Search NASA⌕ Search

SEARCH · Search NASA

Results for “cable systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Laboratory evaluation of distributed coaxial cable temperature sensors for application in CO 2 sequestration well characterization: Original Research Article: Laboratory evaluation of distributed coaxial cable temperature

Downhole monitoring plays a crucial part in a geological carbon dioxide (CO 2 ) sequestration project, especially in providing early warnings of failure. However, most downhole monitoring technologies are often low in spatial resolution and time-consuming, or expensive and have system longevity issues. To address this issue, a robust and cost-effective distributed coaxial cable Fabry-Perot interferometer-based temperature sensor is proposed for real-time downhole monitoring. The coaxial cable sensor (CCS) was made in house and tested using a high pressure high temperature (HPHT) testing apparatus to study the sensor accuracy, sensitivity, stability, and crosstalk effect in simulated downhole conditions. The laboratory test results indicate that the sensor can work under simulated downhole conditions of pressures up to 1000 psia and temperatures up to 110°C. At 1 ATM, the sensor has an accuracy of about 1%. At 1000 psia, the hysteresis phenomenon is observed, but it is reduced and tends to stabilize after repeated heating and cooling treatments. The pressure crosstalk effect was observed on the flexible cable sensor and minimized on the rigid cable sensor. The temperature and pressure range of the distributed CCS allows long-term in situ monitoring for a well depth up to 2500 feet, which would prove of great value in detecting temperature change associated with wellbore leakage that may lead to groundwater contamination.

54 ENVIRONMENTAL SCIENCES↗

A Megawatt-Scale Medium-Voltage High-Efficiency High Power Density “SiC+Si” Hybrid Three-Level ANPC Inverter for Aircraft Hybrid-Electric Propulsion Systems

A hybrid-electric propulsion system is an enabling technology to make the aircraft more fuel saving, quieter, and lower carbide emission. In this article, a megawatt (MW) scale power inverter based on a three-level active neutral-point-clamped (3L-ANPC) topology will be developed. To achieve high efficiency, the switching devices operating at carrier frequency in the power converter are configured by the emerging silicon carbide (SiC) metal-oxide-semiconductor field-effect transistors, while the conventional silicon (Si) insulated-gate bipolar transistors are selected for switches operating at the fundamental output frequency. To obtain high power density, dc bus voltage is increased from the conventional 270 V to medium voltage of 2.4 kV to reduce cable weight. Also, unlike the traditional 400 Hz dominated aircraft ac systems, the rated fundamental output frequency here is boosted to 1.4 kHz to drive the high-speed motor, which helps further to reduce the motor weight. Main hardware development and control modulation strategies are presented. Experimental findings are presented to verify the performance of this MW-scale medium-voltage “SiC+Si” hybrid 3L-ANPC inverter. It is shown that the 1-MW 3L-ANPC inverter can achieve a high efficiency of 99% and a high power density of 12 kVA/kg.

42 ENGINEERING↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off (PTO) system, which is the mechanism by which the energy absorbed by the prime mover is transformed into useable electrical. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency) and devices will see a sinusoidally varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled PTOs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the DOE sponsored Reference Model Project (RMP). The RMP was a partnered effort to develop open-source marine energy (ME) point designs as reference models (RMs) to benchmark ME technology performance and costs, methods for design and analysis of ME technologies, estimations for capital costs, operational costs, and levelized costs of energy (LCOE). The results from this study show torque is directly related to (1) the physical size of the machine required to increase the airgap sheer stresses, (2) the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both CAPEX and OPEX. This paper aims to be a critical benchmark in helping determine an “optimal” nameplate rating for wave energy devices and their associated PTO. With an optimized rating and sizing process, WEC costs can be reduced, and overall performance can be improved.

cables↗

Laboratory Studies of the Effects of Static and Variable Magnetic Fields on Freshwater Fish

