Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct simulation Monte Carlo methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

SU-G-TeP3-06: Nanoparticle-Aided External Beam Radiotherapy Leveraging the Cerenkov Effect

Purpose: This study investigates the feasibility of exploiting the Cerenkov radiation (CR) present during external beam radiotherapy (EBRT) for significant therapeutic gain, using titanium dioxide nanoparticles (titania) delivered via a new design of radiotherapy biomaterials. Methods: Recently published work has shown that CR generated by radionuclides during PET imaging could substantially enhance damage to cancer cells in the presence of 0.625 µg/g titania. We hypothesize that equal or greater damage can be achieved during EBRT. To test this hypothesis, Monte Carlo simulation was done using GEANT4 in order to get the total CR yield inside a tumor volume during EBRT compared to that of the radionuclides. We considered a novel approach where a sufficiently potent concentration of the titania was delivered directly into the tumor using radiotherapy biomaterials (e.g. fiducials) loaded with the titania. The intra-tumor distribution/diffusion of titania released from the fiducials was calculated. An in-vitro MTS assay experiment was also carried out to establish the relative non-toxicity of titania for concentrations of up to 1 µg/g. Results: For a radiotherapy biomaterial loaded with 15 µg/g of 2-nm titania, at least 0.625 µg/g could be delivered through out a tumor sub-volume of 2-cm diameter after 14 days. This concentration level could inflict substantial damage to tumor cells during EBRT. The Monte Carlo results showed the CR yield in tumor by 6 MV radiation was higher than the radionuclides and hence potentially greater damage may be obtained during EBRT. No significant cell viability change was observed for 1 µg/g titania. Conclusion: Altogether, these preliminary findings demonstrate a potential new approach that can be used to take advantage of the CR present during megavoltage EBRT to boost damage to tumor cells. The results provide significant impetus for further experimental studies towards development of nanoparticle-aided EBRT powered by the Cerenkov effect.

60 APPLIED LIFE SCIENCES↗

Parallel Fokker–Planck-DSMC algorithm for rarefied gas flow simulation in complex domains at all Knudsen numbers

A major challenge for the conventional Direct Simulation Monte Carlo (DSMC) technique lies in the fact that its computational cost becomes prohibitive in the near continuum regime, where the Knudsen number (Kn)—characterizing the degree of rarefaction—becomes small. In contrast, the Fokker–Planck (FP) based particle Monte Carlo scheme allows for computationally efficient simulations of rarefied gas flows in the low and intermediate Kn regime. The Fokker–Planck collision operator—instead of performing binary collisions employed by the DSMC method—integrates continuous stochastic processes for the phase space evolution in time. This allows for time step and grid cell sizes larger than the respective collisional scales required by DSMC. Dynamically switching between the FP and the DSMC collision operators in each computational cell is the basis of the combined FP-DSMC method, which has been proven successful in simulating flows covering the whole Kn range. Until recently, this algorithm had only been applied to two-dimensional test cases. In this contribution, we present the first general purpose implementation of the combined FP-DSMC method. Utilizing both shared- and distributed-memory parallelization, this implementation provides the capability for simulations involving many particles and complex geometries by exploiting state of the art computer cluster technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct simulation Monte Carlo modeling of relaxation processes in polyatomic gases

Relaxation processes of polyatomic molecules are modeled and implemented in an in-house Direct Simulation Monte Carlo code in order to enable the simulation of atmospheric entry maneuvers at Mars and Saturn’s Titan. The description of rotational and vibrational relaxation processes is derived from basic quantum-mechanics using a rigid rotator and a simple harmonic oscillator, respectively. Strategies regarding the vibrational relaxation process are investigated, where good agreement for the relaxation time according to the Landau-Teller expression is found for both methods, the established prohibiting double relaxation method and the new proposed multi-mode relaxation. Differences and applications areas of these two methods are discussed. Consequently, two numerical methods used for sampling of energy values from multi-dimensional distribution functions are compared. The proposed random-walk Metropolis algorithm enables the efficient treatment of multiple vibrational modes within a time step with reasonable computational effort. The implemented model is verified and validated by means of simple reservoir simulations and the comparison to experimental measurements of a hypersonic, carbon-dioxide flow around a flat-faced cylinder.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-555: A Protontherapy Inverse Treatment Planning System Prototype with Linear Energy Transfer (LET) Optimization

