Search NASA⌕ Search

SEARCH · Search NASA

Results for “cleaning methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Protective conversion coating on mixed-metal substrates and methods thereof

Mixed-metal automotive vehicle bodies-in-white comprising ferrous metal surfaces, zinc surfaces, aluminum alloy surfaces, and magnesium alloy surfaces are cleaned and immersed in an aqueous bath comprising an adhesion promoter and an aqueous electrocoat bath (the adhesion promoter may be in the electrocoat bath. The adhesion promoter, which may be a cerium salt, is selected to react with each metal in the body surfaces to form an oxide layer that provides corrosion resistance for the surface and adherence for the deposited polymeric paint coating. The body is cathodic in the electrocoat deposition.

36 MATERIALS SCIENCE↗

Photocatalytic Nanofiltration Membranes with Self‐Cleaning Property for Wastewater Treatment

Membrane fouling is one of the most severe problems restricting membrane separation technology for wastewater treatment. This work reports a photocatalytic nanofiltration membrane (NFM) with self‐cleaning property fabricated using a facile biomimetic mineralization process. In this strategy, a polydopamine (PDA)/polyethyleneimine (PEI) intermediate layer is fabricated on an ultrafiltration membrane via a co‐deposition method followed by mineralization of a photocatalytic layer consisting of β‐FeOOH nanorods. The PDA–PEI layer acts both as a nanofiltration selective layer and an intermediate layer for anchoring the β‐FeOOH nanorods via strong coordination complexes between Fe 3+ and catechol groups. In visible light, the β‐FeOOH layer exhibits efficient photocatalytic activity for degrading dyes through the photo‐Fenton reaction in the presence of hydrogen peroxide, endowing the NFM concurrently with effective nanofiltration performance and self‐cleaning capability. Moreover, the mineralized NFMs exhibit satisfactory stability under simultaneous filtration and photocatalysis processing, showing great potential in advanced wastewater treatment.

Lv, Yan↗

Development of Statistical Process Control Methodology for an Environmentally Compliant Surface Cleaning Process in a Bonding Laboratory

Bonding labs at both MSFC and the northern Utah production plant prepare bond test specimens which simulate or witness the production of NASA's Reusable Solid Rocket Motor (RSRM). The current process for preparing the bonding surfaces employs 1,1,1-trichloroethane vapor degreasing, which simulates the current RSRM process. Government regulations (e.g., the 1990 Amendments to the Clean Air Act) have mandated a production phase-out of a number of ozone depleting compounds (ODC) including 1,1,1-trichloroethane. In order to comply with these regulations, the RSRM Program is qualifying a spray-in-air (SIA) precision cleaning process using Brulin 1990, an aqueous blend of surfactants. Accordingly, surface preparation prior to bonding process simulation test specimens must reflect the new production cleaning process. The Bonding Lab Statistical Process Control (SPC) program monitors the progress of the lab and its capabilities, as well as certifies the bonding technicians, by periodically preparing D6AC steel tensile adhesion panels with EA-91 3NA epoxy adhesive using a standardized process. SPC methods are then used to ensure the process is statistically in control, thus producing reliable data for bonding studies, and identify any problems which might develop. Since the specimen cleaning process is being changed, new SPC limits must be established. This report summarizes side-by-side testing of D6AC steel tensile adhesion witness panels and tapered double cantilevered beams (TDCBs) using both the current baseline vapor degreasing process and a lab-scale spray-in-air process. A Proceco 26 inches Typhoon dishwasher cleaned both tensile adhesion witness panels and TDCBs in a process which simulates the new production process. The tests were performed six times during 1995, subsequent statistical analysis of the data established new upper control limits (UCL) and lower control limits (LCL). The data also demonstrated that the new process was equivalent to the vapor degreasing process.

