Search NASA⌕ Search

SEARCH · Search NASA

Results for “Uncertainty analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uncertainty and Sensitivity Analyses of Duct Propagation Models

This paper presents results of uncertainty and sensitivity analyses conducted to assess the relative merits of three duct propagation codes. Results from this study are intended to support identification of a "working envelope" within which to use the various approaches underlying these propagation codes. This investigation considers a segmented liner configuration that models the NASA Langley Grazing Incidence Tube, for which a large set of measured data was available. For the uncertainty analysis, the selected input parameters (source sound pressure level, average Mach number, liner impedance, exit impedance, static pressure and static temperature) are randomly varied over a range of values. Uncertainty limits (95% confidence levels) are computed for the predicted values from each code, and are compared with the corresponding 95% confidence intervals in the measured data. Generally, the mean values of the predicted attenuation are observed to track the mean values of the measured attenuation quite well and predicted confidence intervals tend to be larger in the presence of mean flow. A two-level, six factor sensitivity study is also conducted in which the six inputs are varied one at a time to assess their effect on the predicted attenuation. As expected, the results demonstrate the liner resistance and reactance to be the most important input parameters. They also indicate the exit impedance is a significant contributor to uncertainty in the predicted attenuation.

Nark, Douglas M.↗

Space Radiation Heart Disease Risk Estimates for Lunar and Mars Missions

The NASA Space Radiation Program performs research on the risks of late effects from space radiation for cancer, neurological disorders, cataracts, and heart disease. For mortality risks, an aggregate over all risks should be considered as well as projection of the life loss per radiation induced death. We report on a triple detriment life-table approach to combine cancer and heart disease risks. Epidemiology results show extensive heterogeneity between populations for distinct components of the overall heart disease risks including hypertension, ischaemic heart disease, stroke, and cerebrovascular diseases. We report on an update to our previous heart disease estimates for Heart disease (ICD9 390-429) and Stroke (ICD9 430-438), and other sub-groups using recent meta-analysis results for various exposed radiation cohorts to low LET radiation. Results for multiplicative and additive risk transfer models are considered using baseline rates for US males and female. Uncertainty analysis indicated heart mortality risks as low as zero, assuming a threshold dose for deterministic effects, and projections approaching one-third of the overall cancer risk. Medan life-loss per death estimates were significantly less than that of solid cancer and leukemias. Critical research questions to improve risks estimates for heart disease are distinctions in mechanisms at high doses (>2 Gy) and low to moderate doses (<2 Gy), and data and basic understanding of radiation doserate and quality effects, and individual sensitivity.

Cucinotta, Francis A.↗

CE TSUNAMI-3D Algorithm Improvements in SCALE 6.2

The TSUNAMI (Tools for Sensitivity and Uncertainty Analysis Methodology Implementation) capabilities within the SCALE code system make use of sensitivity coefficients for an extensive number of criticality safety applications such as quantifying the data-induced uncertainty in the eigenvalue of critical systems, assessing the neutronic similarity between different systems, quantifying computational biases, and guiding nuclear data adjustment studies. The continuous-energy (CE) TSUNAMI-3D code is a new tool included in SCALE 6.2 that allows for eigenvalue and generalized response sensitivity calculations using high-fidelity CE Monte Carlo methods. This paper describes several improvements to CE TSUNAMI-3D beyond those previously published. These improvements primarily consist of - A multi-response capability for the CE TSUNAMI generalized response sensitivity calculation mode; and - Efficiency improvements in CE TSUNAMI's Iterated Fission Probability (IFP)-based algorithms. This paper documents several improvements to the CE TSUNAMI-3D sensitivity algorithms included in the SCALE 6.2 release. These improvements have enabled the simulation of multiple GPT responses within a single CE TSUNAMI simulation, a feature that increases the memory footprint of the simulations by approximately 1-3% per response and the runtime by approximately 1-2%, per response. These algorithmic improvements have also significantly improved the computational efficiency of CE TSUNAMI IFP-based sensitivity calculations, reducing the memory footprints approximately by a factor of 3 and the simulation runtimes by 10-70%. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Intercomparison of the representations of the atmospheric chemistry of pre-industrial methane and ozone in earth system and other global chemistry-transport models

