Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Electrical Impact of SiC Structural Crystal Defects on High Electric Field Devices

Commercial epilayers are known to contain a variety of crystallographic imperfections. including micropipes, closed core screw dislocations. low-angle boundaries, basal plane dislocations, heteropolytypic inclusions, and non-ideal surface features like step bunching and pits. This paper reviews the limited present understanding of the operational impact of various crystal defects on SiC electrical devices. Aside from micropipes and triangular inclusions whose densities have been shrinking towards manageably small values in recent years, many of these defects appear to have little adverse operational and/or yield impact on SiC-based sensors, high-frequency RF, and signal conditioning electronics. However high-power switching devices used in power management and distribution circuits have historically (in silicon experience) demanded the highest material quality for prolonged safe operation, and are thus more susceptible to operational reliability problems that arise from electrical property nonuniformities likely to occur at extended crystal defects. A particular emphasis is placed on the impact of closed-core screw dislocations on high-power switching devices, because these difficult to observe defects are present in densities of thousands per cm,in commercial SiC epilayers. and their reduction to acceptable levels seems the most problematic at the present time.

Neudeck, Philip G.↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT

Purpose: Compressed sensing theory has enabled an accurate, low-dose cone-beam computed tomography (CBCT) reconstruction using a minimal number of noisy projections. However, the reconstruction time remains a significant challenge for practical implementation in the clinic. In this work, we propose a novel gradient projection algorithm, based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB), that handles the total variation (TV)-norm regularization-based least squares problem for the CBCT reconstruction in a highly efficient manner, with speed acceptable for routine use in the clinic. Methods: CBCT is reconstructed by minimizing an energy function consisting of a data fidelity term and a TV-norm regularization term. Both terms are simultaneously minimized by calculating the gradient projection of the energy function with the step size determined using an approximate Hessian calculation at each iteration, based on the Barzilai-Borwein formulation. To speed up the process, a multiresolution optimization is used. In addition, the entire algorithm was designed to run with a single graphics processing unit (GPU) card. To evaluate the performance, the Shepp-Logan numerical phantom, the CatPhan 600 physical phantom, and a clinically-treated head-and-neck patient were acquired from the TrueBeam system (Varian Medical Systems, Palo Alto, CA). For each scan, in total, 364 projections were acquired in a 200 deg. rotation. The imager has 1024 x 768 pixels with 0.388 x 0.388-mm resolution. This was down-sampled to 512 x 384 pixels with 0.776 x 0.776-mm resolution for reconstruction. Evenly spaced angles were subsampled and used for varying the number of projections for the image reconstruction. To assess the performance of our GP-BB algorithm, we have implemented and compared with three compressed sensing-type algorithms, the two of which are popular and published (forward-backward splitting techniques), and the other one with a basic line-search technique. In addition, the conventional Feldkamp-Davis-Kress (FDK) reconstruction of the clinical patient data is compared as well. Results: In comparison with the other compressed sensing-type algorithms, our algorithm showed convergence in {<=}30 iterations whereas other published algorithms need at least 50 iterations in order to reconstruct the Shepp-Logan phantom image. With the CatPhan phantom, the GP-BB algorithm achieved a clinically-reasonable image with 40 projections in 12 iterations, in less than 12.6 s. This is at least an order of magnitude faster in reconstruction time compared with the most recent reports utilizing GPU technology given the same input projections. For the head-and-neck clinical scan, clinically-reasonable images were obtained from 120 projections in 34-78 s converging in 12-30 iterations. In this reconstruction range (i.e., 120 projections) the image quality is visually similar to or better than the conventional FDK reconstructed images using 364 projections. This represents a dose reduction of nearly 67% (120/364 projections) while maintaining a reasonable speed in clinical implementation. Conclusions: In this paper, we proposed a novel, fast, low-dose CBCT reconstruction algorithm using the Barzilai-Borwein step-size calculation. A clinically viable head-and-neck image can be obtained within {approx}34-78 s while simultaneously cutting the dose by approximately 67%. This makes our GP-BB algorithm potentially useful in an on-line image-guided radiation therapy (IGRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reflectance Modeling

