Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors↗

Overhead longwave infrared hyperspectral material identification using radiometric models

Material detection algorithms used in hyperspectral data processing are computationally efficient but can produce relatively high numbers of false positives. Material identification performed as a secondary processing step on detected pixels can help mitigate false positives. A material identification processing chain for longwave infrared hyperspectral data of solid materials collected from airborne platforms is presented. The algorithms utilize unwhitened radiance data and Nelder–Meade numerical optimization to estimate the temperature, humidity, and ozone levels of the atmospheric profile. Pixel unmixing is done using constrained linear regression and Bayesian information criteria for model selection. The resulting identification product includes an optimal atmospheric profile and a full radiance material model that includes material temperature, abundance values, and several fit statistics. A logistic regression method utilizing the model parameters to improve identification is also presented. Furthermore, several examples are provided using modeled data at several noise levels.

58 GEOSCIENCES↗

Time-stretch spectroscopy for fast infrared absorption spectra of acetylene and hydroxyl radicals during combustion

We have developed a diagnostic that uses time-domain spectroscopy to measure transient infrared absorption spectra in gases. Using a time-stretch Fourier transform approach, we can determine pressure, temperature, and gas concentrations with sub-microsecond time resolution for over two milliseconds. We demonstrate high-resolution (0.015 nm), time-resolved spectral measurements in an acetylene-oxygen gas mixture undergoing combustion. Within a 5 µs period during the reaction, the acetylene line intensities decrease substantially, and new spectra appear that are consistent with the hydroxyl (OH) radical, a common by-product in the combustion, deflagration, and detonation of fuels and explosives. Post-reaction pressures and temperatures were estimated from the OH spectra. The technique measures spectra from 1520 to 1620 nm using fiber optics, photodetectors, and digitizers. No cameras or spectrometers are required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Streamflow measurements from four sites on the Tuolumne River in Yosemite National Park from Water Years 2002 to 2021

Regions with remote and complex terrain experience spatially varying streamflow patterns, but are often poorly sampled due to difficult access. This data package includes streamflow measurements collected using low-visibility and low-impact installations at four sites on the Tuolumne River in Yosemite National Park, for water years 2002 to 2021. The resulting data set offers a unique opportunity to explore hydrologic processes in complex terrain.This data package contains half-hourly recordings of unvented pressure, vented pressure, and water temperature are measured and used to estimate discharge and stage height. Discharge flags provide insight into data anomalies. This dataset is formatted in accordance with ESS-Dive's Hydrologic Monitoring and File Level Metadata Formats. It contains the following files:1) Folder containing four csv files of time series streamflow measurements (unvented pressure, vented pressure, estimated discharge, water temperature, stage height, and discharge flag) from four locations on the Tuolumne River2) Data dictionary (dd.csv) containing units, definitions, human readable column names, and data type for all column headers throughout the dataset3) File-level metadata (FLMD.csv) containing metadata for files contained in the dataset4) Installation methods (InstallationMethods.csv) containing metadata on sensor installation

54 ENVIRONMENTAL SCIENCES↗

Long-Term Infrasound Sensor Calibration and Characterization

Previous testing has shown that infrasound sensors deployed in the field can exhibit notable deviations from their nominal, lab-based calibrations. These variations may be due to changes in environmental conditions, long-term sensor drift, or other unresolved features. In early 2018, we installed two identical infrasound elements with five infrasound sensors at each element (Chaparral M50A, Chaparral M64LN, CEA/Martec MB2005, CEA/Seismowave MB3a, and Hyperion IFS-5113A). These sensors were accepted or under consideration for use in the International Monitoring System network of the Comprehensive Nuclear-Test-Ban Treaty. Each element had all sensors connected to a single digitizer and port to the atmosphere. We also recorded instrument enclosure air temperature and humidity and external air temperature. Using the MB2005 as the reference, we examine the relative sensor response (both magnitude and phase) as a function of time and frequency and compare it with quarterly laboratory calibrations and environmental conditions. Here, we find that the magnitude response for all sensors exhibits some variability in both the lab and field, with the amplitude variations often >5%. The field-based variations are more severe and occur on both long-term (months) and short-term (hours) timescales. Short-term variability correlates with changes in environmental conditions and is considerable (up to 25%) for the Chaparral M50A and noticeable (∼5%) for the French Alternative Energies and Atomic Energy Commission (CEA) MB3a. Long-term magnitude variability for the Chaparral M50A was up to 50% and does not clearly correlate with environmental conditions. The other sensors show some long-term magnitude offsets, but they have relatively stable responses in the conditions we examined. The MB3a also displays some frequency-dependent magnitude variability and shows a minor dependence on temperature. Phase estimates are stable and near zero for all sensors tested. These results strongly suggest sensor response and variability due to environmental conditions should be considered in future infrasound data interpretation and sensor selection and development.

