Replacing Neural Networks by Optimal Analytical Predictors for the Detection of Phase Transitions
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Industrial Control Systems (ICS) and Supervisory Control and Data Acquisition (SCADA) environments are essential to modern infrastructure, facing challenges in ensuring low-latency, high-throughput communication while mitigating cyber threats. This paper presents a framework integrating Federated Learning (FL) and network slicing with Quality of Service (QoS) to enable real-time monitoring without disrupting OT operations. Leveraging digital twin technology and Network Function Virtualization (NFV), the architecture supports predictive analytics and Industry 4.0 requirements. FL facilitates decentralized model training, preserving data privacy and scalability, though it introduces potential throughput constraints. Network slicing addresses this by creating dedicated virtualized segments optimized for performance and security. Advanced fault tolerance at the container and instance levels enhances system reliability. The proposed architecture ensures high throughput, low latency, and secure orchestration for real-time anomaly detection in OT networks. Performance evaluations validate its efficiency in throughput, deployment, and learning accuracy, providing a robust foundation for future ICS automation and data-driven decision-making.
Abstract not provided.
We explore the sensitivity offered by a global network of cosmic-ray detectors to a novel, unobserved phenomenon: widely separated simultaneous extended air showers. Existing localized observatories work independently to observe individual showers, offering insight into the source and nature of ultrahigh-energy cosmic rays. However no current observatory is large enough to provide sensitivity to anticipated processes such as the Gerasimova–Zatsepin effect or potential new physics that generate simultaneous air showers separated by hundreds to thousands of kilometers. A global network of consumer electronics (the Cosmic Rays Found In Smartphones (CRAYFIS) experiment), may provide a novel opportunity for observation of such phenomena. Two user scenarios are explored. In the first, with maximal user adoption, we find that statistically significant discoveries of spatially separated but coincident showers are possible within a couple years. In the second, more practical adoption model with 10 6 active devices, we find a worldwide CRAYFIS to be sensitive to novel "burst" phenomena where many simultaneous extensive air showers (EAS) occur at once.
In LANDSAT imagery, spectral and spatial information can be used to detect the drainage network as well as the relative elevation model in mountainous terrain. To do this, the mixed information of material reflectance and topographic modulation in the original LANDSAT imagery must be first separated. From the material reflectance information, big visible rivers can be detected. From the topographic modulation information, ridges and valleys can be detected and assigned relative elevations. Finally, a relative elevation model can be generated by interpolating values for nonridge and nonvalley pixels.
A sensor node detects a plurality of information-based events. The sensor node determines whether at least one other sensor node is an information neighbor of the sensor node based on at least a portion of the plurality of information-based events. The information neighbor has an overlapping field of view with the sensor node. The sensor node sends at least one communication to the at least one other sensor node that is an information neighbor of the sensor node in response to at least one information-based event of the plurality of information-based events.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
A system for detecting water trees in branching underground electrical cables includes a pulse generator configured to inject a pulse into a first underground cable that branches into a second underground cable and a third underground cable. The system includes a first sensor associated with the first cable, a second sensor associated with the second cable, and a third sensor associated with the third cable. The system includes a control device configured to obtain a first, second, and third signal associated with the first, second and third sensors, respectively. The control device determines a lead-lag relationship between the second and third signals and determines presence of a water tree within at least one of the second and third cable based on the lead-lag relationship. When presence of a water tree is determined, the control device generates a control action associated with repairing or replacing the second and/or third cable.
Recent published work assessed the amount of time to detect trends in atmospheric water vapor over the coming century. We address the same question and conclude that under the most optimistic scenarios and assuming perfect data (i.e., observations with no measurement uncertainty) the time to detect trends will be at least 12 years at approximately 200 hPa in the upper troposphere. Our times to detect trends are therefore shorter than those recently reported and this difference is affected by data sources used, method of processing the data, geographic location and pressure level in the atmosphere where the analyses were performed. We then consider the question of how instrumental uncertainty plays into the assessment of time to detect trends. We conclude that due to the high natural variability in atmospheric water vapor, the amount of time to detect trends in the upper troposphere is relatively insensitive to instrumental random uncertainty and that it is much more important to increase the frequency of measurement than to decrease the random error in the measurement. This is put in the context of international networks such as the Global Climate Observing System (GCOS) Reference Upper-Air Network (GRUAN) and the Network for the Detection of Atmospheric Composition Change (NDACC) that are tasked with developing time series of climate quality water vapor data.