Hutchens, Dale E.↗

TESTING OF THE DUAL ROTARY FILTER SYSTEM

The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek rotary microfilter (RMF) units to determine the behavior of a multiple filter system. Both units were successfully controlled by a control scheme written in DELTA-V architecture by Savannah River Remediation (SRR) Process Control Engineering personnel. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The installation configuration originally proposed by the Small Colum Ion Exchange (SCIX) project of independent filter and motor mountings may be susceptible to vibration. Significant stiffening of the filter and motor mounts was required to minimize the vibration. Alignment of the motor to the filter was a challenge in this test configuration. The deployment configuration must be easy to manipulate and allow for fine adjustment. An analysis of the vibration signature of the test system identified critical speeds. Whether it corresponds to the resonance frequency of a rotor radial vibration mode that was excited by rotor unbalance is uncertain based upon the measurements. A relative motion series should be completed on the filter with the final shaft configuration to determine if the resonances exist in the final filter design. The instrumentation selected for deployment, including the concentrate discharge control valve and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual RMF system. The one area of concern with the instrumentation was the condition resulting when the filtrate flow meter operated with less than three gpm. This low flow was at the lower range of performance for the flow meter. This should not be an issue in deployment where the desired flow rate will be within the normal operating range of the meter. Testing demonstrated that the use of a flexible line for the filtrate discharge is highly desired at the outlet of the rotary union to transition to the system piping. Isolating the vibration from the rotary union will significantly improve the lifetime of the seals. Methods to monitor and isolate individual filters should be considered during deployment. The ability to diagnose issues and isolate individual filters would allow isolation prior to failure. Thus, filters may be cleaned or repaired instead of requiring complete replacement if the condition were to continue unnoticed. Isolating the filtrate line of each filter during startup will minimize the premature buildup of solids on the filter disks. Several tests have shown that the method of filter startup can improve performance lifetime of the filters. The installation must factor in an air inlet for the draining of a filter that does not involve a reverse flow through the filter disks. The reverse flow may cause deformation of the disks or may damage other components of the filters themselves.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mask Free OLED Fabrication Process for Non-Tunable and Tunable White OLED Panels

In this program we demonstrated a method for mask free fabrication of OLEDs. Conventional OLEDs use at least 2 shadowmasks during the fabrication process to define the deposition pattern for the organic layers and for the cathode layer. Although effective, the use of masks requires mask handling and mask change equipment which increases the cost of the OLED deposition system. New sets of masks are required for every new product design, and the mask sets require frequent cleaning as organic material builds up on the masks over time and can be a source of particle defects resulting in yield loss. The method investigated in this program uses laser removal of organic material to pattern the organic layers and define a moisture impermeable seal region. This method is digital and can be applied to any new panel design, avoiding the costs of new masks sets and associated yield loss. In addition, we developed a platform technology for producing white color tunable or dim-to-warm white OLEDs and demonstrated patterning of tunable white OLEDs using the low-cost mask free fabrication process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Construction of a Shallow Underground Low-background Detector for a CTBT Radionuclide Laboratory

The International Monitoring System (IMS) is a verification component of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), and in addition to a series of radionuclide monitoring stations, contains sixteen radionuclide laboratories capable of verification of radionuclide station measurements. This paper presents an overview of a new commercially obtained low-background detector system for radionuclide aerosol measurements recently installed in a shallow (>30 meters water equivalent) underground clean-room facility at Pacific Northwest National Laboratory. Specifics such as low-background shielding materials, active shielding methods, and improvements in sensitivity to IMS isotopes will be covered.

Forrester, Joel B.↗

Fundamental Issues Identified for Thermodynamic Description of Molten Salt Systems

Thermodynamic modeling of the molten salt systems is critical in the design of advanced nuclear power plants, materials recycling, and many other important clean energy applications. As one of the most capable computational thermodynamic approaches, the CALPHAD (Calculation of Phase Diagrams) method has been widely used for multicomponent thermodynamic database development and further support more physics-based modeling. Although considerable CALPHAD modeling efforts for molten salt systems have been made, we found that no evaluation has been performed regarding the unary thermodynamic models for the molten salt systems despite the fact that more than one pure substance database is available for the CALPHAD modeling. Therefore, the thermodynamic descriptions of the pure salts should be critically evaluated to ensure a high-fidelity molten salt thermodynamic database. In this work, we comprehensively analyzed some selected molten salts using different available thermodynamic descriptions from two databases as an example. One is the SSUB database released by the SGTE (Scientific Group Thermodata Europe), and the other is the FactPS database from the FactSage. Finally, the significant discrepancies observed in the thermodynamic description between the existing CALPHAD pure substance databases and experiments call for an urgent effort to improve.

