Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

DROP DURABILITY ASSESSMENT OF ELECTRONIC ASSEMBLIES UNDER OFF-AXIS LOADING WITH SKEWED FIXTURES

This thesis studies drop durability of electronic assemblies when the acceleration vector is oriented at 45° to the out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field environments during ground-based laboratory testing. However, many of these test methods require expensive and specialized equipment not available in most laboratories. An alternative approach for approximating simultaneous loading along multiple axes on conventional equipment utilizes skewed fixtures which have seen use in off-axis random vibration and drop impact testing. These methods generally rely on the conversion of a uniaxial input load from the test equipment (using a uniaxial drop tower or shaker) into a multiaxial load when resolved in the reference frame of the test article (mounted on a skewed fixture). Skewed fixture design is presented and recommendations for conducting skewed angle drop testing are introduced based on local measurements along the skewed face of the fixture to accurately monitor the impact event. Characterization tests were performed with a skewed fixture, at simultaneous acceleration loads from 500 to 3,000 g in two (in-plane and out-of-plane) directions, while meeting standard time domain tolerances. Upon experimental characterization, drop shock durability tests were conducted on a printed circuit assembly (PCA). Mean drops-to-failure were measured and quantified with Weibull statistics. Dominant solder joint failure modes were identified via failure analysis. Prior work on inclined angle impact testing is limited, and the majority of solder joint interconnect level fatigue studies are conducted considering perpendicular loading normal the circuit card. Low-cycle fatigue curves are generated based on plastic strain and plastic work density within the solder joint. A multiscale nonlinear finite element model is used to relate board-level flexure to solder joint interconnect level plastic strain. A high strain rate solder constitutive model allows for accurate modeling of solder plasticity resulting from high-impact drop shock. Fatigue parameters are computed from the Coffin-Manson relation and Palmgren-Miner damage accumulation. This work serves to apply established low-cycle fatigue methods for conventional drop shock loading (impact normal to circuit card) to non-perpendicular loading with a skewed fixture.

Hower, Jonathan [Kansas City National Security Cam↗

Small Punch Testing of Molybdenum-99 Targets

Northstar Medical Radioisotopes is developing an accelerator-based method to produce 99 Mo, which is a parent isotope of the commonly used 99m Tc medical isotope. The Mo targets being designed for the accelerator will be produced from enriched 100 Mo, also known as aMo . Pressed and sintered powder feedstock is used to fabricate aMo targets, producing 29 mm disk-shaped targets. The targets are subjected to 1–6 days in line of an electron beam with subsequent dissolution of the disk to retain the 99 Mo, which decays to 99m Tc at radio-pharmacies. The press and sinter method is advantageous because the inherent porosity produced by this method enables increased surface area and therefore increased flow of dissolution media, decreasing the dissolution time and reducing the need for a highly acidic media. Although porosity aids in dissolution, it reduces the mechanical strength and ductility. Targets require good mechanical integrity when subjected to the conditions in the accelerator. Therefore, Northstar is seeking methods to rapidly test disk samples after fabrication to assure mechanical performance metrics are achieved. This report details the design and testing of a small punch test (SPT) that accommodates the 29 mm disk. Initial data were used to relate the SPT data to tensile properties, such as the yield strength (YS), ultimate tensile strength (UTS), and total elongation to failure. Although the SPT has been established as a somewhat reliable method for testing metallic materials, few studies have applied the SPT to refractory materials such as Mo. Based on tensile testing performed at Oak Ridge National Laboratory on different Mo samples, correlation between the Mo tensile and SPT properties could be performed, establishing a standard calibration that could be applied to other Mo samples. To test the efficacy of the SPT with Mo, multiple different disk batches were fabricated under different conditions (e.g., pressure, lubricant) with commercially available pure Mo powder. Generally, only a UTS could be well defined because the press and sinter disks failed under brittle fracture, making it difficult to determine the YS and elongation. Compared with disks fabricated with aMo powder, the aMo samples underperformed their pure nat Mo counterparts. This report summarizes the current status of the SPT, but further evaluation is needed before it can be applied as a reliable quality assurance tool.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of an In-Situ Leaching Technology for Extracting Residual Uranium from Remediated Soil - 20099

