Search NASA⌕ Search

SEARCH · Search NASA

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Integrated and differential fiducial cross-section measurements for the vector boson fusion production of the Higgs boson in the $H → WW^* → evμv$ decay channel at 13 TeV with the ATLAS detector

The vector-boson production cross-section for the Higgs boson decay in the H→WW*→eνμν channel is measured as a function of kinematic observables sensitive to the Higgs boson production and decay properties as well as integrated in a fiducial phase space. The analysis is performed using the proton-proton collision data collected by the ATLAS detector in Run 2 of the LHC at $\sqrt{s}$=13 TeV center-of-mass energy corresponding to an integrated luminosity of 139 fb -1 . The different flavor final state is studied by selecting an electron and a muon originating from a pair of W bosons and compatible with the Higgs boson decay. The data are corrected for the effects of detector inefficiency and resolution, and the measurements are compared with different state-of-the-art theoretical predictions. The differential cross-sections are used to constrain anomalous interactions described by dimension-six operators in an Effective Field Theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Black and gray box learning of amplitude equations: Application to phase field systems

Here, we present a data-driven approach to learning surrogate models for amplitude equations and illustrate its application to interfacial dynamics of phase field systems. In particular, we demonstrate learning effective partial differential equations describing the evolution of phase field interfaces from full phase field data. We illustrate this on a model phase field system, where analytical approximate equations for the dynamics of the phase field interface (a higher-order eikonal equation and its approximation, the Kardar-Parisi-Zhang equation) are known. For this system, we discuss data-driven approaches for the identification of equations that accurately describe the front interface dynamics. When the analytical approximate models mentioned above become inaccurate, as we move beyond the region of validity of the underlying assumptions, the data-driven equations outperform them. In these regimes, going beyond black box identification, we explore different approaches to learning data-driven corrections to the analytically approximate models, leading to effective gray box partial differential equations.

42 ENGINEERING↗

SU-E-I-79: Source Geometry Dependence of Gamma Well-Counter Measurements

Purpose: To determine the effect of liquid sample volume and geometry on counting efficiency in a gamma well-counter, and to assess the relative contributions of sample geometry and self-attenuation. Gamma wellcounters are standard equipment in clinical and preclinical studies, for measuring patient blood radioactivity and quantifying animal tissue uptake for tracer development and other purposes. Accurate measurements are crucial. Methods: Count rates were measured for aqueous solutions of 99m- Tc at four liquid volume values in a 1-cm-diam tube and at six volume values in a 2.2-cm-diam vial. Total activity was constant for all volumes, and data were corrected for decay. Count rates from a point source in air, supported by a filter paper, were measured at seven heights between 1.3 and 5.7 cm from the bottom of a tube. Results: Sample volume effects were larger for the tube than for the vial. For the tube, count efficiency relative to a 1-cc volume ranged from 1.05 at 0.05 cc to 0.84 at 3 cc. For the vial, relative count efficiency ranged from 1.02 at 0.05 cc to 0.87 at 15 cc. For the point source, count efficiency relative to 1.3 cm from the tube bottom ranged from 0.98 at 1.8 cm to 0.34 at 5.7 cm. The relative efficiency of a 3-cc liquid sample in a tube compared to a 1-cc sample is 0.84; the average relative efficiency for the solid sample in air between heights in the tube corresponding to the surfaces of those volumes (1.3 and 4.8 cm) is 0.81, implying that the major contribution to efficiency loss is geometry, rather than attenuation. Conclusion: Volume-dependent correction factors should be used for accurate quantitation radioactive of liquid samples. Solid samples should be positioned at the bottom of the tube for maximum count efficiency.

60 APPLIED LIFE SCIENCES↗

SU-E-T-388: Evaluation of Electronic Brachytherapy Dose Distributions in Tissue Equivalent Materials