The main thrust of the work conducted is in the modeling of spectral responses of discontinuous conifer forest canopies, considered as collections of conical forms that are illuminated at an angle and cast shadows on contracting background. The three first-year objectives are: (1) modification of the variance-driven model to incorporate overlapping of shadows and crowns; (2) collection and analysis of photographic data to calibrate tree-spacing functions; and (3) collection of field data to determine height, spacing, and shape of conifers in open and closed stands in the Goosenest (California) test area. Modification of the invertible model uses a linear approximation to correct for the reduction in shadow and canopy area that occurs when shadows fall on crowns or tree crowns intersect. Comparison of the results of the approximation with a series of Monte Carlo simulations shows that the mean area covered by crowns or shadows is approximated quite accurately, but the variance calculated departs significantly from simulated values. The analysis of tree spacing patterns using air photos showed that spacing tended to be somewhat regular at a scale approximately equal to the average distance between trees, but at larger distance scales counts of trees in cells could be approximated acceptably by a Poisson (random) function.

Strahler, A. H.↗

Optical system storage design with diffractive optical elements

Optical data storage systems are gaining widespread acceptance due to their high areal density and the ability to remove the high capacity hard disk from the system. In magneto-optical read-write systems, a small rotation of the polarization state in the return signal from the MO media is the signal which must be sensed. A typical arrangement used for detecting these signals and correcting for errors in tracking and focusing on the disk is illustrated. The components required to achieve these functions are listed. The assembly and alignment of this complex system has a direct impact on cost, and also affects the size, weight, and corresponding data access rates. As a result, integrating these optical components and improving packaging techniques is an active area of research and development. Most designs of binary optic elements have been concerned with optimizing grating efficiency. However, rigorous coupled wave models for vector field diffraction from grating surfaces can be extended to determine the phase and polarization state of the diffracted field, and the design of polarization components. A typical grating geometry and the phase and polarization angles associated with the incident and diffracted fields are shown. In our current stage of work, we are examining system configurations which cascade several polarization functions on a single substrate. In this design, the beam returning from the MO disk illuminates a cascaded grating element which first couples light into the substrate, then introduces a quarter wave retardation, then a polarization rotation, and finally separates s- and p-polarized fields through a polarization beam splitter. The input coupler and polarization beam splitter are formed in volume gratings, and the two intermediate elements are zero-order elements.

Kostuk, Raymond K.↗

The effects of vortex modeling on blade-vortex interaction noise prediction

The use of a blade vortex interaction noise prediction scheme, based on CAMRAD/JA, FPR and RAPP, quantifies the effects of errors and assumptions in the modeling of the helicopter's shed vortex on the acoustic predictions. CAMRAD/JA computes the wake geometry and inflow angles that are used in FPR to solve for the aerodynamic surface pressures. RAPP uses these surface pressures to predict the acoustic pressure. Both CAMRAD/JA and FPR utilize the Biot-Savart Law to determine the influence of the vortical velocities on the blade loading and both codes use an algebraic vortex model for the solid body rotation of the vortex core. Large changes in the specification of the vortex core size do not change the inplane wake geometry calculated by CAMRAD/JA and only slightly affect the out-of-plane wake geometry. However, the aerodynamic surface pressure calculated by FPR changes in both magnitude and character with small changes to the core size used by the FPR calculations. This in turn affects the acoustic predictions. Shifting the CAMRAD/JA wake geometry away from the rotor plane by 1/4 chord produces drastic changes in the acoustic predictions indicating that the prediction of acoustic pressure is extremely sensitive to the miss distance between the vortex and the blade and that this distance must be calculated as accurately as possible for acceptable noise predictions. The inclusion or exclusion of a vortex in the FPR-RAPP calculation allows for the determination of the relative importance of that vortex as a BVI noise source.