42 ENGINEERING↗

Nondestructive neutron imaging diagnosis of acidic gas reduction catalyst after 400-Hour operation in natural gas furnace

Residential natural gas furnaces are the primary space-heating devices in US homes, leading to substantial environmental impact caused by the acidic components in the furnace combustion gases. Here, to experimentally demonstrate acidic gas reduction in a furnace, a monolithic catalyst was fabricated and was called the AGR. A commercially-available condensing furnace was retrofitted with the AGR, and a 400-hour reliability and durability test was conducted. The results showed that the AGR significantly reduced acidic gases in the flue gas and produced condensate with neutral pH. Challenges were also revealed: inappropriate condensate drainage caused incomplete combustion and amorphous carbon deposits. To nondestructively survey the internal state of the AGR, neutron computed tomography (NCT) was employed to produce spatially resolved 2D and 3D representations of the 2-L, aged AGR component. The NCT results confirm the integrity of the AGR component, which consists of two blocks, without deformation or damage to AGR channels. The distribution of the particle accumulation in the middle of the top block was visibly heavier than the entrance and exit of the top block. The representative cross-section views revealed significant aggregation in the central region but not at the rim. The spatially resolved details provide in-depth diagnosis, evaluation, and understanding of the AGR. The insights can enable new AGR designs that realize a uniform and self-cleaning flow pattern, alleviate significant particle aggregation, and thus enhance AGR-enabled furnace performance. The neutron imaging method demonstrates the good potential that can diagnose faults and improve the design, optimization, and production processes of novel catalysts and other components or systems with heavy metal shell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facile fabrication of 2D material multilayers and vdW heterostructures with multimodal microscopy and AFM characterization

Reliable transfer processes that enable manipulation of two-dimensional (2D) materials, e.g., transition metal dichalcogenides (TMDCs) and MXenes, from one substrate to another has been a necessity for successful device fabrication. Here, with both mechanical exfoliation and chemical vapor deposition (CVD) widely used, a versatile, clean, deterministic, and yet simple transfer technique is highly needed. To address such need, we developed a transfer method that takes advantage of wettability contrast between interfaces without the use of sacrificial layers or chemical processes. More importantly, a setup was developed to carry out this transfer method with high sample selectivity and fine control of the position and orientation of transferred TMDC crystals, a feature required for fabrication of the devices based on vertical 2D heterostructures. Using both exfoliated and CVD grown materials and subsequent atomic force microscopy (AFM), photoluminescence (PL), confocal Raman and tip enhanced Raman spectroscopy (TERS) characterization, we ascertained the quality of interfaces resulting from the transfer process while preserving excellent 2D material integrity. PL and TERS maps revealed nanometer-scale heterogeneities in the interfaces of fabricated heterostructures, which should enable further perfection of the transfer technique. TERS/TEPL information were employed to identify areas suitable for nanodevice fabrication, making the reported transfer and characterization methods ideal for making high quality assembly of 2D heterostructure more accessible, which should facilitate exploration of vertical 2D heterostructures for applications in electronics, batteries, solar cells, and twistronics.

2D material transfer↗

Optimization for Peptide Sample Preparation for Urine Peptidomics

Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides and the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.

biomarker↗

Thin Film Characterization on Cu/SnAg Solder Interface for 3D Packaging Technologies

Copper is a commonly used interconnect metal in microelectronic interconnects due to its exceptional electrical and thermal properties. Particularly in applications of the 2.5 and 3D integration, Cu is utilized in through-silicon-vias (TSVs) and flip chip interconnects between microelectronic chips for providing miniaturization, lower power and higher performance than current 2D packaging approaches. Furthermore, SnAg capped Cu pillars are a common high-density interconnect technology for flip chip bonding. For these interconnects, specific properties of the Cu surface, such as roughness and cleanliness, are an important factor in the process to ensure quality solder bumps. During electroplating, tight processing parameters must be met so that defects are avoided, and high bump uniformity is achieved. An understanding of the interactions at the solder and Cu pillar interface is needed, based on the electroplating parameters, to determine the best method for populating solder on the wafer surface. In this study, surface treatment techniques such as oxygen plasma cleaning were performed on the Cu surfaces and the SnAg plating chemistry for depositing the solder were evaluated through hull cell testing to qualitatively determine the range of current densities to investigate. It was observed that current density while plating played a large role in solder bump deposition morphology. At the higher current densities greater than 60 mA/cm 2 , bump height non-uniformity and dendritic growth are observed and at lower current densities, less than or equal to 60 mA/cm 2 , uniform, continuous bump height occurred.