There is considerable interest in the development of marine and hydrokinetic energy projects in rivers, estuaries, and coastal ocean waters of the United States. Hydrokinetic (HK) technologies convert the energy of moving water in river or tidal currents into electricity, without the impacts of dams and impoundments associated with conventional hydropower or the extraction and combustion of fossil fuels. The Federal Energy Regulatory Commission (FERC) maintains a database that displays the geographical distribution of proposed HK projects in inland and tidal waters (FERC 2012). As of March 2012, 77 preliminary permits had been issued to private developers to study HK projects in inland waters, the development of which would total over 8,000 MW. Most of these projects are proposed for the lower Mississippi River. In addition, the issuance of another 27 preliminary permits for HK projects in inland waters, and 3 preliminary permits for HK tidal projects (totaling over 3,100 MW) were under consideration by FERC. Although numerous HK designs are under development (see DOE 2009 for a description of the technologies and their potential environmental effects), the most commonly proposed projects entail arrays of rotating devices, much like submerged wind turbines, that are positioned in the high-velocity (high energy) river channels. The many diverse HK designs imply a diversity of environmental impacts, but a potential impact common to most is the effect on aquatic organisms of electromagnetic fields (EMF) created by the projects. The submerged electrical generator will emit an EMF into the surrounding water, as will underwater cables used to transmit electricity from the generator to the shore, between individual units in an array (inter-turbine cables), and between the array and a submerged step-up transformer. The electric current moving through these cables will induce magnetic fields in the immediate vicinity, which may affect the behavior or viability of fish and benthic invertebrates (Gill et al. 2005, 2009). It is known that numerous marine and freshwater organisms are sensitive to electrical and magnetic fields, often depending on them for such diverse activities as prey location and navigation (DOE 2009; Normandeau et al. 2011). Despite the wide range of aquatic organisms that are sensitive to EMF and the increasing numbers of underwater electrical transmitting cables being installed in rivers and coastal waters, little information is available to assess whether animals will be attracted, repelled, or unaffected by these new sources of EMF. This knowledge gap is especially significant for freshwater systems, where electrosensitive organisms such as paddlefish and sturgeon may interact with electrical transmission cables. We carried out a series of laboratory experiments to test the sensitivity of freshwater fish and invertebrates to the levels of EMF that are expected to be produced by HK projects in rivers. In this context, EM fields are likely to be emitted primarily by generators in the water column and by transmission cables on or buried in the substrate. The HK units will be located in areas of high-velocity waters that are used as only temporary habitats for most riverine species, so long-term exposure of fish and benthic invertebrates to EMF is unlikely. Rather, most aquatic organisms will be briefly exposed to the fields as they drift downstream or migrate upstream. Because the exposure of most aquatic organisms to EMF in a river would be relatively brief and non-lethal, we focused our investigations on detecting behavioral effects. For example, attraction to the EM fields could result in prolonged exposures to the fields or the HK rotor. On the other hand, avoidance reactions might hinder upstream migrations of fish. The experiments reported here are a continuation of studies begun in FY 2010, which focused on the potential effects of static magnetic fields on snails, clams, and fathead minnows (Cada et al. 2011). Those experiments found little indication that the behaviors of these freshwater species were altered by the static magnetic fields that would be created by submerged, direct current (DC)-transmitting electrical cables expected to be used by the HK developers. Laboratory experiments in FY 2011 examined the responses of additional fish species (sunfish, striped bass, and channel catfish) to the static magnetic fields. In addition, the effects of variable magnetic fields (that would be created by the HK generators and AC-transmitting cables) on swimming behavior of two electrosensitive fish species (paddlefish and lake sturgeon) were studied.

13 HYDRO ENERGY↗

Mechanism continuously measures static and dynamic cable loads

Pulley mechanism measures the tensile loads on a cable under static and dynamic conditions, without disturbing the continuity of operation of the system. A set of takeoff pulleys are mounted on a pivoted frame that is linked to a strain gage which measures the frame displacement as a function of the static or dynamic tensile load on the cable.

Source record↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters: Preprint

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off (PTO) system, which is the mechanism by which the energy absorbed by the prime mover is transformed into useable electrical. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency) and devices will see a sinusoidally varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled PTOs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the DOE sponsored Reference Model Project (RMP). The RMP was a partnered effort to develop open-source marine energy (ME) point designs as reference models (RMs) to benchmark ME technology performance and costs, methods for design and analysis of ME technologies, estimations for capital costs, operational costs, and levelized costs of energy (LCOE). The results from this study show torque is directly related to (1) the physical size of the machine required to increase the airgap sheer stresses, (2) the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both CAPEX and OPEX. This paper aims to be a critical benchmark in helping determine an “optimal” nameplate rating for wave energy devices and their associated PTO. With an optimized rating and sizing process, WEC costs can be reduced, and overall performance can be improved.

cables↗

Note: Easy-to-maintain electron cyclotron resonance (ECR) plasma sputtering apparatus featuring hybrid waveguide and coaxial cables for microwave delivery