Site-specific chemical solutions for extracting uranium were developed and evaluated for treating previously remediated soil at a former thorium mill tailings site, known as the Former Rare Earths Facility (REF), in West Chicago, Illinois. Prior remediation efforts had resulted in residual sand and gravel aggregate that met the soil cleanup standards. The target soil contains residual levels of uranium, which continues to leach into the site groundwater at levels exceeding groundwater protection standards (GWPS). A series of bench-scale tests were conducted to evaluate the efficacy and viability of in-situ leaching (ISL) technology to treat the target soil for the purposes of attaining uranium GWPS at the REF. Specific objectives of the bench-scale tests entailed identification and selection of optimal leaching, quantification of the extent and rate of uranium released as a function of chemical composition, chemical concentrations, chemical residence times, and obtaining critical data to estimate treatment costs. A combination of sodium bicarbonate and sodium carbonate reagent was the most effective leaching solution. In general, leaching solutions containing a higher concentration of sodium carbonate demonstrated superior uranium leaching capabilities. Removal of 50% of the uranium mass from the soil matrix was adequate for achieving compliance with the site-specific GWPS. After six to seven pore volume flushes (PVFs), the uranium leaching effectiveness of all leaching solutions was similar. The amount of initial uranium removed with each subsequent PVF was minimal, suggesting limited solubility of the remaining mass of uranium. The effects of leaching duration were significant and persisted through at least the first five consecutive PVFs. Leaching of uranium also resulted in leaching of several non-uranium constituents, many of which exceeded applicable National Pollutant Discharge Elimination System (NPDES) standards. Given historical operations and waste disposal practices at the site, leaching of non-uranium constituents was expected. Hydrochloric acid was used to stabilize treated soil. Savings of approximately $148 million in direct and indirect remediation costs are expected with an ISL alternative compared to the excavation and landfill disposal remediation option. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation, Challenge Testing & Validation of Occupancy Recognition & CO 2 Technologies (Final Project Report)

This final report covers the results of the development of testing methods of occupancy sensor systems connected to HVAC controls. This project focused on the development of test methods to evaluate the performance of HVAC-connected occupancy sensor systems, including occupancy presence, occupancy counting, and CO 2 sensor systems in commercial and residential buildings. This included evaluation of the reliability, ease of commissioning, and energy savings potential of these sensor systems. The results of this work help to standardize the methods used to evaluate performance, to enable the ability to compare sensor system performance following the same methods, to understand which sensor systems perform better or worse compared to others. The U.S. building stock’s energy usage can benefit substantially from having building system operations informed by reliable occupancy recognition and CO 2 measurements, however to date, standard methods have not been in place to ensure that sensor systems’ reported performance is uniformly evaluated. The results of this work support the development of a standard or guideline that outlines the developed methods of testing. This project also included the testing of both off-the-shelf and novel SENSOR team-developed low-cost occupancy sensor systems, using the developed methods of testing. The results of this testing helped to inform further development and improvement of new low-cost sensor systems that will benefit from being used in residential and commercial buildings throughout the country.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Anomalies in global SMEFT analyses. A case study of first-row CKM unitarity

Recent developments in the Standard Model analysis of semileptonic charged-current processes involving light quarks have revealed ~ 3σ tensions in Cabibbo universality tests involving meson, neutron, and nuclear beta decays. In this paper, we explore beyond the Standard Model explanations of this so-called Cabibbo Angle Anomaly in the framework of the Standard Model Effective Field Theory (SMEFT), including not only low-energy charged current processes (‘L’), but also electroweak precision observables (‘EW’) and Drell-Yan collider processes (‘C’) that probe the same underlying physics across a broad range of energy scales. The resulting ‘CLEW’ framework not only allows one to test explanations of the Cabibbo Angle Anomaly, but is set up to provide near model-independent analyses with minimal assumptions on the flavor structure of the SMEFT operators. Besides the global analysis, we consider a large number of simpler scenarios, each with a subset of SMEFT operators, and investigate how much they improve upon the Standard Model fit. We find that the most favored scenarios, as judged by the Akaike Information Criterion, are those that involve right-handed charged currents. Additional interactions, namely oblique operators, terms modifying the Fermi constant, and operators involving right-handed neutral currents, play a role if the CDF determination of the W mass is included in the analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Failure Strain and Related Triaxiality of Aluminum 6061-T6, A36 Carbon Steel, 304 Stainless Steel, and Nitronic 60 Metals, Part I: Experimental Investigation