An intercomparison has been set up to study the representation of the atmospheric chemistry of the pre-industrial troposphere in earth system and other global tropospheric chemistry-transport models. The intercomparison employed a constrained box model and utilised tropospheric trace gas composition data for the pre-industrial times at ninety mid-latitude surface locations. Incremental additions of four organic compounds: methane, ethane, acetone and propane, were used to perturb the constrained box model and generate responses in hydroxyl radicals and tropospheric ozone at each location and with each chemical mechanism. Although the responses agreed well across the chemical mechanisms from the selected earth system and other global tropospheric chemistry-transport models, there were differences in the detailed responses between the chemical mechanisms that could be tracked down by sensitivity analysis to differences in the representation of C1–C3 chemistry. Inter-mechanism ranges in NOx compensation points were about 0.17 ± 0.12 when expressed relative to the inter-mechanism average. Monte Carlo uncertainty analysis carried out with a single chemical mechanism put the intra-mechanism range a factor of three higher at 0.50 ± 0.12. Similar differences between inter-mechanism and intra-mechanism ranges were found for hydroxyl radical depletion but were up to a factor of six wider for ozone formation from incremental additions of organic compounds. The cause of the discrepancies between the inter- and intra-mechanism ranges was found to be the large uncertainties that are present in the laboratory determinations of the rate coefficients and product channel branching ratios of some key chemical reactions involving organic peroxy radicals and hydroperoxides. Whilst these large uncertainties are present in the laboratory determinations, there will be irreducible uncertainties in the predictions from the earth system and other chemistry-transport models of methane and tropospheric ozone trends since pre-industrial times and hence their contributions to the radiative forcing of climate change. Further definitive laboratory studies of the reaction rates and product yields of the reactions of the simple organic peroxy radicals and hydroperoxides are required to resolve and reduce current uncertainties in earth system and chemistry-transport model predictions.

atmospheric chemistry↗

Plasma performance and operational space with an RMP-ELM suppressed edge

Abstract The operational space and global performance of plasmas with edge-localized modes (ELMs) suppressed by resonant magnetic perturbations (RMPs) are surveyed by comparing AUG, DIII-D, EAST, and KSTAR stationary operating points. RMP-ELM suppression is achieved over a range of plasma currents, toroidal fields, and RMP toroidal mode numbers. Consistent operational windows in edge safety factor are found across devices, while windows in plasma shaping parameters are distinct. Accessed pedestal parameters reveal a quantitatively similar pedestal-top density limit for RMP-ELM suppression in all devices of just over 3 × 10 19 m −3 . This is surprising given the wide variance of many engineering parameters and edge collisionalities, and poses a challenge to extrapolation of the regime. Wide ranges in input power, confinement time, and stored energy are observed, with the achieved triple product found to scale like the product of current, field, and radius. Observed energy confinement scaling with engineering parameters for RMP-ELM suppressed plasmas are presented and compared with expectations from established H and L-mode scalings, including treatment of uncertainty analysis. Different scaling exponents for individual engineering parameters are found as compared to the established scalings. However, extrapolation to next-step tokamaks ITER and SPARC find overall consistency within uncertainties with the established scalings, finding no obvious performance penalty when extrapolating from the assembled multi-device RMP-ELM suppressed database. Overall this work identifies common physics for RMP-ELM suppression and highlights the need to pursue this no-ELM regime at higher magnetic field and different plasma physical size.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Feynman Variance-To-Mean Measurements Using Measured and Simulated Data

