Search NASA⌕ Search

SEARCH · Search NASA

Results for “Well Test Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

The relation of flux transfer events to magnetic reconnection

Preliminary results of a search for heat-transfer signatures in electron data on 31 flux-transfer events (FTEs) are reported. Strong acceleration or deceleration, large parallel pressure anisotropies, and temperatures and densities between those of the magnetosphere and the magnetosheath are commonly observed within the surface of the flux-transfer interval defined by the heat-flow peaks, with some evidence of field-aligned ionospheric electrons. A theoretical model is developed to explain some of the observations and illustrated with diagrams. Dynamical tests on a large well-resolved FTE show that the data are consistent with a one-sided passage of the probe into and out of a rotational shear layer.

Scudder, J. D.↗

An Examination of Causes of Multi-Wire Bias during SLD Instrumentation Testing in the IRT

The Icing Research Tunnel (IRT) at NASA Glenn Research Center has been using the SEA Multi-Element Sensor (aka, the multi-wire) as its primary liquid water content instrument since 2011. Recent tests in the IRT with four different multi-wire probes (i.e., different serial numbers) have indicated situations that can result in biasing of the probe data. The reference data used in this report are multi-wire data that have been proven to agree well with the icing blade in low-impingement rate conditions. Data from these recent tests suggest that the presence of a canister probe located 4.45 ft axially downstream and 2.5 ft to the side may have caused multi-wire data to read around 5% low at an airspeed of 150 kts. Additionally, two probes of different serial numbers were observed to measure 5-15% lower than the reference probes, and the causes have been linked to excessive solder on the sensing element and to an out of date element calibration. For these reasons, the authors suggest the community be aware of the possible aerodynamic influences on the probe inlet and outlet, as well as the importance of regular calibration and maintenance of the probes.

aircraft icing↗

An Examination of Causes of Multi-Wire Bias During SLD Instrumentation Testing in the IRT

The Icing Research Tunnel (IRT) at NASA Glenn Research Center has been using the SEA Multi-Element Sensor (aka, the multi-wire) as its primary liquid water content instrument since 2011. Recent tests in the IRT with four different multi-wire probes (i.e., different serial numbers) have indicated situations that can result in biasing of the probe data. The reference data used in this report are multi-wire data that have been proven to agree well with the icing blade in low-impingement rate conditions. Data from these recent tests suggest that the presence of a canister probe located 4.45 ft axially downstream and 2.5 ft to the side may have caused multi-wire data to read around 5% low at an airspeed of 150 kts. Additionally, two probes of different serial numbers were observed to measure 5-15% lower than the reference probes, and the causes have been linked to excessive solder on the sensing element and to an out of date element calibration. For these reasons, the authors suggest the community be aware of the possible aerodynamic influences on the probe inlet and outlet, as well as the importance of regular calibration and maintenance of the probes.

