Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Serum Gamma-Glutamyl-Transferase Independently Predicts Outcome After Transarterial Chemoembolization of Hepatocellular Carcinoma: External Validation

Purpose: An Asian study showed that gamma glutamyl transpeptidase (GGT) can predict survival after transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). This study was designed to validate in a European population this biomarker as an independent predictor of outcome after TACE of HCC and to determine a threshold value for clinical use. Methods: In 88 consecutive patients treated by TACE for HCC, the optimal threshold for GGT serum level was determined by a ROC analysis. Endpoints were time-to-treatment failure (TTTF) and overall survival (OS). All multivariate models were internally validated using bootstrapping (90 replications). Results: Median follow-up lasted 373 days, and median overall survival was 748 days. The optimal threshold for GGT was 165 U/L (sensitivity: 89.3%; specificity: 56.7%; area under the ROC curve: 0.7515). Median TTTF was shorter when GGT was {>=}165 U/L (281 days vs. 850 days; P < 0.001). GGT {>=}165 U/L (hazard ratio (HR) = 2.06; P = 0.02), WHO PS of 2 (HR = 5.4; P = 0.002), and tumor size (HR = 1.12; P = 0.014) were independently associated with shorter TTTF. Median OS was shorter when GGT was {>=}165 U/L (508 days vs. not reached; P < 0.001). GGT {>=} 165 U/L (HR = 3.05; P = 0.029), WHO PS of 2 (HR = 12.95; P < 0.001), alfa-fetoprotein (HR = 2.9; P = 0.01), and tumor size (HR = 1.096; P = 0.013) were independently associated with shorter OS. The results were confirmed by bootstrapping. Conclusions: Our results provide in a European population the external validation of GGT as an independent predictor of outcome after TACE of HCC. A serum level of GGT {>=} 165 U/L is independently associated with both shorter TTTF and OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Mouse Bioluminescence Tomography with Radionuclide-Based Imaging Validation

Introduction: Bioluminescence imaging, especially planar bioluminescence imaging, has been extensively applied in in vivo preclinical biological research. Bioluminescence tomography (BLT) has the potential to provide more accurate imaging information due to its 3D reconstruction compared with its planar counterpart. Methods: In this work, we introduce a positron emission tomography (PET) radionuclide imaging-based strategy to validate the BLT results. X-ray computed tomography, PET, spectrally resolved bioluminescence imaging, and surgical excision were performed on a tumor xenograft mouse model expressing a bioluminescent reporter gene. Results: With different spectrally resolved measured data, the BLT reconstructions were acquired based on the third-order simplified spherical harmonics (SP3) approximation and the diffusion approximation (DA). The corresponding tomographic images were obtained for validation of bioluminescence source reconstruction. Conclusion: Our results show the strength of PET imaging compared with other validation methods for BLT and improved source localization accuracy based on the SP3 approximation compared with the diffusion approximation.

59 BASIC BIOLOGICAL SCIENCES↗

Which nuclear data can be validated with LLNL pulsed-sphere experiments?

