Search NASA⌕ Search

SEARCH · Search NASA

Results for “active source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Neutron Capture Gamma-Ray Libraries for Nuclear Applications

The neutron capture reaction is useful in identifying and analyzing the gamma-ray spectrum from an unknown assembly as it gives unambiguous information on its composition. This can be done passively or actively where an external neutron source is used to probe an unknown assembly. There are known capture gamma-ray data gaps in the ENDF libraries used by transport codes for various nuclear applications. The Evaluated Gamma-ray Activation file (EGAF) is a new thermal neutron capture database of discrete line spectra and cross sections for over 260 isotopes that was developed as part of an IAEA Coordinated Research Project. EGAF is being used to improve the capture gamma production in ENDF libraries. For medium to heavy nuclei the quasi continuum contribution to the gamma cascades is not experimentally resolved. The continuum contains up to 90% of all the decay energy and is modeled here with the statistical nuclear structure code DICEBOX. This code also provides a consistency check of the level scheme nuclear structure evaluation. The calculated continuum is of sufficient accuracy to include in the ENDF libraries. This analysis also determines new total thermal capture cross sections and provides an improved RIPL database. For higher energy neutron capture there is less experimental data available making benchmarking of the modeling codes more difficult. We are investigating the capture spectra from higher energy neutrons experimentally using surrogate reactions and modeling this with Hauser-Feshbach codes. This can then be used to benchmark CASINO, a version of DICEBOX modified for neutron capture at higher energy. This can be used to simulate spectra from neutron capture at incident neutron energies up to 20 MeV to improve the gamma-ray spectrum in neutron data libraries used for transport modeling of unknown assemblies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Complete Census of Hα Emitters in NGC 6397

We used a data set of archival Hubble Space Telescope images obtained through the F555W, F814W, and F656N filters to perform a complete search for objects showing Hα emission in the globular cluster NGC 6397. As a photometric diagnostic, we used the (V−Hα){sub 0} color excess in the (V−Hα){sub 0}–(V−I){sub 0} color–color diagram. In the analyzed field of view, we identified 53 Hα emitters. In particular, we confirmed the optical counterpart to 20 X-ray sources (7 cataclysmic variables, 2 millisecond pulsars and 11 active binaries) and identified 33 previously unknown sources, thus significantly enlarging the population of known active binaries in this cluster. We report the main characteristics for each class of objects. Photometric estimates of the equivalent width of the Hα emission line were derived from the (V−Hα){sub 0}-excess and, for the first time, compared to the spectroscopic measurements obtained from the analysis of MUSE spectra. The very good agreement between the spectroscopic and photometric measures fully confirmed the reliability of the proposed approach to measure the Hα emission. The search demonstrated the efficiency of this novel approach to pinpoint and measure Hα-emitters, thus offering a powerful tool to conduct a complete census of objects with formations and evolutions that can be strongly affected by dynamical interactions in star clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comet Active Beyond the Crystallization Zone

We present observations showing inbound long-period comet C/2017 K2 (PANSTARRS) to be active at a record heliocentric distance. Nucleus temperatures are too low (60–70 K) either for water ice to sublimate or for amorphous ice to crystallize, requiring another source for the observed activity. Using the Hubble Space Telescope we find a sharply bounded, circularly symmetric dust coma 10{sup 5} km in radius, with a total scattering cross-section of ∼10{sup 5} km{sup 2}. The coma has a logarithmic surface brightness gradient −1 over much of its surface, indicating sustained, steady-state dust production. A lack of clear evidence for the action of solar radiation pressure suggests that the dust particles are large, with a mean size ≳0.1 mm. Using a coma convolution model, we find a limit to the apparent magnitude of the nucleus V>25.2 (absolute magnitude H>12.9). With assumed geometric albedo p {sub V} = 0.04, the limit to the nucleus circular equivalent radius is <9 km. Prediscovery observations from 2013 show that the comet was also active at 23.7 au heliocentric distance. While neither water ice sublimation nor exothermic crystallization can account for the observed distant activity, the measured properties are consistent with activity driven by sublimating supervolatile ices such as CO{sub 2}, CO, O{sub 2}, and N{sub 2}. Survival of supervolatiles at the nucleus surface is likely a result of the comet’s recent arrival from the frigid Oort Cloud.

