Search NASA⌕ Search

SEARCH · Search NASA

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Possibility of X-ray spectral diagnostics of a plasma in the tracks of fast multicharged ions

A plasma model of the relaxation of a medium within the tracks of heavy ions in condensed matter is proposed that is based on solving time-dependent radiative collisional kinetic equations with the initial condition corresponding to a medium's state described by the classical model of multiple ionization of the target atoms by the field of fast multicharged ions. It is shown that the plasma model allows one to describe X-ray spectra recorded in the interaction of ion beams with condensed targets. An X-ray spectral method for plasma diagnostics is proposed that is based on the plasma model. The results obtained can also be used to study the initial stage of the formation of defects in solid bodies under the action of individual fast heavy ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of Electromagnetic Transponder Use to Monitor Inter- and Intrafractional Motion in Locally Advanced Pancreatic Cancer Patients

Purpose: The primary objective of this study was to determine the feasibility of electromagnetic transponder implantation in patients with locally advanced unresectable pancreatic cancer. Secondarily, the use of transponders to monitor inter- and intrafractional motion, and the efficacy of breath holding for limiting target motion, were examined. Methods and Materials: During routine screening laparoscopy, 5 patients without metastatic disease were implanted with transponders peri-tumorally. The Calypso System's localization and tracking modes were used to monitor inter- and intrafractional motion, respectively. Intrafractional motion, with and without breath holding, was also examined using Calypso tracking mode. Results: Transponder implantation was well tolerated in all patients, with minimal migration, aside from 1 patient who expulsed a single transponder. Interfractional motion based on mean shifts from setup using tattoos/orthogonal imaging to transponder based localization from 164 treatments was significant in all dimensions. Mean shift (in millimeters), followed by the standard deviation and p value, were as follows: X-axis: 4.5 mm (1.0, p = 0.01); Y axis: 6.4 mm (1.9, p = 0.03); and Z-axis 3.9 mm (0.6, p = 0.002). Mean intrafractional motion was also found to be significant in all directions: superior, 7.2 mm (0.9, p = 0.01); inferior, 11.9 mm (0.9, p < 0.01); anterior: 4.9 mm (0.5, p = 0.01); posterior, 2.9 mm (0.5, p = 0.02); left, 2.2 mm (0.4, p = 0.02); and right, 3.1 mm (0.6, p = 0.04). Breath holding during treatment significantly decreased tumor motion in all directions. Conclusions: Electromagnetic transponder implantation appears to be safe and effective for monitoring inter- and intrafractional motion. Based on these results a larger clinical trial is underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Dosimetric Impact of Prostate Rotations During Electromagnetically Guided External-Beam Radiation Therapy

Purpose: To study the impact of daily rotations and translations of the prostate on dosimetric coverage during radiation therapy (RT). Methods and Materials: Real-time tracking data for 26 patients were obtained during RT. Intensity modulated radiation therapy plans meeting RTOG 0126 dosimetric criteria were created with 0-, 2-, 3-, and 5-mm planning target volume (PTV) margins. Daily translations and rotations were used to reconstruct prostate delivered dose from the planned dose. D{sub 95} and V{sub 79} were computed from the delivered dose to evaluate target coverage and the adequacy of PTV margins. Prostate equivalent rotation is a new metric introduced in this study to quantify prostate rotations by accounting for prostate shape and length of rotational lever arm. Results: Large variations in prostate delivered dose were seen among patients. Adequate target coverage was met in 39%, 65%, and 84% of the patients for plans with 2-, 3-, and 5-mm PTV margins, respectively. Although no correlations between prostate delivered dose and daily rotations were seen, the data showed a clear correlation with prostate equivalent rotation. Conclusions: Prostate rotations during RT could cause significant underdosing even if daily translations were managed. These rotations should be managed with rotational tolerances based on prostate equivalent rotations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-molecule live-cell RNA imaging with CRISPR–Csm

Abstract Understanding the diverse dynamic behaviors of individual RNA molecules in single cells requires visualizing them at high resolution in real time. However, single-molecule live-cell imaging of unmodified endogenous RNA has not yet been achieved in a generalizable manner. Here, we present single-molecule live-cell fluorescence in situ hybridization (smLiveFISH), a robust approach that combines the programmable RNA-guided, RNA-targeting CRISPR–Csm complex with multiplexed guide RNAs for direct and efficient visualization of single RNA molecules in a range of cell types, including primary cells. Using smLiveFISH, we track individual nativeNOTCH2andMAP1Btranscripts in living cells and identify two distinct localization mechanisms including the cotranslational translocation ofNOTCH2mRNA at the endoplasmic reticulum and directional transport ofMAP1BmRNA toward the cell periphery. This method has the potential to unlock principles governing the spatiotemporal organization of native transcripts in health and disease.