Measured and simulated list-mode data from the NPOD detector system were compared for subcritical systems. Five BeRP ball configurations reflected by polyethylene are investigated in this work. The simulated data were calculated using the MCNP multiplication patch developed at LANL. In addition to comparing the moments of the counting distributions, a full analysis was conducted to infer the multiplication of each system using both the Hansen-Dowdy and Hage-Cifarelli formulisms. Several of the parameters that are input into these methods were also varied to determine their affect on the system multiplication. The main parameters investigated included the system source strength, reflector transmission, and the average number of neutrons released per 239 Pu fission ($\nu$). It is shown that when comparing the measured and simulated data while using the same method and parameters the inferred multiplication values agree within 5%. The measured and simulated multiplication values differ more as the reflector thickness increases. The moments for the simulated data were higher than the measured data for all of the configurations and also disagreed more as the reflector thickness increased. The analysis method and parameters used can lead to a large spread of inferred multiplication values. In the future more configurations will be analyzed in a similar manner and a detailed uncertainty analysis will be performed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Techno-economic analysis of long-duration energy storage and flexible power generation technologies to support high-variable renewable energy grids

As variable renewable energy penetration increases beyond 80%, clean power systems will require long-duration energy storage or flexible, low-carbon generation. Here, we provide a detailed techno-economic evaluation and uncertainty analysis of applicable technologies and identify challenges and opportunities to support electric grid planning. We show that for a 120-h storage duration rating, hydrogen systems with geologic storage and natural gas with carbon capture are the least-cost low-carbon technologies for both current and future capital costs. These results are robust to uncertainty for the future capital cost scenario, but adiabatic compressed air and pumped thermal storage could be the least-cost technologies in the current capital cost scenario under uncertainty. Finally, we present a new storage system using heavy-duty vehicle fuel cells that could reduce the levelized cost of energy by 13%–20% compared with the best previously considered storage technology and, thus, could help enable very high (>80%) renewable energy grids.

25 ENERGY STORAGE↗

The VORCOM. Part 1: Analytical considerations

The analytical considerations which support the computation of (1) two components of the velocity vector from an X-array and (2) the transverse vorticity from the X-array and an adjacent parallel wire pair are presented. The electronic circuit which will execute these computations at a 50 khz rate is also described. The factors limiting the accuracy of the measurements are identified and quantitative estimates are given for a typical x-probe. An extensive analysis of the factors which effect the output and which are unknown (or unknowable) during the measurements is presented. Quantitative estimates of these effects are developed in the form of an uncertainty analysis. Numerical values, calculated using the analytical structure of the response equations, are tabulated; other estimates which require special experiments are described.

Foss, J. F.↗

National Climate Assessment - Land Data Assimilation System (NCA-LDAS) Data at NASA GES DISC

As part of NASA's active participation in the Interagency National Climate Assessment (NCA) program, the Goddard Space Flight Center's Hydrological Sciences Laboratory (HSL) is supporting an Integrated Terrestrial Water Analysis, by using NASA's Land Information System (LIS) and Land Data Assimilation System (LDAS) capabilities. To maximize the benefit of the NCA-LDAS, on completion of planned model runs and uncertainty analysis, NASA will provide open access to all NCA-LDAS components, including input data, output fields, and indicator data, to other NCA-teams and the general public. The NCA-LDAS data will be archived at the NASA GES DISC (Goddard Earth Sciences Data and Information Services Center) and can be accessed via direct ftp, THREDDS, Mirador search and download, and Giovanni visualization and analysis system.

land surface↗

Dragonfly Entry and Descent Flight Mechanics Modeling and Analysis for Mission PDR

Dragonfly is a New Frontiers Program mission led by Johns Hopkins Applied Physics Laboratory (APL) which will deliver a rotorcraft lander to Saturn’s moon, Titan [1]. Relative to previous studies presented, Dragonfly recently passed its mission Preliminary Design Review (PDR) [2]. This study presents the updated design and analysis performed for the Dragonfly mission PDR. The entry vehicle analysis includes the phases of entry and descent prior to cruise stage separation until lander separation. These results discuss the robustness of the overall entry sequence as assessed through a Monte Carlo uncertainty analysis as well as sensitivity analysis.