79 ASTRONOMY AND ASTROPHYSICS↗

The relation between optical and γ-ray emission in BL Lac sources

ABSTRACT The relativistic jets produced by some Active Galactic Nuclei (AGNs) are among the most efficient persistent sources of non-thermal radiation and represent an ideal laboratory for studying high-energy interactions. In particular, when the relativistic jet propagates along the observer’s line of sight, the beaming effect produces dominant signatures in the observed spectral energy distribution (SED), from the radio domain up to the highest energies, with the further possibility of resulting in radiation-particle multimessenger associations. In this work, we investigate the relationships between the emission of γ rays and the optical spectra of a sample of AGN, selected from BL Lac sources detected by the Fermi Large Area Telescope (Fermi-LAT). We find that there is a close relationship between the optical and γ-ray spectral indices. Despite all the limitations due to the non-simultaneity of the data, this observation strongly supports a substantial role of Synchrotron-Self Compton (SSC) radiation in a single zone leptonic scenario for most sources. This result simplifies the application of theoretical models to explore the physical parameters of the jets in this type of sources.

79 ASTRONOMY AND ASTROPHYSICS↗

pyEGAF: An open-source Python library for the Evaluated Gamma-ray Activation File

The Evaluated Gamma-ray Activation File (EGAF) is one of the most comprehensive resources for thermal neutron-capture data. This database contains data from prompt gamma activation analysis measurements carried out in a consistent manner using the same experimental configuration at the Budapest Research Reactor for 245 isotopes. Although these valuable datasets have been freely available for many years, one of the drawbacks is the outdated and cryptic Evaluated Nuclear Structure Data File (ENSDF) format that is currently adopted for dissemination, making it difficult for users unfamiliar with the format to access and utilize the data contained therein. Furthermore, the ENSDF format does not readily lend itself to modern computational technologies and a parser is required to interpret the complicated mixed-record format. To help overcome these challenges, we have developed a translator to convert the ENSDF-formatted datasets into an open standard JavaScript Object Notation (JSON) format enabling accessibility to applications using different programming languages running in different environments. To compliment this effort, we have also developed an open-source software package implemented in Python, pyEGAF, that is designed to interact with the JSON data structures for general purpose access, manipulation, and analysis of the neutron-capture $\gamma$-ray data in EGAF. The new format, together with the pyEGAF library, greatly enhances access to the wider applications community where EGAF data may be useful or is required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Guidance for Monitoring Passive Groundwater Remedies Over Extended Time Scales