Biotechnology & Applied Microbiology↗

Measurement of Neutrino Absolute Deep Inelastic Scattering Cross Section in Iron, Lead, Carbon, and Plastic Using MINERvA Detector at $E_{\nu} = 6$ \GeV

A deep inelastic sample is selected from the nuclear charged current inclusive analysis, by requiring reconstructed $Q^{2} \geq 1.0$ (GeV/c)$^{2}$ and $W \geq 2.0$ GeV/c$^{2}$. The neutrino energy range of $5 < E_{\nu} < 50$ previously applied to this analysis in the Low Energy (LE) analysis is removed and the energy range cut is imposed on the muon energy from $2 < E_{\mu} < 50$ GeV. Machine learning vertexing is used to improve the track-based vertexing resulting in higher purity and efficiency of the sample. A local sideband method is utilized to remove the plastic background for the events reconstructed in the target. After plastic backgrounds and non-DIS backgrounds are subtracted, the reconstructed neutrino energy and Bjorken-x are unsmeared to their true quantities via Bayesian unfolding. The unfolded distributions of carbon, iron, lead, and plastic are efficiency corrected and then divided by the flux and the number of nucleons in the target to produce the absolute cr oss section as a function of $E_{\nu}$ and differential cross section as function of $x_{bj}$. The results of the analysis show good agreement between data and MC for $E_{\nu}$ and $x_{bj}$ (see Figures \ref{fig:xsecEnuC} through \ref{fig:xsecXCH}). None of the distributions displayed significant differences with the theoretical models underlying MINERvAs MC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Localization Method for Remotely Operated Robot in Harsh Environments - 18561

For decommissioning of the Fukushima Daiichi Nuclear Power Station (FDNPS), the primary containment vessel (PCV) internal survey for fuel debris spreading has been needed. Remotely operated robots have been used for the survey. Localization of the robots during their operation is necessary to adjust sensor positions. However, it is difficult to calculate the robot position because the survey target areas have an unknown environment. In this research, we proposed a localization method which combines a stereo camera-based method for absolute localization and a periodic structure tracking method for relative localization for application to the unknown environment. The position accuracy for the proposed method was verified in a mock-up test, and we confirmed that the position accuracy satisfied the required accuracy of 30 mm. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-279: Realization of Three-Dimensional Conformal Dose Planning in Prostate Brachytherapy

Purpose: Successful clinical treatment in prostate brachytherapy is largely dependent on the effectiveness of pre-surgery dose planning. Conventional dose planning method could hardly arrive at a satisfy result. In this abstract, a three-dimensional conformal localized dose planning method is put forward to ensure the accuracy and effectiveness of pre-implantation dose planning. Methods: Using Monte Carlo method, the pre-calculated 3-D dose map for single source is obtained. As for multiple seeds dose distribution, the maps are combined linearly to acquire the 3-D distribution. The 3-D dose distribution is exhibited in the form of isodose surface together with reconstructed 3-D organs group real-timely. Then it is possible to observe the dose exposure to target volume and normal tissues intuitively, thus achieving maximum dose irradiation to treatment target and minimum healthy tissues damage. In addition, the exfoliation display of different isodose surfaces can be realized applying multi-values contour extraction algorithm based on voxels. The needles could be displayed in the system by tracking the position of the implanted seeds in real time to conduct block research in optimizing insertion trajectory. Results: This study extends dose planning from two-dimensional to three-dimensional, realizing the three-dimensional conformal irradiation, which could eliminate the limitations of 2-D images and two-dimensional dose planning. A software platform is developed using VC++ and Visualization Toolkit (VTK) to perform dose planning. The 3-D model reconstruction time is within three seconds (on a Intel Core i5 PC). Block research could be conducted to avoid inaccurate insertion into sensitive organs or internal obstructions. Experiments on eight prostate cancer cases prove that this study could make the dose planning results more reasonable. Conclusion: The three-dimensional conformal dose planning method could improve the rationality of dose planning by safely reducing the large target margin and avoiding dose dead zones for prostate cancer treatment. 1) National Natural Science Foundation of People's Republic of China (No. 51175373); 2) New Century Educational Talents Plan of Chinese Education Ministry (NCET-10-0625); 3) Scientific and Technological Major Project, Tianjin (No. 12ZCDZSY10600)

