Search NASA⌕ Search

SEARCH · Search NASA

Results for “data channels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Helium glow detector experiment, MA-088

Of the two 584 A channels in the helium glow detector, channel #1 appeared to provide data with erratic count rates and undue susceptibility to dayglow and solar contamination possibly because of filter fatigue or failure. Channel #3 data appear normal and of high quality. For this reason only data from this last channel was analyzed and used for detailed comparison with theory. Reduction and fitting techniques are described, as well as applications of the data in the study of nighttime and daytime Hel 584 A emission. A hot model of the interstellar medium is presented. Topics covered in the appendix include: observations of interstellar helium with a gas absorption cell: implications for the structure of the local interstellar medium; EUV dayglow observations with a helium gas absorption cell; and EUV scattering from local interstellar helium at nonzero temperatures: implications for the derivations of interstellar medium parameters.

Bowyer, C. S.↗

Increasing Density and Reducing Costs of Data Acquisition

There are a number of reasons why it is important to increase the density of data acquisition functions. Sensor fusion seeks to integrate large numbers of sensors into a decision network. Addition of health monitoring functions may incur additional sensor requirements. But at the same time, it is important to reduce the per-channel costs of data acquisition systems. Often the most significant cost is the management of data acquisition networks, which incurs substantial costs associated with transducer installation, configuration, calibration, and maintenance. Alternatives that lower the cost of the transducer system and reduce the data acquisition system channel count will directly impact initial system costs. Other techniques that affect maintenance and operating costs will contribute to reducing life cycle costs. This paper describes work undertaken to explore alternative architectures for lowering the cost per transducer function using a MEMS-based accelerometer as the model.

Schmalzel, J. L.↗

Performance of noncoherent MFSK channels with coding

Computer simulation of data transmission over a noncoherent channel with predetection signal-to-noise ratio of 1 shows that convolutional coding can reduce the energy requirement by 4.5 dB at a bit error rate of 0.001. The effects of receiver quantization and choice of number of tones are analyzed; nearly optimum performance is attained with eight quantization levels and sixteen tones at predetection S/N ratio of 1. The effects of changing predetection S/N ratio are also analyzed; for lower predetection S/N ratio, accurate extrapolations can be made from the data, but for higher values, the results are more complicated. These analyses will be useful in designing telemetry systems when coherence is limited by turbulence in the signal propagation medium or oscillator instability.

Butman, S. A.↗

Helicity-dependent reaction {gamma}-vectord-vector{yields}{pi}NN and its contribution to the Gerasimov-Drell-Hearn sum rule for the deuteron

Helicity-dependent incoherent pion photoproduction in the reaction {gamma}-vectord-vector{yields}{pi}NN is studied in the framework of the diagrammatic approach. Contributions to the reaction amplitude from diagrams corresponding to impulse approximation as well as NN and {pi}N interactions in the final state have been evaluated. The elementary {gamma}N{yields}{pi}N operator is taken from the MAID and SAID models. A detailed comparison of the predictions with recent experimental data by the GDH and A2 collaborations at energies below 500 MeV is presented. Reasonable agreement with the data on the yields and cross sections for the polarized beam and polarized target has been achieved in all channels. The unpolarized data of the GDH and A2 collaborations have also been analyzed within the approach. A strong overestimation for the neutral channel has been found. At the same time, the model provides a quite satisfactory description of the unpolarized data for the charged channels. The sensitivity of the obtained results to the choice of the elementary {gamma}N{yields}{pi}N operator is discussed in detail. The contribution of the {gamma}d{yields}{pi}NN reaction to the GDH sum rule for the deuteron up to a photon energy of 1.65 GeV has been evaluated with the result of 235{+-}25 {mu}b.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Large Extra Spatial Dimensions in the Dielectron and Diphoton Channels in pp Collisions at {radical}(s)=1.96 TeV

We report on a search for large extra spatial dimensions in the dielectron and diphoton channels using a data sample of 1.05 fb{sup -1} of pp collisions at a center-of-mass energy of 1.96 TeV collected by the D0 detector at the Fermilab Tevatron Collider. The invariant mass spectrum of the data agrees well with the prediction of the standard model. We find the most restrictive 95% C.L. lower limits on the effective Planck scale between 2.1 and 1.3 TeV for 2 to 7 extra dimensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correction of thin cirrus effects in AVIRIS images using the sensitive 1.375-micron cirrus detecting channel