The branched-waveguide electron cyclotron resonance plasma sputtering apparatus places quartz windows for transmitting microwaves into the plasma source not in the line of sight of the target. However, the quartz windows must be replaced after some time of operation. For maintenance, the loop waveguide branching from the T-junction must be dismounted and re-assembled accurately, which is a time-consuming job. We investigated substituting the waveguide branches with two sets of coaxial cables and waveguide/coaxial cable converters to simplify assembly as far as connection and disconnection go. The resulting hybrid system worked well for the purposes of plasma generation and film deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAVANNAH RIVER SITE TANK 18 AND TANK 19 WALL SAMPLER PERFORMANCE

A sampling tool was required to evaluate residual activity ({mu}Curies per square foot) on the inner wall surfaces of underground nuclear waste storage tanks. The tool was required to collect a small sample from the 3/8 inch thick tank walls. This paper documents the design, testing, and deployment of the remotely operated sampling device. The sampler provides material from a known surface area to estimate the overall surface contamination in the tank prior to closure. The sampler consisted of a sampler and mast assembly mast assembly, control system, and the sampler, or end effector, which is defined as the operating component of a robotic arm. The mast assembly consisted of a vertical 30 feet long, 3 inch by 3 inch, vertical steel mast and a cantilevered arm hinged at the bottom of the mast and lowered by cable to align the attached sampler to the wall. The sampler and mast assembly were raised and lowered through an opening in the tank tops, called a riser. The sampler is constructed of a mounting plate, a drill, springs to provide a drive force to the drill, a removable sampler head to collect the sample, a vacuum pump to draw the sample from the drill to a filter, and controls to operate the system. Once the sampler was positioned near the wall, electromagnets attached it to the wall, and the control system was operated to turn on the drill and vacuum to remove and collect a sample from the wall. Samples were collected on filters in removable sampler heads, which were readily transported for further laboratory testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off system, which is the mechanism by which the energy absorbed by the prime mover is transformed into usable electrical energy. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency), and devices will see a sinusoidal varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled power take-offs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the Reference Model Project sponsored by the U.S. Department of Energy. The Reference Model Project was a partnered effort to develop open-source marine energy point designs as reference models to benchmark marine energy technology performance and costs, methods for design and analysis of marine energy technologies, estimations for capital costs, operational costs, and levelized cost of energy. The results from this study show torque is directly related to (1) the physical size of the machine required to increase the air-gap sheer stresses, (2)the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both capital and operational expenditures. This paper aims to be a critical benchmark in helping determine an "optimal" nameplate rating for wave energy devices and their associated power take-offs. With an optimized rating and sizing process, WEC costs can be reduced and overall performance can be improved.

cables↗

Charge-Dissipative Electrical Cables

Electrical cables that dissipate spurious static electric charges, in addition to performing their main functions of conducting signals, have been developed. These cables are intended for use in trapped-ion or ionizing-radiation environments, in which electric charges tend to accumulate within, and on the surfaces of, dielectric layers of cables. If the charging rate exceeds the dissipation rate, charges can accumulate in excessive amounts, giving rise to high-current discharges that can damage electronic circuitry and/or systems connected to it. The basic idea of design and operation of charge-dissipative electrical cables is to drain spurious charges to ground by use of lossy (slightly electrically conductive) dielectric layers, possibly in conjunction with drain wires and/or drain shields (see figure). In typical cases, the drain wires and/or drain shields could be electrically grounded via the connector assemblies at the ends of the cables, in any of the conventional techniques for grounding signal conductors and signal shields. In some cases, signal shields could double as drain shields.

Kolasinski, John R.↗

The impact of changing the land surface scheme in ACCESS(v1.0/1.1) on the surface climatology

The Community Atmosphere Biosphere Land Exchange (CABLE) model has been coupled to the UK Met Office Unified Model (UM) within the existing framework of the Australian Community Climate and Earth System Simulator (ACCESS), replacing the Met Office Surface Exchange Scheme (MOSES). Here we investigate how features of the CABLE model impact on present-day surface climate using ACCESS atmosphere-only simulations. The main differences attributed to CABLE include a warmer winter and a cooler summer in the Northern Hemisphere (NH), earlier NH spring runoff from snowmelt, and smaller seasonal and diurnal temperature ranges. The cooler NH summer temperatures in canopy-covered regions are more consistent with observations and are attributed to two factors. Firstly, CABLE accounts for aerodynamic and radiative interactions between the canopy and the ground below; this placement of the canopy above the ground eliminates the need for a separate bare ground tile in canopy-covered areas. Secondly, CABLE simulates larger evapotranspiration fluxes and a slightly larger daytime cloud cover fraction. Warmer NH winter temperatures result from the parameterization of cold climate processes in CABLE in snow-covered areas. In particular, prognostic snow density increases through the winter and lowers the diurnally resolved snow albedo; variable snow thermal conductivity prevents early winter heat loss but allows more heat to enter the ground as the snow season progresses; liquid precipitation freezing within the snowpack delays the building of the snowpack in autumn and accelerates snow melting in spring. Altogether we find that the ACCESS simulation of surface air temperature benefits from the specific representation of the turbulent transport within and just above the canopy in the roughness sublayer as well as the more complex snow scheme in CABLE relative to MOSES.

