Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

WE-AB-BRB-00: Session in Memory of Robert J. Shalek: High Resolution Dosimetry from 2D to 3D to Real-Time 3D

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-02: Methods and Applications of 3D Radiochromic Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-03: Real-Time Volumetric Scintillation Dosimetry for Radiation Therapy

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-04: Cherenkov Imaging for Radiation Therapy Dose Verification On Patients

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

Development of Parallel Image Detection System Using Annular Pupils for Scanning Transmission Electron Microscope

A parallel image detection system using an annular pupil for electron optics were developed to realize an increase in the depth of focus, aberration-free imaging and separation of amplitude and phase images under scanning transmission electron microscopy (STEM). Apertures for annular pupils able to suppress high-energy electron scattering were developed using a focused ion beam (FIB) technique. The annular apertures were designed with outer diameter of oe 40 {mu}m and inner diameter of oe32 {mu}m. A taper angle varying from 20 deg. to 1 deg. was applied to the slits of the annular apertures to suppress the influence of high-energy electron scattering. Each azimuth angle image on scintillator was detected by a multi-anode photomultiplier tube assembly through 40 optical fibers bundled in a ring shape. To focus the image appearing on the scintillator on optical fibers, an optical lens relay system attached with CCD camera was developed. The system enables the taking of 40 images simultaneously from different scattered directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensory, Decision and Control Systems: April to July 1966

The quarter reported here for the NASA contract, and the longer period reported for the Air Force contract, saw the development of two system concepts for the transmission of video data from a remote location to Earth. In the simpler system, a stereoscopic outline together with other data such as reflectance and possibly the texture of objects will be transmitted to Earth. The objects considered are those larger than a predetermined size and within a predetermined range. From the stereoscopic outlines presented to the operator on Earth he will decide what objects he would like pictured in full TV frames and order these transmitted. In the more elaborate system, TV cameras will be carried on a vehicle and the direction in which the vehicle moves will be chosen by an onboard decision computer. Perceptual decisions may also be made to identify objects whose characteristics have been reported to Earth and whose value to the Earth observer has been communicated back to the perceptual computer. The assembly of cameras, perceptual computer, decision computer and vehicle is called a robot. Photosensors for this robot are television cameras, the first models of which have been tested under computer control. A model of both the perceptual computer and the decision computer has been simulated. It consists of 12 modules, each of which makes an initial guess as to what the response to incoming data should be. Each takes the data from all other modules and combines it in a nonlinear fashion with the data coming directly into it to arrive at a mixed guess as to what act should be performed. When 60% of the modules vote 0. 5 probability for one act, that act is performed. Convergence to a satisfactory decision took from 5 to 25 time steps. The model of the frog's retina previously reported is here extended to that part of the brain, called the tectum, where the frog begins to respond to objects detected by the retina.

Control system↗

Cherenkov Light-based Beam Profiling for Ultrarelativistic Electron Beams

We describe a beam profile monitor design based on Cherenkov light emitted from a charged particle beam in an air gap. The main components of the profile monitor are silicon wafers used to reflect Cherenkov light onto a camera lens system. The design allows for measuring large beam sizes, with large photon yield per beam charge and excellent signal linearity with beam charge. Furthermore, the profile monitor signal is independent of the particle energy for ultrarelativistic particles. Different design and parameter considerations are discussed. A Cherenkov light-based profile monitor has been installed at the FACET User Facility at SLAC. Finally, we report on the measured performance of this profile monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ transmission electron microscopy study of oxygen vacancy ordering and dislocation annihilation in undoped and Sm-doped CeO 2 ceramics during redox processes

Ceria (CeO 2 ) based ceramics have been widely used for many applications due to their unique ionic, electronic, and catalytic properties. We report our findings in investigating into the redox processes of undoped and Sm-doped CeO 2 ceramics stimulated by high-energy electron beam irradiation within a transmission electron microscope (TEM). The reduced structure with oxygen vacancy ordering has been identified as the CeO 1.68 (C-Ce 2 O 3+δ ) phase via high-resolution TEM. The reduction of Ce 4+ to Ce 3+ has been monitored by electron energy-loss spectroscopy. The decreased electronic conductivity of the Sm-doped CeO 2 (Sm 0.2 Ce 0.8 O 1.9 , SDC) is revealed by electron holography, as positive electrostatic charges accumulated at the surfaces of SDC grains under electron beam irradiation, but not at CeO 2 grains. The formation of the reduced CeO 1.68 domains corresponds to lattice expansion compared to the CeO 2 matrix. Therefore, the growth of CeO 1.68 nuclei builds up strain inside the matrix, causing annihilation of dislocations inside the grains. By using in-situ high-resolution TEM and a fast OneView camera recording system, we investigated dislocation motion inside both CeO 2 and SDC grains under electron beam irradiation. The dislocations prefer to dissociate into Shockley partials bounded by stacking faults. Then, the partials can easily glide in the {111} planes to reach the grain surfaces. Even the Lomer-Cottrell lock can be swept away by the phase change induced strain field. Our results revealed the high mobility of dislocations inside CeO 2 and SDC grains during their respective redox processes

36 MATERIALS SCIENCE↗

TH-AB-202-06: BEST IN PHYSICS (JOINT IMAGING-THERAPY): A Real-Time Tumor Tracking Using Novel Scatter Imaging Modality During Lung SBRT