Modeling↗

Quantitative uncertainty and sensitivity analysis of a PWR control rod ejection accident

The paper describes the results of the quantitative Uncertainty and Sensitivity (U/S) Analysis of a Rod Ejection Accident (REA) which is simulated by the coupled system code ATHLET-QUABOX/CUBBOX applying the GRS tool for U/S analysis SUSA/XSUSA. For the present study, a UOX/MOX mixed core loading based on a generic PWR is modeled. A control rod ejection is calculated for two reactor states: Hot Zero Power (HZP) and 30% of nominal power. The worst cases for the rod ejection are determined by steady-state neutronic simulations taking into account the maximum reactivity insertion in the system and the power peaking factor. For the U/S analysis 378 uncertain parameters are identified and quantified (thermal-hydraulic initial and boundary conditions, input parameters and variations of the two-group cross sections). Results for uncertainty and sensitivity analysis are presented for safety important global and local parameters. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simultaneous calibration of surface flow and baseflow simulations: a revisit of the SWAT model calibration framework

Accurate analysis of water flow pathways from rainfall to streams is critical for simulating water use, climate change impact, and contaminants transport. In this study, we developed a new scheme to simultaneously calibrate surface flow (SF) and baseflow (BF) simulations of soil and water assessment tool (SWAT) by combing evolutionary multi-objective optimization (EMO) and BF separation techniques. The application of this scheme demonstrated pronounced trade-off of SWAT’s performance on SF and BF simulations. The simulated major water fluxes and storages variables (e.g. soil moisture, evapotranspiration, and groundwater) using the multiple parameters from EMO span wide ranges. Uncertainty analysis was conducted by Bayesian model averaging of the Pareto optimal solutions. The 90% confidence interval (CI) estimated using all streamflows substantially overestimate the uncertainty of low flows on BF days while underestimating the uncertainty of high flows on SF days. Despite using statistical criteria calculated based on streamflow for model selection, it is important to conduct diagnostic analysis of the agreement of SWAT behaviour and actual watershed dynamics. The new calibration technique can serve as a useful tool to explore the tradeoff between SF and BF simulations and provide candidates for further diagnostic assessment and model identification.

54 ENVIRONMENTAL SCIENCES↗

Issue Summary of INL Phase IV Transient Results for IAEA CRP on HTGR UAM Benchmark

This report details the Parallel and Highly Innovative Simulation for Idaho National Laboratory (INL) Code System (PHISICS)/Reactor Excursions and Leak Analysis Program (RELAP5)-3D results obtained for the transient core exercises defined for Phase IV of the International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP) on high-temperature gas cooled reactor (HTGR) uncertainty analysis in modeling (UAM). The Phase III models and results are linked to the earlier Standardized Computer Analyses for Licensing Evaluation (SCALE)/Sampler/New ESC-based Weighting Transport (NEWT) data generated for the lattice physics (lattice) stage Phase I of the CRP. The focus of this report is the Uncertainty/Sensitivity Assessment (U/SA) of the prismatic modular high-temperature gas cooled reactor (MHTGR)-350 design, and specifically for Exercises IV-1 and IV-2 of the benchmark: the Control Rod Withdrawal (CRW) and Pressurised Loss of Cooling (PLOFC) events. The statistical U/SA methodology is implemented and demonstrated using the RAVEN code, based on perturbed cross-section libraries obtained from the SCALE/Sampler sequence. Uncertainties in nuclear data (cross-sections and the average number of neutrons produced per fission, 235U[¯v ]) lead to standard deviations (uncertainties of one s) of approximately 0.5% in the core eigenvalues of the MHTGR-350 and core models. For the coupled neutronics/thermal fluid model, local power density uncertainties up to 3.6% were observed in the colder regions of the core, while the local maximum fuel temperature uncertainties reached 1.5% for the models that included thermal fluid uncertainties. The addition of thermal fluid uncertainties dominated the impacts of nuclear data uncertainties in all cases. The main contributors to uncertainties in the power density and fuel temperatures during the transients were uncertainties in the reactor operating conditions (total power, inlet mass flow rate and inlet gas temperature). Variations in the bypass flows did not have significant impact on any of the output variables. For the nuclear data uncertainties it was found that the 235U(¯v ) / 235U(¯v ) covariance produced the largest sensitivities in terms of its impact on the eigenvalue and peak reactor power. It was also observed that the impact of any nuclear data uncertainties on the maximum fuel temperature was much less significant that the impact on eigenvalue and power. Another important finding was that although the use of eight or more energy groups is recommended for best-estimate HTGR simulation, two-group models produced acceptable uncertainty and sensitivity results for most FOMs. Since the statistical U/SA methodology is computationally expensive, and most transient solver requirements will scale directly with the number of energy groups, two energy groups could be used by HTGR developers during the early stages of design when larger uncertainty margins can be tolerated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study