36 MATERIALS SCIENCE↗

Gear Test Assembly – Report Experimental Testing and Gear Analysis (FY2021 Midyear Report)

The Gear Test Assembly (GTA) has completed three experimental campaigns at the Mechanisms Engineering Test Loop (METL) facility. The most recent campaign tested Inconel 718 spur gears, tapered roller bearings of 52100 bearing steel with no heat treatment, and a lantern ring shaft seal with spring-loaded fasteners. Testing was performed in Test Vessel 1 (TV1) with 250°C sodium that had an oxide concentration of <10ppm. Testing began in February 2021 and was ended in March 2021 when a thrust bearing assembly failed, requiring shutdown and maintenance. The third experimental campaign completed 1,568 simulated fuel assembly maneuvers before the thrust bearing failure. The GTA was removed from TV1 and cleaned in the Carbonation System. The GTA is currently being prepared for the next experimental campaign. Nondestructive examination methods have been developed at Argonne to monitor the health of the GTA spur gears. Eddy current testing (ECT) and ultrasonic testing (UT) were performed prior to sodium testing and after each experimental campaign. The NDE has shown that the primary damage mechanism is mechanical wear on the gear tooth surface. Several larger nicks are observable on the gear faces, with additional large nicks present on the edges of the gear teeth. While this damage is observable, the overall health of the gears is adequate for more in-sodium testing. A total of 12,752 simulated fuel assembly maneuvers have been completed using this set of gears.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molten Salt Reactor Sourdough Refueling and Waste Management Strategy

This paper presents a new approach to the spent nuclear fuel (SNF) problem, which is uniquely enabled by a liquid fuel form, specifically as in the case of molten salt reactor (MSR) systems. Managing the SNF problem is critical for public acceptance of nuclear power as a climate change solution. An MSR can be refueled while operating by adding more fresh fuel salt, which grows the in-core fuel salt volume. This growth will eventually double the size of the original fuel salt, allowing to start another core with this excess fuel so long as the daughter reactor is of the same design and there is sufficient excess fuel. This study explores how such a “sourdough” strategy would work in MSRs and provides an initial calculation methodology to find the correct refueling rates to match the desired growth curve of power generation. Higher uranium enrichment levels of the refuel salt result in lower refueling rates and thus a longer doubling time. As a result, the refuel salt uranium enrichment can be tailored to match a postulated clean power generation capacity expansion. This approach allows postponing the spent nuclear fuel disposal issue using the sourdough method. Along with the MSR fuel’s unique properties, it suggests a new path towards managing nuclear waste until long-term solutions become economically viable.

Wheeler, Alexander M.↗

Heat pipe manufacturing study

Heat pipe manufacturing methods are examined with the goal of establishing cost effective procedures that will ultimately result in cheaper more reliable heat pipes. Those methods which are commonly used by all heat pipe manufacturers have been considered, including: (1) envelope and wick cleaning, (2) end closure and welding, (3) mechanical verification, (4) evacuation and charging, (5) working fluid purity, and (6) charge tube pinch off. The study is limited to moderate temperature aluminum and stainless steel heat pipes with ammonia, Freon-21 and methanol working fluids. Review and evaluation of available manufacturers techniques and procedures together with the results of specific manufacturing oriented tests have yielded a set of recommended cost-effective specifications which can be used by all manufacturers.

Edelstein, F.↗

Characterization of the tribological coating composition 77 wt % CaF2 - 23 wt % Li F fused to IN-750 alloy

A coating composed of 77 wt % CaF2 - 23 wt % LiF fused on IN-750 nickel-based alloy was studied using SEM, XRD, EDX, and optical microscopic methods. The surfaces examined were the as-fused coating with no subsequent treatment, the coating after ultrasonic cleaning in water, and the uncoated polished and etched metal. It was found that the coating reacts during fusion with Ti and Nb rich inclusions in the alloy. Numerous small rectangular crystallites of Ca(Ti,Nb) oxide are formed beneath an overlay of fused fluoride composition. These crystallines are stubby and appear to be embedded in the metal substrate surface. It is known from previous studies that this coating-alloy system has good tribological properties in extreme conditions, such as liquid fluorine. It has been concluded from the present study that the short firmly embedded crystalline protuberances contribute to the coating adherence and thereby to enhanced coating wear life.

