Proceedings of the Second Infrared Detector Technology Workshop

The workshop focused on infrared detector, detector array, and cryogenic electronic technologies relevant to low-background space astronomy. Papers are organized into the following categories: discrete infrared detectors and readout electronics; advanced bolometers; intrinsic integrated infrared arrays; and extrinsic integrated infrared arrays. Status reports on the Space Infrared Telescope Facility (SIRTF) and Infrared Space Observatory (ISO) programs are also included.

Mccreight, C. R.↗

A fast numerical method for determining the optimum SNR of an array subject to a Q factor constraint.

The problem of finding the optimum current excitations for a point-detector array which extracts a signal from background noise using the criterion of maximizing the SNR subject to a constraint on the supergain ratio (or Q factor) has recently been solved. The formulation reduced the problem to one of solving for the roots of a polynomial whose coefficients are, in general, complex. We demonstrate that by making a certain transformation, it becomes possible to employ a state variable technique which changes the problem into one of finding the eigenvalues of a real matrix which is considerably faster to do.

Winkler, L. P.↗

Sensor requirements for Earth and planetary observations

Future generations of Earth and planetary remote sensing instruments will require extensive developments of new long-wave and very long-wave infrared detectors. The upcoming NASA Earth Observing System (EOS) will carry a suite of instruments to monitor a wide range of atmospheric and surface parameters with an unprecedented degree of accuracy for a period of 10 to 15 years. These instruments will observe Earth over a wide spectral range extending from the visible to nearly 17 micrometers with a moderate to high spectral and spacial resolution. In addition to expected improvements in communication bandwidth and both ground and on-board computing power, these new sensor systems will need large two-dimensional detector arrays. Such arrays exist for visible wavelengths and, to a lesser extent, for short wavelength infrared systems. The most dramatic need is for new Long Wavelength Infrared (LWIR) and Very Long Wavelength Infrared (VLWIR) detector technologies that are compatible with area array readout devices and can operate in the temperature range supported by long life, low power refrigerators. A scientific need for radiometric and calibration accuracies approaching 1 percent translates into a requirement for detectors with excellent linearity, stability and insensitivity to operating conditions and space radiation. Current examples of the kind of scientific missions these new thermal IR detectors would enhance in the future include instruments for Earth science such as Orbital Volcanological Observations (OVO), Atmospheric Infrared Sounder (AIRS), Moderate Resolution Imaging Spectrometer (MODIS), and Spectroscopy in the Atmosphere using Far Infrared Emission (SAFIRE). Planetary exploration missions such as Cassini also provide examples of instrument concepts that could be enhanced by new IR detector technologies.

Chahine, Moustafa T.↗

Automated Absorber Attachment for X-ray Microcalorimeter Arrays

Our goal is to develop a method for the automated attachment of large numbers of absorber tiles to large format detector arrays. This development includes the fabrication of high quality, closely spaced HgTe absorber tiles that are properly positioned for pick-and-place by our FC150 flip chip bonder. The FC150 also transfers the appropriate minute amount of epoxy to the detectors for permanent attachment of the absorbers. The success of this development will replace an arduous, risky and highly manual task with a reliable, high-precision automated process.

Moseley, S.↗

Advances in Detector Technology for Infrared Astronomy

Progress in semiconductor materials and processing technology has allowed the development of infrared detector arrays with unprecedented sensitivity, for imaging and spectroscopic applications in astronomy. The earlier discrete-detector approach has been replaced by large-element (up to 1024 x 1024 pixel), multiplexed devices. Progress has been made against a number of key limiting factors, such as quantum efficiency, noise, spectral response, linearity, and dark current. Future developments will focus on the need for even larger arrays, which operate at higher temperatures.