Using spectral imaging data acquired with the Airborne Visible Infrared Imaging Spectrometer (AVIRIS) from an ER-2 aircraft at 20 km altitude during various field programs, it was found that narrow channels near the center of the strong 1.38-micrometer water vapor band are very effective in detecting think cirrus clouds. Based on this observation from AVIRIS data, Gao and Kaufman proposed to put a channel centered at 1.375 micrometers with a width of 30 nm on the Moderate Resolution Imaging Spectrometer (MODIS) for remote sensing of cirrus clouds from space. The sensitivity of the 1.375-micrometer MODIS channel to detect thin cirrus clouds during the day time is expected to be one to two orders of magnitude better than the current infrared emission techniques. As a result, much larger fraction of the satellite data is expected to be identified as being covered by cirrus clouds, some of them so thin that their obscuration of the surface is very small. In order to make better studies of surface reflectance properties, thin cirrus effects must be removed from satellite images. Therefore, there is a need to study radiative properties of thin cirrus clouds, so that a strategy for correction or removal of the thin cirrus effects, similar to the correction of atmospheric aerosol effect, can be formed. In this extended abstract, we describe an empirical approach for removing/correcting thin cirrus effects in AVIRIS images using channels near 1.375 microns - one step beyond the detection of cirrus clouds using these channels.

Gao, Bo-Cai↗

End-to-end imaging information rate advantages of various alternative communication systems

The efficiency of various deep space communication systems which are required to transmit both imaging and a typically error sensitive class of data called general science and engineering (gse) are compared. The approach jointly treats the imaging and gse transmission problems, allowing comparisons of systems which include various channel coding and data compression alternatives. Actual system comparisons include an advanced imaging communication system (AICS) which exhibits the rather significant advantages of sophisticated data compression coupled with powerful yet practical channel coding. For example, under certain conditions the improved AICS efficiency could provide as much as two orders of magnitude increase in imaging information rate compared to a single channel uncoded, uncompressed system while maintaining the same gse data rate in both systems. Additional details describing AICS compression and coding concepts as well as efforts to apply them are provided in support of the system analysis.

Rice, R. F.↗

Two-channel Costas loop tracking performance for UQPSK signals with arbitrary data formats

Previous results on the tracking performance of two-channel Costas-type carrier synchronization loops are generalized and corrected, in order that they may be applied to several mixed-format cases. In particular, the mean-square phase jitter performance of these loops with active arm filters, synchronous or asynchronous symbol clocks, and arbitrary data formats on the two channels is examined. It is demonstrated that for each case, selection of the channel gain ratio, as motivated by the MAP estimation theory, does not guarantee optimum loop tracking performance: in some instances, a conventional single-channel Costas loop would outperform the two-channel version with the MAP choice of gain ratio. It is suggested that the gain ratio be chosen to directly minimize the mean-square phase tracking jitter which is equivalent to minimizing the loop's 'squaring loss'. This can, in some cases, improve the performance measure, although in all cases, the two-channel loop will still outperform the single-channel version.

Simon, M. K.↗

A computer-controlled, on-board data acquisition system for wind-tunnel testing

A computer-controlled data acquisition system has been developed for the 40x80-foot wind tunnel at Ames Research Center. The system, consisting of several small onboard units installed in the model and a data-managing, data-displaying ground station, is capable of sampling up to 256 channels of raw data at a total sample rate of 128,000 samples/sec. Complete signal conditioning is contained within the on-board units. The sampling sequence and channel gain selection is completely random and under total control of the ground station. Outputs include a bar-graph display, digital-to-analog converters, and digital interface to the tunnel's central computer, an SEL 840MP. The system can be run stand-alone or under the control of the SEL 840MP.

Finger, H. J.↗

Updates to Relevance Vector Machine: Multiclass Classification, Variable Selection, and Proof-of-Concept Application to Safeguards Fresh Fuel Verification using List-Mode Neutron Collar Data