A magnetic direction-finding network for the detection of lightning cloud-to-ground strikes has been installed along the east coast of the United States. Most of the lightning occurring from Maine to Florida and as far west as Ohio is detected. Time, location, flash polarity, stroke count, and peak signal amplitude are recorded in real time. Flash locations, time, and polarity are displayed routinely for research and operational purposes. Flash density maps have been generated for the summers of 1983 and 1984, when the network only extended to North Carolina, and show density maxima in northern Virginia and Maryland.
Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.
Modern computer network defense systems rely primarily on signature-based intrusion detection tools, which generate alerts when patterns that are pre-determined to be malicious are encountered in network data streams. Signatures are created reactively, and only after in-depth manual analysis of a network intrusion. There is little ability for signature-based detectors to identify intrusions that are new or even variants of an existing attack, and little ability to adapt the detectors to the patterns unique to a network environment. Due to these limitations, the need exists for network intrusion detection techniques that can more comprehensively address both known unknown networkbased attacks and can be optimized for the target environment. This work describes a system that leverages machine learning to provide a network intrusion detection capability that analyzes behaviors in channels of communication between individual computers. Using examples of malicious and non-malicious traffic in the target environment, the system can be trained to discriminate between traffic types. The machine learning provides insight that would be difficult for a human to explicitly code as a signature because it evaluates many interdependent metrics simultaneously. With this approach, zero day detection is possible by focusing on similarity to known traffic types rather than mining for specific bit patterns or conditions. This also reduces the burden on organizations to account for all possible attack variant combinations through signatures. The approach is presented along with results from a third-party evaluation of its performance.
Deep-learner hyper-parameters, such as kernel sizes, batch sizes, and learning rates, can significantly influence the quality of trained models. The state of the art for finding optimal hyper-parameters generally uses a brute force, grid search approach, random search, or Bayesian-based optimization among other techniques. We applied an evolutionary algorithm to optimize kernel sizes for a convolutional neural network used to detect settlements in satellite imagery. Usually convolutional layer kernel sizes are small - typically one, three, or five - but we found that the system converged at, or near, kernel sizes of nine for the last convolutional layer, and that this occurred for multiple runs using two different datasets. Moreover, the larger kernel sizes had fewer false positives than the 3x3 kernel sizes found as optimal via a brute force uniform grid search. This suggests that this large kernel size may be leveraging patterns found in larger areal features in the source imagery, and that this may be generalized as possible guidance for similar remote sensing deep-learning tasks.
Abstract Automated guard cell detection and measurement are vital for understanding plant physiological performance and ecological functioning in global water and carbon cycles. Most current methods for measuring guard cells and stomata are laborious, time-consuming, prone to bias, and limited in scale. We developed StoManager1, a high-throughput tool utilizing geometrical, mathematical algorithms, and convolutional neural networks to automatically detect, count, and measure over 30 guard cell and stomatal metrics, including guard cell and stomatal area, length, width, stomatal aperture area/guard cell area, orientation, stomatal evenness, divergence, and aggregation index. Combined with leaf functional traits, some of these StoManager1-measured guard cell and stomatal metrics explained 90% and 82% of tree biomass and intrinsic water use efficiency (iWUE) variances in hardwoods, making them substantial factors in leaf physiology and tree growth. StoManager1 demonstrated exceptional precision and recall (mAP@0.5 over 0.96), effectively capturing diverse stomatal properties across over 100 species. StoManager1 facilitates the automation of measuring leaf stomatal and guard cells, enabling broader exploration of stomatal control in plant growth and adaptation to environmental stress and climate change. This has implications for global gross primary productivity (GPP) modeling and estimation, as integrating stomatal metrics can enhance predictions of plant growth and resource usage worldwide. Easily accessible open-source code and standalone Windows executable applications are available on a GitHub repository (https://github.com/JiaxinWang123/StoManager1) and Zenodo (https://doi.org/10.5281/zenodo.7686022).