Purpose: Develop and benchmark an inverse treatment planning system (TPS) for proton radiotherapy integrating fast analytical dose and LET calculations in patient geometries and a dual objective function with both dose and LET components, enabling us to apply optimization techniques to improve the predicted outcome of treatments based on radiobiological models. Methods: The software package was developed in MATLAB and implements a fluence-dose calculation technique based on a pencil beam model for dose calculations and a 3D LET model based on the extension of the LET in the radial direction as a function of the predicted radiological pathway. Both models were benchmarked against commissioning data from our institution, dose calculations performed with a commercial treatment planning system and Monte Carlo simulations. The optimization is based on the adaptive simulated annealing approach . Results: The dose and LET calculations were tested in a water phantom and several real patient treatments. The pass rate for the gamma index analysis (3%/3mm) test was above 90% for all test cases analyzed, and the calculation time was of the order of seconds. The inverse planning module produced plans with a significantly higher mean LET in the target compared to traditional plans, without any loss of target coverage. The clinical relevance of this improvement is under consideration . Conclusion: The developed treatment planning system is a valuable clinical and research tool that enables us to incorporate LET effects into proton radiotherapy planning in a streamlined fashion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HDR {sup 192}Ir source speed measurements using a high speed video camera

Purpose: The dose delivered with a HDR {sup 192}Ir afterloader can be separated into a dwell component, and a transit component resulting from the source movement. The transit component is directly dependent on the source speed profile and it is the goal of this study to measure accurate source speed profiles. Methods: A high speed video camera was used to record the movement of a {sup 192}Ir source (Nucletron, an Elekta company, Stockholm, Sweden) for interdwell distances of 0.25–5 cm with dwell times of 0.1, 1, and 2 s. Transit dose distributions were calculated using a Monte Carlo code simulating the source movement. Results: The source stops at each dwell position oscillating around the desired position for a duration up to (0.026 ± 0.005) s. The source speed profile shows variations between 0 and 81 cm/s with average speed of ∼33 cm/s for most of the interdwell distances. The source stops for up to (0.005 ± 0.001) s at nonprogrammed positions in between two programmed dwell positions. The dwell time correction applied by the manufacturer compensates the transit dose between the dwell positions leading to a maximum overdose of 41 mGy for the considered cases and assuming an air-kerma strength of 48 000 U. The transit dose component is not uniformly distributed leading to over and underdoses, which is within 1.4% for commonly prescribed doses (3–10 Gy). Conclusions: The source maintains its speed even for the short interdwell distances. Dose variations due to the transit dose component are much lower than the prescribed treatment doses for brachytherapy, although transit dose component should be evaluated individually for clinical cases.

07 ISOTOPE AND RADIATION SOURCES↗

Atomistic simulation methods for long-time dynamics in materials for nuclear energy systems

Many important processes in materials systems are intrinsically atomistic in nature but involve time scales that span many orders of magnitude, thus exceeding what can be directly simulated using molecular dynamics. This is especially true for materials in nuclear energy applications, in which defects created by collision cascades on the femtosecond-picosecond time scale cause microstructural changes that continue to evolve for years, in many cases leading to failure of the material. In this chapter, we review atomistic methods for reaching long time scales in systems like these. These accelerated molecular dynamics and adaptive kinetic Monte Carlo methods exploit the infrequent-event nature of the diffusive events that comprise this long-time evolution. In favorable cases, these methods can predict state-to-state evolution that approximates what would result from an extremely long molecular dynamics simulation, and the most accurate of the methods can do this to arbitrary accuracy. We present some examples of applications of these methods to problems relevant to nuclear energy materials, the subject of this volume. We then discuss situations that are difficult for the methods, causing them to be less efficient, and we conclude with a short list of the most pressing issues in the further development of these approaches to make them as powerful and predictive as possible for realistic problems.