aircraft icing↗

Installed Transonic 2D Nozzle Nacelle Boattail Drag Study

The Transonic Nozzle Boattail Drag Study was initiated in 1995 to develop an understanding of how external nozzle transonic aerodynamics effect airplane performance and how strongly those effects are dependent on nozzle configuration (2D vs. axisymmetric). MDC analyzed the axisymmetric nozzle. Boeing subcontracted Northrop-Grumman to analyze the 2D nozzle. AU participants analyzed the AGARD nozzle as a check-out and validation case. Once the codes were checked out and the gridding resolution necessary for modeling the separated flow in this region determined, the analysis moved to the installed wing/body/nacelle/diverter cases. The boat tail drag validation case was the AGARD B.4 rectangular nozzle. This test case offered both test data and previous CFD analyses for comparison. Results were obtained for test cases B.4.1 (M=0.6) and B.4.2 (M=0.938) and compared very well with the experimental data. Once the validation was complete a CFD grid was constructed for the full Ref. H configuration (wing/body/nacelle/diverter) using a combination of patched and overlapped (Chimera) grids. This was done to ensure that the grid topologies and density would be adequate for the full model. The use of overlapped grids allowed the same grids from the full configuration model to be used for the wing/body alone cases, thus eliminating the risk of grid differences affecting the determination of the installation effects. Once the full configuration model was run and deemed to be suitable the nacelle/diverter grids were removed and the wing/body analysis performed. Reference H wing/body results were completed for M=0.9 (a=0.0, 2.0, 4.0, 6.0 and 8.0), M=1.1 (a=4.0 and 6.0) and M=2.4 (a=0.0, 2.0, 4.4, 6.0 and 8.0). Comparisons of the M=0.9 and M=2.4 cases were made with available wind tunnel data and overall comparisons were good. The axi-inlet/2D nozzle nacelle was analyzed isolated. The isolated nacelle data coupled with the wing/body result enabled the interference effects of the installed nacelles to be determined. Isolated nacelle mm were made at M=0.9 and M=1.1 for both the supersonic and transonic nozzle settings. AU of the isolated nacelle cases were run at alpha=0. Full configuration runs were to be made at Mach numbers of 0.9, 1.1, and 2.4 (the same as the wing/body and isolated nacelles). Both the isolated nacelles and installed nacelles were run with inlet conditions designed to give zero spillage. This was to be done in order to isolate the boattail effects as much as possible. Full configuration runs with the supersonic nozzles were completed for M=0.9 and 1.1 at a=4.0 and 6.0 (4 runs total) and with the transonic nozzles at M=0.9 and 1.1 at a=2.0, 4.0 and 6.0 (6 runs total). Drag breakdowns were completed for the M=0.9 and M= 1.1 showing favorable interference drag for both cases.

Malone, Michael B.↗

Development and Testing of Neutron Cross Section Covariance Data for SCALE 6.2

Neutron cross-section covariance data are essential for many sensitivity/uncertainty and uncertainty quantification assessments performed both within the TSUNAMI suite and more broadly throughout the SCALE code system. The release of ENDF/B-VII.1 included a more complete set of neutron cross-section covariance data: these data form the basis for a new cross-section covariance library to be released in SCALE 6.2. A range of testing is conducted to investigate the properties of these covariance data and ensure that the data are reasonable. These tests include examination of the uncertainty in critical experiment benchmark model k eff values due to nuclear data uncertainties, as well as similarity assessments of irradiated pressurized water reactor (PWR) and boiling water reactor (BWR) fuel with suites of critical experiments. The contents of the new covariance library, the testing performed, and the behavior of the new covariance data are described in this paper. The neutron cross-section covariances can be combined with a sensitivity data file generated using the TSUNAMI suite of codes within SCALE to determine the uncertainty in system k eff caused by nuclear data uncertainties. The Verified, Archived Library of Inputs and Data (VALID) maintained at Oak Ridge National Laboratory (ORNL) contains over 400 critical experiment benchmark models, and sensitivity data are generated for each of these models. The nuclear data uncertainty in k eff is generated for each experiment, and the resulting uncertainties are tabulated and compared to the differences in measured and calculated results. The magnitude of the uncertainty for categories of nuclides (such as actinides, fission products, and structural materials) is calculated for irradiated PWR and BWR fuel to quantify the effect of covariance library changes between the SCALE 6.1 and 6.2 libraries. One of the primary applications of sensitivity/uncertainty methods within SCALE is the assessment of similarities between benchmark experiments and safety applications. This is described by a c k value for each experiment with each application. Several studies have analyzed typical c k values for a range of critical experiments compared with hypothetical irradiated fuel applications. The c k value is sensitive to the cross-section covariance data because the contribution of each nuclide is influenced by its uncertainty; large uncertainties indicate more likely bias sources and are thus given more weight. Changes in c k values resulting from different covariance data can be used to examine and assess underlying data changes. These comparisons are performed for PWR and BWR fuel in storage and transportation systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identification and Study of Validation Level Test Cases for Computational Modeling of Non-Charring Ablators