54 ENVIRONMENTAL SCIENCES↗

Dynamic characteristics of a 20 kHz resonant power system - Fault identification and fault recovery

A detailed simulation of a dc inductor resonant driver and receiver is used to demonstrate the transient characteristics of a 20 kHz resonant power system during fault and overload conditions. The simulated system consists of a dc inductor resonant inverter (driver), a 50-meter transmission cable, and a dc inductor resonant receiver load. Of particular interest are the driver and receiver performance during fault and overload conditions and on the recovery characteristics following removal of the fault. The information gained from these studies sets the stage for further work in fault identification and autonomous power system control.

Wasynczuk, O.↗

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Modeling Deformable Linear Objects for Autonomous Robotic Outfitting of Lunar Surface Systems

This paper presents structural models of deformable linear objects (DLOs). DLOs are a subclass of deformable objects that encompasses common outfitting elements such as cables and ropes. Models are validated through hardware experiments, and integration in a robotic autonomy architecture for space environments is discussed. A persistent human presence on the lunar surface is one of the next major milestones in space exploration. This requires the development of robust extraplanetary construction technologies including structures and materials modeling and robotic systems. Previous robotic construction technology development has primarily focused on structural assembly, with significantly less focus on robotically performed outfitting tasks to instantiate subsystems providing power, data, life support, etc. These tasks involve manipulation of highly flexible elements, which are difficult to model, such as cable harnesses, ropes, and hoses. Robotic manipulation of DLOs, especially cable harnesses, is an active area of research as cable harnesses are essential for providing power and data to space assets. DLO models that can be used for robot manipulator trajectory generation are necessary for autonomous operation of lunar infrastructure. There are many proposed methods for modeling DLOs, and they primarily fall into three types: 1) discrete model-based, 2) continuum model-based, and 3) Neural Network-based. These types each have pros and cons, and the tradeoff between model accuracy and computational speed informs which type should be used. An understanding of this trade-off is imperative for real-time control of autonomous systems. High computational requirements reduce the speed of the model, making real-time control difficult, while accuracy is critical to preventing collisions. Discrete models, such as a mass-spring multibody representation, require relatively few calculations, and accuracy is directly tied to the step size of the discretization. Continuum models, such as a B-spline representation or a Cosserat rod model (a mix of continuous and discrete), are more informed of the structural properties of the cable and are much more accurate than a rigid body mass-spring model, but at significant computational cost. A Neural Network approach can provide an online solution with very few computational steps, but properly generating training data can be difficult and validation for an in-space application is not trivial. This paper explores the trade-off between different modeling approaches and compares accuracy and computational speed/complexity of the three types mentioned above. Model accuracy is evaluated using a cable in a static configuration. True cable shape is obtained using a depth camera for RGB images and point-cloud segmentation. The purpose of this experiment is to evaluate the trade-offs of different approaches to the DLO modeling problem. Understanding the tradeoffs between different cable modeling techniques paves the way for developing robotic control and planning architectures necessary for real-time manipulation of DLOs for lunar infrastructure outfitting. Real-time control is required for robotic systems to be able to actively manipulate a cable in a harsh environment where model and sensor errors compound, and environmental conditions can cause significant disturbances. Cable routing must be performed in areas with high density of objects/obstacles: through truss structures, near solar panels or mirror arrays, next to bundles of electrical equipment. Understanding the best way to plan and manipulate a cable without disrupting the environment or damaging the cable is imperative to robotic outfitting operations on the lunar surface.

Amy M Quartaro↗

Space station power management and distribution

The power system architecture is presented by a series of schematics which illustrate the power management and distribution (PMAD) system at the component level, including converters, controllers, switchgear, rotary power transfer devices, power and data cables, remote power controllers, and load converters. Power distribution options, reference power management, and control strategy are also outlined. A summary of advanced development status and plans and an overview of system test plans are presented.