The objective of this study is to develop failure-limit material models for Aluminum 6061-T6, A36 Carbon Steel, 304 Stainless Steel, and Nitronic 60 metals, based on parameters of plastic equivalent strain (failure strain) and stress triaxiality. The research is conducted in two parts. This paper presents Part One of the study. In Part One, custom-designed test specimens undergo controlled uniaxial tension and compression testing at ambient temperature. These tests are performed at quasi-static speeds using Universal Testing Machines (UTMs) in accordance with ASTM E8 and ASTM E9 standards. Experimental data, specifically engineering stress–strain and force–displacement curves, are recorded from the onset of loading until specimen fracture, or in the case of compression tests, until the capacity of the testing machine is reached. In Part Two, the emphasis shifts to the calibration of Finite Element Analysis (FEA) models of the custom-designed test specimens. Plastic equivalent strain and the corresponding stress triaxiality values at failure are extracted from each test specimen for the given metal. These values are then systematically plotted onto a single graph to construct the failure-limit curve, which delineates the boundary conditions for material failure. This approach will facilitate the development of a comprehensive material property definition that correlates plastic equivalent strain with stress triaxiality at failure for Aluminum 6061-T6, A36 Carbon Steel, 304 Stainless Steel, and Nitronic 60 metals.

Harwell, Ron↗

A Custom High-Throughput Optical Mapping Instrument for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom optical mapping instrument (OMI) to improve measurement throughput time, facilitate automated measurements, allow for localized specimen examination, obtain spatial information relative to commercial benchtop spectrophotometer instruments, and provide automated data analysis. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. In addition to the unique instrument developed in this study, new insights have emerged from the examination of specimens from previous experiments, including: the depletion of the UV absorber is revealed for specimens beyond a certain size after artificial ultraviolet (UV) weathering; an optical degradation by internal haze formation is confirmed following Damp Heat (85 °C/85% relative humidity) testing; the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture; and the greater local (in the order of millimeters) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

14 SOLAR ENERGY↗

Enhancing Post-Irradiation Examination (PIE) Efficiency with High-Throughput Experiments

Nuclear materials testing is essential for understanding changes in reactor environments, but traditional methods are costly and time-consuming. High-Throughput Experimentation (HTE) enables rapid screening and optimization of material properties by significantly increasing the number of specimens in the experiment. In this work, HTE methods were employed to irradiate novel materials at the Advanced Test Reactor (ATR) at Idaho National Laboratory. A total of 367 sub-sized tensile specimens were irradiated using the standard capsule design. To facilitate HTE, automated systems such as the Automated Mechanical Testing System were implemented for mechanical testing within hot cell environments, thereby reducing the need for manual interaction with hot cell manipulators and significantly lowering both the cost and duration of experiments. Digital image correlation (DIC) was used to measure displacement during mechanical testing, providing precise, non-contact measurement capabilities. The methodologies developed in this research will support the advancement of HTE techniques for future nuclear materials testing experiments at ATR. This approach allows for more efficient and cost-effective evaluation of new materials, ultimately leading to improved reactor performance, enhanced safety, and extended longevity within the nuclear industry.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Determining the tensile strength of fuel surrogate TRISO-coated particle buffer, IPyC, and buffer-IPyC interlayer regions

A novel micro tensile sample fabrication technique for determining the tensile strength of the buffer, IPyC, and buffer -IPyC interlayer regions of surrogate (ZrO2) TRISO fuel particle layers was refined and implemented. Copper micro tensile samples served as baseline materials to verify the methods used. Tensile tests performed in this study, while limited in number, were analyzed using standard and Weibull statistics. As expected, the buffer layer was weakest, with an average ultimate tensile strength of 138.70 MPa, and the IPyC layer samples, were strongest, with an average ultimate tensile strength of 189.74 MPa. In the buffer -IPyC interface samples, all breaks occurred in the buffer region, though the average ultimate tensile strength of the samples, 159.80 MPa, was between the pure buffer and IPyC samples. These results suggest the interlayer region has unique properties, perhaps associated with pyrocarbon infiltration into the buffer layer during particle coating. All interlayer samples fractured within the buffer side; however, the stress strain behavior of some of these samples resembled the behavior of the IPyC layer samples. Here, the buffer and IPyC layer strengths had a normal distribution under Weibull analysis, while the interlayer region had a Rayleigh distribution. Further testing is needed to clarify both the standard and Weibull statistical results

