details of the testing are presented in the SRNL TTQAP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Properties of G-348 Graphite

Fundamental measurements have been obtained in the INL Graphite Characterization Laboratory to deduce the temperature dependence of thermal conductivity for G-348 isotropic graphite, which has been used by City College of New York in thermal experiments related to gas-cooled nuclear reactors. Measurements of thermal diffusivity, mass, volume and thermal expansion were converted to thermal conductivity in accordance with ASTM Standard Practice C781-08. Data are tabulated and a preliminary correlation for the thermal conductivity is presented as a function of temperature from laboratory temperature to 1000C.

36 MATERIALS SCIENCE↗

Fermilab Testbeam Facility Annual Report – FY 2016

This Technical Memorandum (TM) summarizes the Fermilab Test Beam operations for FY 2015. It is one of a series of annual publications intended to gather information in one place. In this case, the information concerns the individual experiments that ran at FTBF, which are tabulated. Each experiment section was prepared by the relevant authors, and was edited for inclusion in this summary.

43 PARTICLE ACCELERATORS↗

Fluxes of CO 2 , CH 4 , CO, BVOCs, NOx, and O 3 in an Old Growth Amazonian Forest: Ecosystem Processes, Carbon Cycle, Atmospheric Chemistry, and Feedbacks on Climate

A comprehensive, merged data set of trace gases (NO, NO 2 , CO 2 , CH 4 and O 3 ) along with has been tabulated and subjected to meticulous quality assurance and quality control (QA/QC). The merged data set is being submitted to the ARM website dedicated to the Green Ocean Experiment: https://www.arm.gov/research/campaigns/amf2014goamazon Analysis using the final data set is in progress to determine the magnitudes of the fluxes for CH 4 , H 2 O, CO 2 , O 3 , NO x , sensible and latent heat, momentum, and their seasonal variations. Here are summary statements, from the discussion above: Total NO fluxes were calculated following Keller et al., 1986. A vertical gradient is established in the mixing ratio of NO because it is emitted at the soil surface and mixed upward in the atmosphere (see above). Once in the atmosphere, the NO reacts rapidly with O 3 to produce NO 2 (NO + O 3 → NO 2 + O 2 ). Therefore, if the vertical profiles of the mixing ratios of NO and O 3 are known, the surface flux of NO may be determined. If any other reaction removes NO (e.g., deposition on leaves), FNO should estimate the lower limit to the NO flux from the soil in this forest. Our preliminary results show fluxes of NO averaged 133 x 10 9 molecules cm -2 s -1 , a factor of 4 higher than fluxes previously observed in white sand soils in the Amazon, and a factor of 3 to 14 higher than fluxes observed for yellow clay soils (Bakwin et al., 1990 and references therein). The soil in the km 67 site is predominately oxisol with pockets of sandy ultisols, both having low reduced nutrient contents, mostly due to efficient microorganism decomposition and acid leaching by rain water. Oxisols contain both oxidized and reduced forms of nitrogen, of which concentrations vary independently of leaching (Jordan et al., 1982), with most part of the cycling processes occurring in the top layers. Methane fluxes showed no statistical difference between 2015 wet and dry seasons, and the forest at this site appear to be a methane sink throughout the year. The vertical profiles suggest that if a methane source exists in this forest, it might be in the canopy. Next steps include modeling and analysis using the Master Chemical Mechanism (Jenkin et al., 1997; Saunders et al., 2003 (A/B); http://mcm.leeds.ac.uk/MCM/) and the Ecosystem Demography-2 (ED-2) model. A final manuscript with the results from this work is in preparation and expected to be submitted for publication within the next several months. Publications to date are listed below.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Results for the first quarter calendar year 2017 tank 50H salt solution sample

In this memorandum, the chemical and radionuclide contaminant results from the First Quarter Calendar Year 2017 (CY17) sample of Tank 50H salt solution are presented in tabulated form. The First Quarter CY17 Tank 50H samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-7) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-8)] were obtained on January 15, 2017 and received at Savannah River National Laboratory (SRNL) on January 16, 2017. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours and the samples were pulled immediately after pump shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. The chemical and radionuclide contaminant results from the characterization of the First Quarter CY17 sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan (TTQAP). This memorandum is part of Deliverable 2 from SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50H saltstone task.