Purpose: To study the measured and calculated dose distributions for electronic brachytherapy (EBT) in various tissue equivalent homogenous materials. Methods: Calculated dose distributions in water were generated using published TG-43 parameters in Varian BrachyVision software for a 50 kVp, 50 cm Xoft source. Dose distributions were measured within a 3D-scanning tank using dosimeters including: PTW 0.125 cc, pin-point, and parallel-plate ion chambers, Sun Nuclear “Edge” diode and Gafchromic EBT3 film. Multi-channel film dosimetry was used in film analysis. EBT3 film curves were calibrated via radial dose comparison to both independently measured and published data. The resulting film calibration was utilized to measure dose distributions created by titanium filtered source utilized in clinical brachytherapy applications. Data was collected within homogenous PMMA, vinyl, polystyrene, paraffin, and water-equivalent plastic phantoms. Results: Ion-chamber data was corrected to effective points of measurement and normalized prior to comparison between calculated and measured dose distributions. Measurements made in water and water equivalent materials compared well with results from treatment planning software. The maximum percent differences (relative to water) observed between 1 cm and 3.5 cm depth from source for each of the phantom materials are as follows: PMMA 35%, polystyrene 41%, plastic-water 23%, vinyl 115%, and paraffin 46%. Conclusion: The increased probability of photoelectric interactions occurring within the patient during electronic brachytherapy will emphasize the radiological differences between varying human tissues in dose deposition. These differences can Result in clinically significant dose perturbations and it is therefore recommended to move to a model based dose calculation, as outlined in TG-186, to improve the dosimetric accuracy of low energy EBT.

60 APPLIED LIFE SCIENCES↗

SU-F-303-05: DCE-MRI Before and During Treatment for Prediction of Concurrent Chemotherapy and Radiation Therapy Response in Head and Neck Cancer

Purpose: To determine the ability of pharmacokinetic parameters derived from dynamic contrast-enhanced MRI (DCE- MRI) acquired before and during concurrent chemotherapy and radiation therapy to predict clinical response in patients with head and neck cancer. Methods: Eleven patients underwent a DCE-MRI scan at three time points: 1–2 weeks before treatment, 4–5 weeks after treatment initiation, and 3–4 months after treatment completion. Post-processing of MRI data included correction to reduce motion artifacts. The arterial input function was obtained by measuring the dynamic tracer concentration in the jugular veins. The volume transfer constant (Ktrans), extracellular extravascular volume fraction (ve), rate constant (Kep; Kep = Ktrans/ve), and plasma volume fraction (vp) were computed for primary tumors and cervical nodal masses. Patients were categorized into two groups based on response to therapy at 3–4 months: responders (no evidence of disease) and partial responders (regression of disease). Responses of the primary tumor and nodes were evaluated separately. A linear classifier and receiver operating characteristic curve analyses were used to determine the best model for discrimination of responders from partial responders. Results: When the above pharmacokinetic parameters of the primary tumor measured before and during treatment were incorporated into the linear classifier, a discriminative accuracy of 88.9%, with sensitivity =100% and specificity = 66.7%, was observed between responders (n=6) and partial responders (n=3) for the primary tumor with the corresponding accuracy = 44.4%, sensitivity = 66.7%, and specificity of 0% for nodal masses. When only pre-treatment parameters were used, the accuracy decreased to 66.7%, with sensitivity = 66.7% and specificity = 66.7% for the primary tumor and decreased to 33.3%, sensitivity of 50%, and specificity of 0% for nodal masses. Conclusion: Higher accuracy, sensitivity, and specificity were obtained using DCE-MRI-derived pharmacokinetic parameters acquired before and during treatment as compared with those derived from the pre-treatment time-point, exclusively.

60 APPLIED LIFE SCIENCES↗

SU-F-T-73: Experimental Determination of the Effective Point of Measurement in Electron Beams Using a Commercial Scintillation Detector

Purpose: The aim of this work was to determine experimentally the effective point of measurement (EPOM) in clinical electron beams for three cylindrical ionization chambers using a commercial scintillation detector as a reference detector. Methods: Percent depth dose (PDD) curves were measured using an Exradin W1 scintillation detector and were used as a representative PDD to water. Depth dose curves were measured with the Exradin A18, A1SL, and A28 ionization chambers. The raw ionization chamber curve data were corrected by the chamber fluence perturbation correction factor and restricted mass collisional stopping power ratio at each depth to obtain a percent depth dose curve to the gas volume (PDDGV) of the detector. Ratios of the W1 PDD to the ion chamber PDDGV were calculated for each measurement depth. The W1 PDD curve was shifted by small depth increments, Δz, until the ratio of the W1 PDD to the ion chamber PDDGV was depth-independent (optimal Δz). A MATLAB routine was developed to determine the optimal Δz value. Results: The optimal Δz shift was used as an estimate of the EPOM for each chamber. The average calculated EPOM shifts (expressed as a fraction of the chamber cavity radius) for the A18, A1SL, and A28 ionization chambers were 0.21 ± 0.04, 0.10 ± 0.05, and 0.22 ± 0.03, respectively. Conclusion: The experimentally determined EPOM values for the A18 and A1SL in this work agreed with the simulated values of Muir and Rogers (MedPhys 2014). The results also indicate that the Exradin W1 scintillator is water equivalent for electron energies of 6 MeV, 9 MeV, 12 MeV, and 16 MeV. In addition, we confirmed that the AAPM TG51 recommended EPOM shift of 0.5 times the cavity radius is not accurate for the A18 and A1SL chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of single-diffractive dijet production in proton-proton collisions at $\sqrt{s} =$ 8 TeV with the CMS and TOTEM experiments