60 APPLIED LIFE SCIENCES↗

SU-E-T-150: End to End Tests On the First Clinical EDGETM

Purpose: To quantify the sub millimeter overall accuracy of EDGETM, the dedicated linac based SRS/SABR treatment platform from Varian, using a novel End-to-End (E2E) test phantom. Methods: The new E2E test phantom developed by Varian consists of a cube with an outer dimension of 15x15x15 cm3. The phantom is equipped with an exchangable inner cube (7×7×7 cm3) to hold radiochromic films or a tungsten ball (diameter = 5 mm) for Winston-Lutz tests. 16 ceramic balls (diameter = 5 mm) are embedded in the outer cube. Three embedded Calypso transponders allow for Calypso based monitoring. The outer surface of the phantom is tracked using the Optical Surface Monitoring System (OSMS). The phantom is positioned using kV, MV and CBCT images. A simCT of the phantom was acquired and SRS/SABR plans were treated using the new phantom on the first clinical installed EDGETM. As a first step a series of EPID based Winston-Lutz tests have been performed. As a second step the calculated dose distribution applied to the phantom was verified with radiochromic films in orthogonal planes. The measured dose distribution is compared with the calculated (Eclipse) one based on the known isocenter on both dose distributions. The geometrical shift needed to match both dose distributions is the overall accuracy and is determined using dose profiles, isodose lines or gamma pass rates (3%, 1 mm). Results: Winston-Lutz tests using the central tungsten BB demonstrated a targeting accuracy of 0.44±0.18mm for jaw (2cm × 2cm) defined 0.39±0.19mm for MLC (2cm × 2cm) defined and 0.37±0.15mm for cone (12.5 mm) defined fields. A treated patient plan (spinal metastases lesion with integrated boost) showed a dosimetric dose localization accuracy of 0.6mm. Conclusion: Geometric and dosimetric E2E tests on EDGETM, show sub-millimeter E2E targeting and dose localisation accuracy.

60 APPLIED LIFE SCIENCES↗

Revealing protonation states and tracking substrate in serine hydroxymethyltransferase with room-temperature X-ray and neutron crystallography

Pyridoxal 5’-phosphate (PLP)-dependent enzymes utilize a vitamin B 6 -derived cofactor to perform a myriad of chemical transformations on amino acids and other small molecules. Some PLP-dependent enzymes, such as serine hydroxymethyltransferase (SHMT), are promising drug targets for the design of small-molecule antimicrobials and anticancer therapeutics, while others have been used to synthesize pharmaceutical building blocks. Understanding PLP-dependent catalysis and the reaction specificity is crucial to advance structure-assisted drug design and enzyme engineering. Here we report the direct determination of the protonation states in the active site of Thermus thermophilus SHMT (TthSHMT) in the internal aldimine state using room-temperature joint X-ray/neutron crystallography. Conserved active site architecture of the model enzyme TthSHMT and of human mitochondrial SHMT (hSHMT2) were compared by obtaining a room-temperature X-ray structure of hSHMT2, suggesting identical protonation states in the human enzyme. The amino acid substrate serine pathway through the TthSHMT active site cavity was tracked, revealing the peripheral and cationic binding sites that correspond to the pre-Michaelis and pseudo-Michaelis complexes, respectively. At the peripheral binding site, the substrate is bound in the zwitterionic form. By analyzing the observed protonation states, Glu53, but not His residues, is proposed as the general base catalyst, orchestrating the retro-aldol transformation of L-serine into glycine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonequilibrium Nonideal Nanoplasma Generated by a Fast Single Ion in Condensed Matter

A plasma model of relaxation of a medium in heavy ion tracks in condensed matter is proposed. The model is based on three assumptions: the Maxwell distribution of plasma electrons, localization of plasma inside the track nanochannel and constant values of the plasma electron density and temperature during the X-ray irradiation. It is demonstrated that the plasma relaxation model adequately describes the X-ray spectra observed upon interaction of a fast ion with condensed target. Preassumptions of plasma relaxation model are validated by the molecular dynamics modeling and simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffraction dissociation of {sup 7}Li and {sup 7}Be relativistic nuclei on proton targets through the {sup 3}H({sup 3}He)+{sup 4}He channels

For the fragmentation of {sup 7}Li and {sup 7}Be relativistic nuclei (with momenta of, respectively, P = 3 GeV/c and P = 1.6 GeV/c per nucleon) on proton targets through the {sup 3}H({sup 3}He) + {sup 4}He channels, the differential cross sections with respect to the momentum transfer Q to the fragments were calculated on the basis of the cluster version of Akhiezer–Glauber–Sitenko diffraction theory by employing the twobody cluster model for the {sup 7}Li ({sup 3}H + {sup 4}He) and {sup 7}Be ({sup 3}He + {sup 4}He) nuclei. These calculations, performed in the impulse approximation in the interaction of intranuclear clusters with the target nucleus, explained a strong suppression of the cross sections for reactions on protons at Q lower than 100 MeV/c and higher than 350 MeV/c and the observed irregularities in the behavior off the cross section for {sup 7}Li fragmentation on complex track-emulsion nuclei. Cross-section values close to their experimental counterparts were obtained upon setting the coefficient of two-body clustering in the {sup 7}Li and {sup 7}Be nuclei to k ≃ 0.7.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TU-AB-201-04: Optimizing the Number of Catheter Implants and Their Tracks for Prostate HDR Brachytherapy