To expand the capabilities of safeguards authorities to verify the integrity of fresh fuel assemblies, Oak Ridge National Laboratory has retrofit the existing electronics of the JCC-71 uranium neutron coincidence collar, which contains 18 3 He neutron detectors and an external 241 AmLi(α, n) neutron interrogation source arranged to surround a fresh nuclear fuel assembly. The new electronics system allows analysts to record list-mode neutron multiplicity data in addition to the singles and doubles rates that are currently measured. Based on previous proof-of-concept research, analysis of these new data will identify off-normal fuel configurations in an assembly and characterize or localize the specific partial fuel defects. The purpose of this report it to document the analysis algorithm development and then to demonstrate its capability for the safeguards verification of fresh fuel assemblies using list mode neutron collar data. To analyze the complex list-mode data collected with the upgraded uranium neutron collar, multivariate classification algorithms are being developed using a novel classification method, the relevance vector machine. This approach may be applied to multiclass problems to estimate the probability that test data belongs to one of many possible classes of data. In addition, our method identifies the most useful variables/channels for making predictions, which illuminates the basis for the model’s predictions, and this interpretability is largely unique among data analytics methods. Variable selection occurs during model training and parameter tuning and does not need any external hyperparameter tuning routines. Finally, we apply the modified relevance vector machine to a simulated dataset of list-mode neutron collar data generated with the radiation transport code MCNP. The method can correctly identify off-normal fuel configurations, categorize the data according to four fuel defect scenarios, and rank the channels in the data according to prediction utility. For nuclear safeguards applications, it is concluded that this method has the potential to increase the sensitivity and reliability to detect missing fuel rods from a standard 17 x 17 Pressurized Water Reactor (PWR) fresh fuel assembly. Within this analysis, “off-normal” (i.e., missing fuel rods) were correctly classified in 17 simulated test scenarios with one quarter (25%) of the fresh fuel rods missing using a training data set of 58 simulated measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Program for the analysis of time series

A digital computer program for the Fourier analysis of discrete time data is described. The program was designed to handle multiple channels of digitized data on general purpose computer systems. It is written, primarily, in a version of FORTRAN 2 currently in use on CDC 6000 series computers. Some small portions are written in CDC COMPASS, an assembler level code. However, functional descriptions of these portions are provided so that the program may be adapted for use on any facility possessing a FORTRAN compiler and random-access capability. Properly formatted digital data are windowed and analyzed by means of a fast Fourier transform algorithm to generate the following functions: (1) auto and/or cross power spectra, (2) autocorrelations and/or cross correlations, (3) Fourier coefficients, (4) coherence functions, (5) transfer functions, and (6) histograms.

Brown, T. J.↗

Multipolarization SAR data for surface feature delineation and forest vegetation characterization

This paper presents the utility of multipolarization Synthetic Aperture Radar (SAR) data for surface feature delineation and forest vegetation characterization. Three channels of radioed data (VV/HH, VH/HH, and VH/VV) are generated from the HH, VV, and VH polarization data (V = vertical, H = horizontal). The radioed data are linearly stretched to yield a digital number within a range of 0 to 255. The techniques for reducing SAR speckle noise and for measuring the degree of separation are discussed. For surface feature delineation, the results indicate that cross polarization as well as cross polarization radioed data better delineate those surface features that are difficult to separate by like polarization data. The results suggest using a median value filtering technique to reduce within-plot data fluctuation to increase the separability measure. For forest vegetation characterization, the results indicate that multipolarization SAR data may be used to estimate forest properties such as total-tree biomass, basal area, and tree height.

Wu, Shih-Tseng↗

Practical constraints on network architecture and signalling in the MSAT system

Telesat Mobile Inc. plans to provide mobile satellite communications services in Canada in 1993/4, in close cooperation with the American Mobile Satellite Consortium Inc., which will be providing services in the U.S.A. L-band frequencies will be used in multiple beams for communication with mobile terminals. Ku-band frequencies will be used for the feeder-links to fixed stations. The system will support voice and data communications. The baseline Canadian system will support approximately 450 assignable voice channels, some fraction of which will be the equivalent in data channels. The method of multiple access will be Frequency Division Multiple Access/Single Channel Per Carrier. The availability of frequencies, the availability of technology and the time scale for implementation all constrain the network architecture for the system. Further, it is important to have an open specification to encourage multiple equipment vendors. The interplay of these constraints is discussed.