It is shown here that 14-MeV D+T LLNL pulsed-sphere experiments bring complementary information into the process of validating nuclear data compared to experiments that are traditionally used for this purpose—such as critical assemblies. To be more specific, the 14-MeV D+T LLNL pulsed-sphere neutron-leakage spectra enable to validate scattering and fission nuclear data up to 15 MeV (compared to approximately up to 5 MeV when using criticality experiments) and employ to this end simple compound targets containing only few isotopes. In this work, sensitivity profiles of the spectra to nuclear data are calculated in order to understand in detail which isotopes, observables, and energy ranges of nuclear data contribute significantly to their simulation. These profiles are presented for a few selected spheres containing 16 O, 12 C, 56 Fe, and 239 Pu. It is shown that the neutron-leakage spectra of spheres containing light elements are mostly sensitive to elastic- and inelastic-scattering cross sections on discrete levels and corresponding angular distributions. Spheres of structural materials are sensitive to elastic- and inelastic-scattering cross sections, including scattering on discrete levels and the continuum, and double-differential cross sections. Actinide spheres are also strongly sensitive to the fission observables, in particular to the total-fission neutron spectrum. Thin spheres (in which neutrons experience on average less than one scatter) are mostly sensitive to data near the elastic peak, in the energy range from 12–15 MeV, while thicker ones can be sensitive to data at lower incident-neutron energies due to multiple-scattering effects. This information is brought together with simulations of 71 pulsed-sphere neutron-leakage spectra using the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear-data libraries. This analysis highlights ENDF/B-VIII.0 data that could be further investigated for potential shortcomings ( 6 Li, 12 C, 16 O, 24-26 Mg, 27 Al, 48 Ti, 56 Fe, and 208 Pb) or are likely reliable ( 1,2 H, 7 Li, 9 Be, 14 N, 235,238 U, and 239 Pu) as indicated by validating with LLNL pulsed-sphere experiments.

14-MeV D+T LLNL pulsed-sphere neutron-leakage spec↗

Verification and Validation of EnergyPlus Phase Change Material Model for Opaque Wall Assemblies

Phase change materials (PCMs) represent a technology that may reduce peak loads and HVAC energy consumption in buildings. A few building energy simulation programs have the capability to simulate PCMs, but their accuracy has not been completely tested. This study shows the procedure used to verify and validate the PCM model in EnergyPlus using a similar approach as dictated by ASHRAE Standard 140, which consists of analytical verification, comparative testing, and empirical validation. This process was valuable, as two bugs were identified and fixed in the PCM model, and version 7.1 of EnergyPlus will have a validated PCM model. Preliminary results using whole-building energy analysis show that careful analysis should be done when designing PCMs in homes, as their thermal performance depends on several variables such as PCM properties and location in the building envelope.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of spatiodemographic estimates produced through data fusion of small area census records and household microdata

Techniques such as Iterative Proportional Fitting have been previously suggested as a means to generate new data with the demographic granularity of individual surveys and the spatial granularity of small area tabulations of censuses and surveys. This article explores internal and external validation approaches for synthetic, small area, household- and individual-level microdata using a case study for Bangladesh. Using data from the Bangladesh Census 2011 and the Demographic and Health Survey, we produce estimates of infant mortality rate and other household attributes for small areas using a variation of an iterative proportional fitting method called P-MEDM. We conduct an internal validation to determine: whether the model accurately recreates the spatial variation of the input data, how each of the variables performed overall, and how the estimates compare to the published population totals. We conduct an external validation by comparing the estimates with indicators from the 2009 Multiple Indicator Cluster Survey (MICS) for Bangladesh to benchmark how well the estimates compared to a known dataset which was not used in the original model. The results indicate that the estimation process is viable for regions that are better represented in the microdata sample, but also revealed the possibility of strong overfitting in sparsely sampled sub-populations.

42 ENGINEERING↗

Efficient modeling of optically-complex, non-coplanar exterior shading: Validation of matrix algebraic methods