Computational modeling of Thermal Protection System (TPS) materials, used for aerospace applications, provides numerous advantages in preliminary selection and design of a heatshield material and shape for atmospheric entry vehicles. However, to serve as a reliable tool for prediction of material thermal and ablative behavior, the modeling approach needs to be validated against real experimental and flight data, preferably at a range of applied conditions. The validation study is typically very complex as it requires reliable measured data not only for the material thermal response and surface recession, but also well characterized environmental conditions. The validation problem becomes even more complex when the material thermal response is dictated by multi-physics effects such as solid conduction, in-depth thermal decomposition, pyrolysis gas flow and chemical reactions. The multi-physics effects complicate not only the modeling effort, but also the experimental measurement for validation of various aspects of the highly coupled problem. In this study, an attempt is made to identify suitable experimental data that could serve as a source for validation of material thermal response modeling tools. To reduce the computational complexity, this study focuses only on non-charring ablators, where the material thermal response could be modeled with a single governing equation for solid conduction and the ablation is limited only to the surface of the material. With a well characterized and publicly available experimental data being sparse, the study is limited in presenting test cases for only three materials: camphor, graphite and FiberForm® in the sequence of increased modeling complexity. Graphite is a commonly used TPS material for aerospace applications, both for leading edges of high-speed vehicles and internal insulation of solid rocket motors. FiberForm® is a porous carbon pre-form used in preparation of the well known PICA material Tran et al. [1996]. Inclusion of camphor into the list is conditioned with the relative simplicity in modeling the material thermal and chemical response and the low-enthalpy flow environment. In addition, camphor has been used as a simple test material for study of flow transition behavior by Stock and Ginoux [1973] and assessment of a heatshield shape change at flight relevant conditions by Rotondi et al. [2022]. In this work, the identified experimental data was extracted from the public literature and test cases that yet have been published. As it was found from the review, not a single test case contains an exhaustive set of data that would validate every aspect of the material physics. However, in the data collected, various aspects of the material behavior can be still validated, such as surface and in-depth temperature, amount of recession and a shape change. The identified experimental data for each case is accompanied with a characterized flow environment and simulated boundary conditions predicted by a Data-Parallel Line Relaxation (DPLR) code Wright et al. [1998]. In addition, material thermal response numerical simulations in each test case are performed with Kentucky Aerothermodynamics and Thermal Response System (KATS-MR) Zibitsker et al. [2022] providing a comparative study and a sanity check for the proposed validation data. Sample results from the performed numerical study are shown below. Figure 1 shows distribution of surface heat flux and pressure values on a hemi-cylinder model made of FiberForm® and tested in HyMETS arc-jet facility. The results are shown for the high pressure condition among the two tests. Flow simulation was performed with DPLR code on a quarter of original geometry. In the figure, the quarter shape was mirrored across zx and xy planes to show the complete distribution. Figure 2 shows the material response results for the high pressure case (7500 Pa), simulated with KATS-MR and a comparison to the experimental data for the surface temperature and shape shape. The simulation was performed on a 2-D slice, extracted in the xy plane at the middle of the sample. Figure 3 shows the material response simulation for the low pressure case (3500 Pa) and a comparison to the experimental data for surface temperature and shape change.

ablation↗

Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests

Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative to volcanic-rock units is exemplified by the large difference in their estimated maximum hydraulic conductivity; 4,000 and 400 feet per day, respectively. Simulated minimum estimates of hydraulic conductivity are inexact and represent the lower detection limit of the method. Minimum thicknesses of lithologic intervals also were defined for comparing AnalyzeHOLE results to hydraulic properties in regional ground-water flow models.

