Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Mathematical Model of Cold Cap—Preliminary One-Dimensional Model Development

The ultimate goal of batch-melting studies, laboratory-scale, large-scale, or mathematical modeling is to increase the rate of glass processing in an energy-efficient manner. Mathematical models are not merely an intermediate step between laboratory-scale and large-scale studies, but are also an important tool for assessing the responses of melters to vast combinations of process parameters. In the simplest melting situation considered in this study, a cold cap of uniform thickness rests on a pool of molten glass from which it receives a steady uniform heat flux. Thus, as the feed-to-glass conversion proceeds, the temperature, velocity, and extent of feed reactions are functions of the position along the vertical coordinate, and these functions do not vary with time. This model is used for the sensitivity analyses on the effects of key parameters on the cold-cap behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2010 Radiological Monitoring Results Associated with the Advance Test Reactor Complex Cold Waste Pond

This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

2010 radiological monitoring report↗

OTEC Advanced Composite Cold Water Pipe: Final Technical Report

Ocean Thermal Energy Conversion can exploit natural temperature gradients in the oceans to generate usable forms of energy (for example, cost-competitive baseload electricity in tropical regions such as Hawaii) free from fossil fuel consumption and global warming emissions.The No.1 acknowledged challenge of constructing an OTEC plant is the Cold Water Pipe (CWP), which draws cold water from 1000m depths up to the surface, to serve as the coolant for the OTEC Rankine cycle. For a commercial-scale plant, the CWP is on the order of 10m in diameter.This report describes work done by LMSSC developing the CWP for LM MS2 New Ventures emerging OTEC business. The work started in early 2008 deciding on the minimum-cost CWP architecture, materials, and fabrication process. In order to eliminate what in previous OTEC work had been a very large assembly/deployment risk, we took the innovative approach of building an integral CWP directly from theOTEC platform and down into the water. During the latter half of 2008, we proceeded to a successful small-scale Proof-of-Principles validation of the new fabrication process, at the Engineering Development Lab in Sunnyvale. During 2009-10, under the Cooperative Agreement with the US Dept. of Energy, we have now successfully validated key elements of the process and apparatus at a 4m diameter scale suitable for a future OTEC Pilot Plant. The validations include: (1) Assembly of sandwich core rings from pre-pultruded hollow 'planks,' holding final dimensions accurately; (2) Machine-based dispensing of overlapping strips of thick fiberglass fabric to form the lengthwise-continuous face sheets, holding accurate overlap dimensions; (3) Initial testing of the fabric architecture, showing that the overlap splices develop adequate mechanical strength (work done under a parallel US Naval Facilities Command program); and (4) Successful resin infusion/cure of 4m diameter workpieces, obtaining full wet-out and a non-discernable knitline between successive stepwise infusions.

13 HYDRO ENERGY↗

2011 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

This report summarizes radiological monitoring performed of the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

2011↗

Generalized Test Plan for the Vitrification of Simulated High-Level-Waste Calcine in the Idaho National Laboratory‘s Bench-Scale Cold Crucible Induction Melter

This Preliminary Idaho National Laboratory (INL) Test Plan outlines the chronological steps required to initially evaluate the validity of vitrifying INL surrogate (cold) High-Level-Waste (HLW) solid particulate calcine in INL's Cold Crucible Induction Melter (CCIM). Its documentation and publication satisfies interim milestone WP-413-INL-01 of the DOE-EM (via the Office of River Protection) sponsored work package, WP 4.1.3, entitled 'Improved Vitrification' The primary goal of the proposed CCIM testing is to initiate efforts to identify an efficient and effective back-up and risk adverse technology for treating the actual HLW calcine stored at the INL. The calcine's treatment must be completed by 2035 as dictated by a State of Idaho Consent Order. A final report on this surrogate/calcine test in the CCIM will be issued in May 2012-pending next fiscal year funding In particular the plan provides; (1) distinct test objectives, (2) a description of the purpose and scope of planned university contracted pre-screening tests required to optimize the CCIM glass/surrogate calcine formulation, (3) a listing of necessary CCIM equipment modifications and corresponding work control document changes necessary to feed a solid particulate to the CCIM, (4) a description of the class of calcine that will be represented by the surrogate, and (5) a tentative tabulation of the anticipated CCIM testing conditions, testing parameters, sampling requirements and analytical tests. Key FY -11 milestones associated with this CCIM testing effort are also provided. The CCIM test run is scheduled to be conducted in February of 2012 and will involve testing with a surrogate HLW calcine representative of only 13% of the 4,000 m3 of 'hot' calcine residing in 6 INL Bin Sets. The remaining classes of calcine will have to be eventually tested in the CCIM if an operational scale CCIM is to be a feasible option for the actual INL HLW calcine. This remaining calcine's make-up is HLW containing relatively high concentrations of zirconium and aluminum, representative of the cladding material of the reprocessed fuel that generated the calcine. A separate study to define the CCIM testing needs of these other calcine classifications in currently being prepared under a separate work package (WP-0) and will be provided as a milestone report at the end of this fiscal year.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Market Assessment for Cold Climate Heat Pumps

