Development of the dry tape battery concept
High energy anode and cathode for dry tape battery - incapsulation of electrolyte - manufacturing and testing of device
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
High energy anode and cathode for dry tape battery - incapsulation of electrolyte - manufacturing and testing of device
High capacity nonaqueous secondary battery - synthesis and electrochemical studies of dialkyl and diary beryllium compounds, organoberyllium complex salts, and other complex salt solutions
The NASA Lewis Research Center has contracted with Electro Energy, Inc., to develop a bipolar nickel-metal hydride battery design for energy storage on low-Earth-orbit satellites. The objective of the bipolar nickel-metal hydride battery development program is to approach advanced battery development from a systems level while incorporating technology advances from the lightweight nickel electrode field, hydride development, and design developments from nickel-hydrogen systems. This will result in a low-volume, simplified, less-expensive battery system that is ideal for small spacecraft applications. The goals of the program are to develop a 1-kilowatt, 28-volt (V), bipolar nickel-metal hydride battery with a specific energy of 100 watt-hours per kilogram (W-hr/kg), an energy density of 250 W-hr/liter and a 5-year life in low Earth orbit at 40-percent depth-of-discharge.
Nonlinear viscoelastic model calibrations are developed for two filled epoxies: an adduct of Epon 828 DGEBA and CTBN cross-linked with diethanolamine (DEA) filled with glass microballoons, called 828-CTBN/DEA/GMB, and Epon 828 DGEBA cross-linked with Ancamine Z and filled with alumina, called 828/Z/AlOx. The thermo-mechanical responses of these materials are represented using the SPECtacular constitutive model, an extension of the Simplified Potential Energy Clock (SPEC) model. The model couples
In the previous lecture, the issues related to arcjet flow modeling were introduced, and the limitations of conventional instrumentation in addressing these issues were discussed. The general level of understanding of the arcjet flows was seen to preclude the use of arcjets as aerothermodynamic test facilities beyond the current role in aerothermal material testing, despite their long test duration capability. In this section, the focus will be on new developments in spectroscopic instrumentation and techniques that can be brought to bear on the fundamental problem of arcjet stream characterization. Although a wide selection of arcjet facilities were introduced in the previous section, the discussion of nonintrusive diagnostic instrumentation will be restricted to the large-scale, segmented, constricted-arc heater facilities that are most widely used in thermal protection material testing for aerospace applications. After a brief review of the important features of arcjet flows, the topic of nonintrusive, optical diagnostics is introduced with a discussion of some of the basic aspects of radiative transitions. The lecture is then organized into two sections covering emission measurements and laser-induced fluorescence measurements. Emission measurements are presented next for different regions of arcjet flows, while the fluorescence measurements are presented for the free stream region only. Summaries are given for each of the two main sections, and observations on arcjet characterization by optical diagnostics in general are given at the end.
Here, we develop a quantitative theory of phonon magnetic moment in doped Dirac semimetals. Our theory is based on an emergent gauge field approach to the electron-phonon coupling, applicable to gapless systems. We find that the magnetic moment is directly proportional to the electrical Hall conductivity through the phonon Hall viscosity. Our theory is combined with the first-principles calculations, allowing us to quantitatively implement it to realistic materials. Magnetic moments are found to be of the order of a Bohr magneton for Raman-active phonon modes in graphene and Cd 3 As 2 . Our results provide practical guidance for the dynamical generation of large magnetization in quantum materials.
The use of quantum light to probe exciton properties in semiconductor and molecular nanostructures typically occurs in the low-intensity regime. A substantial enhancement of exciton-photon coupling can be achieved with photonic cavities, where excitons hybridize with cavity modes to form polariton states. Here, to provide a theoretical framework for interpreting emerging experimental efforts in this direction, we develop a scattering theory describing the interaction of frequency-entangled photon pairs with cavity polariton and bipolariton states under various coupling regimes. Employing the Tavis-Cummings model in combination with our scattering approach, we present a quantitative analysis of how the interaction of the entangled photon pair with the polariton or bipolariton modifies its joint spectral amplitude (JSA). Specifically, we examine the effects of the cavity-mode steady-state population, exciton-cavity coupling strength, and different forms of the input photon JSA. Our results show that the entanglement entropy of the scattered photons is highly sensitive to the interplay between the input JSA and the spectral line shapes of the polariton resonances, emphasizing the cavity filtering effects. We suggest that biphoton-scattering quantum light spectroscopy best serves as a sensitive probe of polariton and bipolariton states in the photon-vacuum cavity state. Our approach is not only robust to various regimes of cavity-exciton coupling, but also amenable to extensions beyond the Tavis-Cummings model, enabling the representation of a broad class of molecular systems and solid state quantum materials.
High energy density primary battery development - electrochemical half-cell screening of anode- electrolyte combinations, cell discharge, and potential studies
Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.
The state-of-the-art Oxygen Generation Assembly (OGA) has been reliably producing breathing oxygen for the crew aboard the International Space Station (ISS) for over eight years. Lessons learned from operating the ISS OGA have led to proposing incremental improvements to advance the baseline design for use in a future long duration mission. These improvements are intended to reduce system weight, crew maintenance time and resupply mass from Earth while increasing reliability. The proposed improvements include replacing the cell stack membrane material, deleting the nitrogen purge equipment, replacing the hydrogen sensors, deleting the wastewater interface, replacing the hydrogen dome and redesigning the cell stack power supply. The development work to date will be discussed and forward work will be outlined. Additionally, a redesigned system architecture will be proposed.
We report on progress on the STABLE study, which was awarded on the NASA 2023 ROSES D.19 opportunity. In the study, we are developing technologies for the Habitable Worlds Observatory (HWO) in four areas: Micrometeoroid Impact Mitigation, Telescope Temperature Control, Ultra-Stable Telescope Structure Materials and Modeling, and Improvement of Thermal Expansion Test Capability. This study is a collaboration between Northrop Grumman, Kratos, NeXolve, JPL, STScI, NASA’s White Sands Test Facility, and NASA Goddard’s Ultra-Stable Test Facility. We will also discuss our plans for our follow-on study as part of NASA’s 2024 ROSES D.19. In this study, we will address additional technologies as well as perform analysis of HWO architecture options.
Polyphenylene oxide case and cover mechanical properties determination, and component reliability tests for silver-zinc battery with inorganic separators
Explore the source record for details and available documents.
An overview of spacecraft power system design trends, focusing on higher power bus voltages and improved energy storage systems, is followed by a discussion of bipolar Ni/H2 battery development efforts. Several 10-cell batteries and one 50-cell battery are described, and performance results are presented. A comparison of individual-pressure-vessel and bipolar Ni/H2 technologies is used to suggest a new direction for bipolar Ni/H2 battery development efforts, toward a large number of passively cooled cells in parallel.
Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.
Explore the source record for details and available documents.
Lithium anodes, inorganic and organic cathodes, vacuum-distilled solvents, and methods for sintering cupric fluoride on lightweight metal substrates - development of high energy battery
High energy density primary battery - film formation on cupric fluoride cathodes discharged in organic electrolytes