Purpose: In prostate HDR brachytherapy, interstitial implants are placed manually on the fly. The aim for this research is to develop a computer algorithm to find optimal and reliable implant trajectories using minimal number of implants. Methods: Our new algorithm mainly uses these key ideas: (1) positive charged static particles are uniformly placed on the surface of prostate and critical structures such as urethra, bladder, and rectum. (2) Positive charged kinetic particles are placed at a cross-section of the prostate with an initial velocity parallel to the principal implant direction. (3) The kinetic particles move through the prostate, interacting with each other, spreading out, while staying away from the prostate surface and critical structures. The initial velocity ensures that the trajectories observe the curvature constraints of typical implant procedures. (4) The finial trajectories of kinetic particles are smoothed using a third-degree polynomial regression, which become the implant trajectories. (5) The dwelling times and final dose distribution are calculated using least-distance programming. Results: (1) We experimented with previously treated cases. Our plan achieves all prescription goals while reducing the number of implants by 41%! Our plan also has less uniform target dose, which implies a higher dose is delivered to the prostate. (2) We expect future implant procedures will be performed under the guidance of such pre-calculated trajectories. To assess the applicability, we randomly perturb the tracks to mimic the manual implant errors. Our studies showed the impact of these perturbations are negligible, which is compensated by the least distance programming. Conclusions: We developed a new inverse planning system for prostate HDR therapy that can find optimal implant trajectories while minimizing the number of implants. For future work, we plan to integrate our new inverse planning system with an existing needle tracking system.

60 APPLIED LIFE SCIENCES↗

Induction of α6 and β1 integrins by acupuncture stimulation in rats

Acupuncture therapy is performed by applying the needle insertion at discrete cutaneous locations and used for the treatments of diverse symptoms and disorders. In order to elucidate mechanistic basis on how acupuncture stimulation (AS) produces therapeutic effects, it is primarily important to understand tissue responses locally at the acupuncture site (acupoint). Here, we investigated integrin protein as molecular target responding to and integrating AS. Signals of α6 and β1 integrins were clearly induced at zusanli acupoint 24 h after AS in areas of nuclear clusters around the needle track. Induction levels of integrin were largely reduced by needle insertion at non-acupuncture point or without needle rotation. Phospho-Erk1/2 was initially decreased below the basal level after AS but increased 24 h later. Induction pattern of phospho-Erk1/2 was as similar as that of α6 integrin in its selectivity to needling procedure and tissue distribution. We further found that mRNA expression of P2X3 purinergic receptor was upregulated in the dorsal root ganglion (DRG) after AS, but decreased by the inhibition of Erk1/2 activity at the acupuncture area. Moreover, AS-mediated integrin activation was required for Erk1/2 activation at the acupuncture site and regulation of pain sensitivity in the hind paw. The present results provide a new evidence on acupuncture-specific tissue response in terms of integrin induction, and further suggest that integrin activation may be involved in transmitting mechanosensory signals from the acupoint to afferent nerve fiber. - Highlights: • We investigated local tissue responses after acupuncture stimulation (AS) in rats. • AS strongly induced α6 and β1 integrins and activated Erk1/2. • Integrin Induction was primarily specific to acupuncture site and needle rotation.

60 APPLIED LIFE SCIENCES↗

Performance of automatic scanning microscope for nuclear emulsion experiments

The impressive improvements in scanning technology and methods let nuclear emulsion to be used as a target in recent large experiments. We report the performance of an automatic scanning microscope for nuclear emulsion experiments. After successful calibration and alignment of the system, we have reached 99% tracking efficiency for the minimum ionizing tracks that penetrating through the emulsions films. The automatic scanning system is successfully used for the scanning of emulsion films in the OPERA experiment and plan to use for the next generation of nuclear emulsion experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma surface ionization wave interactions with single channels