Cold climate heat pump (HP) technology is relevant to a substantial portion of the U.S. population, especially with more than one-third of U.S. housing stock concentrated in colder regions of the country and another 31% in the mixed-humid climate region. Specifically, it is estimated that in 2010 almost 1.37 million heating equipment units were shipped to the cold/very cold climate regions and that 1.41 million were shipped to the nation s mixed-humid region.

02 PETROLEUM↗

Idaho National Laboratory Water Conservation Project Evaluation—Impact of Reducing Discharge to the Advanced Test Reactor Cold Waste Pond on Sulfate Concentrations in the Snake River Plain Aquifer

In support of the water conservation goals of the U.S. Department of Energy’s Strategic Sustainability Performance Plan, a number of water conservation projects have been proposed that would reduce the volume of wastewater currently discharged to the Advanced Test Reactor Complex’s Cold Waste Pond at the Idaho National Laboratory. This evaluation provides an approximation of the potential impact to groundwater quality from reducing raw or “clean” water discharges to the Cold Waste Pond and concentrating chemicals (e.g., sulfate) in the effluent.

99 GENERAL AND MISCELLANEOUS↗

Development of A High Performance Cold Climate Heat Pump

The primary goals of the proposed project were to develop, test, and evaluate a high performance and cost-effective vapor compression air-source heat pump for use in cold climate regions. Vapor compression heat pumps are a proven technology, and have been used for many years to meet heating requirements for buildings in residential, commercial, and industrial applications. However, in climate regions that experience very low outdoor ambient temperatures both the heating capacity and coefficient of performance (COP) of traditional air-source vapor compression heat pumps drops dramatically with a decrease in the outdoor air temperature. The efficiency of heat pumping equipment has improved substantially over the past 20 years; however, the efficiencies of the highest rated equipment on the market are approaching practical limits that cannot be surpassed without modifications to the basic cycle and possibly the use of additional hardware. In this report, three technologies to improve the efficiency of vapor compression systems are described. These are a) vapor injected compression, b) oil flooded compression and c) hybrid flow control of the evaporator. Compressor prototypes for both, oil flooded and vapor injected compression were developed by Emerson Climate Technologies. For the oil flooded compressor, the oil injection port location was optimized and an internal oil separator was added using several design iterations. After initial testing at Emerson Climate Technologies, further testing was done at Purdue University, and compressor models were developed. These models were then integrated into a system model to determine the achievable improvement of seasonal energy efficiency (SEER) for Minneapolis (Minnesota) climate. For the oil flooded compression, a 34% improvement in seasonal energy efficiency was found while a 21% improvement in seasonal energy efficiency ratio was found for the vapor injected compression. It was found that one benefit of both tested compression technologies is a lower discharge temperature, which allows for continued operation at lower ambient temperatures. A bin analysis of the vapor injected prototype cold climate heat pump predicts a 6% improvement in HSPF for Minneapolis. This improvement is mainly a result of the increased capacity of the system for active vapor injection. For the oil flooded system, a slightly larger performance improvement is predicted, in this case mostly caused by an increase in heating COP. Based on an economic analysis of these results, the maximum additional cost of the system changes, for the Minneapolis location, are $\$430$ for the vapor injected system and $\$391$ for the oil flooded system. These estimates assume that a 3-year simple payback period is accepted by the customer. For the hybrid flow control of evaporators, a new type of balancing valve was developed together with Emerson Climate technologies to reduce the cost of the control scheme. In contrast to conventional stepper motor valves, this valve requires less cables and can be driven by a cheaper output circuit on the control board. The correct valve size was determined in a dedicated test stand in several design iterations. The performance benefits of the hybrid control of the evaporator coil were determined for clean coil conditions as well as with partial blockage of the air inlet grille and under frosting conditions. For clean coil conditions, the benefits in terms of COP and capacity are negligible. However, significant benefits were noted for severely air-maldistributed operating conditions. For the H2-test, the maximum COP improvement of 17% along with a capacity improvement of nearly 40% was observed. Overall, the hybrid control scheme leads to a significant amount of performance improvement, if the air inlet conditions to the evaporator are maldistributed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-efficiency Commercial Cold Climate Heat Pump