Passive remediation can be appropriate where natural processes and actions such as institutional controls mitigate exposure to contaminated groundwater, achieving remedial action objectives and protectiveness of human health and the environment. Monitored natural attenuation (MNA) is a prevalent passive remediation strategy supported by a regulatory framework and monitoring design guidance. However, long-term passive remedies are usually selected in combination with at least one active remedy, such as source removal, in situ treatment, or pump-and-treat, functioning as a complementary method for achieving remediation objectives and meeting the applicable statutory and regulatory requirements. However, MNA and existing monitoring guidance primarily target situations where the remedial action objectives are met within a few decades. When time scales for passive remediation extend to many decades (50 years or more), a corresponding change in monitoring strategy is needed to adapt to the extended time scale. This document provides guidance for implementing an extended-scale monitoring (ESM) approach appropriate for long-duration passive remediation. Extended-scale is defined in this document with respect to time (i.e., a long duration of remediation) and a large enough physical scale such that downstream receptors will not be impacted within the remediation timeframe. ESM applies to slow-moving groundwater contaminant plumes and emphasizes monitoring primarily for potential exposure pathways. For this approach, the primary monitoring objective is to demonstrate that the plume diminishes before reaching the receptor zone or point of compliance and/or a receptor does not receive concentrations above the compliance limit. While the overall objectives of protecting human health and the environment are the same as for plumes where remediation can occur over a shorter time period, the time scales between decisions are longer and the dynamics of plume evolution are slower. To this end, a scenario-based strategy is described for different plume and source conditions, defining a containment and receptor zones. The containment zone is the area where the risk of exposure to groundwater contamination can be mitigated (e.g., through institutional controls) during the remediation time period. The receptor zone is defined as the area where exposure to groundwater contamination cannot be mitigated and compliance concentration standards must be met. Within the containment zone, slow plume migration may occur, leading to concentrations that exceed compliance standards. However, where distance to the receptor zone is large relative to plume migration and attenuation rate, this approach can be protective of the receptor zone. Selection of a long-duration passive remedy needs to be based on sufficient understanding of contaminant sources, hydrogeology, and contaminant plumes. A strong technical basis, supported by predictive analysis, is recommended to substantiate that contamination is expected to stay within the containment zone during the active remediation and attainment phase of the remedy, and diminish to meet compliance standards within the extended timeframe prior to reaching the receptor zone (e.g., many decades or even centuries). The ESM approach is based on verification of plume behavior and not on detailed plume dynamics. Monitoring is conducted to confirm expected behavior with an emphasis on exposure pathways to verify that plumes remain contained in areas where the protectiveness objectives can be met. ESM should not be adopted if there is significant risk of the plume extending beyond the containment zone. Given the slow movement within the containment zone, less frequent sampling is required relative to approaches used for conventional-scale remediation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pt-Co Bimetallic Catalyst Supported on Single Walled Carbon Nanotube: XAS and Aqueous Phase Reforming Activity Studies

We have developed a simple method to create a catalyst with atomically dispersed Pt on top of Co nanoparticles on single walled carbon nanotubes (SWNT) supports by sequential impregnation of Pt(II) and Co(II) solutions following by hydrogen reduction. The aqueous phase reforming activity is much higher than for Pt monometallic catalysts on SWNT supports prepared by several methods, either pre-reduced in hydrogen or in the liquid phase. The high selectivity of the monometallic catalysts is maintained for the bimetallic systems. The Extended X-ray Absorption Fine Structure (EXAFS) results at the Pt LIII edge show no observable Pt-Pt bond. Only Pt-Co bonds were observed, indicating high dispersion of Pt. The enhanced activity comes from two sources: the high dispersion of Pt and the effect of the Co as co-catalyst or modifier. This contribution demonstrates the possibility to further engineer bimetallic catalysts to improve the aqueous phase reforming activity, especially to retain good selectivity at high conversion.

08 HYDROGEN↗

WE-E-BRE-01: An Image-Based Skeletal Dosimetry Model for the ICRP Reference Adult Female - Internal Electron Sources

Purpose: Limitations seen in previous skeletal dosimetry models, which are still employed in commonly used software today, include the lack of consideration of electron escape and cross-fire from cortical bone, the modeling of infinite spongiosa, the disregard of the effect of varying cellularity on active marrow self-irradiation, and the lack of use of the more recent ICRP definition of a 50 micron surrogate tissue region for the osteoprogenitor cells - shallow marrow. These limitations were addressed in the present dosimetry model. Methods: Electron transport was completed to determine specific absorbed fractions to active marrow and shallow marrow of the skeletal regions of the adult female. The bone macrostructure was obtained from the whole-body hybrid computational phantom of the UF series of reference phantoms, while the bone microstructure was derived from microCT images of skeletal region samples taken from a 45 year-old female cadaver. The target tissue regions were active marrow and shallow marrow. The source tissues were active marrow, inactive marrow, trabecular bone volume, trabecular bone surfaces, cortical bone volume and cortical bone surfaces. The marrow cellularity was varied from 10 to 100 percent for active marrow self-irradiation. A total of 33 discrete electron energies, ranging from 1 keV to 10 MeV, were either simulated or modeled analytically. Results: The method of combining macro- and microstructure absorbed fractions calculated using MCNPX electron transport was found to yield results similar to those determined with the PIRT model for the UF adult male in the Hough et al. study. Conclusion: The calculated skeletal averaged absorbed fractions for each source-target combination were found to follow similar trends of more recent dosimetry models (image-based models) and did not follow current models used in nuclear medicine dosimetry at high energies (due to that models use of an infinite expanse of trabecular spongiosa)