McCreight, Craig↗

Properties of states near 𝐸 𝑥 = 6 MeV in 18 Ne through 17 F +𝑝 scattering

The rate of energy production in the hot-CNO cycle and breakout to the rapid-proton capture process in Type I X-ray bursts is strongly related to the 14 O⁡(𝛼,𝑝)⁢ 17 F reaction rate. The properties of states in 18 Ne near 𝐸 𝑥 = 6.1–6.3 MeV are important for understanding the 14 O⁡(𝛼,𝑝)⁢ 17 F reaction rate. In order to study 18 Ne resonances around this energy region, the RESOLUT radioactive-ion beam facility at Florida State University was used to perform 17 F⁡(𝑝,𝑝)⁢ 17 F elastic scattering on a polypropylene target under inverse kinematics. Scattered protons were detected in a silicon-strip detector array while recoiling 17 F ions were detected in coincidence in a gas ionization detector. An 𝑅-matrix analysis of measured cross sections was conducted along with a reanalysis of data from previous 17 F +𝑝 measurements. All the data analyzed are well described by a consistent set of parameters with a 1 − assignment for a state at 6.14(1) MeV. A second comparable solution is also found with a 3 − assignment for the 6.14(1) MeV state. There is no conclusive evidence supporting one of the two solutions over the other. The rates of the 14 O⁡(𝛼,p)⁢ 17 F reaction that are determined from the two solutions differ by up to an order of magnitude.

6 ≤ A ≤ 19↗

Summary of the Graduate Mentoring Assistance Program for PNNL PNNL.12.006 (April 2012 – May 31, 2013)

Summary of Students and Projects: Sarah Bender: The possible improvement of the Multi-Isotope Process (MIP) Monitor by the addition of Compton suppression is investigated for this study. The Compton continuum from the dominant 661.7 keV Cs-137 fission product peak obscures lower energy lines which could be used for spectral and multivariate analysis. A novel Compton suppression system which uses fast, room-temperature materials will be developed using simulation. As opposed to the standard high purity germanium (HPGe) detector suppressed using a thallium-doped sodium iodide (NaI(Tl)) guard detector array, cerium-doped lanthanum bromide (LaBr3) will be used as the primary spectroscopic detector. For Sarah’s Master’s degree, she constructed and validated the unsuppressed detector response of the Pennsylvania State University (PSU)-Compton suppression system. For Sarah’s PhD, she is completing that simulation by including the suppressed operation which will be validated with spent fuel samples. She is also going to use the validation of suppressed operation to predict the detector response of a LaBr3 based Compton suppression system. Richard Clark: Richard Clark completed his study this FY of a new technique known as Intrinsic Dosimetry. Intrinsic Dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering the total absorbed dose received by a container in tandem with the physical characteristics of the radioactive material housed within that container, this method has the potential to provide enhanced pathway information regarding the history of the container and its radioactive contents. The latest in a series of experiments designed to validate and demonstrate this newly developed tool are reported. Kenneth Dayman: The MIP Monitor is an online, non-destructive approach to process monitoring in a nuclear fuel reprocessing facility using gamma spectra taken of process streams and multivariate data analysis to detect anomalies in operation. Last year, Mr. Dayman investigated methods to classify spent nuclear fuel according to both reactor type and burn up based on the constituent nuclide activities, which may be used to more accurately calibrate other models in an analysis scheme in order to improve the accuracy and precision of predictions. He is currently writing up his results for publication and has transitioned to another project with Dr. Derrick Haas at PNNL.

Schwantes, Jon M.↗

The NASA/Marshall Space Flight Center program in gamma-ray burst astronomy

The research program in gamma-ray burst astronomy at the NASA/Marshall Space Flight Center is described. Large-area scintillation detector arrays have been flown on high-altitude balloons, and an array is being developed for the Gamma-Ray Observatory. The design of these detectors is described along with results obtained from previous balloon flights.