United Technologies Research Center (UTRC) proposed in 2012 to design, develop and demonstrate an air-source 10TR high-efficiency commercial cold climate heat pump (CCCHP). The proposed heat pump would be scalable beyond 40TR, cost effective with a simple payback of < 3 years upon commercialization and would reduce annual electricity use for building space heating in cold climates by at least 20%. This would represent an annual savings of $2.3 billion and a 20% displacement of total greenhouse gases generated upon full commercialization. The primary objective was to develop a highly integrated system that shall meet or exceed DOE capacity and efficiency targets at key conditions and is scalable, cost-effective and simple relative to the state-of-the-art. Specifically, the goal of the project was to design, develop and demonstrate a CCCHP that exceeds DOE capacity degradation requirements at +17F and -13F conditions (0 and <15% degradation vs. 10 and 25% DOE requirements, respectively) while meeting or exceeding DOE capacity and system efficiency requirements at all other conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data product development for cold cloud and precipitation process analysis/Snow regime classifications from the NSA snow product

This grant funded work focused first on developing a data product for cold-cloud precipitation and second, under a continuation, on examining distinct snowfall regimes occurring at the North Slope Alaska (NSA) facility. The overarching goal under the first phase was to provide a data product that quantifies the vertically- and temporally-resolved properties of cold, precipitating clouds and that will enable future analyses of the processes that control their formation and evolution. The data product derives from observations at the NSA Utqiagvik (BRW) and Oliktok Point (OLI) sites, its algorithm utilizing radar observations supplemented with in situ and other collocated remote sensing measurements to constrain an optimal estimation retrieval.

54 ENVIRONMENTAL SCIENCES↗

Cold Spray for Mitigation and Repair of Spent Nuclear Fuel Dry Storage Canisters

The purpose of this work is to investigate the use of cold spray for repair and mitigation of chloride-induced stress corrosion cracking (CISCC) in dry cask storage system (DCSS) canisters to ensure their integrity far beyond their original license period. This report provides a viability analysis of cold spray for repair and mitigation of CISCC in DCSS canisters to extend canister life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation Hardened Foam Cold Test Plan - Phase II: Foam Characterization Testing and Environmental Chamber Testing of FoamBag Fixative Foam

This document outlines the Phase II test objectives and implementation plan for a down-select foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of a polyurethane resin foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed at FIU and SRNL test and lab facilities. Results from the cold tests will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the area and transported to a designated disposal facility. Phase I testing was previously conducted using Hilti CP620 fixative foam. Results from Phase I testing indicate Hilti CP-620 fixative foam is incompatible with SRS site hot taps as an effective foam delivery method into Hastelloy C-22 piping. Phase II testing will be conducted using FoamBag TM fixative foam as an alternative fixative foam option. Phase II testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of FoamBag TM in Hastelloy C-22 piping, (2) evaluation of the adhesion of FoamBag TM in piping under various moisture conditions, (3) determination of the heat profile of FoamBag TM during curing, (4) determination of the internal pipe pressure after FoamBag TM deployment and curing, (5) conduct a leak test to determine if FoamBag TM is effective at creating a full seal within piping, (6) headspace testing of FoamBag TM to determine if there are any associated off-gas hazards during FoamBag TM curing, (7) conduct environmental chamber testing of FoamBag TM to understand how environmental parameters impacts FoamBag TM curing, and (8) conduct fire testing to evaluate FoamBag TM fire retardant characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cold Plasma Measurements

We have continued the simulation campaign in support of our ongoing magnetospheric cold plasma research project. This project aims to develop the next-generation particle instruments to measure the properties of the cold particle populations in the Earth’s magnetosphere. For this purpose, simulations have been performed with a Particle-In-Cell (PIC) code called the Curvilinear PIC (CPIC). The code is formulated in curvilinear geometry and couples the standard PIC algorithm with algorithms for the generation and adaptation of the underlaying computational mesh. It conforms to complex objects like spacecraft and it can place more grid points in regions where higher resolution is needed. The code also features a scalable solver based on the multigrid algorithm and it is fully parallelized via domain decomposition and MPI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PEM Fuel Cell Freeze Durability and Cold Start Project

UTC has taken advantage of the unique water management opportunities inherent in micro-porous bipolar-plates to improve the cold-start performance of its polymer electrolyte fuel cells (PEFC). Diagnostic experiments were used to determine the limiting factors in micro-porous plate PEFC freeze performance and the causes of any performance decay. Alternative cell materials were evaluated for their freeze performance. Freeze-thaw cycling was also performed to determine micro-porous plate PEFC survivability. Data from these experiments has formed the basis for continuing development of advanced materials capable of supporting DOE's cold-start and durability objectives.