60 APPLIED LIFE SCIENCES↗

SIMULTANEOUS MULTI-WAVELENGTH OBSERVATIONS OF MAGNETIC ACTIVITY IN ULTRACOOL DWARFS. III. X-RAY, RADIO, AND Halpha ACTIVITY TRENDS IN M AND L DWARFS

As part of our on-going investigation into the magnetic field properties of ultracool dwarfs, we present simultaneous radio, X-ray, and Halpha observations of three M9.5-L2.5 dwarfs (BRI 0021-0214, LSR 060230.4+391059, and 2MASS J052338.2-140302). We do not detect X-ray or radio emission from any of the three sources, despite previous detections of radio emission from BRI 0021 and 2M0523-14. Steady and variable Halpha emission are detected from 2M0523-14 and BRI 0021, respectively, while no Halpha emission is detected from LSR 0602+39. Overall, our survey of nine M8-L5 dwarfs doubles the number of ultracool dwarfs observed in X-rays, and triples the number of L dwarfs, providing in addition the deepest limits to date, log(L{sub X}/L{sub bol}) approx< -5. With this larger sample we find the first clear evidence for a substantial reduction in X-ray activity, by about two orders of magnitude, from mid-M to mid-L dwarfs. We find that the decline in Halpha roughly follows L{sub Ha}lpha/L{sub bol} propor to 10{sup -0.4x(SP-6)} for SP >= 6, where SP = 0 for spectral type M0. In the radio band, however, the luminosity remains relatively unchanged from M0 to L4, leading to a substantial increase in L{sub rad}/L{sub bol}. Our survey also provides the first comprehensive set of simultaneous radio/X-ray/Halpha observations of ultracool dwarfs, and reveals a clear breakdown of the radio/X-ray correlation beyond spectral type M7, evolving smoothly from L{sub n}u{sub ,rad}/L{sub X} approx 10{sup -15.5} to approx10{sup -11.5} Hz{sup -1} over the narrow spectral-type range M7-M9. This breakdown reflects the substantial reduction in X-ray activity beyond M7, but its physical origin remains unclear since, as evidenced by the uniform radio emission, there is no drop in the field dissipation and particle acceleration efficiency. Based on the results of our survey, we conclude that a further investigation of magnetic activity in ultracool dwarfs will benefit from a two-pronged approach: multi-rotation observations of nearby known active sources and a snapshot survey of a large sample within approx50 pc to uncover rare flaring objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of a deuterium-deuterium neutron generator for the Add-A-Source waste matrix correction technique

Neutron generators offer an alternative to radioactive sources in the application of active techniques for nondestructive assay of nuclear materials. The Add-A-Source technique has enabled improvements in the ability to accurately measure waste bearing nuclear materials by measuring and correcting for the non-nuclear matrix effect. The technique has historically been performed with a Cf-252 spontaneous fission source. Here, in this work, we have demonstrated the use of a Deuterium-deuterium neutron generator in place of the Cf-252 source. A DD generator enables operational advantages and allows the simplification of the instrument design, while offering equivalent corrective performance as a Cf-252 source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids

Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Source apportionment of VOCs, IVOCs and SVOCs by positive matrix factorization in suburban Livermore, California