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Additively Manufactured Complex Tools for Autoclave Cure Composites

IACMI Project 4.9, Tooling for Composites with Washout Features Produced by Additive Manufacturing, assembled a team including the industry lead, Ability Composites, NREL and Colorado State University (CSU). Ability Composites had originally expressed interest in alternate methods of producing tooling for composite parts. In follow-up discussions, it became clear that one of the bigger tooling challenges revolved around small production volume composite parts that were tooled on washout material due to the complex geometry. To build an understanding of the potential, both from a technology and a cost perspective, for replacing conventional washout tooling with 3D printed thermoplastic tooling, a number of commercially available dissolvable FDM printing materials were evaluated, leading to tooling representative of commercial articles of interest to Ability Composites. Ultimately, Ability Composites was able to directly compare autoclave processed prepreg composite parts produced on conventional washout tooling to composite parts molded on 3D printed dissolvable tooling produced at CSU. Small, laboratory test specimens were developed to investigate the structural performance of the candidate materials under autoclave processing conditions, which were nominally 121 °C (250 °F) and 345 kPa (50 psi). In addition, several internal structural configurations (infills) were evaluated under autoclave conditions using model materials. The results of these tests indicated that two materials, Stratasys ST 130 and Infinite Materials Solutions Aquasys 180 (AQ 180), were the best candidates, given the specified autoclave processing conditions. ST-130 was slightly more robust than AQ-180; however, the AQ-180 was carried forward as it was dissolvable in water, not requiring the basic solution needed to dissolve ST-130. Based on the preliminary material and 3D printed structures evaluations, larger tools with a truncated square pyramid geometry were created to produce prepreg composite test articles for 3D printed dissolvable tool evaluation under standard autoclave fabrication conditions. Two tools were manufactured using ST-130 and one tool using traditional ceramic washout tooling media. The tools were evaluated for geometric fidelity and surface roughness changes before and after carbon fiber/epoxy prepreg composites were manufactured on the tooling. The autoclave processing did not impact the geometry significantly and was completed at 121 °C and 345 kPa, indicating satisfactory tool performance. The results from surface roughness testing of both the resulting composite and the associated tooling indicated that an adequate surface resulted without the need for a surface sealing step, as was required for the conventional washout tooling. Based on results of the truncated pyramid tests as a basis, ST-130, AQ-120 and AQ-180 materials were carried forward to the tool geometry of interest to Ability Composites. These hollow rectangular bent ducts, which were complex in nature and not extractable after cure, were used to understand the impacts of tool material and thickness. One ST-130 tool was produced as a partially solid part, with an enclosed 40% dense infill region to reduce weight and material use. This was the same approach evaluated in the truncated pyramid portion of the study. This tool was to be envelope vacuum bagged and directly compared to a monolithic tool of conventional washout material. The traditional monolithic ceramic tool was manufactured by Ability composites using CNC-based subtractive methods. An additional five dissolvable polymer tools, manufactured from ST-130, AQ-120, and AQ-180, using a hollow design were 3D printed and used to produce carbon fiber/epoxy composite evaluation articles. These hollow dissolvable tools were expected to be less influenced by the autoclave conditions as the wall was solid and vacuum bagging was inside and outside the tool. This alternative geometry was also evaluated as an option in techno-economic modeling. Print times were reduced from in excess of 3 days to under 30 hours, while surface quality and and tool integrity were substantially improved in the transition from the partially solid tool to the hollow tooling concept. Ability Composites produced autoclave-cured prepreg ducts on each of these tools. The autoclave conditions utilized were more severe than those of the initial trials, reaching temperatures of 160 °C and a pressure of 414 kPa. Under these conditions, the partially solid 3D printed tool with skin and 40% dense infill crushed significantly; however, the thicker ST-130 hollow tool showed good promise, deforming only slightly. The thinner hollow tool walls were unsuccessful as were the other materials. Overall, the hollow tool manufacturing process saved significant amounts of time and material in manufacturing as compared to the solid ducts and produced composite surface quality improvements compared to the traditional washout tooling. The TEM was developed to allow direct comparisons between conventional washout tool manufacturing processes and those developed at CSU. It also allowed for two separate 3D printed tool geometries to be analyzed and compared. In this case, the square bent duct tool geometry was determined to be representative of common washout tools. This geometry was compared with a scaled-up version of it to assess differences in the two manufacturing processes based on tool size. The model was developed to make use of user input in the form of geometry details, process steps, manufacturing parameters, bulk material costs, capital equipment costs, and general costs to calculate overall labor, material, capital equipment, and energy costs per manufactured tool for the conventional and additive manufacturing processes for the two representative geometries. It was also able to estimate step-by-step process times for the manufacturing process and geometries. Based on significant input from Ability Composites and CSU from their knowledge gained from hands-on manufacturing of the 3D printed bent duct tool geometry, costs and process times were calculated for the two manufacturing processes. Results showed that the additive manufacturing techniques developed at CSU can substantially reduce the costs of tool manufacturing by reducing labor times and material usage. This is because additive manufacturing is a relatively hands-off process and allows for the tool design to be optimized to reduce material usage. The disadvantage, however, is that process times for additive manufacturing are significantly longer. The three-dimensional (3D) printing process is slow if tight tolerances are required, but the analysis did show that print times could be reduced with the hollow tool geometry. Also, further advances in additive manufacturing could expedite the process. Costs and process times for the tool washout process were calculated separately. They showed that costs are relatively insignificant when compared to the overall tool manufacturing processes, but with increases in tool size, costs for the conventional manufacturing approach are larger than for additive manufacturing. Again, the washout process for conventional tools is very hands-on, whereas for additively manufactured tools the print medium is dissolved in an automated detergent bath at the sacrifice of process time. The analysis showed that optimizing the additively manufactured tools may also reduce washout times. Overall, Project 4.9 demonstrated that commercially available dissolvable 3D printing materials exist that can be used to produce dissolvable tooling capable of surviving prepreg composites fabrication under autoclave conditions of 121 °C (250 °F) and 345 kPa (50 psi). An alternative hollow dissolvable tool design was developed which was structurally superior to the initial concept and was cost and time effective versus conventional washout tooling. The 3D printed sacrificial tool required no added surface sealing steps prior to composite part layup and cure, offering a significant advantage over the porous conventional washout tooling.