Purpose: Compared to traditional radiotherapy techniques, stereotactic body radiation therapy (SBRT) provides more favorable outcomes during the treatment of certain lung tumors. Despite advancements in image guidance, accurate target localization still remains a challenge. In this work, we expand our knowledge of a novel scatter imaging modality in order to develop a real-time tumor localization method using scattered photons from the patient during treatment. Methods: Images of the QUASAR™ Respiratory Motion Phantom were taken by irradiating it on a Varian TrueBeam accelerator. The scattered radiation was detected using a flat panel-based pinhole camera detection system. Two motion settings were investigated: static and dynamic. In the former, the lung tumor was manually shifted between imaging. In the latter, the lung tumor was set to move at a certain frequency and amplitude while the images were acquired continuously for one minute. The accuracy of tumor localization and the irradiation time required to distinguish the lung tumor were studied. Results: The comparison of measured and expected location of the lung tumor during static motion was shown to be under standard deviation (STD) of 0.064 with a mean STD of 0.031cm. The dynamic motion was taken at a rate of 1400 MU/min for one minute and the measured location of the lung tumor was then compared with the QUASAR phantom’s sinusoidal motion pattern and the agreement found to be at an average STD of 0.275cm. The location of the lung tumor was investigated using aggregate images consisting of 1 or 2 frames/image and the change was below STD of 0.30cm. The lung tumor also appeared to be blurrier in images consisting of two frames. Conclusion: Based on our preliminary results real-time image guidance using the scatter imaging modality to localize and track tumors during lung SBRT has the potential to become clinical reality.

60 APPLIED LIFE SCIENCES↗

Cervical SPECT Camera for Parathyroid Imaging

Primary hyperparathyroidism characterized by one or more enlarged parathyroid glands has become one of the most common endocrine diseases in the world affecting about 1 per 1000 in the United States. Standard treatment is highly invasive exploratory neck surgery called Parathyroidectomy. The surgery has a notable mortality rate because of the close proximity to vital structures. The move to minimally invasive parathyroidectomy is hampered by the lack of high resolution pre-surgical imaging techniques that can accurately localize the parathyroid with respect to surrounding structures. We propose to develop a dedicated ultra-high resolution (~ 1 mm) and high sensitivity (10x conventional camera) cervical scintigraphic imaging device. It will be based on a multiple pinhole-camera SPECT system comprising a novel solid state CZT detector that offers the required performance. The overall system will be configured to fit around the neck and comfortably image a patient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NucD-25 Nuclear Diagnostics Development: NIS capability, Maximizing gamma ray dynamic range, (n,γ) measurements for carbon ρR [Slides]

The LANL Neutron Imaging team is preparing for NIS upgrades and novel capabilities with the advent of consistently higher yields at NIF. Novel scintillators, solid-state detectors, multiplexed imaging detectors, upgraded data acquisition systems, and camera testing are all areas in need of experimental study to further develop imaging capabilities and dynamic range at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Nimbus satellite system

Nimbus weather satellite as laboratory for sensors collecting data for global weather system, describing launching, attitude control systems and cameras

Weiland, S.↗

Technique and computer program for calculating photographic film density variations

Film density data that have been digitalized and recorded in binary coded decimal (BCD) format are converted into a number representing the film density difference between the unexposed film border and any point on a photograph by program CONVERT. The difference AVERAGE, the BCD number representing the unexposed film area and the BCD number of a specific data point is calculated and then multiplied by three constants to produce the desired film density difference. The angle off the principal axis of the lens is computed for each data point in order that a correction factor be applied to compensate for atmospheric backscattering differences and light intensity fall-off, inherent in the camera lens system in use. The program is capable of plotting the calculated density differences. The percentage of points in specific density ranges can also be computed.

Ohlhorst, C. W.↗

Viking

The Viking program, its characteristics, goals, and investigations are described. The program consists of launching two spacecraft to Mars in 1975 to soft-land on the surface and test for signs of life. Topics discussed include the launch, the journey through space, tracking, Mars orbit and landing, experiments on the search for life, imaging systems, lander camera, water detection experiments, thermal mapping, and a possible weather station on Mars.

Source record↗

Experimental measurements of the rotating frequencies and mode shapes of a full scale helicopter rotor in a vacuum and correlations with calculated results

This paper presents results of an experimental program conducted to obtain data which can be used for correlations of rotor blade dynamic analyses. Measurements were made of the rotating frequencies and mode shapes of a representative full-scale, two-bladed helicopter rotor in a vacuum. The blades were cantilevered to the hub. Mode shape data were obtained optically using a system of cameras developed specifically for this purpose. Excitation of the rotor was provided by vertical oscillatory motion of the hub. To compare experimental and analytical results, correlations of some experimental measurements with calculations from an existing blade modes computer program based on a Holzer-Myklestad procedure are presented, and the differences between the results are discussed. The experimental and analytical natural frequencies were generally in good agreement as were the principal components of the modal deflections for the flap and lag modes. The torsion mode shape indicated disagreement between the measured and calculated results in regard to the amount of flap and lag motions present in this mode, while the spanwise variations of the measured and calculated torsional components were in agreement.

Lee, B. L.↗