Abstract. Gas- and particle-phase molecular markers provide highly specific information about the sources and atmospheric processes that contribute to air pollution. In urban areas, major sources of pollution are changing as regulation selectively mitigates some pollution sources and climate change impacts the surrounding environment. In this study, a comprehensive thermal desorption aerosol gas chromatograph (cTAG) was used to measure volatile, intermediate-volatility and semivolatile molecular markers every other hour over a 10 d period from 11 to 21 April 2018 in suburban Livermore, California. Source apportionment via positive matrix factorization (PMF) was performed to identify major sources of pollution. The PMF analysis identified 13 components, including emissions from gasoline, consumer products, biomass burning, secondary oxidation, aged regional transport and several factors associated with single compounds or specific events with unique compositions. The gasoline factor had a distinct morning peak in concentration but lacked a corresponding evening peak, suggesting commute-related traffic emissions are dominated by cold starts in residential areas. More monoterpene and monoterpenoid mass was assigned to consumer product emissions than biogenic sources, underscoring the increasing importance of volatile chemical products to urban emissions. Daytime isoprene concentrations were controlled by biogenic sunlight- and temperature-dependent processes, mediated by strong midday mixing, but gasoline was found to be the dominant and likely only source of isoprene at night. Biomass burning markers indicated residential wood burning activity remained an important pollution source even in the springtime. This study demonstrates that specific high-time-resolution molecular marker measurements across a wide range of volatility enable more comprehensive pollution source profiles than a narrower volatility range would allow.

54 ENVIRONMENTAL SCIENCES↗

Source Range Detector Response Modeling using VERA

The CASL reactor simulation package VERA has been adapted to provide high-fidelity simulation capabilities for modeling source range detector response during subcritical reactor configurations. New features include the activation and shuffling of secondary source assemblies, transfer of burned fuel neutron emission data from the ORIGEN depletion solver to the MPACT deterministic neutron transport solver, allowance of user-defined sources in MPACT based on material composition, ability to solve the subcritical source-driven system with neutron multiplication using the MPACT diffusion solver, and transfer of the calculated fission source from MPACT to the continuous energy Monte Carlo solver Shift for final detector response evaluation. These new capabilities were benchmarked against Watts Bar Unit 1 plant operating data and found to be in very good agreement.

Gentry, Cole↗

Radio and γ-ray follow-up of the exceptionally high-activity state of PKS 1510-089 in 2011

In this paper, we investigate the radio and γ-ray variability of the flat spectrum radio quasar PKS 1510-089 in the time range between 2010 November and 2012 January. In this period the source showed an intense activity, with two major γ-ray flares detected in 2011 July and October. During the latter episode both the γ-ray and the radio flux density reached their historical peak. Multiwavelength analysis shows a rotation of about 380° of the optical polarization angle close in time with the rapid and strong γ-ray flare in 2011 July. An enhancement of the optical emission and an increase of the fractional polarization both in the optical and in radio bands are observed about three weeks later, close in time with another γ-ray outburst. On the other hand, after 2011 September a huge radio outburst has been detected, first in the millimetre regime followed with some time delay at centimetre down to decimetre wavelengths. This radio flare is characterized by a rising and a decaying stage, in agreement with the formation of a shock and its evolution, as a consequence of expansion and radiative cooling. Lastly, if the γ-ray flare observed in 2011 October is related to this radio outburst, then this strongly indicates that the region responsible for the γ-ray variability is not within the broad line, but a few parsecs downstream along the jet.

79 ASTRONOMY AND ASTROPHYSICS↗

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Monte Carlo/Deterministic Methods for Accelerating Active Interrogation Modeling

The potential for smuggling special nuclear material (SNM) into the United States is a major concern to homeland security, so federal agencies are investigating a variety of preventive measures, including detection and interdiction of SNM during transport. One approach for SNM detection, called active interrogation, uses a radiation source, such as a beam of neutrons or photons, to scan cargo containers and detect the products of induced fissions. In realistic cargo transport scenarios, the process of inducing and detecting fissions in SNM is difficult due to the presence of various and potentially thick materials between the radiation source and the SNM, and the practical limitations on radiation source strength and detection capabilities. Therefore, computer simulations are being used, along with experimental measurements, in efforts to design effective active interrogation detection systems. The computer simulations mostly consist of simulating radiation transport from the source to the detector region(s). Although the Monte Carlo method is predominantly used for these simulations, difficulties persist related to calculating statistically meaningful detector responses in practical computing times, thereby limiting their usefulness for design and evaluation of practical active interrogation systems. In previous work, the benefits of hybrid methods that use the results of approximate deterministic transport calculations to accelerate high-fidelity Monte Carlo simulations have been demonstrated for source-detector type problems. In this work, the hybrid methods are applied and evaluated for three example active interrogation problems. Additionally, a new approach is presented that uses multiple goal-based importance functions depending on a particle s relevance to the ultimate goal of the simulation. Results from the examples demonstrate that the application of hybrid methods to active interrogation problems dramatically increases their calculational efficiency.