Fishman, G. J.↗

Geostationary Coastal and Air Pollution Events (GeoCAPE) Filter Radiometer (FR)

The GeoCAPE Filter Radiometer (FR) Study is a different instrument type than all of the previous IDL GeoCape studies. The customer primary goals are to keep mass, volume and cost to a minimum while meeting the science objectives and maximizing flight opportunities by fitting on the largest number of GEO accommodations possible. Minimize total mission costs by riding on a commercial GEO satellite. For this instrument type, the coverage rate, km 2 min, was significantly increased while reducing the nadir ground sample size to 250m. This was accomplished by analyzing a large 2d area for each integration period. The field of view will be imaged on a 4k x 4k detector array of 15 micrometer pixels. Each ground pixel is spread over 2 x 2 detector pixels so the instantaneous field of view (IFOV) is 2048 X 2048 ground pixels. The baseline is, for each field of view 50 sequential snapshot images are taken, each with a different filter, before indexing the scan mirror to the next IFOV. A delta would be to add additional filters.

Geo Cape↗

The Future of Single- to Multi-band Detector Technologies: Review

Using classical optical components such as filters, prisms and gratings to separate the desired wavelengths before they reach the detectors results in complex optical systems composed of heavy components. A simpler system will result by utilizing a single optical system and a detector that responds separately to each wavelength band. Therefore, a continuous endeavors to develop the capability to reliably fabricate detector arrays that respond to multiple wavelength regions. In this article, we will review the state-of-the-art single and multicolor detector technologies over a wide spectral-range, for use in space-based and airborne remote sensing applications. Discussions will be focused on current and the most recently developed focal plane arrays (FPA) in addition to emphasizing future development in UV-to-Far infrared multicolor FPA detectors for next generation space-based instruments to measure water vapor and greenhouse gases. This novel detector component will make instruments designed for these critical measurements more efficient while reducing complexity and associated electronics and weight. Finally, we will discuss the ongoing multicolor detector technology efforts at NASA Langley Research Center, Jet Propulsion Laboratory, Rensselaer Polytechnic Institute, and others.

Abedin, M. Nurul↗

Optimization of Transition Edge Sensor Arrays for Cosmic Microwave Background Observations With the South Pole Telescope

In this paper, we describe the optimization of transition-edge-sensor (TES) detector arrays for the third-generation camera for the South PoleTelescope. The camera, which contains similar to 16 000 detectors, will make high-angular-resolution maps of the temperature and polarization of the cosmic microwave background. Our key results are scatter in the transition temperature of Ti/Au TESs is reduced by fabricating the TESs on a thin Ti(5 nm)/Au(5 nm) buffer layer and the thermal conductivity of the legs that support our detector islands is dominated by the SiOx dielectric in the microstrip transmission lines that run along the legs.

Ding, Junjia↗

Comparison of Results from Recent NNSA and CEA Measurements of the 239 Pu(n, f) Prompt Fission Neutron Spectrum

The National Nuclear Security Administration (NNSA)/DP French Alternative Energies and Atomic Energy Commission (CEA)/DAM agreement on cooperation on fundamental science is a U.S.-French collaborative effort to combine intellectual and experimental resources and further the relevant nuclear science. Recently, both the NNSA and CEA experimental teams performed high-statistics measurements of the 239 Pu(n, f) prompt fission neutron spectrum (PFNS) at the Los Alamos Neutron Science Center, both of which were recently published in the journal Physical Review C. These separate measurements used the same experimental area and a common neutron detector array, but differ in many aspects, including background assessments, data acquisition systems and philosophies, fission detectors, and PFNS extraction techniques. Hence, some aspects of the experimental methods and associated uncertainties are highly correlated while others are independent. The results from both measurements broke new ground for PFNS measurements given their higher accuracy and more detailed study of corrections necessary for the measured quantity compared to existing literature measurements, and both will significantly impact PFNS nuclear data evaluations for the foreseeable future. Here, the focus of this work is to document a comparison of the results from these distinct measurements in terms of the acquired data, the PFNS results, and the measured average PFNS energies. While systematic differences between the PFNS results are present on the 1–3% level, the acquired data relative to each respective measurement at low incident neutron energies are in remarkable agreement, as are the conclusions regarding the magnitude and position of features in the PFNS relating to second-chance fission, third-chance fission, and pre-equilibrium neutron emission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Second-phase Development of the China JinPing Underground Laboratory