Davies, N. George↗

Free-Energy Calculations. A Mathematical Perspective

Ion channels are pore-forming assemblies of transmembrane proteins that mediate and regulate ion transport through cell walls. They are ubiquitous to all life forms. In humans and other higher organisms they play the central role in conducting nerve impulses. They are also essential to cardiac processes, muscle contraction and epithelial transport. Ion channels from lower organisms can act as toxins or antimicrobial agents, and in a number of cases are involved in infectious diseases. Because of their important and diverse biological functions they are frequent targets of drug action. Also, simple natural or synthetic channels find numerous applications in biotechnology. For these reasons, studies of ion channels are at the forefront of biophysics, structural biology and cellular biology. In the last decade, the increased availability of X-ray structures has greatly advanced our understanding of ion channels. However, their mechanism of action remains elusive. This is because, in order to assist controlled ion transport, ion channels are dynamic by nature, but X-ray crystallography captures the channel in a single, sometimes non-native state. To explain how ion channels work, X-ray structures have to be supplemented with dynamic information. In principle, molecular dynamics (MD) simulations can aid in providing this information, as this is precisely what MD has been designed to do. However, MD simulations suffer from their own problems, such as inability to access sufficiently long time scales or limited accuracy of force fields. To assess the reliability of MD simulations it is only natural to turn to the main function of channels - conducting ions - and compare calculated ionic conductance with electrophysiological data, mainly single channel recordings, obtained under similar conditions. If this comparison is satisfactory it would greatly increase our confidence that both the structures and our computational methodologies are sufficiently accurate. Channel conductance, defined as the ratio of ionic current through the channel to applied voltage, can be calculated in MD simulations by way of applying an external electric field to the system and counting the number of ions that traverse the channel per unit time. If the current is small, a voltage significantly higher than the experimental one needs to be applied to collect sufficient statistics of ion crossing events. Then, the calculated conductance has to be extrapolated to the experimental voltage using procedures of unknown accuracy. Instead, we propose an alternative approach that applies if ion transport through channels can be described with sufficient accuracy by the one-dimensional diffusion equation in the potential given by the free energy profile and applied voltage. Then, it is possible to test the assumptions of the equation, recover the full voltage/current dependence, determine the reliability of the calculated conductance and reconstruct the underlying (equilibrium) free energy profile, all from MD simulations at a single voltage. We will present the underlying theory, model calculations that test this theory and simulations on ion conductance through a channel that has been extensively studied experimentally. To our knowledge this is the first case in which the complete, experimentally measured dependence of the current on applied voltage has been reconstructed from MD simulations.

free energy↗

Radiometric resolution enhancement by lossy compression as compared to truncation followed by lossless compression

Recent advances in imaging technology make it possible to obtain imagery data of the Earth at high spatial, spectral and radiometric resolutions from Earth orbiting satellites. The rate at which the data is collected from these satellites can far exceed the channel capacity of the data downlink. Reducing the data rate to within the channel capacity can often require painful trade-offs in which certain scientific returns are sacrificed for the sake of others. In this paper we model the radiometric version of this form of lossy compression by dropping a specified number of least significant bits from each data pixel and compressing the remaining bits using an appropriate lossless compression technique. We call this approach 'truncation followed by lossless compression' or TLLC. We compare the TLLC approach with applying a lossy compression technique to the data for reducing the data rate to the channel capacity, and demonstrate that each of three different lossy compression techniques (JPEG/DCT, VQ and Model-Based VQ) give a better effective radiometric resolution than TLLC for a given channel rate.

Tilton, James C.↗

Memory-based parallel data output controller

A memory-based parallel data output controller employs associative memories and memory mapping to decommutate multiple channels of telemetry data. The output controller contains a random access memory (RAM) which has at least as many address locations as there are channels. A word counter addresses the RAM which provides as it outputs an encoded peripheral device number and a MSB/LSB-first flag. The encoded device number and a bit counter address a second RAM which contains START and STOP flags to pick out the required bits from the specified word number. The LSB/MSB, START and STOP flags, along with the serial input digital data go to a control block which selectively fills a shift register used to drive the parallel data output bus.

Stattel, R. J.↗

Data acquisition and analysis on a Macintosh

The introduction of inexpensive analog-to-digital boards for the Macintosh opens the way for its use in areas that have previously been filled by either specialized, dedicated or more expensive mainframe based systems. Two such Macintosh-based systems are the Acoustic Laboratory Data Acquisition System (ALDAS) and the Jet Calibration and Hover Test Facility (JCAHT) data acquisition system. ALDAS provides an inexpensive, transportable means to digitize four channels at up to 50,000 samples per second and analyze this data. The ALDAS software package was written for use with rotorcraft acoustics and performs automatic acoustic calibration of channels, data display, and various types of data analysis. The program can use data obtained either from internal analog-to-digital conversion or discrete external data imported in ASCII format. All aspects of ALDAS can be improved as new hardware becomes available and new features are introduced into the code. The JCAHT data acquisition system was built as not only an analysis program but also to act as the online safety monitoring system. This paper will provide an overview of these systems.

Watts, Michael E.↗