It has long been established that shading windows with overhangs, fins, and other types of non-coplanar systems (NCS) is one of the most effective ways of controlling solar heat gains in buildings because they intercept solar radiation prior to entry into the building. Designers however often specify non-opaque materials (e.g., louvers, fritted glass, expanded metal mesh) for these systems in order to admit daylight, reduce lighting energy use, and improve indoor environmental quality. Most simulation tools rely on geometric calculations and radiosity methods to model the solar heat gain impacts of NCS and cannot model optically-complex materials or geometries. For daylighting analysis, optically-complex NCS can be modeled using matrix algebraic methods, although time-efficient parametric analysis has not yet been implemented. Determining the best design and/or material for static or operable NCS that minimize cooling, heating, and lighting energy use and peak demand requires an iterative process. This study describes and validates a matrix algebraic method that enables parametric energy analysis of NCS. Such capabilities would be useful not only for design but also for development of prescriptive energy-efficiency standards, rating and labeling systems for commercial products, development of design guidelines, and development of more optimal NCS technologies. A facade or “F” matrix, which maps the transfer of flux from the NCS to the surface of the window, is introduced and its use is explained. A field study was conducted in a full-scale outdoor testbed to measure the daylight performance of an operable drop-arm awning. Simulated data were compared to measured data in order to validate the models. Results demonstrated model accuracy: simulated workplane illuminance was within 11–13%, surface luminance was within 16–18%, and the daylight glare probability was within 6–9% of measured results. Methods used to achieve accurate results are discussed. Results of the validation of daylighting performance are applicable to solar heat gain performance. Since exterior shading can also significantly reduce peak demand, these models enable stakeholders to more accurately assess HVAC and lighting impacts in support of grid management and resiliency goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of Phasor-Domain Transmission and Distribution Co-simulation Against Electromagnetic Transient Simulation

The rapid deployment of renewable energy resources has led to the widespread use of power electronics in modern power systems. As these systems transition from being dominated by large synchronous machines to increasingly incorporating inverter-based resources (IBRs), traditional methods are becoming inadequate. Addressing this challenge, this paper introduces a scalable phasor-domain T\&D co-simulation framework based on open-source software. It focuses on the framework's validation against the PSCAD Electromagnetic Transient (EMT) analysis tool. The validation results demonstrate the framework's high-fidelity and a computational time speed-up of 60 to 100 times, marking a pioneering validation effort in T\&D co-simulation research.

Inverter-based resources, co-simulation, Electroma↗

Development and External Validation of Prognostic Model for 2-Year Survival of Non-Small-Cell Lung Cancer Patients Treated With Chemoradiotherapy

Purpose: Radiotherapy, combined with chemotherapy, is the treatment of choice for a large group of non-small-cell lung cancer (NSCLC) patients. Recent developments in the treatment of these patients have led to improved survival. However, the clinical TNM stage is highly inaccurate for the prediction of survival, and alternatives are lacking. The objective of this study was to develop and validate a prediction model for survival of NSCLC patients, treated with chemoradiotherapy. Patients and Methods: The clinical data from 377 consecutive inoperable NSCLC patients, Stage I-IIIB, treated radically with chemoradiotherapy were collected. A prognostic model for 2-year survival was developed, using 2-norm support vector machines. The performance of the model was expressed as the area under the curve of the receiver operating characteristic and assessed using leave-one-out cross-validation, as well as two external data sets. Results: The final multivariate model consisted of gender, World Health Organization performance status, forced expiratory volume in 1 s, number of positive lymph node stations, and gross tumor volume. The area under the curve, assessed by leave-one-out cross-validation, was 0.74, and application of the model to the external data sets yielded an area under the curve of 0.75 and 0.76. A high- and low-risk group could be clearly identified using a risk score based on the model. Conclusion: The multivariate model performed very well and was able to accurately predict the 2-year survival of NSCLC patients treated with chemoradiotherapy. The model could support clinicians in the treatment decision-making process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Imaging With Pathology in Laryngeal Cancer: Accuracy of the Registration Methodology