During 2013-2015 an expansion of the China JinPing underground Laboratory (CJPL) will be undertaken along a main branch of a bypass tunnel in the JinPing tunnel complex. This second phase of CJPL will increase laboratory space to approximately 96,000 m 3 , which can be compared to the existing CJPL-I volume of ∼ 4,000 m 3 . One design configuration has eight additional hall spaces, each over 60 m long and approximately12 m in width, with overburdens of about 2.4 km of rock, oriented parallel to and away from the main water transport and auto traffic tunnels. There are additional possibilities for further expansions at a nearby second bypass tunnel and along the entrance and exit branches of both bypass tunnels, potentially leading to an expanded CJPL comparable in size to Gran Sasso. Concurrent with the excavation activities, planning is underway for dark matter and other rare- event detectors, as well as for geophysics/engineering and other coupled multi-disciplinary sensors. In the town meeting on 8 September, 2013 at Asilomar, CA, associated with the 13 th International Conference on Topics in Astroparticle and Underground Physics (TAUP), presentations and panel discussions addressed plans for one-ton expansions of the current CJPL germanium detector array of the China Darkmatter EXperiment (CDEX) collaboration and of the duel-phase xenon detector of the Panda-X collaboration, as well as possible new detector initiatives for dark matter studies, low-energy solar neutrino detection, neutrinoless double beta searches, and geoneutrinos. JinPing was also discussed as a site for a low-energy nuclear astrophysics accelerator. Geophysics/engineering opportunities include acoustic and micro-seismic monitoring of rock bursts during and after excavation, coupled-process in situ measurements, local, regional, and global monitoring of seismically induced radon emission, and electromagnetic signals. Additional ideas and projects will likely be developed in the next few years, driven by China’s domestic needs and by international experiments requiring access to very great depths.

58 GEOSCIENCES↗

A new detector for mass spectrometry: Direct detection of low energy ions using a multi-pixel photon counter

A new type of ion detector for mass spectrometry and general detection of low energy ions is presented. The detector consists of a scintillator optically coupled to a single-photon avalanche photodiode (SPAD) array. A prototype sensor has been constructed from a LYSO (Lu{sub 1.8}Y{sub 0.2}SiO{sub 5}(Ce)) scintillator crystal coupled to a commercial SPAD array detector. As proof of concept, the detector is used to record the time-of-flight mass spectra of butanone and carbon disulphide, and the dependence of detection sensitivity on the ion kinetic energy is characterised.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results From Cs Activated GaN Photocathode Development for MCP Detector Systems at GSFC

We describe the development of high quantum efficiency W photocathodes for use in large area two dimensional microchannel plate based detector arrays to enable new W space astronomy missions. Future W missions will require improvements in detector sensitivity, which has the most leverage for cost-effective improvements in overall telescope/instrument sensitivity. We use new materials such as p-doped GaN, AIGaN, ZnMgO, Sic and diamond. We have currently obtained QE values > 40 % at 185 nm with Cesiated GaN, and hope to demonstrate higher values in the future. By using controlled internal fields and nano-structuring of the surfaces, we plan to provide field emission assistance for photoelectrons while maintaining their energy distinction from dark noise electrons. We will transfer these methods from GaN to ZnMgO, a new family of wide band-gap materials more compatible with microchannel plates. We also are exploring technical parameters such as doping profiles, internal and external field strengths, angle of incidence, field emission assistance, surface preparation, etc.