Purpose: In gynecological radiotherapy with high dose rate (HDR){sup 192}Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. Methods: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron{sup 192}Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. Results: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. Conclusions: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An introduction to the global positioning system and some geological applications

The fundamental principles of the global positioning system (GPS) are reviewed, with consideration given to geological and geophysical applications and related accuracy requirements. Recent improvements are emphasized which relate to areas such as equipment cost, limitations in the GPS satellite constellation, data analysis, uncertainties in satellite orbits and propagation delays, and problems in resolving carrier phase cycle ambiguities. Earthquake processes and near-fault crustal deformation monitoring have been facilitated by advances in GPS data acquisition and analysis. Horizontal positioning capability has been improved by new satellite constellation, better models, and global tracking networks. New classes of tectonic problems may now be studied through GPS, such as kinematic descriptions of crustal deformation and the measurement of relative plate motion at convergent boundaries. Continued improvements in the GPS are foreseen.

Dixon, T. H.↗

Enhancements in SCALE 6.1

The Standardized Computer Analysis for Licensing Evaluation (SCALE) code system developed at Oak Ridge National Laboratory provides a comprehensive, verified and validated, user-friendly tool set for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, licensees, and research institutions around the world have used SCALE for safety analysis and design. SCALE provides a 'plug-and-play' framework with nearly 80 computational modules, including three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution. SCALE's graphical user interfaces assist with accurate system modeling and convenient access to desired results. SCALE 6.1, scheduled for release in the fall of 2010, provides improved reliability and introduces a number of enhanced features, some of which are briefly described here. SCALE 6.1 provides state-of-the-art capabilities for criticality safety, reactor physics, and radiation shielding in a robust yet user-friendly package. The new features and improved reliability of this latest release of SCALE are intended to improve safety and efficiency throughout the nuclear community.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Kinetic Model-Driven Techno-Economic Analysis of Plastic Pyrolysis: Linking Process Dynamics to Economic Viability

This study employs a kinetic model integrated into Aspen Plus to predict pyrolysis product distribution under various conditions. A techno-economic assessment calculated the minimum selling price (MSP) of pyrolysis oil under different operating conditions for the baseline capacity of 100 kta, and across eight processing capacities ranging from 30 to 150 kta. The lowest MSP under the baseline capacity is estimated at $\$$420/ton, which is 33% lower than the 2023 average US crude oil price ($\$$74.6/bbl, equivalent to $\$$634/ton based on the density of pyrolysis oil). Under Monte Carlo simulation, accounting for variability in key economic and technical parameters, the mean MSP is estimated at $\$$1137/ton. The economic viability depends on feedstock price remaining below $\$$320/ton, defining the break-even feedstock price threshold. Sensitivity analysis further identifies capital investment and transportation cost as key economic drivers. Capacities beyond 90 kta show limited economies of scale benefits. Reducing product storage time cuts capital costs by 7% but raises operational risk. Uncertainty analysis suggests the economic feasibility of pyrolysis oil is unlikely to compete with crude oil without policy incentives.

petrochemicals↗