Purpose: To investigate the feasibility and accuracy of an automated method to validate gross tumor volume (GTV) delineations with pathology in laryngeal and hypopharyngeal cancer. Methods and Materials: High-resolution computed tomography (CT{sub HR}), magnetic resonance imaging (MRI), and positron emission tomography (PET) scans were obtained from 10 patients before total laryngectomy. The GTV was delineated separately in each imaging modality. The laryngectomy specimen was sliced transversely in 3-mm-thick slices, and whole-mount hematoxylin-eosin stained (H and E) sections were obtained. A pathologist delineated tumor tissue in the H and E sections (GTV{sub PATH}). An automatic three-dimensional (3D) reconstruction of the specimen was performed, and the CT{sub HR}, MRI, and PET were semiautomatically and rigidly registered to the 3D specimen. The accuracy of the pathology-imaging registration and the specimen deformation and shrinkage were assessed. The tumor delineation inaccuracies were compared with the registration errors. Results: Good agreement was observed between anatomical landmarks in the 3D specimen and in the in vivo images. Limited deformations and shrinkage (3% {+-} 1%) were found inside the cartilage skeleton. The root mean squared error of the registration between the 3D specimen and the CT, MRI, and PET was on average 1.5, 3.0, and 3.3 mm, respectively, in the cartilage skeleton. The GTV{sub PATH} volume was 7.2 mL, on average. The GTVs based on CT, MRI, and PET generated a mean volume of 14.9, 18.3, and 9.8 mL and covered the GTV{sub PATH} by 85%, 88%, and 77%, respectively. The tumor delineation inaccuracies exceeded the registration error in all the imaging modalities. Conclusions: Validation of GTV delineations with pathology is feasible with an average overall accuracy below 3.5 mm inside the laryngeal skeleton. The tumor delineation inaccuracies were larger than the registration error. Therefore, an accurate histological validation of anatomical and functional imaging techniques for GTV delineation is possible in laryngeal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Validation of 4-Dimensional Computed Tomography Ventilation With Pulmonary Function Test Data

Purpose: A new form of functional imaging has been proposed in the form of 4-dimensional computed tomography (4DCT) ventilation. Because 4DCTs are acquired as part of routine care for lung cancer patients, calculating ventilation maps from 4DCTs provides spatial lung function information without added dosimetric or monetary cost to the patient. Before 4DCT-ventilation is implemented it needs to be clinically validated. Pulmonary function tests (PFTs) provide a clinically established way of evaluating lung function. The purpose of our work was to perform a clinical validation by comparing 4DCT-ventilation metrics with PFT data. Methods and Materials: Ninety-eight lung cancer patients with pretreatment 4DCT and PFT data were included in the study. Pulmonary function test metrics used to diagnose obstructive lung disease were recorded: forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity. Four-dimensional CT data sets and spatial registration were used to compute 4DCT-ventilation images using a density change–based and a Jacobian-based model. The ventilation maps were reduced to single metrics intended to reflect the degree of ventilation obstruction. Specifically, we computed the coefficient of variation (SD/mean), ventilation V20 (volume of lung ≤20% ventilation), and correlated the ventilation metrics with PFT data. Regression analysis was used to determine whether 4DCT ventilation data could predict for normal versus abnormal lung function using PFT thresholds. Results: Correlation coefficients comparing 4DCT-ventilation with PFT data ranged from 0.63 to 0.72, with the best agreement between FEV1 and coefficient of variation. Four-dimensional CT ventilation metrics were able to significantly delineate between clinically normal versus abnormal PFT results. Conclusions: Validation of 4DCT ventilation with clinically relevant metrics is essential. We demonstrate good global agreement between PFTs and 4DCT-ventilation, indicating that 4DCT-ventilation provides a reliable assessment of lung function. Four-dimensional CT ventilation enables exciting opportunities to assess lung function and create functional avoidance radiation therapy plans. The present work provides supporting evidence for the integration of 4DCT-ventilation into clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective, Multicenter Validation Study of Magnetic Resonance Volumetry for Response Assessment After Preoperative Chemoradiation in Rectal Cancer: Can the Results in the Literature be Reproduced?

