Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric

Receiver Operator Characteristic (ROC) curves are commonly applied as metrics for quantifying the performance of binary fault detection systems. An ROC curve provides a visual representation of a detection system s True Positive Rate versus False Positive Rate sensitivity as the detection threshold is varied. The area under the curve provides a measure of fault detection performance independent of the applied detection threshold. While the standard ROC curve is well suited for quantifying binary fault detection performance, it is not suitable for quantifying the classification performance of multi-fault classification problems. Furthermore, it does not provide a measure of diagnostic latency. To address these shortcomings, a novel three-dimensional receiver operator characteristic (3D ROC) surface metric has been developed. This is done by generating and applying two separate curves: the standard ROC curve reflecting fault detection performance, and a second curve reflecting fault classification performance. A third dimension, diagnostic latency, is added giving rise to 3D ROC surfaces. Applying numerical integration techniques, the volumes under and between the surfaces are calculated to produce metrics of the diagnostic system s detection and classification performance. This paper will describe the 3D ROC surface metric in detail, and present an example of its application for quantifying the performance of aircraft engine gas path diagnostic methods. Metric limitations and potential enhancements are also discussed

Simon, Donald L.↗

Filter failure detection for systems with large space structure dynamics

A failure detection filter is applied to the detection of actuator and sensor failures on a free-free beam. Computer simulation tests are used to verify the filter design and study the effect of unmodeled modes on filter performance. In actuator tests, the failure signal to spillover noise ratio was found to be greatest when the filter bandwidth was 5 rad/sec beyond the input frequency. Observation spillover, however, was found to vary widely in tests run under similar conditions (same input frequency and filter poles) but with different detector gains. In sensor tests, the maximum signal-to-noise ratio for varying filter bandwidth depended upon the initial conditions placed on the unmodeled modes; the performance was good even for initial amplitudes on the first unmodeled mode 7.5% of that on the last modeled mode.

Carignan, C. R.↗

Deep learning methods for event verification and image re-purposing detection

Systems and methods herein describe accessing an image, generating a resized image, generating an image feature vector by applying an image classification neural network to the resized image, generating analysis of the image by processing the image feature vector using a machine-learning classifier trained to analyze the image feature vector, and based on the analysis, determining an event that is attributed to the image.

Nataraj, Lakshmanan↗

Fault detection of helicopter gearboxes using the multi-valued influence matrix method

In this paper we investigate the effectiveness of a pattern classifying fault detection system that is designed to cope with the variability of fault signatures inherent in helicopter gearboxes. For detection, the measurements are monitored on-line and flagged upon the detection of abnormalities, so that they can be attributed to a faulty or normal case. As such, the detection system is composed of two components, a quantization matrix to flag the measurements, and a multi-valued influence matrix (MVIM) that represents the behavior of measurements during normal operation and at fault instances. Both the quantization matrix and influence matrix are tuned during a training session so as to minimize the error in detection. To demonstrate the effectiveness of this detection system, it was applied to vibration measurements collected from a helicopter gearbox during normal operation and at various fault instances. The results indicate that the MVIM method provides excellent results when the full range of faults effects on the measurements are included in the training set.

Chin, Hsinyung↗

Research on reconstruction method for pebble-detecting CT system for PB-HTGR - 186633

In the pebble-bed high temperature gas-cooled reactor (PB-HTGR), pebble dynamics in the reactor is important for safe operation. However, the experimental research at present were mostly implemented in two-dimensional models or limited to phenomenological methods. To investigate pebble dynamics using a three-dimensional experimental method, we designed a platform with a pebble-detecting CT system exactly as the proportion of 1:5 with the actual HTR-PM. Multi-slice helical CT can provide cross-sectional images of fuel pebbles at any place during motion, allowing for pebble trajectories to be obtained during the whole unloading process. The purpose of this paper is to design appropriate algorithms to reconstruct cross-sectional images of pebbles for the system. Two methods applicable to distinct situations were discussed and compared. Based on this, a fast reconstruction method was introduced and proved to be the most suitable solution for the system to get pebble trajectories rapidly. The pebble-detecting principle and the effectiveness of the fast reconstruction method were demonstrated by a verification experiment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Methods, microfluidic devices, and systems for detection of an active enzymatic agent

Embodiments of the present invention provide methods, microfluidic devices, and systems for the detection of an active target agent in a fluid sample. A substrate molecule is used that contains a sequence which may cleave in the presence of an active target agent. A SNAP25 sequence is described, for example, that may be cleaved in the presence of Botulinum Neurotoxin. The substrate molecule includes a reporter moiety. The substrate molecule is exposed to the sample, and resulting reaction products separated using electrophoretic separation. The elution time of the reporter moiety may be utilized to identify the presence or absence of the active target agent.