Abstract The study of plasma surface ionization waves (SIWs) in recent years has primarily focused on planar surfaces and periodic two dimensional structures. In application, substrates are likely to have non-planar morphology such as cracks, pores, and steps. Additionally, targets for the applications of medicine or catalysis may have targets with heterogeneous composition. This classification of targets are brought under the umbrella of complex interfaces. In this work, plasma SIWs were incident on a complex target consisting of a single channel cut into glass slides. The SIW velocities for the in-channel portion of the wave and radially propagating portion of the wave were tracked. It was found that surface wave velocities are not significantly affected by channel geometry, but primarily increase with pulse energy. A third propagation direction for the SIW is characterized in the azimuthal direction relative to the radial portion of the wave. Channel geometry is found to greatly effect the area treated by the plasma but not the propagation velocity of the surface wave. Surface wave morphology and the impact on application is also discussed. A simple model was introduced to understand the mechanisms behind SIW escape from a channel. It was found that the ratio of pulse energy to a geometry dependent minimum energy can predict the escape angle of a SIW from single channels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field quality of the 4.5 m-long MQXFA pre-series magnets for the HL-LHC Upgrade as observed during magnet assembly

We report that the U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) is developing MQXFA magnets, a series of 4.5 m long 150 mm aperture high-field Nb 3 Sn quadrupole magnets for the HL-LHC upgrade at CERN. Five pre-series magnets, MQXFA03 through MQXFA07, have been developed. During the magnet assembly stage, we perform magnetic measurements on the coil-pack sub-assembly and magnets after loading to track the field quality for two purposes. First, it serves as a quality assurance tool to check if the magnetic field quality is on track to meet the acceptance criteria. Magnetic measurements are used to understand if magnetic shims are needed to compensate low-order field errors and to meet the field quality targets. Second, the measurements during the assembly stage can also help understand the field quality, especially the geometric field errors, for Nb 3 Sn accelerator magnets. Here we summarize the measurement results of the pre-series MQXFA magnets, including the magnetic axis and twist angle. The results will provide useful feedback for the series production of Nb 3 Sn magnets and on the optimization of field quality of accelerator magnets based on the wind-and-react Nb 3 Sn technology.

43 PARTICLE ACCELERATORS↗

Multisensor Agile Adaptive Sampling (MAAS): A Methodology to Collect Radar Observations of Convective Cell Life Cycle

Abstract Multisensor Agile Adaptive Sampling (MAAS), a smart sensing framework, was adapted to increase the likelihood of observing the vertical structure (with little to no gaps), spatial variability (at subkilometer scale), and temporal evolution (at ∼2-min resolution) of convective cells. This adaptation of MAAS guided two mechanically scanning C-band radars (CSAPR2 and CHIVO) by automatically analyzing the latest NEXRAD data to identify, characterize, track, and nowcast the location of all convective cells forming in the Houston domain. MAAS used either a list of predetermined rules or real-time user input to select a convective cell to be tracked and sampled by the C-band radars. The CSAPR2 tracking radar was first tasked to collect three sector plan position indicator (PPI) scans toward the selected cell. Edge computer processing of the PPI scans was used to identify additional targets within the selected cell. In less than 2 min, both the CSAPR2 and CHIVO radars were able to collect bundles of three to six range–height indicator (RHI) scans toward different targets of interest within the selected cell. Bundles were successively collected along the path of cell advection for as long as the cell met a predetermined set of criteria. Between 1 June and 30 September 2022 over 315 000 vertical cross-section observations were collected by the C-band radars through ∼1300 unique isolated convective cells, most of which were observed for over 15 min of their life cycle. To the best of our knowledge, this dataset, collected primarily through automatic means, constitutes the largest dataset of its kind.

54 ENVIRONMENTAL SCIENCES↗

Results from the Particle Tracking System of the Qweak Experiment

The goal of the Qweak experiment is to measure the value of the weak charge of the proton, Qpweak=1-4sin2θw, to 4\% precision. Because the Standard Model makes a firm prediction of Qpweak, the measurement of Qpweak will either confirm the prediction or will provide clear evidence for new physics. In this experiment, we study elastic electron proton scattering at four momentum transfer Q2=0.03GeV2/c2 by scattering a high current polarized electron beam on a liquid hydrogen target. A crucial element to the precise measurement of Qpweak is to determine the four momentum transfer Q2 to a high precision because the parity violation asymmetry is directly proportional to Q2: ApLR=A0[QpweakQ2+B4(Q2)Q4+...]. Therefore, the experiment is also designed to run in a low current mode in which the Q2 is determined by using the tracking detectors. The tracking system is aimed at reconstructing the track of a particle to get the Q2 with an accuracy of 1\%. The experiment is now in the phase I data production run, which will end in May 2011. I will describe the procedure of the track reconstruction and the first results coming from it.

Yang, Siyuan↗