Gallman, Judith M.↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The effects of pressure sensor acoustics on airdata derived from a High-angle-of-attack Flush Airdata Sensing (HI-FADS) system

The accuracy of a nonintrusive high angle-of-attack flush airdata sensing (HI-FADS) system was verified for quasi-steady flight conditions up to 55 deg angle of attack during the F-18 High Alpha Research Vehicle (HARV) Program. The system is a matrix of nine pressure ports arranged in annular rings on the aircraft nose. The complete airdata set is estimated using nonlinear regression. Satisfactory frequency response was verified to the system Nyquist frequency (12.5 Hz). The effects of acoustical distortions within the individual pressure sensors of the nonintrusive pressure matrix on overall system performance are addressed. To quantify these effects, a frequency-response model describing the dynamics of acoustical distortion is developed and simple design criteria are derived. The model adjusts measured HI-FADS pressure data for the acoustical distortion and quantifies the effects of internal sensor geometries on system performance. Analysis results indicate that sensor frequency response characteristics very greatly with altitude, thus it is difficult to select satisfactory sensor geometry for all altitudes. The solution used presample filtering to eliminate resonance effects, and short pneumatic tubing sections to reduce lag effects. Without presample signal conditioning the system designer must use the pneumatic transmission line to attenuate the resonances and accept the resulting altitude variability.

Whitmore, Stephen A.↗

A High-Efficiency, Low Cost, High-Temperature Nanocomposite Soft Magnetic Materials for Vehicle Power Electronics.

The charge components for each gas atomization experiment (GA-1-230, GA-1-232, and GA-1-238) was provided by Aegis and consisted of elemental materials, while MPC provided the master alloy arc melted button castings that were added to yield a charge composition of (Co35Fe65)88Zr7B4Cu. The atmosphere in the melting chamber and connected atomization system was evacuated with a mechanical pump prior to backfilling with ultrahigh purity (UHP grade) Ar. The melt was contained in a bottom tapped zirconia crucible with an alumina stopper rod to seal the exit while heating to a pouring temperature of 1550 – 1575oC. When the desired superheat was reached, the stopper rod was lifted and melt flowed through a yttria stabilized zirconia (YSZ) pour tube with a 3.2 mm orifice and was atomized with Ar from a 45-22-052-409 gas atomization nozzle (or atomization die), having a jet apex angle of 45 degrees with 22 cylindrical gas jets (each with diameter of 1.32 mm or 0.052 inches) arrayed around the axis of a 10.4 mm central bore. The Ar atomization gas supply regulator pressure was set to produce nozzle manifold pressures for the series of runs at a pressure of 450 psi. Secondary gas halos of Ar and He also were added to the interior of the spray chamber at various downstream locations for additional cooling of the atomized droplets and to prevent coalescence of the resulting powder. Powder size analysis and size classification were performed with a full set of ASTM sieves, starting with the 106 µm screen and proceeding down through the 20 µm screen. A Microtrac particle size analyzer was used to verify the size classification results of the particulate resulting from the runs. The resulting powder size distribution results are provided with this report labeled with their respective run numbers (GA-1-230, GA-1-232, and GA-1-238). It should be noted that the size distribution results of the first atomization run were quite acceptable and the same parameters were used for the second and third runs to test the reproducibility for technology transfer purposes.