60 APPLIED LIFE SCIENCES↗

An adaptive incremental approach to constructing ensemble classifiers: Application in an information-theoretic computer-aided decision system for detection of masses in mammograms

Ensemble classifiers have been shown efficient in multiple applications. In this article, the authors explore the effectiveness of ensemble classifiers in a case-based computer-aided diagnosis system for detection of masses in mammograms. They evaluate two general ways of constructing subclassifiers by resampling of the available development dataset: Random division and random selection. Furthermore, they discuss the problem of selecting the ensemble size and propose two adaptive incremental techniques that automatically select the size for the problem at hand. All the techniques are evaluated with respect to a previously proposed information-theoretic CAD system (IT-CAD). The experimental results show that the examined ensemble techniques provide a statistically significant improvement (AUC=0.905{+-}0.024) in performance as compared to the original IT-CAD system (AUC=0.865{+-}0.029). Some of the techniques allow for a notable reduction in the total number of examples stored in the case base (to 1.3% of the original size), which, in turn, results in lower storage requirements and a shorter response time of the system. Among the methods examined in this article, the two proposed adaptive techniques are by far the most effective for this purpose. Furthermore, the authors provide some discussion and guidance for choosing the ensemble parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Performance of a Sensor System for Detection of Multiple Chemicals Using an External Cavity Quantum Cascade Laser

We describe the performance of a sensor system designed for simultaneous detection of multiple chemicals with both broad and narrow absorption features. The sensor system consists of a broadly tunable external cavity quantum cascade laser (ECQCL), multi-pass Herriott cell, and custom low-noise electronics. The ECQCL features a rapid wavelength tuning rate of 2265 cm 1/s (15660 nm/s) over its tuning range of 1150-1270 cm 1 (7.87-8.70 μm), which permits detection of molecules with broad absorption features and dynamic concentrations, while the 0.2 cm-1 spectral resolution of the ECQCL system allows measurement of small molecules with atmospherically broadened absorption lines. High-speed amplitude modulation and low-noise electronics are used to improve the ECQCL performance for direct absorption measurements. We demonstrate simultaneous detection of Freon-134a (1,1,1,2-tetrafluoroethane), ammonia (NH3), and nitrous oxide (N2O) at low-ppb concentrations in field measurements of atmospheric chemical releases from a point source.

(140.3600) Lasers, tunable↗

Radiation sensitive devices and systems for detection of radioactive materials and related methods

Radiation sensitive devices include a substrate comprising a radiation sensitive material and a plurality of resonance elements coupled to the substrate. Each resonance element is configured to resonate responsive to non-ionizing incident radiation. Systems for detecting radiation from a special nuclear material include a radiation sensitive device and a sensor located remotely from the radiation sensitive device and configured to measure an output signal from the radiation sensitive device. In such systems, the radiation sensitive device includes a radiation sensitive material and a plurality of resonance elements positioned on the radiation sensitive material. Methods for detecting a presence of a special nuclear material include positioning a radiation sensitive device in a location where special nuclear materials are to be detected and remotely interrogating the radiation sensitive device with a sensor.

36 MATERIALS SCIENCE↗

Advanced Detector and Waveform Digitizer for Water Vapor DIAL Systems

Measurement of atmospheric water vapor has become a major requirement for understanding moist-air processes. Differential absorption lidar (DIAL) is a technique best suited for the measurement of atmospheric water vapor. NASA Langley Research Center is continually developing improved DIAL systems. One aspect of current development is focused on the enhancement of a DIAL receiver by applying state-of-the-art technology in building a new compact detection system that will be placed directly on the DIAL receiver telescope. The newly developed detection system has the capability of being digitally interfaced with a simple personal computer, using a discrete input/output interface. This has the potential of transmitting digital data over relatively long distances instead of analog signals, which greatly reduces measurement noise. In this paper, we discuss some results from the new compact water vapor DIAL detection system which includes a silicon based avalanche photodiode (APD) detector, a 14-bit, 10-MHz waveform digitizer, a microcontroller and other auxiliary electronics. All of which are contained on a small printed-circuit-board. This will significantly reduce the weight and volume over the current CAMAC system and eventually will be used in a water vapor DIAL system on an unpiloted atmospheric vehicle (UAV) aircraft, or alternatively on an orbiting spacecraft.