58 GEOSCIENCES↗

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Stimulation Pressure and Circulation Data April, 2024

This dataset consists of all of the pressure pumping data for Utah FORGE Well16A78-32 fracturing stages, Well 16B78-32 fracturing stages, and a 9-hour circulation test which took place after all of the frac plugs were drilled out. Fracturing in the wells took place in stages from April 3rd to April 17th, while the circulation test occurred on April 27th, 2024. Data is in excel files, with ReadMe files for each of the .zip folders that detail what data is available. Also attached here is wellhead pressure data from Pason that is referred to in the ReadMe files.

15 GEOTHERMAL ENERGY↗

Application of machine learning to characterize gas hydrate reservoirs in Mackenzie Delta (Canada) and on the Alaska north slope (USA)

Here, artificial neural network-trained models were used to predict gas hydrate saturation distributions in permafrost-associated deposits in the Eileen Gas Hydrate Trend on the Alaska North Slope (ANS), USA and at the Mallik research site in the Beaufort-Mackenzie Basin, Northwest Territories, Canada. The database of Logging-While-Drilling (LWD) and wireline logs collected at five wells (Mount Elbert, Ignik Sikumi, and Kuparuk 7–11–12 wells at ANS, plus 2L-38 and 5L-38 wells at the Mallik research site) includes more than 10,000 depth points, which were used for training, validation, and testing the machine learning (ML) models. Data used in training the ML models include the well logs of density, porosity, electrical resistivity, gamma radiation, and acoustic wave velocity measurements. Combinations of two or three out of these five well logs were found to reliably predict the gas hydrate saturation with accuracy varying between 80 and 90% when compared to the gas hydrate saturations derived from Nuclear Magnetic Resonance (NMR)-based technique. The ML models trained on data from three ANS wells achieved high fidelity predictions of gas hydrate saturation at the Mallik site. The results obtained in this study indicate that ML models trained on data from one geological basin can successfully predict key reservoir parameters for permafrost-associated gas hydrate accumulations within another basin. A generalized approach for selecting a well log combination that can improve model accuracy is discussed. Overall, the study outcome supports earlier work demonstrating that ML models trained on non-NMR well logs are a viable alternative to physics-driven methods for predicting gas hydrate saturations.

58 GEOSCIENCES↗

The Video Guidance Sensor- A Flight Proven Technology

The Video Guidance Sensor (VGS) flew on Shuttle mission STS-95 in October of 1998 to test the VGS functional characteristics on orbit. This was the second flight of the VGS, and during these two flights, both long range and short range data were gathered under a variety of lighting conditions, orbital exposure times, and temperatures. The flight experiment sensor was designed to operate from 1.5 meter range out to 110 meter range, with a field-of-view of 16 X 21 degrees. The VGS tracked its target at a 5 Hz rate and returned 6-degree-of-freedom information on the target's position and attitude relative to the sensor. The VGS was mounted in the Shuttle cargo bay, and its target was mounted on the Spartan spacecraft being carried on this mission. The VGS is a sensor designed to allow an automated vehicle to dock with a spacecraft equipped with a passive target. The VGS is a part of an Automated Rendezvous and Capture (AR&C) system being developed and tested by NASA. The orbital testing included operations with the target on the Shuttle's Remote Manipulator System (RMS) near the start of each flight of the VGS, long-range data (on the STS-95 flight) during the Shuttle rendezvous with the Spartan two days later, and some more RMS operations later in the mission. The data returned from the orbital testing included VGS diagnostics, acquisition, and tracking data, RMS positions, hand-held laser range data, tapes of the data from the VGS video camera, and orbital positioning data from the Spartan and the Shuttle to allow correlation of the VGS data with orbital best-estimate-of-truth data. The Video Guidance Sensor performed well in all phases of the testing, and the VGS is being incorporated into the ground testing of a complete automated rendezvous and docking system. Work on the development of the next generation VGS is continuing.