Fee, David↗

Carbon Dioxide Flux Measurement System (CO2FLX) Instrument Handbook

The Southern Great Plains (SGP) carbon dioxide flux (CO2 flux) measurement systems provide half-hour average fluxes of CO2, H2O (latent heat), and sensible heat. The fluxes are obtained by the eddy covariance technique, which computes the flux as the mean product of the vertical wind component with CO2 and H2O densities, or estimated virtual temperature. A three-dimensional sonic anemometer is used to obtain the orthogonal wind components and the virtual (sonic) temperature. An infrared gas analyzer is used to obtain the CO2 and H2O densities. A separate sub-system also collects half-hour average measures of meteorological and soil variables from separate 4-m towers.

54 ENVIRONMENTAL SCIENCES↗

Final Report: Levitated Dipole Experiment

Since the very first experiments with the LDX, research progress was rapid and significant. Initial experiments were conducted with the high-field superconducting coil suspended by three thin rods. These experiments produced long-pulse, quasi-steady-state microwave discharges, lasting more than 10 s, having peak beta values of 20%. High-beta, near steady-state discharges have been maintained in LDX for more than 20 seconds, and this capability makes LDX the longest pulse fusion confinement experiment now operating in the U.S. fusion program. In both supported and levitated configurations, detailed measurements are made of discharge evolution, plasma dynamics and instability, and the roles of gas fueling, microwave power deposition profiles, and plasma boundary shape. High-temperature plasma is created by multifrequency electron cyclotron resonance heating allowing control of heating profiles. Depending upon neutral fueling rates, the LDX discharges contain a fraction of energetic electrons, with mean energies above 50 keV. Depending on whether or not the superconducting dipole is levitated or supported, the peak thermal electron temperature is estimated to exceed 500 eV and peak densities reach 10 18 m -3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Report: Levitated Dipole Experiment

Since the very first experiments with the LDX, research progress was rapid and significant. Initial experiments were conducted with the high-field superconducting coil suspended by three thin rods. These experiments produced long-pulse, quasi-steady-state microwave discharges, lasting more than 10 s, having peak beta values of 20% [Garnier et al., Physics of Plasmas, 13 (2006) 056111]. High- beta, near steady-state discharges have been maintained in LDX for more than 20 seconds, and this capability made LDX the longest pulse fusion confinement experiment operating in the U.S. fusion program. A significant measure of progress in the LDX research program was the routine investigation of plasma confinement with a magnetically-levitated dipole and the resulting observations of confinement improvement. In both supported and levitated configurations, detailed measurements were made of discharge evolution, plasma dynamics and instability, and the roles of gas fueling, microwave power deposition profiles, and plasma boundary shape. High-temperature plasma was created by multi frequency electron cyclotron resonance heating at 2.45 GHz, 6.4 GHz, 10.5 GHz and 28 GHz allowing control of heating profiles. Depending upon neutral fueling rates, the LDX discharges contain a fraction of energetic electrons, with mean energies above 50 keV. Depending on whether or not the superconducting dipole was levitated or supported, the peak thermal electron temperature was estimated to exceed 500 eV and peak densities to approach 1e18 m -3 . We have found that levitation causes a strong inwards density pinch [Boxer et al., Nature Physics, 6 (2010) 207] and we have observed the central plasma density increase dramatically indicating a significant improvement in the confinement of a thermal plasma species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthesis of a potential fast ionic conductor for Mg 2+ ions

This report represents Powdermet’s attempts to synthesize a novel crystalline solid substance–Mg(B 5 C) 2 . This was expected to exhibit a high Mg 2+ ionic conductivity, exceeding that of all known materials. The project was expected to consist of three major steps: 1) reproduction of a literature synthesis of a rare sodium compound NaB 5 C; 2) substitution of Na+ cations with Mg 2+ cations, resulting in Mg(B 5 C) 2 ; and 3) analysis of its Mg 2+ conductivity. In course of the research, 15 attempts were made to reproduce the literature procedure on synthesis of NaB 5 C, a precursor to the Mg 2+ conductor. The first nine attempts were unsuccessful, but later it was found that NaB 5 C formed when the synthesis was performed in pressurized Ar atmosphere. Powdermet performed partial exchange of Na + to Mg 2+ by heating NaB 5 C with magnesium triflate in sulfolane at 260°C. In another avenue, theoretical optimization of the Mg(B 5 C) 2 structure have been performed with distant goal estimate the activation barrier for the Mg 2+ diffusion and estimate the temperature at which the mobility of Mg 2+ cations will be of the order of 10 -2 S*cm.