33 ADVANCED PROPULSION SYSTEMS↗

MASS AND RADIUS DETERMINATIONS FOR FIVE TRANSITING M-DWARF STARS

We have derived masses and radii for both components in five short-period single-lined eclipsing binary stars discovered by the TrES wide-angle photometric survey for transiting planets. All these systems consist of a visible F-star primary and an unseen M-star secondary (M {sub A} {>=} 0.8 M {sub sun}, M {sub B} {<=} 0.45 M {sub sun}). The spectroscopic orbital solution combined with a high-precision transit light curve for each system gives sufficient information to calculate the density of the primary star and the surface gravity of the secondary. The masses of the primary stars were obtained using stellar evolution models, which requires accurate determinations of metallicities and effective temperatures. In our case, the uncertainty in the metallicity of the primary stars is the most important limiting factor in order to obtain accurate results for the masses and radii of the unseen M-dwarf secondaries. The solutions were compared with results obtained by calculating the radius of the primary stars under the assumption of rotational synchronization with the orbital period and alignment between their spin axis and the axis of the orbit, using the observed broadening of the spectral lines as an indicator of stellar rotation. Four systems show an acceptable match between the two sets of results when their metallicity is allowed to vary around solar values (-0.5 {<=} [Fe/H] {<=} +0.5), but one system shows a clear mismatch between the two solutions, which may indicate the absence of synchronization or a misalignment between the rotational and orbital axis. When compared to low-mass stellar evolution models, the derived masses and radii of the unseen M dwarfs are inconsistent (three only marginally) with the predicted values, with all of the radii being larger than expected for their masses. These results confirm the discrepancy shown in a previous work between the predicted and observed radii on low-mass binary stars. This work also shows that reliance on the assumption of synchronization to derive the mass and radius of stars in eclipsing single-lined F+M binaries is a useful tool, but may not always be warranted and should be carefully tested against stellar evolution models.

99 GENERAL AND MISCELLANEOUS↗

SU-F-T-85: Energy Modulated Electron Postmastectomy Unreconstructed (PU) Chest Wall (CW) Irradiation Technique to Achieve Heart Sparing

Purpose: For left-sided PU patients requiring CW and nodal irradiation, sometimes partial wide tangents (PWT) are not feasible due to abnormal chest wall contour or heart position close to the anterior chest wall or unusual wide excision scar. We developed an energy modulated electron chest wall irradiation technique that will achieve heart sparing. Methods: Ten left-sided PU patients were selected for this dosimetry study. If PWT were used, the amount of the ipsilateral lung would be ranged 3.4 to 4.4 cm, and the amount of heart would be ranged 1.3 to 3.8 cm. We used electron paired fields that matched on the skin to achieve dose conformity to the chest wall. The enface electron fields were designed at extended SSD from a single isocenter and gantry angle with different energy beams using different cutout. Lower energy was used in the central chest wall part and higher energy was used in the periphery of the chest wall. Bolus was used for the electron fields to ensure adequate skin dose coverage. The electron fields were matched to the photon supra-clavicle field in the superior region. Daily field junctions were used to feather the match lines between all the fields. Target volumes and normal tissues were drawn according to institutional protocols. Prescription dose was 2Gy per fraction for a total 50Gy. Dose calculations were done with Eclipse EMC-11031 for Electron and AAA-11031 for photons. Results: Six patients were planned using 6/9MeV, three using 9/12MeV and one 6/12MeV. Target volumes achieved adequate coverage. For heart, V30Gy, V20Gy and Mean Dose were 0.6%±0.6%, 2.7%±1.7%, and 3.0Gy±0.8Gy respectively. For ipsilateral lung, V50Gy, V20Gy, V10Gy and V5Gy were 0.9%±1.1%, 34.3%±5.1%, 51.6%±6.3% and 64.1%±7.5% respectively. Conclusion: For left-sided PU patients with unusual anatomy, energy modulated electron CW irradiation technique can achieve heart sparing with acceptable lung dose.