Howard, Richard T.↗

On Orbit Testing of the Video Guidance Sensor

The Video Guidance Sensor (VGS), part of NASA's Automated Rendezvous and Capture program, was flown on Shuttle mission STS-95 in October of 1998 to orbitally test the functional characteristics of the VGS. This was the second flight of the VGS (the first flight was in 1997 on STS-87), and this time long-range tracking data was gathered during the experiment. The flight experiment sensor was designed to operate from 1.5 meter range out to 110 meter range, with a field-of-view of 16 X 21 degrees. The VGS tracked its target at a 5 Hz rate and returned 6-degree-of-freedom information on the target's position and attitude relative to the sensor. The VGS was mounted in the Shuttle cargo bay, and its target was mounted on the Spartan spacecraft being carried on this mission. The orbital testing of the VGS included operations with the target on the Shuttle's Remote Manipulator System (RMS) at the start of the 10-day mission, long-range data during the Shuttle rendezvous with the Spartan two days later, and some more RMS operations later in the mission. The data returned from the orbital testing included VGS diagnostics, acquisition, and tracking data, RMS positions, hand-held laser range data, tapes of the data from the VGS video camera, and orbital positioning data from the Spartan and the Shuttle to allow correlation of the VGS data with orbital best-estimate-of-truth data. The Video Guidance Sensor performed well in all phases of the testing, and the VGS is being incorporated into the ground testing of a complete automated rendezvous and docking system. Work on the development of the next generation VGS is continuing

Howard, Richard T.↗

Repeatable and reproducible measurements of myocardial oxidative metabolism, blood flow and external efficiency using {sup 11}C-acetate PET