08 HYDROGEN↗

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates

BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates - Bolingbrook, IL 60440 BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates - Friendswood, TX 77546 To understand the long-term moisture performance of unvented roof assemblies with fibrous insulation, the U.S. Department of Energy's Building America team Building Science Corporation built and monitored test roofs in two climates: a cold-climate test house in Bolingbrook, Illinois (Chicago area; zone 5A), and a hot-humid test house in Friendswood, Texas (Houston area, zone 2A). The Chicago-area test bed had seven parallel experimental rafter bays. The assemblies included a control vented compact (cathedral) roof, a dense-pack cellulose unvented roof, and an unvented roof with a "diffusion vent" (a strip of vapor-permeable gypsum sheathing at the ridge to allow drying). The interior finish was gypsum wallboard (GWB) with latex paint. The other four bays were top vent roof assemblies, which have a polypropylene breather mesh between the roof sheathing and the asphalt shingles to allow ventilation drying of the assembly from underneath the vapor-impermeable shingles. Two of the four "top vent" roofs were fiberglass batt and two were dense-pack cellulose roofs with either interior GWB or open to the interior. Wintertime moisture-related failure was accelerated by providing interior humidification (22.2 degree C [72 degree F]/50% relative humidity [RH]), which is known to be an extreme interior loading). Data were captured over 8 months, including a winter and the following spring and early summer.

Array↗

The Performance House: A Cold Climate Challenge Home - Old Greenwich

Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, the Consortium for Advanced Residential Buildings partnered with Preferred Builders Inc. on a high performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 Performance House were based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the Performance House were not cutting-edge, but simply best practices practiced. The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 International Energy Conservation Code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. The Performance House demonstrates how a home can be designed and constructed in the cold climate zone to be energy efficient, low maintenance, sustainable, and comfortable. Lower price premiums are still needed for solutions such as ccSPF and light-emitting diodes, but this is anticipated as their market demand increases. For a solution package of this level to become commercially viable, there is still a need to improve the home appraisal process to better value the multiple benefits of a solution package of this type over standard builder practices.

accessibility↗

NorthernSTAR 1.5-Story Demonstration House of Cold Climate Solutions for Affordable Housing

This is a NorthernSTAR renovation project for Urban Homeworks incorporating installation of a combination space and water heater, Overcoat insulation retrofit on the roof, and Excavationless foundation insulation retrofit. STRUCTURE - 1401 North 16th Ave Minneapolis, MN 55411 Various groups from the affordable housing industry have consulted with the University of Minnesota's Cold Climate Housing Program to solve persistent energy and health-related problems such as ice dams, high energy bills, and mold/moisture issues-especially in complicated house types such as 1.5-story homes in cold climates. The NorthernSTAR Building America Partnership has completed multiple research projects on high-performance measures applied during renovation of single-family homes that could help the affordable housing industry address performance concerns. This demonstration project is an example of three high-performance measures applied to one house in Minneapolis, Minnesota. The selected vacant home was completely renovated by Urban Homeworks (UHW), which is a nonprofit housing partner, with the intent of selling the home to a low-income family. The renovation included the addition of the three advanced-performance technologies that were applied to the overall scope of the project. Single-family homes in urban areas that are available for renovation by nonprofit developers are often in need of repair. Budgeting has historically focused on improving homes to meet basic housing standards. A rising interest in the long-term impact of homeownership has introduced the need to balance basic needs with home performance. The goal of this demonstration project was to help UHW and other nonprofit developers become familiar with three U.S. Department of Energy Building America performance measures-including the installation processes, impacts, and benefits of each. To maximize efficiency of application and to address budget issues, the NorthernSTAR team worked with UHW to identify ways to use volunteers and construction training programs to install the measures. An open invitation to visit the job site was provided to other nonprofit developers and support teams to encourage dialog about the systems during live installation.

affordable housing↗

In Situ Microstructure Characterization of Potassium Di-Phosphate (KDP) Densification during Cold Sintering

In order for ceramic additive manufacturing (AM) to achieve its full potential, it is increasingly important to develop a more rigorous understanding of fundamental phenomena that govern the kinetics and thermodynamics of ceramic AM processes. In the case of additive build processes, such as direct ink write and ceramic extrusion, methods for densifying the resulting green-body product need to be considered to complement the efficiencies of ceramics AM, itself. One densification route, at least for monolithic components, built layer-by-layer, is offered by the recently developed cold sintering process, whereby high-density final product is achieved through addition of a small amount of liquid solvent and application of modest uniaxial compressive stress at relatively low temperature. In situ small-angle X-ray scattering methods and X-ray diffraction have been applied to characterize and quantify the pore morphology evolution during cold sintering for a model system: potassium di-phosphate, KH 2 PO 4 (KDP). It is shown that both temperature and applied stress affect the densification rate, but stress has a stronger effect on the evolving morphology. A regime with an approximate linear densification rate can be identified, yielding an effective densification activation energy of ≈90 kJ/mol.

36 MATERIALS SCIENCE↗