Purpose: To review the available literature on tumor size/volume measurements on magnetic resonance imaging for response assessment after chemoradiotherapy, and validate these cut-offs in an independent multicenter patient cohort. Methods and Materials: The study included 2 parts. (1) Review of the literature: articles were included that assessed the accuracy of tumor size/volume measurements on magnetic resonance imaging for tumor response assessment. Size/volume cut-offs were extracted; (2) Multicenter validation: extracted cut-offs from the literature were tested in a multicenter cohort (n=146). Accuracies were calculated and compared with reported results from the literature. Results: The review included 14 articles, in which 3 different measurement methods were assessed: (1) tumor length; (2) 3-dimensonial tumor size; and (3) whole volume. Study outcomes consisted of (1) complete response (ypT0) versus residual tumor; (2) tumor regression grade 1 to 2 versus 3 to 5; and (3) T-downstaging (ypT<cT). In the multicenter cohort, best results were obtained for the validation of the whole-volume measurements, in particular for the outcome ypT0 (accuracy 44%-80%), with the optimal cut-offs being 1.6 cm{sup 3} (after chemoradiation therapy) and a volume reduction of Δ80% to 86.6%. Accuracies for whole-volume measurements to assess tumor regression grade 1 to 2 were 52% to 61%, and for T-downstaging 51% to 57%. Overall accuracies for tumor length ranged between 48% and 53% and for 3D size measurement between 52% and 56%. Conclusions: Magnetic resonance volumetry using whole-tumor volume measurements can be helpful in rectal cancer response assessment with selected cut-off values. Measurements of tumor length or 3-dimensional tumor size are not helpful. Magnetic resonance volumetry is mainly accurate to assess a complete tumor response (ypT0) after chemoradiation therapy (accuracies up to 80%).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of High-Risk Computed Tomography Features for Detection of Local Recurrence After Stereotactic Body Radiation Therapy for Early-Stage Non-Small Cell Lung Cancer

Purpose: Fibrotic changes after stereotactic body radiation therapy (SBRT) for stage I non-small cell lung cancer (NSCLC) are difficult to distinguish from local recurrences (LR), hampering proper patient selection for salvage therapy. This study validates previously reported high-risk computed tomography (CT) features (HRFs) for detection of LR in an independent patient cohort. Methods and Materials: From a multicenter database, 13 patients with biopsy-proven LR were matched 1:2 to 26 non-LR control patients based on dose, planning target volume (PTV), follow-up time, and lung lobe. Tested HRFs were enlarging opacity, sequential enlarging opacity, enlarging opacity after 12 months, bulging margin, linear margin disappearance, loss of air bronchogram, and craniocaudal growth. Additionally, 2 new features were analyzed: the occurrence of new unilateral pleural effusion, and growth based on relative volume, assessed by manual delineation. Results: All HRFs were significantly associated with LR except for loss of air bronchogram. The best performing HRFs were bulging margin, linear margin disappearance, and craniocaudal growth. Receiver operating characteristic analysis of the number of HRFs to detect LR had an area under the curve (AUC) of 0.97 (95% confidence interval [CI] 0.9-1.0), which was identical to the performance described in the original report. The best compromise (closest to 100% sensitivity and specificity) was found at ≥4 HRFs, with a sensitivity of 92% and a specificity of 85%. A model consisting of only 2 HRFs, bulging margin and craniocaudal growth, resulted in a sensitivity of 85% and a specificity of 100%, with an AUC of 0.96 (95% CI 0.9-1.0) (HRFs ≥2). Pleural effusion and relative growth did not significantly improve the model. Conclusion: We successfully validated CT-based HRFs for detection of LR after SBRT for early-stage NSCLC. As an alternative to number of HRFs, we propose a simplified model with the combination of the 2 best HRFs: bulging margin and craniocaudal growth, although validation is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Plasma Levels of IL-8 and TGF-β1 Predict Radiation-Induced Lung Toxicity in Non-Small Cell Lung Cancer: A Validation Study