36 MATERIALS SCIENCE↗

Reference surface excess isotherms for carbon dioxide adsorption on ammonium ZSM-5 at various temperatures

Abstract This work is part of the effort at the Facility for Adsorbent Characterization and Testing (FACT lab) at the National Institute of Standards and Technology (NIST) to develop reference materials, reference data, and measurement best practices for adsorption metrology. High-pressure surface excess isotherms for CO 2 adsorption on NIST Reference Material 8852 (ammonium ZSM-5) at 15 °C, 25 °C, and 35 °C are reported, expanding on a FACT Lab-organized international interlaboratory study on this sorbent/sorbate pair at 20 °C. The range of temperatures of the present study is of interest for many CO 2 adsorption measurements and applications. Measurements were made using five different adsorption instruments, both manometric and gravimetric. Excellent agreement in the measured isotherms among the instruments was found. An empirical reference equation of the form, $${n}_{ex,ref}({P}_{eq})=\frac{c}{\{{1+\mathrm{exp}[\left(-\mathrm{ln}\left(P\right)+a\right)/b ]\}}^{b }} ,$$ n e x , r e f ( P eq ) = c { 1 + exp [ - ln P + a / b ] } b , [ n ex,ref is surface excess uptake (mmol/g); P eq is equilibrium pressure (MPa); P is ( P eq )/(1 MPa)]; a , b , c are constants] and the 95% uncertainty interval were determined for the isotherms at each of the temperatures. Lastly, the isosteric heat of adsorption is estimated from absolute isotherms derived from the surface excess reference data.

Nguyen, Huong Giang T. (ORCID:0000000210527565)↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

BigNeuron: a resource to benchmark and predict performance of algorithms for automated tracing of neurons in light microscopy datasets