Refaat, Tamer F.↗

Airborne Windshear Detection and Warning Systems. Fifth and Final Combined Manufacturers' and Technologists' Conference, part 2

The Fifth Combined Manufacturers' and Technologists' Airborne Windshear Review Meeting was hosted by the NASA Langley Research Center and the Federal Aviation Administration in Hampton, Virginia, on September 28-30, 1993. The purpose was to report on the highly successful windshear experiments conducted by government, academic institutions, and industry; to transfer the results to regulators, manufacturers, and users; and to set initiatives for future aeronautics technology research. The formal sessions covered recent developments in windshear flight testing, windshear modeling, flight management, and ground-based systems, airborne windshear detection systems, certification and regulatory issues, and development and applications of sensors for wake vortices and for synthetic and enhanced vision systems. This report was compiled to record and make available the technology updates and materials from the conference.

Delnore, Victor E.↗

Characterization of Advanced Avalanche Photodiodes for Water Vapor Lidar Receivers

Development of advanced differential absorption lidar (DIAL) receivers is very important to increase the accuracy of atmospheric water vapor measurements. A major component of such receivers is the optical detector. In the near-infrared wavelength range avalanche photodiodes (APD's) are the best choice for higher signal-to-noise ratio, where there are many water vapor absorption lines. In this study, characterization experiments were performed to evaluate a group of silicon-based APD's. The APD's have different structures representative of different manufacturers. The experiments include setups to calibrate these devices, as well as characterization of the effects of voltage bias and temperature on the responsivity, surface scans, noise measurements, and frequency response measurements. For each experiment, the setup, procedure, data analysis, and results are given and discussed. This research was done to choose a suitable APD detector for the development of an advanced atmospheric water vapor differential absorption lidar detection system operating either at 720, 820, or 940 nm. The results point out the benefits of using the super low ionization ratio (SLIK) structure APD for its lower noise-equivalent power, which was found to be on the order of 2 to 4 fW/Hz(sup (1/2)), with an appropriate optical system and electronics. The water vapor detection systems signal-to-noise ratio will increase by a factor of 10.

Refaat, Tamer F.↗

Radiation detector based on a matrix of crossed wavelength-shifting fibers

A radiation detection system comprising a detection grid of wavelength shifting fibers with a volume of scintillating material at the intersecting points of the fibers. Light detectors, preferably Silicon Photomultipliers, are positioned at the ends of the fibers. The position of radiation is determined from data obtained from the detection grid. The system is easily scalable, customizable, and also suitable for use in soil and underground applications. An alternate embodiment employs a fiber grid sheet or layer which is comprised of multiple fibers secured to one another within the same plane. This embodiment further includes shielding in order to prevent radiation cross-talk within the grid layer.

36 MATERIALS SCIENCE↗

Liquid chromatography detection unit, system, and method

An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-261: Development of An Automated System to Detect Patient Identification and Positioning Errors Prior to Radiotherapy Treatment

Purpose: To develop a system that can automatically detect patient identification and positioning errors using 3D computed tomography (CT) setup images and kilovoltage CT (kVCT) planning images. Methods: Planning kVCT images were collected for head-and-neck (H&N), pelvis, and spine treatments with corresponding 3D cone-beam CT (CBCT) and megavoltage CT (MVCT) setup images from TrueBeam and TomoTherapy units, respectively. Patient identification errors were simulated by registering setup and planning images from different patients. Positioning errors were simulated by misaligning the setup image by 1cm to 5cm in the six anatomical directions for H&N and pelvis patients. Misalignments for spine treatments were simulated by registering the setup image to adjacent vertebral bodies on the planning kVCT. A body contour of the setup image was used as an initial mask for image comparison. Images were pre-processed by image filtering and air voxel thresholding, and image pairs were assessed using commonly-used image similarity metrics as well as custom -designed metrics. A linear discriminant analysis classifier was trained and tested on the datasets, and misclassification error (MCE), sensitivity, and specificity estimates were generated using 10-fold cross validation. Results: Our workflow produced MCE estimates of 0.7%, 1.7%, and 0% for H&N, pelvis, and spine TomoTherapy images, respectively. Sensitivities and specificities ranged from 98.0% to 100%. MCEs of 3.5%, 2.3%, and 2.1% were obtained for TrueBeam images of the above sites, respectively, with sensitivity and specificity estimates between 96.2% and 98.4%. MCEs for 1cm H&N/pelvis misalignments were 1.3/5.1% and 9.1/8.6% for TomoTherapy and TrueBeam images, respectively. 2cm MCE estimates were 0.4%/1.6% and 3.1/3.2%, respectively. Vertebral misalignment MCEs were 4.8% and 4.9% for TomoTherapy and TrueBeam images, respectively. Conclusion: Patient identification and gross misalignment errors can be robustly and automatically detected using 3D setup images of two imaging modalities across three commonly-treated anatomical sites.