Purpose and Objectives: We previously reported that the combination of mean lung dose (MLD) and inflammatory cytokines interleukin-8 (IL-8) and transforming growth factor-β1 (TGF-β1) may provide a more accurate model for radiation-induced lung toxicity (RILT) prediction in 58 patients with non-small cell lung cancer (NSCLC). This study is to validate the previous findings with new patients and to explore new models with more cytokines. Methods and Materials: One hundred forty-two patients with stage I-III NSCLC treated with definitive radiation therapy (RT) from prospective studies were included. Sixty-five new patients were used to validate previous findings, and all 142 patients were used to explore new models. Thirty inflammatory cytokines were measured in plasma samples before RT and 2 weeks and 4 weeks during RT (pre, 2w, 4w). Grade ≥2 RILT was defined as grade 2, and higher radiation pneumonitis or symptomatic pulmonary fibrosis was the primary endpoint. Logistic regression was performed to evaluate the risk factors of RILT. The area under the curve (AUC) for the receiver operating characteristic curves was used for model assessment. Results: Sixteen of 65 patients (24.6%) experienced RILT2. Lower pre IL-8 and higher TGF-β1 2w/pre ratio were associated with higher risk of RILT2. The AUC increased to 0.73 by combining MLD, pre IL-8, and TGF-β1 2w/pre ratio compared with 0.61 by MLD alone to predict RILT. In all 142 patients, 29 patients (20.4%) experienced grade ≥2 RILT. Among the 30 cytokines measured, only IL-8 and TGF-β1 were significantly associated with the risk of RILT2. MLD, pre IL-8 level, and TGF-β1 2w/pre ratio were included in the final predictive model. The AUC increased to 0.76 by combining MLD, pre IL-8, and TGF-β1 2w/pre ratio compared with 0.62 by MLD alone. Conclusions: We validated that a combination of mean lung dose, pre IL-8 level, and TGF-β1 2w/pre ratio provided a more accurate model to predict the risk of RILT2 compared with MLD alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First-In-Human Validation of CT-Based Proton Range Prediction Using Prompt Gamma Imaging in Prostate Cancer Treatments

Uncertainty in computed tomography (CT)-based range prediction substantially impairs the accuracy of proton therapy. Direct determination of the stopping-power ratio (SPR) from dual-energy CT (DECT) has been proposed (DirectSPR), and initial validation studies in phantoms and biological tissues have proven a high accuracy. However, a thorough validation of range prediction in patients has not yet been achieved by any means. Here, we present the first systematic validation of CT-based proton range prediction in patients using prompt gamma imaging (PGI).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systematic validation of non-equilibrium thermochemical models using Bayesian inference

The validation process proposed by Babuška et al. [1] is applied to thermochemical models describing post-shock flow conditions. In this validation approach, experimental data is involved only in the calibration of the models, and the decision process is based on quantities of interest (QoIs) predicted on scenarios that are not necessarily amenable experimentally. Moreover, uncertainties present in the experimental data, as well as those resulting from an incomplete physical model description, are propagated to the QoIs. We investigate four commonly used thermochemical models: a one-temperature model (which assumes thermal equilibrium among all inner modes), and two-temperature models developed by Macheret et al. [2], Marrone and Treanor [3], and Park [4]. Up to 16 uncertain parameters are estimated using Bayesian updating based on the latest absolute volumetric radiance data collected at the Electric Arc Shock Tube (EAST) installed inside the NASA Ames Research Center. Following the solution of the inverse problems, the forward problems are solved in order to predict the radiative heat flux, QoI, and examine the validity of these models. Our results show that all four models are invalid, but for different reasons: the one-temperature model simply fails to reproduce the data while the two-temperature models exhibit unacceptably large uncertainties in the QoI predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and validation of a quantitative proton NMR method for the analysis of pregnenolone