Background: Non-invasive approaches to investigate myocardial efficiency can help track the progression of heart failure (HF). This study evaluates the repeatability and reproducibility of {sup 11}C-acetate positron emission tomography (PET) imaging of oxidative metabolism. Methods and results: Dynamic {sup 11}C-acetate PET scans were performed at baseline and followup (47 ± 22 days apart) in 20 patients with stable HF with reduced ejection fraction. Two observers blinded to patients’ clinical data used FlowQuant{sup ®} to evaluate test–retest repeatability, as well as intra- and inter-observer reproducibility of {sup 11}C-acetate tracer uptake and clearance rates, for the measurement of myocardial oxygen consumption (MVO{sub 2}), myocardial external efficiency (MEE), work metabolic index (WMI), and myocardial blood flow. Reproducibility and repeatability were evaluated using intra-class-correlation (ICC) and Bland–Altman coefficient-of-repeatability (CR). Test–retest correlations and repeatability were better for MEE and WMI compared to MVO{sub 2}. All intra- and inter-observer correlations were excellent (ICC = 0.95-0.99) and the reproducibility values (CR = 3%-6%) were significantly lower than the test–retest repeatability values (22%-54%, P < 0.001). Repeatability was improved for all parameters using a newer PET–computed tomography (CT) scanner compared to older PET-only instrumentation. Conclusion: {sup 11}C-acetate PET measurements of WMI and MEE exhibited excellent test–retest repeatability and operator reproducibility. Newer PET–CT scanners may be preferred for longitudinal tracking of cardiac efficiency. [French] French Abstract: Contexte: Les examens non invasifs de la fonction myocardique aident à suivre la progression de l’insuffisance cardiaque. Dans ce travail, nous avons évalué la répétabilité et la reproductibilité de l’étude du métabolisme oxydatif du myocarde par imagerie tomographique à positrons avec l’acétate marqué au carbone 11. Méthodes et résultats: Une étude de base et un second examen TEP dynamique à l’ acétate marqué au carbone 11 ont été réalisés (47 ± 22 jours) chez 20 patients présentant une insuffisance cardiaque stable avec une fraction d’éjection réduite. Sans aucune connaissance des données cliniques et au moyen du programme FlowQuant®, deux observateurs ont évalué la répétabilité des TEPs de base et de leur suivi, la reproductibilité intra- et inter-observateur, l’absorption et la clearance du traceur, la mesure de la consommation d’oxygène du myocarde (MVO2), l’efficacité contractile du myocarde (MEE), l’index métabolique du travail myocardique (WMI) et le débit sanguin myocardique (MBF). La reproductibilité et la répétabilité ont été évaluées en utilisant la corrélation intra-classe (ICC) et le coefficient de répétabilité Altman (CR). Les corrélations entre les études de base et leur suivi et la répétabilité des données se sont avérées supérieures pour les paramètres MEE et WMI par rapport à MVO2. Toutes les corrélations intra- et inter-observateurs furent excellentes (ICC = 0,95-0,99). Les valeurs de reproductibilité (CR = 3-6%) furent significativement inférieures aux valeurs de répétabilité (22-54%, p <0.001). La répétabilité des paramètres mesurés s’est avérée supérieure avec un scanner TEP-TDM de nouvelle génération par rapport à l’utilisation de la TEP sans TDM Conclusion: Les mesures réalisées dans cette étude TEP 11C-acétate montre une excellent répétabilité et reproductibilité des paramètres WMI et WMI entre les examens de base et leur suivi effectués par des opérateurs différents. Les nouveaux scanners TEP-TDM devraient être préférés pour le suivi longitudinal de la fonction cardiaque. [Spanish] Spanish Abstract: Antecedentes: el abordaje no invasivo para investigar la eficiencia miocárdica puede ayudar en el seguimiento de la progresión de la insuficiencia cardíaca. Este estudio evalúa la repetibilidad y la reproducibilidad del estudio de metabolismo oxidativo con PET 11C-acetato. Métodos y resultados: Se realizaron estudios de PET 11C-acetato dinámicos al inicio y durante el seguimiento (47 ± 22 días de diferencia) en 20 pacientes con insuficiencia cardíaca estable y fracción de eyección reducida. Dos observadores cegados a los datos clínicos de los pacientes utilizaron FlowQuant® para evaluar la repetibilidad de la prueba-reprueba, así como la reproducibilidad intra e interobservador de la captación de radiotrazador 11C-acetato y sus tasas de eliminación, la medición del consumo miocárdico de oxígeno (MVO2), la eficiencia externa miocardica (EEM), el índice trabajo-metabólico (ITM) y flujo sanguíneo miocárdico (FSM). La reproducibilidad y la repetibilidad se evaluaron mediante la correlación intraclase (ICC) y el coeficiente de repetibilidad (CR) de Bland-Altman. Las correlaciones Prueba-Reprueba y la repetibilidad fueron mejores para la EEM y el ITM en comparación con el MVO2. Todas las correlaciones intra e interobservador fueron excelentes (ICC = 0.95-0.99) y los valores de reproducibilidad (CR = 3-6%) fueron significativamente menores que los valores de repetibilidad prueba-reprueba (22-54%, p <0.001). La repetibilidad fue mejor para todos los parámetros utilizando un equipo PET-TC más nuevo en comparación con un equipo PET sin CT. Conclusión: las mediciones del PET con 11C-acetato del ITM y EEM mostraron una excelente repetibilidad prueba-preprueba y reproducibilidad del operador. Los nuevos equipos PET-CT pueden ser elegidos para el seguimiento longitudinal de la eficiencia miocárdica. [Chinese] Chinese Abstract: 背景: 采用非侵入式方法来研究心肌代谢效率可以帮助追踪心力衰竭的过程。本研究评估利用碳-11 醋酸盐为 PET 显影剂行氧化代谢成像的可重复性和可再现性。 方法和结果: 纳入射血分数减低的 20 名稳定性心衰患者,对患者基线和 47±22 天随访都进行碳-11 醋酸盐 PET 扫描。为测量心肌耗氧量(MVO{sub 2}), 心肌外效率(MEE), 工作代谢指标(WMI)和心肌血流量(MBF), 两名观察者按照双盲的方法利用 FlowQuant®对碳-11 醋酸盐的摄取率和清空率进行了重复性测试以及不同观察者之间的可再现性测试。采用组内相关系数(ICC)和 Bland Altman 可重复性系数(CR)分别对可再现性和可重复性进行评估。MEE 和 WMI 的两次试验系数和可重复性优于MVO{sub 2}。所有观察者之间的相关系数都较好(ICC=0.95-0.99),可再现性系数的值(CR=3-6%)明显低于两次试验可重复性的值(22-54%, P<0.001)。相比于旧的只有 PET 的设备, 采用新型 PET-CT 扫描仪能够使所有参数的可再现性都有所提高。 结论: 碳-11醋酸盐 PET 显像测量 WMI 和 MEE 有很好的可重复性和可再现性。新的 PET-CT 扫描仪可能更适合于心脏代谢效率的长期追踪。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical integration of detector response functions via Monte Carlo simulations