Measurements are presented of the single-diffractive dijet cross section and the diffractive cross section as a function of the proton fractional momentum loss $\xi $ and the four-momentum transfer squared t. Both processes ${\text{ p }{}{}} {\text{ p }{}{}} \rightarrow {\text{ p }{}{}} {\text{ X }} $ and ${\text{ p }{}{}} {\text{ p }{}{}} \rightarrow {\text{ X }} {\text{ p }{}{}} $, i.e. with the proton scattering to either side of the interaction point, are measured, where ${\text{ X }} $ includes at least two jets; the results of the two processes are averaged. The analyses are based on data collected simultaneously with the CMS and TOTEM detectors at the LHC in proton–proton collisions at $\sqrt{s} = 8\,\text {Te}\text {V} $ during a dedicated run with $\beta ^{*} = 90\,\text {m} $ at low instantaneous luminosity and correspond to an integrated luminosity of $37.5{\,\text {nb}^{-1}} $. The single-diffractive dijet cross section $\sigma ^{{\text{ p }{}{}} {\text{ X }}}_{\mathrm {jj}}$, in the kinematic region $\xi < 0.1$, $0.03< |t | < 1\,\text {Ge}\text {V} ^2$, with at least two jets with transverse momentum $p_{\mathrm {T}} > 40\,\text {Ge}\text {V} $, and pseudorapidity $|\eta | < 4.4$, is $21.7 \pm 0.9\,\text {(stat)} \,^{+3.0}_{-3.3}\,\text {(syst)} \pm 0.9\,\text {(lumi)} \,\text {nb} $. The ratio of the single-diffractive to inclusive dijet yields, normalised per unit of $\xi $, is presented as a function of x, the longitudinal momentum fraction of the proton carried by the struck parton. The ratio in the kinematic region defined above, for x values in the range $-2.9 \le \log _{10} x \le -1.6$, is $R = (\sigma ^{{\text{ p }{}{}} {\text{ X }}}_{\mathrm {jj}}/\Delta \xi )/\sigma _{\mathrm {jj}} = 0.025 \pm 0.001\,\text {(stat)} \pm 0.003\,\text {(syst)} $, where $\sigma ^{{\text{ p }{}{}} {\text{ X }}}_{\mathrm {jj}}$ and $\sigma _{\mathrm {jj}}$ are the single-diffractive and inclusive dijet cross sections, respectively. The results are compared with predictions from models of diffractive and nondiffractive interactions. Monte Carlo predictions based on the HERA diffractive parton distribution functions agree well with the data when corrected for the effect of soft rescattering between the spectator partons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Differential cross-section measurements for the electroweak production of dijets in association with a Z boson in proton–proton collisions at ATLAS

Differential cross-section measurements are presented for the electroweak production of two jets in association with a Z boson. These measurements are sensitive to the vector-boson fusion production mechanism and provide a fundamental test of the gauge structure of the Standard Model. The analysis is performed using proton–proton collision data collected by ATLAS at √s=13 TeV and with an integrated luminosity of 139 fb -1 . The differential cross-sections are measured in the Z→ℓ + ℓ - decay channel (ℓ=e,μ) as a function of four observables: the dijet invariant mass, the rapidity interval spanned by the two jets, the signed azimuthal angle between the two jets, and the transverse momentum of the dilepton pair. The data are corrected for the effects of detector inefficiency and resolution and are sufficiently precise to distinguish between different state-of-the-art theoretical predictions calculated using Powheg+Pythia8, Herwig7+Vbfnlo and Sherpa 2.2. The differential cross-sections are used to search for anomalous weak-boson self-interactions using a dimension-six effective field theory. The measurement of the signed azimuthal angle between the two jets is found to be particularly sensitive to the interference between the Standard Model and dimension-six scattering amplitudes and provides a direct test of charge-conjugation and parity invariance in the weak-boson self-interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the light-flavour jet mistagging efficiency of the b -tagging algorithms with Z+jets events using 139 $\textrm{fb}^{-1}$ of ATLAS proton–proton collision data at $\sqrt{s} = 13$ TeV