60 APPLIED LIFE SCIENCES↗

Shielding Design of Gantry 3 - Paper 104

The proton therapy complex at PSI will be extended with a third irradiation facility, Gantry 3. This new Gantry is being built in the south-west area of the experimental hall of the High Intensity Proton Accelerator (HIPA) complex at PSI. Originally, it was planned to restrict the operation of Gantry 3 to 180 deg. by hardware means, but due to new considerations, the Gantry will be able to be moved in the full 360 deg. field. This change requires the redesign and reinforcement of the too weak shielding in the north and east directions. Additionally, the isocenter has been fixed, thus allowing for the exact calculation of distances, angles and effective shielding thicknesses in order to determine the dose rates more accurately. For these calculations a fast and simple semi-empirical analytical formula and the more time consuming, but also more sophisticated best estimate code MCNPX 2.7.0 have been used. The two methods used for the calculations of the dose rates are in good agreement. Generally, the analytical method provides the results instantaneously, but predicts higher dose rate values of a factor 2-3 larger than the Monte-Carlo particle transport code MCNPX. Thus, MCNPX should be used to verify the final design of the shielding, including additional details in the simulation model (e.g. ventilation shafts) which have weakening effect on the shielding. Such influences are hard to quantify analytically. The analytical method fails when the geometry becomes complex, i.e. when it is difficult to determine the effective length of the shielding; in the case of position 10 the shielding effect of the inner wall is difficult to quantify. Due to the change of the specification of the Gantry, the shielding was reinforced at the north and east sides, and the HC-layer was extended in front of the control room. The dose rates are acceptable with the new shielding layout. A detailed dose rate mapping is planned in the commissioning phase of Gantry 3 to verify the simulation results and to identify any remaining weak spots of the shielding. (authors)

43 PARTICLE ACCELERATORS↗

SU-E-T-568: Neutron Dose Survey of a Compact Single Room Proton Machine

Purpose: To ensure acceptable radiation limits are maintained for those working at and near the machine during its operation, a comprehensive radiation survey was performed prior to the clinical release of Mevion S250 compact proton machine at Stephenson Oklahoma Cancer Center. Methods: The Mevion S250 proton therapy system consists of the following: a superconducting cyclotron to accelerate the proton particles, a passive double scattering system for beam shaping, and paired orthogonal x-ray imaging systems for patient setup and verification via a 6D robotic couch. All equipment is housed within a single vault of compact design. Two beam delivery applicators are available for patient treatment, offering field sizes of as great as 14 cm and 25 cm in diameter, respectively. Typical clinical dose rates are between 1 and 2 Gy/min with a fixed beam energy of 250 MeV. The large applicator (25 cm in diameter) was used in conjunction with a custom cut brass aperture to create a 20 cm x 20 cm field size at beam isocenter. A 30 cm − 30 cm − 35 cm high density plastic phantom was placed in the beam path to mimic the conditions creating patient scatter. Measurements integrated-ambient-neutron-dose-equivalence were made with a SWENDII detector. Gantry angles of 0, 90 and 180 degrees, with a maximum dose rate of 150 MU/min (for large applicator) and beam configuration of option 1 (range 25 cm and 20 cm modulation), were selected as testing conditions. At each point of interest, the highest reading was recorded at 30 cm from the barrier surface. Results: The highest neutron dose was estimated to be 0.085 mSv/year at the console area. Conclusion: All controlled areas are under 5 mSv/year and the uncontrolled areas are under 1 mSv/year. The radiation protection provided by the proton vault is of sufficient quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurements of differential two-particle number and transverse momentum correlation functions in pp collisions at $\sqrt{\textit{s}}$ = 13 TeV

Differential two-particle normalized cumulants (R 2 ) and transverse momentum correlations (P 2 ) are measured as a function of the relative pseudorapidity and azimuthal angle difference (Δη, Δφ) of charged particle pairs in minimum bias pp collisions at $\sqrt{s}$ = 13 TeV. The measurements use charged hadrons in the pseudorapidity region of |η| < 0.8 and the transverse momentum range 0.2 < p T < 2.0 in order to focus on soft multiparticle interactions and to complement prior measurements of these correlation functions in p–Pb and Pb–Pb collisions. The correlation functions are reported for both unlike-sign and like-sign pairs and their charge-independent and charge-dependent combinations. Both the R 2 and P 2 measured in pp collisions exhibit features qualitatively similar to those observed in p–Pb and Pb–Pb collisions. The Δη and Δφ root mean square widths of the near-side peak of the correlation functions are evaluated and compared with those observed in p–Pb and Pb–Pb collisions and show smooth evolution with the multiplicity of charged particles produced in the collision. The comparison of the measured correlation functions with predictions from PYTHIA8 shows that this model qualitatively captures their basic structure and characteristics but feature important differences. In addition, the R$^{CD}_{2}$ is used to determine the charge balance function of hadrons produced within the detector acceptance of the measurements. The integral of the balance function is found to be compatible with those reported by a previous measurement in Pb–Pb collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Controls-structures-interaction dynamics during RCS control of the Orbiter/SRMS/SSF configuration