Calculations of detector response functions are complicated because they include the intricacies of signal creation from the detector itself as well as a complex interplay between the detector, the particle-emitting target, and the entire experimental environment. As such, these functions are typically only accessible through time-consuming Monte Carlo simulations. Furthermore, the output of thousands of Monte Carlo simulations can be necessary in order to extract a physics result from a single experiment. Here we describe a method to obtain a full description of the detector response function using Monte Carlo simulations. We also show that a response function calculated in this way can be used to create Monte Carlo simulation output spectra a factor of ~1000× faster than running a new Monte Carlo simulation. A detailed discussion of the proper treatment of uncertainties when using this and other similar methods is provided as well. Here, this method is demonstrated and tested using simulated data from the Chi-Nu experiment, which measures prompt fission neutron spectra at the Los Alamos Neutron Science Center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aqueous Binary Lanthanide(III) Nitrate Ln(NO3)3 Electrolytes Revisited: Extended Pitzer and Bromley Treatments

To date, only limited thermodynamic models describing activity coefficients of the aqueous solutions of lanthanide ions are available. This work expands the existing experimental osmotic coefficient data obtained by classical isopiestic technique for the aqueous binary trivalent lanthanide nitrate Ln(NO3)3 solutions using a combination of water activity and vapor pressure osmometry measurements. The combined osmotic coefficient database for each aqueous lanthanide nitrate at 25°C, consisting of literature available data as well as data obtained in this work, was used to test the validity of Pitzer and Bromley thermodynamic models for the accurate prediction of mean molal activity coefficients of the Ln(NO3)3 solutions in wide concentration ranges. The new and improved Pitzer and Bromley parameters were calculated. It was established that the Ln(NO3)3 activity coefficients in the solutions with ionic strength up to 12 mol kg-1 can be estimated by both Pitzer and single-parameter Bromley models, even though the latter provides for more accurate prediction, particularly in the lower ionic strength regime (up to 6 mol kg-1). On the other hand for the concentrated solutions, the extended three-parameter Bromley model can be employed to predict the Ln(NO3)3 activity coefficients with remarkable accuracy. The accuracy of the extended Bromley model in predicting the activity coefficients was greater than ~95% and ~90% for all solutions with the ionic strength up to 12 mol kg-1 and and 20 mol kg-1, respectively. This is the first time that the activity coefficients for concentrated lanthanide solutions have been predicted with such a remarkable accuracy.