60 APPLIED LIFE SCIENCES↗

Space shuttle orbital maneuvering system failure detection and identification software requirements (uncontrolled)

Candidate designs and their software implementation are presented for the Orbital Maneuvering System (OMS) Failure Detection and Identification (FDI) algorithms in the Redundance Management (RM) module of the Space Shuttle Guidance, Navigation, and Control (GN&C) software. The OMS engine FDI algorithm monitors OMS engine thrust performance, and the OMS actuator FDI algorithm monitors OMS gimbal actuator performance. The software functional requirements of the algorithms are described along with the objective of each algorithm. A list of the assumptions which have governed its design, input/output requirements, a functional description of the algorithm (including a functional block diagram), and input interface requirements are given. The HAL (the language of the space shuttle flight computer) software formulation of the algorithms is considered including structured flowcharts of the procedures, estimates of flight computer core storage and CPU time, and processing requirements. A glossary of the symbols used to define the software requirements and formulations is included.

Damario, L. A.↗

Intrusion detection apparatus, system and methods

Described herein are various technologies for detection and mitigation of rogue terminal attacks on multiplex data buses. An intrusion detection device is incorporated between a bus controller and a bus of a multiplex data bus. The intrusion detection device receives message that are communicated among the bus controller and a plurality of remote terminals (by way of the bus). The intrusion detection device determines whether messages are unauthorized based upon origins of the messages and predefined rules. When a message is determined to be unauthorized, the intrusion detection device outputs a notification that the unauthorized message has been detected and can block the unauthorized message.

97 MATHEMATICS AND COMPUTING↗

Validation of Minimum Display Requirements for a UAS Detect and Avoid System

The full integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS), a prerequisite for enabling a broad range of public and commercial UAS operations, presents several technical challenges to UAS developers, operators and regulators. A primary barrier is the inability for UAS pilots (situated at a ground control station, or GCS) to comply with Title 14 Code of Federal Regulations sections 91.111 and 91.113, which require pilots to “see and avoid” other aircraft in order to maintain well clear. UAS pilots’ removal from the flight deck of the aircraft necessitates the development of a UAS-specific system for detecting nearby traffic and displaying traffic information to the pilot to support their ability to maintain an objectively defined “DAA well clear” threshold from other aircraft. This new UAS-specific function of remaining DAA well clear is called traffic avoidance. The resulting Detect and Avoid (DAA) system, however, will be subject to a collection of requirements that manufacturers will be obligated to meet in order to certify their equipment. RTCA Special Committee 228 (SC-228), a consortium of representatives from government, industry and academia, is responsible for developing and documenting the Minimum Operational Performance Standards (MOPS) for UAS DAA systems. The present study is the final in a series of human-in-the-loop (HITL) experiments designed to explore and test the various display and alerting requirements being incorporated into the DAA MOPS. Whereas the prior DAA HITLs examined a wide variety of DAA display features and concepts, the current experiment aims to validate the latest minimum display requirements for Phase 1 of the DAA MOPS. Rather than test different display concepts, this study tests two configurations of a MOPS-compatible DAA display: a version that is integrated into the primary navigation and control display of the GCS and a version that is physically separated from the primary display. This manipulation tests the draft minimum requirement that allows the DAA traffic display to be a separate, or standalone, configuration. This type of configuration is a more achievable near-term technology solution since it does not stipulate additional certification or integration requirements on UAS manufacturers. However, a standalone display configuration has the potential to result in pilot performance issues resulting from the cognitive costs of switching between the primary DAA display and the primary navigation and control display. This configuration is also particularly susceptible to errors if the displays are in different orientations (e.g., north-up versus track-up). Both the integrated and standalone display configurations were presented to 16 active UAS pilots in a medium-fidelity simulation, which included confederate air traffic controllers and pseudo pilots operating simulated manned traffic. Pilots were tasked with navigating two different mission routes while maintaining DAA well clear with scripted conflicts. Pilot response times (i.e., measured response) and ability to remain DAA well clear are reported. Primary results indicate that both display configurations resulted in favorable response times and well clear rates. While there were clear trends of pilots objectively performing better in the integrated display condition, with several measured response metrics reaching statistical significance, the differences between the two displays were typically moderate. While the primary variable of DAA display location did not have an especially large impact on pilot performance on its own, when examined alongside the type of DAA threat the pilot was facing (a caution-level versus a warning-level alert), the response time benefits associated with the integrated display were amplified. The implications of these American Institute of Aeronautics and Astronautics 2 results on the Phase 1 DAA MOPS and the connection of this data to previous studies is also discussed.

detect and avoid↗