During the assembly flights of the Space Station Freedom (SSF), the Orbiter will either dock with the SSF and retract to the final berthed position, or will grapple the SSF using the Shuttle Remote Manipulator System (SRMS) and maneuver the SRMS coupled vehicles to their final berthed position. The SRMS method is expected to take approximately one to one and a half hours to complete and require periodic attitude corrections by either the Orbiter or the SSF reaction control system (RCS) or continuous control by a control moment gyro (CMG) system with RCS desaturation as required. Free drift of the attached vehicles is not currently thought to be acceptable because the desired system attitude will quickly deteriorate due to unbalanced gravity gradient and aerodynamic torques resulting in power generation problems, thermodynamic control problems, and communications problems. This paper deals with the simulation and control of the SRMS during trunnion/latch interaction dynamics and during RCS maneuvers. The SRMS servo drive joints have highly non-linear elastic characteristics which tend to degrade sensitive control strategies. In addition the system natural frequencies are extremely low and depend on the drive joint deflections and SRMS geometric position. The lowest mean period of oscillation for the Orbiter/SRMS/SSF(MB6) system in brakes hold mode positioned near the final berthed position is approximately 120 seconds. A detailed finite element model of the SRMS has been developed and used in a newly developed SRMS systems dynamics simulation to investigate the non-linear transient response dynamics of the Orbiter/SRMS/SSF systems. The present SRMS control strategy of brakes only recommended by the Charles Draper Labs is contrasted with a robust controller developed by the authors. The robust controller uses an optimal inear quadratic regulator (LQR) to optimally place the closed-loop poles of a multivariable continuous-time system within the common region of an open sector with the sector angle plus or minus 45 degrees from the negative real axis, and the left-hand side of a parallel to the imaginary axis in the complex s-plane. This guarantees that the critical damping ratio for the desired control modes is equal to or in excess of 0.707. The matrix sign function is used for solving the Riccati equations which appear in the controller design procedure. Fast and stable algorithms have recently been developed for the computation of the matrix sign function. Simulation results are given which demonstrate the potential CSI involvement for the current SRMS control system and the proposed control system.

Schliesing, J. A.↗

System size dependence of cluster properties from two-particle angular correlations in Cu+Cu and Au+Au collisions at sq root(s{sub NN})=200 GeV

We present results on two-particle angular correlations in Cu+Cu and Au+Au collisions at a center-of-mass energy per nucleon pair of 200 GeV over a broad range of pseudorapidity (eta) and azimuthal angle (phi) values as a function of collision centrality. The PHOBOS detector at the Relativistic Heavy Ion Collider has a uniquely large angular coverage for inclusive charged particles, which allows for the study of correlations on both long- and short-range scales. A complex two-dimensional correlation structure in {Delta}{eta} and {Delta}{phi} emerges, which is interpreted in the context of a cluster model. The effective cluster size and decay width are extracted from the two-particle pseudorapidity correlation functions. The effective cluster size found in semicentral Cu+Cu and Au+Au collisions is comparable to that found in proton-proton collisions but a nontrivial decrease in size with increasing centrality is observed. Moreover, a comparison of results from Cu+Cu versus Au+Au collisions shows an interesting scaling of the effective cluster size with the measured fraction of total cross section (which is related to the ratio of the impact parameter to the nuclear radius, b/2R), suggesting a geometric origin. Further analysis for pairs from restricted azimuthal regions shows that the effective cluster size at {Delta}{phi}{approx}180 deg. drops more rapidly toward central collisions than the size at {Delta}{phi}{approx}0 deg. The effect of limited {eta} acceptance on the cluster parameters is also addressed, and a correction is applied to present cluster parameters for full {eta} coverage, leading to much larger effective cluster sizes and widths than previously noted in the literature. These results should provide insight into the hot and dense medium created in heavy ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prostate intrafraction motion evaluation using kV fluoroscopy during treatment delivery: A feasibility and accuracy study