36 MATERIALS SCIENCE↗

Thermal-Hydraulic Simulations of Single Pin and Assembly Sector for IVG- 1M Reactor

Thermal-hydraulic simulations have been performed using computational fluid dynamics (CFD) for the highly-enriched uranium (HEU) design of the IVG.1M reactor at the Institute of Atomic Energy (IAE) at the National Nuclear Center (NNC) in the Republic of Kazakhstan. Steady-state simulations were performed for both types of fuel assembly (FA), i.e. the FA in rows 1 & 2 and the FA in row 3, as well as for single pins in those FA (600 mm and 800 mm pins). Both single pin calculations and bundle sectors have been simulated for the most conservative operating conditions corresponding to the 10 MW output power, which corresponds to a pin unit cell Reynolds number of only about 7500. Simulations were performed using the commercial code STAR-CCM+ for the actual twisted pin geometry as well as a straight-pin approximation. Various Reynolds-Averaged Navier-Stokes (RANS) turbulence models gave different results, and so some validation runs with a higher-fidelity Large Eddy Simulation (LES) code were performed given the lack of experimental data. These singled out the Realizable Two-Layer k-ε as the most accurate turbulence model for estimating surface temperature. Single-pin results for the twisted case, based on the average flow rate per pin and peak pin power, were conservative for peak clad surface temperature compared to the bundle results. Also the straight-pin calculations were conservative as compared to the twisted pin simulations, as expected, but the single-pin straight case was not always conservative with regard to the straight-pin bundle. This was due to the straight-pin temperature distribution being strongly influenced by the pin orientation, particularly near the outer boundary. The straight-pin case also predicted the peak temperature to be in a different location than the twisted-pin case. This is a limitation of the straight-pin approach. The peak temperature pin was in a different location from the peak power pin in every case simulated, and occurred at an inner pin just before the enrichment change. The 600 mm case demonstrated a peak clad surface temperature of 370.4 K, while the 800 mm case had a temperature of 391.6 K. These temperatures are well below the necessary temperatures for boiling to occur at the rated pressure. Fuel temperatures are also well below the melting point. Future bundle work will include simulations of the proposed low-enriched uranium (LEU) design. Two transient scenarios were also investigated for the single-pin geometries. Both were “model” problems that were focused on pure thermal-hydraulic behavior, and as such were simple power changes that did not incorporate neutron kinetics modeling. The first scenario was a high-power, ramp increase, while the second scenario was a low-power, step increase. A cylindrical RELAP model was also constructed to investigate its accuracy as compared to the higher-fidelity CFD. Comparisons between the two codes showed good agreement for peak temperatures in the fuel and at the cladding surface for both cases. In the step transient, temperatures at four axial levels were also computed. These showed greater but reasonable discrepancy, with RELAP outputting higher temperatures. These results provide some evidence that RELAP can be used with confidence in modeling transients for IVG.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Methodologies for Reservoir Characterization Using Fluid Inclusion Gas Chemistry

The purpose of this project was to: 1) evaluate the relationship between geothermal fluid processes and the compositions of the fluid inclusion gases trapped in the reservoir rocks; and 2) develop methodologies for interpreting fluid inclusion gas data in terms of the chemical, thermal and hydrological properties of geothermal reservoirs. Phase 1 of this project was designed to conduct the following: 1) model the effects of boiling, condensation, conductive cooling and mixing on selected gaseous species; using fluid compositions obtained from geothermal wells, 2) evaluate, using quantitative analyses provided by New Mexico Tech (NMT), how these processes are recorded by fluid inclusions trapped in individual crystals; and 3) determine if the results obtained on individual crystals can be applied to the bulk fluid inclusion analyses determined by Fluid Inclusion Technology (FIT). Our initial studies however, suggested that numerical modeling of the data would be premature. We observed that the gas compositions, determined on bulk and individual samples were not the same as those discharged by the geothermal wells. Gases discharged from geothermal wells are CO 2 -rich and contain low concentrations of light gases (i.e. H 2 , He, N, Ar, CH4). In contrast many of our samples displayed enrichments in these light gases. Efforts were initiated to evaluate the reasons for the observed gas distributions. As a first step, we examined the potential importance of different reservoir processes using a variety of commonly employed gas ratios (e.g. Giggenbach plots). The second technical target was the development of interpretational methodologies. We have develop methodologies for the interpretation of fluid inclusion gas data, based on the results of Phase 1, geologic interpretation of fluid inclusion data, and integration of the data. These methodologies can be used in conjunction with the relevant geological and hydrological information on the system to create fluid models for the system. The hope is that the methodologies developed will allow bulk fluid inclusion gas analysis to be a useful tool for estimating relative temperatures, identifying the sources and origins of the geothermal fluids, and developing conceptual models that can be used to help target areas of enhanced permeability.