The identification of b -jets, referred to as b -tagging, is an important part of many physics analyses in the ATLAS experiment at the Large Hadron Collider and an accurate calibration of its performance is essential for high-quality physics results. This publication describes the calibration of the light-flavour jet mistagging efficiency in a data sample of proton–proton collision events at $\sqrt{s} = 13$ TeV corresponding to an integrated luminosity of 139 fb -1 . The calibration is performed in a sample of Z bosons produced in association with jets. Due to the low mistagging efficiency for light-flavour jets, a method which uses modified versions of the b-tagging algorithms referred to as flip taggers is used in this work. A fit to the jet-flavour-sensitive secondary-vertex mass is performed to extract a scale factor from data, to correct the light-flavour jet mistagging efficiency in Monte Carlo simulations, while simultaneously correcting the b -jet efficiency. With this procedure, uncertainties coming from the modeling of jets from heavy-flavour hadrons are considerably lower than in previous calibrations of the mistagging scale factors, where they were dominant. The scale factors obtained in this calibration are consistent with unity within uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Silica Precipitation and Lithium Sorption

This file contains silica precipitation and lithium sorption data from the project. The silica removal data is corrected from the previous submission. The previous submission did not take into account the limit of detection of the ICP-MS procedure.

15 GEOTHERMAL ENERGY↗

Dosimetry characterization of the Godiva Reactor under burst conditions

A series of sixteen (16) burst irradiations were performed in May 2014, fifteen of which were part of an international collaboration to characterize the Godiva IV fast burst reactor at the National Criticality Experiments Research Center (NCERC). Godiva IV is a bare cylindrical assembly of approximately 65 kg of highly enriched uranium fuel (93.2% 235 U metal alloyed with 1.5% molybdenum for strength) and is designed to perform controlled prompt critical excursions (Myers 2010, Goda 2013). Twelve of the irradiations were dedicated to neutron spectral measurements using a Bonner multiple sphere spectrometer. Three irradiations, with core temperature increases of 71.1°C, 136.9°C, and 229.9°C, were performed for generating comparative fluence data, establishing corrections for varying heights, testing linearity with burst temperature, and establishing gamma dose characteristics.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Charge response and energy calibration of ProtoDUNE-

ProtoDUNE-SP is a test bed liquid argon time projection chamber (LArTPC) for the far detector of the Deep Underground Neutrino Experiment (DUNE). This LArTPC was calibrated using cosmic-ray cathode-crossing muons, electric field maps, and purity-monitor data to correct for nonuniformities in the detector response and cosmic-ray stopping muons to perform the absolute energy scale calibration for further physics analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Addendum to ICSBEP Logbooks 12r, 13r, 14r and 15r for Polyethylene and Graphite Reflected HEU Metal Critical Experiments

This report documents the experimenters’ data sheets that were recently (2023) discovered for critical experiments with highly enriched uranium metal with polyethylene and graphite reflectors. These data sheets were produced at the time of the measurements, when the dimensional inspection reports for the polyethylene and graphite were available. However, at this writing, those inspection reports are not available but may be in unmarked storage for the Y-12 National Security Complex. However, the data sheets presented herein contain sketches of the experimental configurations and other additional information that is not in the logbooks, such as dimensions and masses of the graphite measurements. This report reproduces the experimental data sheets that complement the logbooks. Some of the data on these sheets and the logbooks can be used to infer the dimensions and masses that are not documented. Some obvious mistakes in the logbook and data sheets have been corrected. In the reproduced data sheets, some of the information is not clearly visible: some information, such as average values, can be obtained from other data in the sheets or logbook. This report should be sent to the International Criticality Safety Benchmark Program at Idaho National Laboratory to complement the existing Oak Ridge Critical Facility logbooks there.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao↗

INTEGRATE – Inverse Network Transformations for Efficient Generation of Robust Airfoil and Turbine Enhancements

The INTEGRATE (Inverse Network Transformations for Efficient Generation of Robust Airfoil and Turbine Enhancements) project developed a new inverse-design capability for the aerodynamic design of wind turbine rotors using invertible neural networks. Training data was obtained from improved turbulence and transition models for RANS and hybrid RANS/LES solvers with machine-learned physics-based data-augmented corrections and then using the resulting neural-network(s) augmented RANS model to run thousands of 2-D and 3-D CFD simulations.