Margin reduction for prostate radiotherapy is limited by uncertainty in prostate localization during treatment. We investigated the feasibility and accuracy of measuring prostate intrafraction motion using kV fluoroscopy performed simultaneously with radiotherapy. Three gold coils used for target localization were implanted into the patient's prostate gland before undergoing hypofractionated online image-guided step-and-shoot intensity modulated radiation therapy (IMRT) on an Elekta Synergy linear accelerator. At each fraction, the patient was aligned using a cone-beam computed tomography (CBCT), after which the IMRT treatment delivery and fluoroscopy were performed simultaneously. In addition, a post-treatment CBCT was acquired with the patient still on the table. To measure the intrafraction motion, we developed an algorithm to register the fluoroscopy images to a reference image derived from the post-treatment CBCT, and we estimated coil motion in three-dimensional (3D) space by combining information from registrations at different gantry angles. We also detected the MV beam turning on and off using MV scatter incident in the same fluoroscopy images, and used this information to synchronize our intrafraction evaluation with the treatment delivery. In addition, we assessed the following: the method to synchronize with treatment delivery, the dose from kV imaging, the accuracy of the localization, and the error propagated into the 3D localization from motion between fluoroscopy acquisitions. With 0.16 mAs/frame and a bowtie filter implemented, the coils could be localized with the gantry at both 0 deg. and 270 deg. with the MV beam off, and at 270 deg. with the MV beam on when multiple fluoroscopy frames were averaged. The localization in two-dimensions for phantom and patient measurements was performed with submillimeter accuracy. After backprojection into 3D the patient localization error was (-0.04{+-}0.30) mm, (0.09{+-}0.36) mm, and (0.03{+-}0.68) mm in the right-left (RL), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. Simulations showed that while oscillating (stationary) motion cannot be effectively represented in 3D, linearly drifting (nonstationary) motion is detectable with good accuracy. These results show that measuring prostate intrafraction motion using a single kV imager during radiotherapy is feasible and can be performed with acceptable accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tolerance Factor for Stabilizing 3D Hybrid Halide Perovskitoids Using Linear Diammonium Cations

Three-dimensional (3D) halide perovskites have attracted enormous research interest, but the choice of the A-site cations is limited by the Goldschmidt tolerance factor. In order to accommodate cations that lie outside the acceptable range of the tolerance factor, low-dimensional structures usually form. To maintain the favorable 3D connection, the links among the metal-halide octahedra need to be rearranged to fit the large cations. This can result in a departure from the proper corner-sharing perovskite architectures and lead to distinctly different perovskitoid motifs with edge- and face-sharing. In this work, we report four new 3D bromide perovskitoids incorporating linear organic diammonium cations, A'Pb 2 Br 6 (A' is a +2 cation). We propose a rule that can guide the further expansion of this class of compounds, analogous to the notion of Goldschmidt tolerance factor widely adopted for 3D AMX 3 perovskites. The fundamental building blocks in A'Pb 2 Br 6 consist of two edge-shared octahedra, which are then connected by corner-sharing to form a 3D network. Different compounds adopt different structural motifs, which can be transformed from one to another by symmetry operations. Electronic structure calculations suggest that they are direct bandgap semiconductors, with relatively large band dispersions created by octahedra connected by corner-sharing. They exhibit similar electronic band structures and dynamic lattice characteristics to the regular 3D AMX 3 perovskites. Structures with smaller Pb–Br–Pb angles and larger octahedra distortion exhibit broad photoluminescence at room temperature. Furthermore, the emerging structure–property relationships in these 3D perovskitoids set the foundation for designing and investigating these compounds for a variety of optoelectronic applications.

36 MATERIALS SCIENCE↗