BigNeuron is an open community bench-testing platform with the goal of setting open standards for accurate and fast automatic neuron tracing. We gathered a diverse set of image volumes across several species that is representative of the data obtained in many neuroscience laboratories interested in neuron tracing. Here, we report generated gold standard manual annotations for a subset of the available imaging datasets and quantified tracing quality for 35 automatic tracing algorithms. The goal of generating such a hand-curated diverse dataset is to advance the development of tracing algorithms and enable generalizable benchmarking. Together with image quality features, we pooled the data in an interactive web application that enables users and developers to perform principal component analysis, t-distributed stochastic neighbor embedding, correlation and clustering, visualization of imaging and tracing data, and benchmarking of automatic tracing algorithms in user-defined data subsets. The image quality metrics explain most of the variance in the data, followed by neuromorphological features related to neuron size. Furthermore, we observed that diverse algorithms can provide complementary information to obtain accurate results and developed a method to iteratively combine methods and generate consensus reconstructions. The consensus trees obtained provide estimates of the neuron structure ground truth that typically outperform single algorithms in noisy datasets. However, specific algorithms may outperform the consensus tree strategy in specific imaging conditions. Finally, to aid users in predicting the most accurate automatic tracing results without manual annotations for comparison, we used support vector machine regression to predict reconstruction quality given an image volume and a set of automatic tracings.

97 MATHEMATICS AND COMPUTING↗

The effect of ICRH and NBI on tungsten transport in neon edge radiation cooled discharges in TEXTOR

Tungsten is planned to be the plasma-facing material for the main chamber and divertor in future devices like ITER, SPARC, and DTT. To address risks associated with tungsten, R&D is being carried out on various toroidal confinement devices. One particular research question is related to the optimum heating mix for ITER. To investigate the influence of the heating scheme on the release and transport of tungsten, a comparison of neutral beam injection (NBI) and ion cyclotron resonance frequency (ICRF) heating was carried out in TEXTOR tungsten test limiter experiments. The experiments were performed under standard L-mode conditions and in radiative improved-mode operation with neon seeding and boronized walls covering the graphite plasma-facing components. The plasma was heated with hydrogen or deuterium NBI alone or with deuterium NBI in combination with H-minority, ion cyclotron resonance heating. A movable solid tungsten limiter was inserted through a limiter lock system into the edge plasma. The impurity release from this limiter was evaluated from visible spectroscopy. The tungsten concentrations in the plasma core were determined by extreme ultraviolet spectroscopy and bolometry. With deuterium NBI alone, strong central radiation and accumulation of W was observed. This can, however, be avoided by adding ICRF heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Versatile recognition of graphene layers from optical images under controlled illumination through green channel correlation method

In this study, a simple yet versatile method is proposed for identifying the number of exfoliated graphene layers transferred on an oxide substrate from optical images, utilizing a limited number of input images for training, paired with a more traditional number of a few thousand well-published Github images for testing and predicting. Two thresholding approaches, namely the standard deviation-based approach and the linear regression-based approach, were employed in this study. The method specifically leverages the red, green, and blue color channels of image pixels and creates a correlation between the green channel of the background and the green channel of the various layers of graphene. This method proves to be a feasible alternative to deep learning-based graphene recognition and traditional microscopic analysis. The proposed methodology performs well under conditions where the effect of surrounding light on the graphene-on-oxide sample is minimum and allows rapid identification of the various graphene layers. Here, the study additionally addresses the functionality of the proposed methodology with nonhomogeneous lighting conditions, showcasing successful prediction of graphene layers from images that are lower in quality compared to typically published in literature. In all, the proposed methodology opens up the possibility for the non-destructive identification of graphene layers from optical images by utilizing a new and versatile method that is quick, inexpensive, and works well with fewer images that are not necessarily of high quality.

36 MATERIALS SCIENCE↗

1.2 Mfps standalone X-ray detector for Time-Resolved Experiments

We present a standalone and autonomous X-ray detector capable of operation with the speed of up to1.2Mfps. The detector utilizes UFXC32k hybrid pixel detectors for sensing X-rays, Spartan-6 LX45 FPGA placed in commercially available sbRIO 9628 controller for data acquisition and processing including a compression with zero-suppression algorithm. A Linux-RT system working on the 400 MHz Dual-Core CPU is used for FPGA control and data streaming to the higher-level system over 1 Gbps Ethernet connection. 1.2 M frames per second is achieved in so-called burst mode of operation while in zerodead-time mode 70 kfps is possible. Due to efficient data compression in FPGA there’s no need of using high-speed transceivers and Frame-Grabber cards on the data server side and the detector can stream the data infinitely over standard 1 Gbps network connection. Operation modes were tested at Advanced Photon Source Synchrotron at Argonne National Laboratory.

47 OTHER INSTRUMENTATION↗