15 GEOTHERMAL ENERGY↗

Methodology for Irradiation Creep Testing of SiC / SiC Composite Cladding

Irradiation creep compliance is a critical parameter for evaluating the stress evolution of silicon carbide (SiC) components during operation in various reactor concepts. Recent instrumented irradiation creep testing of SiC, performed at low dose in the Halden reactor, showed a creep compliance that is orders of magnitude higher than previous un-instrumented bend relaxation experiments performed in the High Flux Isotope Reactor (HFIR). This discrepancy illustrates the need for additional irradiation creep data for SiC. To this end, a novel irradiation capsule design has been developed to test miniature SiC tensile specimens under loading during irradiation in the HFIR. The experiment design uses the coolant pressure of the HFIR to compress a bellows, which applies the loading on the specimen. Preliminary thermal finite element models were developed to estimate the temperature distribution within the specimen and surrounding capsule components. Similar structural models were developed to evaluate the stress distribution within the specimen. The thermal analyses show that within the gauge section, the specimen temperatures remain within ~10°C of the nominal 300°C design temperature. Similarly, the structural analysis predicts axial stresses within ~10 MPa of the target stress of 100 MPa. These initial analyses show that irradiation creep testing of SiC in the HFIR is feasible and could provide a low-cost, high-throughput vehicle for gathering needed irradiation creep data.

36 MATERIALS SCIENCE↗

Assembly Operations Welding Filter(s) in Drum Calculation

This calculation documents the estimation of temperature and pressure rise inside a 55-gal TRU waste drum with a HEPA filter containing Titanium and Tantalum fume dust based on operational history.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assembly Operations Welding Filter(s) in Drum Calculation

This calculation documents the estimation of temperature and pressure rise inside a 55-gal TRU waste drum with a HEPA filter containing Titanium and Tantalum fume dust based on operational history. Actual Titanium values are believed to be less than 10g on any given filter. Actual Tantalum values are believed to be less than 1g on any given filter

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oakridge Geothermal Resources Assessment

Through the Communities Local Energy Action Program (LEAP), NREL provided technical assistance to a coalition of stakeholders from Oakridge, Oregon. The coalition included community-based non-profit organizations, the city government, the local utility, and others. Technical assistance provides analysis and information to support Oakridge stakeholders with their goals to increase energy reliability and resilience in the community, while promoting economic development. The Geothermal Resource Assessment provides technical analysis related to the geothermal resource in the Oakridge area, possible technology applications, and information related to further geothermal exploration. Technical analysis includes a review of a previous geothermal study conducted for Oakridge, thermal modeling to estimate reservoir temperatures, and technoeconomic simulation of a combined heat and power application in the Oakridge area.

15 GEOTHERMAL ENERGY↗

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]↗

CERESMIP: a climate modeling protocol to investigate recent trends in the Earth's Energy Imbalance

The Clouds and the Earth's Radiant Energy System (CERES) project has now produced over two decades of observed data on the Earth's Energy Imbalance (EEI) and has revealed substantive trends in both the reflected shortwave and outgoing longwave top-of-atmosphere radiation components. Available climate model simulations suggest that these trends are incompatible with purely internal variability, but that the full magnitude and breakdown of the trends are outside of the model ranges. Unfortunately, the Coupled Model Intercomparison Project (Phase 6) (CMIP6) protocol only uses observed forcings to 2014 (and Shared Socioeconomic Pathways (SSP) projections thereafter), and furthermore, many of the ‘observed' drivers have been updated substantially since the CMIP6 inputs were defined. Most notably, the sea surface temperature (SST) estimates have been revised and now show up to 50% greater trends since 1979, particularly in the southern hemisphere. Additionally, estimates of short-lived aerosol and gas-phase emissions have been substantially updated. These revisions will likely have material impacts on the model-simulated EEI. We therefore propose a new, relatively low-cost, model intercomparison, CERESMIP, that would target the CERES period (2000-present), with updated forcings to at least the end of 2021. The focus will be on atmosphere-only simulations, using updated SST, forcings and emissions from 1990 to 2021. The key metrics of interest will be the EEI and atmospheric feedbacks, and so the analysis will benefit from output from satellite cloud observation simulators. The Tier 1 request would consist only of an ensemble of AMIP-style simulations, while the Tier 2 request would encompass uncertainties in the applied forcing, atmospheric composition, single and all-but-one forcing responses. We present some preliminary results and invite participation from a wide group of models.

54 ENVIRONMENTAL SCIENCES↗