Deadmore, D. L.↗

Numerical Modeling of Drying Residual RP-1 in Rocket Engines

When a Rocket Engine shuts down under a fuel rich environment, a significant amount of unburned RP-1 is trapped In the engine. It is necessary to clean the residual RP-1 prior to subsequent firing to avoid any explosion due to detonation. The conventional method is to dry RP-1 with inert gas such as Nitrogen or Helium. It is difficult to estimate the drying time unless the engine is adequately equipped with instruments to measure the trace of RP-1 during the drying process. Such instrumentation in flight hardware is often impractical and costly. On the other hand numerical modeling of the drying process can provide a good insight for a satisfactory operation of the process. A numerical model can provide answer to questions such as a) how long it takes to dry, b) which fluid is a better dryer for RP-1, c) how to reduce drying time etc. The purpose of the present paper is to describe a numerical model of drying RP-1 trapped in a cavity with flowing nitrogen or helium. The numerical model assumes one dimensional flow of drying fluid in contact with liquid pool of RP-1. An evaporative mass transfer takes place across the contact surface.

Majumdar, Alok↗

Current Space Station Experiments Investigating Component Level Electronics Repair

The Soldering in a Reduced Gravity Experiment (SoRGE) and Component Repair Experiment (CRE)-1 are tests performed on the International Space Station to determine the techniques, tools, and training necessary to allow future crews to perform manual electronics repairs at the component level. SoRGE provides information on the formation and internal structure of through-hole solder joints, illustrating the challenges and implications of soldering in reduced gravity. SoRGE showed a significant increase in internal void defects for joints formed in low gravity compared to normal gravity. Methods for mitigating these void defects were evaluated using a modified soldering process. CRE-1 demonstrated the removal, cleaning, and replacement of electronics components by manual means on functional circuit boards. The majority of components successful passed a post-repair functional test demonstrating the feasibility of component-level repair within the confines of a spacecraft. Together, these tasks provide information to recommend material and tool improvements, training improvements, and future work to help enable electronics repairs in future space missions.

Easton, John W.↗

Copoly(imide siloxane) Abhesive Materials with Varied Siloxane Oligomer Length

In this work, low surface energy copoly(imide siloxane)s were synthesized with various siloxane segment lengths. Characterization of these materials revealed that domain formation of the low surface energy component within the matrix was more prevalent for longer siloxane segments as indicated by increased opacity, decreased mechanical properties, and variation of the Tg. Incorporation of siloxanes lowered the polymer s surface energy as indicated by water contact angle values. Topographical modification of these materials by laser ablation patterning further reduced the surface energy, even generating superhydrophobic surfaces. Combined, the contact angle data and particle adhesion testing indicated that copoly(imide siloxane) materials may provide greater mitigation to particulate adhesion than polyimide materials alone. These enhanced surface properties for abhesive applications did result in a reduction of the tensile moduli of the copolymers. It is possible that lower siloxane loading levels would result in retention of the mechanical properties of the polyimide while still affording abhesive surface properties. This hypothesis is currently being investigated. Laser ablation patterning offers further reduction in particle retention as the available surface area for particle adhesion is reduced. Pattern variation and size dependencies are currently being evaluated. For the purposes of lunar dust adhesion mitigation, it is likely that this approach, termed passive due to the lack of input from an external energy source, would not be sufficient to mitigate surface contamination or clean contaminated surfaces for some lunar applications. It is feasible to combine these materials with active mitigation strategies - methods that utilize input from external energy sources - would broaden the applicability of such materials for abhesive purposes. Collaborative efforts along these lines have been initiated with researchers at NASA Kennedy Space Center where experiments are being conducted involving a series of embedded electrodes within polymeric matrices.

Wohl, Christoper J.↗