17 WIND ENERGY↗

Direction-dependent Corrections in Polarimetric Radio Imaging. I. Characterizing the Effects of the Primary Beam on Full-Stokes Imaging

Next generation radio telescope arrays are being designed and commissioned to accurately measure polarized intensity and rotation measures (RMs) across the entire sky through deep, wide-field radio interferometric surveys. Radio interferometer dish antenna arrays are affected by direction-dependent (DD) gains due to both instrumental and atmospheric effects. In this paper, we demonstrate the effect of DD errors of the parabolic dish antenna array on the measured polarized intensities of radio sources in interferometric images. We characterize the extent of polarimetric image degradation due to the DD gains through wide-band VLA simulations of representative point-source simulations of the radio sky at L band (1–2 GHz). We show that at the 0.5 gain level of the primary beam there is significant flux leakage from Stokes I to Q , U amounting to 10% of the total intensity. We further demonstrate that while the instrumental response averages down for observations over large parallactic angle intervals, full-polarization DD correction is required to remove the effects of DD leakage. We also explore the effect of the DD beam on the RM signals and show that while the instrumental effect is primarily centered around 0 rad-m{sup −2}, the effect is significant over a broad range of RM requiring full polarization DD correction to accurately reconstruct the RM synthesis signal.

79 ASTRONOMY AND ASTROPHYSICS↗

The Pointing Self-calibration Algorithm for Aperture Synthesis Radio Telescopes

This paper is concerned with algorithms for calibration of direction-dependent effects (DDE) in aperture synthesis radio telescopes (ASRT). After correction of direction-independent effects (DIE) using self-calibration, imaging performance can be limited by the imprecise knowledge of the forward gain of the elements in the array. In general, the forward gain pattern is directionally dependent and varies with time due to a number of reasons. Some factors, such as rotation of the primary beam with Parallactic Angle for Azimuth–Elevation mount antennas are known a priori. Some, such as antenna pointing errors and structural deformation/projection effects for aperture-array elements cannot be measured a priori. Thus, in addition to algorithms to correct for DD effects known a priori, algorithms to solve for DD gains are required for high dynamic range imaging. Here, we discuss a mathematical framework for antenna-based DDE calibration algorithms and show that this framework leads to computationally efficient optimal algorithms that scale well in a parallel computing environment. As an example of an antenna-based DD calibration algorithm, we demonstrate the Pointing SelfCal (PSC) algorithm to solve for the antenna pointing errors. Our analysis show that the sensitivity of modern ASRT is sufficient to solve for antenna pointing errors and other DD effects. We also discuss the use of the PSC algorithm in real-time calibration systems and extensions for antenna Shape SelfCal algorithm for real-time tracking and corrections for pointing offsets and changes in antenna shape.

79 ASTRONOMY AND ASTROPHYSICS↗

The Pan-STARRS1 Medium-deep Survey: Star Formation Quenching in Group and Cluster Environments

We make use of a catalog of 1600 Pan-STARRS1 groups produced by the probability friends-of-friends algorithm to explore how the galaxy properties, i.e., the specific star formation rate (SSFR) and quiescent fraction, depend on stellar mass and group-centric radius. The work is the extension of Lin et al. In this work, powered by a stacking technique plus a background subtraction for contamination removal, a finer correction and more precise results are obtained than in our previous work. We find that while the quiescent fraction increases with decreasing group-centric radius, the median SSFRs of star-forming galaxies in groups at fixed stellar mass drop slightly from the field toward the group center. This suggests that the main quenching process in groups is likely a fast mechanism. On the other hand, a reduction in SSFRs by ∼0.2 dex is seen inside clusters as opposed to the field galaxies. If the reduction is attributed to the slow quenching effect, the slow quenching process acts dominantly in clusters. In addition, we also examine the density–color relation, where the density is defined by using a sixth-nearest-neighbor approach. Comparing the quiescent fractions contributed from the density and radial effect, we find that the density effect dominates the massive group or cluster galaxies, and the radial effect becomes more effective in less massive galaxies. The results support mergers and/or starvation as the main quenching mechanisms in the group environment, while harassment and/or starvation dominate in clusters.

79 ASTRONOMY AND ASTROPHYSICS↗