Pregnenolone (PREG) is an endogenous steroid frequently sold as an over-the-counter dietary supplement touted to promote neurological and immunological health. While the PREG dietary supplement is added to the diet for health benefits, there are no FDA approved PREG drugs. However, compounded PREG drug products are available to U.S. patients. The FDA works with state regulatory authorities on the oversight of compounding activities, including developing 503A and 503B lists of bulk substances that compounders are permitted to use. PREG is one of the substances publicly nominated to be included on the 503B list. Compounded hormone therapies such as those using PREG are of interest given the lack of standardization in compounded drug products which may increase the possibility of underdosing, overdosing, or contamination. However, no USP monograph currently exists to evaluate the quality of PREG drug substance or product. To address knowledge gaps and assist in quality control, a simple and rapid quantitative proton nuclear magnetic resonance spectroscopy (qNMR) method for the identification and assay of PREG in different types of PREG products was developed and validated. PREG samples were characterized using 1D 1 H and 2D 1 H– 13 C HSQC NMR spectra. The qNMR assay method (taking approximately 10 min per NMR spectrum) was validated for precision, accuracy, specificity, robustness and linearity per ICH Q2(R1) guidance. The method was validated in a range from 0.032 to 3.2 mg/mL. As a proof of concept, seven PREG bulk substance samples, three tablet and two capsule PREG dietary supplements were assessed by the qNMR analytical procedure. NMR data from all tested samples met the expected criteria for identification and assay. The results demonstrate the potential of qNMR for the quality assessment of different types of PREG samples.

60 APPLIED LIFE SCIENCES↗

Validation of electron backscattering in the MCNP6.3 code

A new electron backscattering validation suite has been developed for the MCNP® code. The calculations in this suite cover both condensed history and single-event transport methods, seven different elemental materials ranging from beryllium to uranium, and incident electron energies from 200 eV to 14.1 MeV. In general, the accuracy of the MCNP code for electron backscattering calculations is energy-dependent. For incident electron energies below 2 keV, the condensed history method is not applied while the single-event method shows poor agreement with experimental measurements due to poor accuracy of the underlying atomic data. For incident energies between 2 keV and 256 keV, the single-event method typically shows better agreement with experiments, while for incident energies above 256 keV the condensed history method gives better accuracy. Additionally, agreement with experimental data is generally worse for low- Z materials such as beryllium and carbon, which may reflect deficiencies in the data or physics underlying electron transport through light elements in the MCNP code. The new electron backscattering validation suite, along with the previously introduced electron stopping power and Lockwood energy deposition validation suites, provide MCNP users with a quantified understanding of the uncertainties in electron transport calculations. Future improvements to electron transport in the MCNP code are necessary for low energies (≤ 2 keV) and for low- Z materials.

36 MATERIALS SCIENCE↗

Undesirable Flow Behavior in a Proposed Validation Data Set

The next generation nuclear plant (NGNP), whose development is supported by the U. S. Department of Energy, will be a very high temperature reactor (VHTR). The VHTR is a single-phase helium-cooled reactor that will provide helium at up to 1000 C. The prospect of a coolant at these temperatures circulating in the reactor vessel demands that careful analysis be performed to ensure that excessively hot spots are not created and that sufficient mixing of the coolant is obtained. Computational fluid dynamics (CFD) coupled with heat transfer will be used to perform the desired analyses. However, primarily because of the imperfect nature of modeling turbulent flow, any CFD calculations used to perform nuclear reactor safety analysis must be validated against experimental data. Experimental data have been taken in a scaled section of the lower plenum of a prismatic VHTR at the matched index of refraction (MIR) facility at the Idaho National Laboratory. These data were taken with the intent that they be examined for use as validation data. A series of investigations have been conducted to assess the MIR data. Issues that have already been examined include the extent of the required computational domain, the outlet boundary condition, the inlet data and the effect of the turbulence model. One of the jets that flow into the model impacts on a wedge, which represents a portion of a hexagonal graphite block that lines the inner wall of the lower plenum. The nature of the flow below this particular jet is such that a randomly varying recirculation zone is created. This recirculation zone is seen to change in size, causing a relatively long-time scale of motion or disturbance of the flow in the model. It is concluded that such a feature is undesirable in a validation data set, firstly because of its apparent random nature and, secondly, because to obtain an appropriate long-time average would be impractical because of the compute time required. It is predicted computationally that by eliminating the first of the four inlet jets into the scaled model, the resulting recirculation zone is rendered stable.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