active interrogation↗

Development of cell-based assay for predictively evaluating the FcγR-mediated human immune cell activation by therapeutic monoclonal antibodies

Therapeutic monoclonal antibodies (mAbs) have important roles in treatments for various cancers and inflammatory diseases. Their highly target specificities provide controlled safety profiles. However, therapeutic mAbs commonly pose a risk of the induction of the release of cytokines, which may result in adverse events including infusion reaction and cytokine release syndrome. Several mechanisms are involved in the cytokine releases induced by therapeutic mAbs, and the activation of immune effector cells via Fcγ receptors (FcγRs) is one of the putative mechanisms for most IgG-subclass mAbs. The relationship between cytokine releases and mAbs' Fc functions is not fully understood. Here we developed a simple reporter cell-based assay for estimating the FcγR-mediated activation of human immune effector cells by mAbs. Our use of the cell-based assay to compare Fc-engineered mAbs with different FcγR-activation profiles revealed that the releases of inflammatory cytokines and chemokines from human peripheral blood mononuclear cells (hPBMCs) induced by the mAbs were elevated by treatment with Fc-engineered mAbs with higher FcγR-activation properties. Our results also suggested the involvement of monocytic effector cells in the activation of hPBMCs as sources of released cytokines and chemokines, which may lead to the immune cell-mediated adverse events. Our new reporter cell assay is a promising tool for evaluating and predicting the activation of human immune cells by novel Fc-engineered mAbs. - Highlights: • A simple reporter assay for estimating the FcγR activation by mAbs is developed. • mAbs with higher FcγR-activation properties strongly activate hPBMC. • Monocytic effector cells are involved in the activation of hPBMCs by mAbs. • The reporter assay is useful for predicting the FcγR-mediated responses of hPBMCs.

60 APPLIED LIFE SCIENCES↗

SU-C-9A-04: Alternative Analytic Solution to the Paralyzable Detector Model to Calculate Deadtime and Deadtime Loss

Purpose: Some common methods to solve for deadtime are (1) dual-source method, which assumes two equal activities; (2) model fitting, which requires multiple acquisitions as source decays; and (3) lossless model, which assumes no deadtime loss at low count rates. We propose a new analytic alternative solution to calculate deadtime for paralyzable gamma camera. Methods: Deadtime T can be calculated analytically from two distinct observed count rates M1 and M2 when the ratio of the true count rates alpha=N2/N1 is known. Alpha can be measured as a ratio of two measured activities using dose calibrators or via radioactive decay. Knowledge of alpha creates a system with 2 equations and 2 unknowns, i.e., T and N1. To verify the validity of the proposed method, projections of a non-uniform phantom (4GBq 99mTc) were acquired in using Siemens SymbiaS multiple times over 48 hours. Each projection has >100kcts. The deadtime for each projection was calculated by fitting the data to a paralyzable model and also by using the proposed 2-acquisition method. The two estimates of deadtime were compared using the Bland-Altmann method. In addition, the dependency of uncertainty in T on uncertainty in alpha was investigated for several imaging conditions. Results: The results strongly suggest that the 2-acquisition method is equivalent to the fitting method. The Bland-Altman analysis yielded mean difference in deadtime estimate of ∼0.076us (95%CI: -0.049us, 0.103us) between the 2-acquisition and model fitting methods. The 95% limits of agreement were calculated to be -0.104 to 0.256us. The uncertainty in deadtime calculated using the proposed method is highly dependent on the uncertainty in the ratio alpha. Conclusion: The 2-acquisition method was found to be equivalent to the parameter fitting method. The proposed method offers a simpler and more practical way to analytically solve for a paralyzable detector deadtime, especially during physics testing.

07 ISOTOPE AND RADIATION SOURCES↗