Chatterjee, Sayandev↗

Methodology to assess “no-touch” building audit software using simulated utility data

Building audits are conducted in many commercial buildings to identify opportunities to reduce energy costs and improve building operation. Because audits require significant effort by building engineers, they are usually only affordable for larger commercial buildings. “No-touch” building audit tools have thus been developed to identify potential savings based on a simplified analysis of building energy consumption patterns via high-level energy data such as monthly utility bills. This paper presents a comprehensive and standardized methodology to evaluate the accuracy of no-touch audit tools in detecting and diagnosing building energy problems and quantifying potential energy savings. The test suite is based on output data from a well-characterized set of building energy models, and the methodology is illustrated by applying it to a representative no-touch building audit tool. Results show that the tool estimates building energy end uses with reasonable accuracy but is less accurate in identifying probably causes of high energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bayesian parameter estimation and evaluation of the K -ω shear stress transport model for plane impinging jets

Numerical simulations with semi-empirical turbulence models are commonly used to model impinging jets, often used for cooling solid surfaces. In this work, the constants in the k-ω shear stress transport model in ANSYS FLUENT are calibrated to experimental velocity and heat transfer data for a plane turbulent impinging air jet to determine if Kennedy-O'Hagan calibration (Kennedy and O'Hagan 2001 J. R. Stat. Soc. B 63 425–64) can improve predictions of near-surface velocities and surface Nusselt numbers for similar flows. Impinging jets have been proposed to cool the target plates of the divertor in future magnetic fusion energy reactors, where simulations are used to estimate divertor performance. The flat-plate divertor (Wang et al 2009 Fusion Sci. Technol .56 1023–7) uses a plane jet of helium issuing from a B = 0.5 mm slot to cool a surface with radius of curvature of 44 B at a distance 4 B from the slot. Predictions from the calibrated numerical model are compared with independent experimental data at different flow conditions, as well as surface temperature data for a flat plate divertor test section. The contribution of this work is evaluation of the accuracy of a calibrated turbulence model for modest extrapolations in flow geometry and flow conditions for a plane impinging jet.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

O(6)-symmetry breaking in the {gamma}-soft nucleus {sup 126}Xe and its evolution in the light stable xenon isotopes

Low-lying collective states in {sup 126}Xe have been investigated via the {sup 12}C({sup 126}Xe,{sup 126}Xe{sup *}) projectile Coulomb excitation reaction at 399 MeV. The {gamma} decays were detected with the Gammasphere array. Coulomb excitation cross sections relative to the 2{sub 1}{sup +} state were obtained. Twenty-two absolute E2 transition strengths have been deduced. An sd- interacting boson model (IBM-1) fit agrees well with the new experimental data. This makes a quantitative test of O(6)-symmetry breaking in {sup 126}Xe possible. The measured absolute B(E2) values indicate a preservation of O(5) symmetry, while the O(6) symmetry is broken. The evolution of O(6)-symmetry breaking and of O(5)-symmetry conservation in the {sup 124,126,128}Xe isotopic chain is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High pressure shock tube ignition delay time measurements during oxy-methane combustion with high levels of CO 2 dilution

For this study, ignition delay times and methane species time-histories were measured for methane/O 2 mixtures in a high CO 2 diluted environment using shock tube and laser absorption spectroscopy. The experiments were performed between 1300 K and 2000 K at pressures between 6 and 31 atm. The test mixtures were at an equivalence ratio of 1 with CH 4 mole fractions ranging from 3.5% -5% and up to 85% CO 2 with a bath of argon gas as necessary. The ignition delay times and methane time histories were measured using pressure, emission, and laser diagnostics. Predictive ability of two literature kinetic mechanisms (GRI 3.0 and ARAMCO Mech 1.3) was tested against current data. In general, both mechanisms performed reasonably well against measured ignition delay time data. The methane time-histories showed good agreement with the mechanisms for most of the conditions measured. A correlation for ignition delay time was created taking into the different parameters showing that the ignition activation energy for the fuel to be 49.64 kcal/mol. Through a sensitivity analysis, CO 2 is shown to slow the overall reaction rate and increase the ignition delay time. To the best of our knowledge, we present the first shock tube data during ignition of methane/CO 2 /O 2 under these conditions. In conclusion, current data provides crucial validation data needed for development of future kinetic mechanisms.

42 ENGINEERING↗