Teren, F.↗

Geometry Optimization of Cable-Based Actuation for Small-Scale Model Testing of a Floating Marine Turbine: Preprint

This research aims to apply combined wave and tidal current loads to a small-scale floating marine current turbine in a wave tank, where an actuation system applies hydrodynamic and mooring forces on the hardware based on results from a simulation. We use a real-time hybrid test setup with physical wave forcing from the wave tank and simulated current and mooring forces implemented through a tensioned cable array. For this paper, we developed an optimization algorithm that adjusts the hardware geometry of the cable array to achieve more efficient tension allocation across the cables for the loads that need to be actuated. By adjusting the points where the cables are attached to the floating platform and the angles between the platform and the winches, an optimal cable geometry can be found to minimize tension variations in the lines, maintain the desired pretension, and prevent excessive tensions. We present the optimization problem formulation, the actuation system evaluation approach, and optimization results that show effective cable actuation setups that are being considered for implementation in the wave tank tests.

cable-based actuation↗

NASA Tech Briefs, June 2004

Topics covered include: COTS MEMS Flow-Measurement Probes; Measurement of an Evaporating Drop on a Reflective Substrate; Airplane Ice Detector Based on a Microwave Transmission Line; Microwave/Sonic Apparatus Measures Flow and Density in Pipe; Reducing Errors by Use of Redundancy in Gravity Measurements; Membrane-Based Water Evaporator for a Space Suit; Compact Microscope Imaging System with Intelligent Controls; Chirped-Superlattice, Blocked-Intersubband QWIP; Charge-Dissipative Electrical Cables; Deep-Sea Video Cameras Without Pressure Housings; RFID and Memory Devices Fabricated Integrally on Substrates; Analyzing Dynamics of Cooperating Spacecraft; Spacecraft Attitude Maneuver Planning Using Genetic Algorithms; Forensic Analysis of Compromised Computers; Document Concurrence System; Managing an Archive of Images; MPT Prediction of Aircraft-Engine Fan Noise; Improving Control of Two Motor Controllers; Electro-deionization Using Micro-separated Bipolar Membranes; Safer Electrolytes for Lithium-Ion Cells; Rotating Reverse-Osmosis for Water Purification; Making Precise Resonators for Mesoscale Vibratory Gyroscopes; Robotic End Effectors for Hard-Rock Climbing; Improved Nutation Damper for a Spin-Stabilized Spacecraft; Exhaust Nozzle for a Multitube Detonative Combustion Engine; Arc-Second Pointer for Balloon-Borne Astronomical Instrument; Compact, Automated Centrifugal Slide-Staining System; Two-Armed, Mobile, Sensate Research Robot; Compensating for Effects of Humidity on Electronic Noses; Brush/Fin Thermal Interfaces; Multispectral Scanner for Monitoring Plants; Coding for Communication Channels with Dead-Time Constraints; System for Better Spacing of Airplanes En Route; Algorithm for Training a Recurrent Multilayer Perceptron; Orbiter Interface Unit and Early Communication System; White-Light Nulling Interferometers for Detecting Planets; and Development of Methodology for Programming Autonomous Agents.

Source record↗

Electrical Resistivity Tomography data from 2016 to 2018 at the Lower Montane site in the East River Watershed, Colorado

This dataset contains time-lapse Electrical Resistivity Tomography (ERT) data along a transect located on the northeast-facing hillslope at the lower montane site (Pumphouse site) in the upper East River Watershed. The monitoring dataset covers the period from November 2, 2016, to August 6, 2018. In addition, the archive also contains a baseline dataset from October 9, 2016. The ERT transect consisted of 128 electrodes with an electrode spacing of 1.25 m. The acquisition system was located in the middle of the transect, about 50 m on one side, and included an MPT (Multi-Phase Technologies) ERT system, a mini computer, and batteries with solar panels. Acquisition occurred daily under normal circumstances. The first 16 electrodes (from the upper end of the transect) could not be used after the cable was damaged during the 2017–2018 winter. Also, due to multiple failures in the power system, the temporal resolution of the data is much lower in 2018 compared to 2016 and 2017. The data have been processed and used in Dafflon et al., 2023, and the baseline dataset was used in Falco et al., 2019 (see reference list). This archive contains the measurements (ER.zip containing csv files) for each of the 326 acquisition times and a filtered version where only electrodes 17 to 128 are included (ERT_sm.zip containing csv files). The archive also contains the baseline dataset and two acquisitions with full reciprocals (ERT_RB.zip containing csv files), as well as all the raw MPT files (ERT_raw_MTP.zip). The geometry (electrode position and elevation) is provided in Universal Transverse Mercator (UTM) 13N Geoid2012AB in the file named ERT_Location.csv. The archive contains 1 *.csv data files, four *.zip files, and three metadata *.csv files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