Norton, Tim↗

SU-E-T-150: Brachytherapy QA Employing a High Resolution Liquid Filled Ionisation Chamber Array: Initial Experience and Limitations

Purpose: Verifying a complex 3D brachytherapy dose distribution by measurement is non-trivial. Ideally a photon detector array should be independent of energy and angle, have high spatial resolution and be robust for routine clinical use. Methods: An iridium-192 source was used. A PMMA jig was constructed comprising an outer slab and a central insert with eight milled channels for 1.33mm (outer diameter) steel needles, see figure. All calculations were performed using an empty CT study reconstructing eight virtual needles (QA-CT), using the v2 source model (Elekta AG, Sweden). A high resolution liquid filled ionisation chamber array SRS1000, together with Verisoft software v6.0 (PTW Freiburg, Germany), was used to perform measurements of plans of increasing complexity to evaluate its suitability for device- and patient-specific QA. The dimension of backscatter material was investigated. The patient plan dwell time distribution was entered manually into the QA-CT and the dose distribution was calculated. Results: Our measurements indicate that the array is independent of energy and angle. The resulting measured dose values are linearly interpolated to 2025 values. Shifts of 1mm of the entire needle are readily detectable. Individual dwell position shifts (2.5mm) are also readily measurable. Moreover a dwell time increase of 1 second both in the edge and central region are detectable. Conclusion: The high resolution SRS1000 array is a powerful instrument for brachytherapy QA enabling 977 simultaneous measurements to be performed. Our measurements suggest 60mm of RW3 backscatter material upstream and downstream are sufficient. Local percentage difference analysis is useful for device based QA, normalized relative percentage difference is arguably better for patient specific QA. Automated transfer of patient plan dwell time distribution to the QA plan is required to enable a comprehensive patient QA study to be performed. Moreover the described measurement technique can be used for commissioning new brachytherapy applicators.

60 APPLIED LIFE SCIENCES↗

X-Ray Detector Research at MSFC for Space Applications

NASA's Vision for Space Exploration has specific goals aimed at exploring the Solar System. This vision, under presidential mandate includes landing humans on the moon before the end of the next decade, paving the way for eventual journeys to Mars and beyond. The first missions to the moon will be in the form of both Orbiters and Landers, with the goal of paving the way for human return. One of the instruments we are currently working on,in collaboration with Brookhaven National Laboratory, is a lunar orbiter fluorescent x-ray spectrometer to finely map the light elements (down to Carbon) on surface of the moon. Funded NASA s Planetary Instrument Definition and Development Program the instrument is based on silicon drift detector arrays read out by custom ASICs. These offer the promise of high spectral resolution, necessary for resolving weak lines against a strong background continuum, and very low power requirements, necessary for large areas (greater than 500 square centimeters) required for future lunar missions. Further, the inherent radiation hardness of these detectors makes them ideal candidates for exploring the Jovian system, where the harsh radiation environment from Jupiter s radiation belts creates unfavorable detector conditions. Looking beyond our solar system, in the hard x-ray regime (20-80keV.), we are studying Cadmium-Zinc-Telluride pixilated detectors as feasible candidates for focal plane detectors of a hard x-ray telescope. This energy region bridges the gap between thermal and non-thermal x-ray emission from astronomical sources, will allow us to better understand supernovae nucleosynthesis (such as through the Ti-44 lines at 68keV and 78keV), Active Galactic Nuclei and other compact objects, more completely. The detectors that we are characterizing are 2mm in thickness and are pixilated with a 16x16 array of 300 micrometer pitch pixels (50micometer gap). These detectors are designed at Rutherford Appleton Laboratory, material is from eV Products, and polymer flip-chip assembly was performed by a commercial vendor. An energy resolution of 2.0% at 60keV (or better) should allow us to sufficiently distinguish lines of interest from background continuum, and the detector spatial resolution should be fine enough to over-sample the focal spot from the x-ray focusing optics by about a factor of two. Full technical details of these developments will be presented.

Gaskin, Jessica↗