36 MATERIALS SCIENCE↗

SU-F-BRA-06: Dose Distributions for the CivaSheet Pd-103 Directional Brachytherapy Device

Purpose: A flexible polymer membrane (CivaSheet) has been developed by CivaTech Oncology, Inc. (Research Triangle Park, NC) for permanent brachytherapy. Distributed throughout the array are small plastic disks containing Pd-103 and gold foil shielding on one side to provide a directional dose distribution and facilitate imaging. This study evaluated dosimetry for the CivaSheet. Methods: Manufacturer-provided dimensional and compositional information for the device were compared to physical samples for validation of design information, then entered into the MCNP6 radiation transport code for dosimetry simulations. Three device sizes (6×6, 6×12, or 6×18 disk-arrays) were simulated as the membrane can be custom-sized preceding surgical placement. Dose to water was estimated with 0.01 cm resolution from the surface to 10 cm on both sides of the device. Because this is a novel device with calibration methods under development, results were normalized using DVHs to provide 90% prescription coverage to a plane positioned 0.5 cm from the front surfaces. This same normalization was used for creating isodose distributions. Results: Planar dose distributions of flat CivaSheets were relatively homogeneous with acceptable dose uniformity variations. Differences in the results between the differently sized CivaSheets were not significant. At 0.5 mm, 87% of the target volume was within the therapeutic dose range. Dose hotspots on the CivaSheet forward surfaces were directly above the disks. However, dose hotspots on the rear-facing surfaces were positioned between the disks. Doses in contact with the front surface were similar to those observed for currently available brachytherapy sources. Maximum doses that occurred on the rear surface were approximately 55 times lower than the dose on the front surface. Conclusion: Monte Carlo calculations validated the directional capabilities and advantageous dosimetry of the new Pd-103 brachytherapy device. It appears feasible to re-size the CivaSheet in the operating room with an acceptable variation in prescription dose. Research was supported by CivaTech Oncology, Inc.

60 APPLIED LIFE SCIENCES↗

MO-G-BRE-01: A Real-Time Virtual Delivery System for Photon Radiotherapy Delivery Monitoring

Purpose: Treatment delivery monitoring is important for radiotherapy, which enables catching dosimetric error at the earliest possible opportunity. This project develops a virtual delivery system to monitor the dose delivery process of photon radiotherapy in real-time using GPU-based Monte Carlo (MC) method. Methods: The simulation process consists of 3 parallel CPU threads. A thread T1 is responsible for communication with a linac, which acquires a set of linac status parameters, e.g. gantry angles, MLC configurations, and beam MUs every 20 ms. Since linac vendors currently do not offer interface to acquire data in real time, we mimic this process by fetching information from a linac dynalog file at the set frequency. Instantaneous beam fluence map (FM) is calculated. A FM buffer is also created in T1 and the instantaneous FM is accumulated to it. This process continues, until a ready signal is received from thread T2 on which an inhouse developed MC dose engine executes on GPU. At that moment, the accumulated FM is transferred to T2 for dose calculations, and the FM buffer in T1 is cleared. Once the calculation finishes, the resulting 3D dose distribution is directed to thread T3, which displays it in three orthogonal planes overlaid on the CT image for treatment monitoring. This process continues to monitor the 3D dose distribution in real-time. Results: An IMRT and a VMAT cases used in our patient-specific QA are studied. Maximum dose differences between our system and treatment planning system are 0.98% and 1.58% for the two cases, respectively. The average time per MC calculation is 0.1sec with <2% relative uncertainty. The update frequency of ∼10Hz is considered as real time. Conclusion: By embedding a GPU-based MC code in a novel data/work flow, it is possible to achieve real-time MC dose calculations to monitor delivery process.

60 APPLIED LIFE SCIENCES↗

Search for gauge extensions of the MSSM at the LHC

The extensions of the minimal supersymmetric model (MSSM), driving mainly from the need to solve the {mu} problem, involve novel matter species and gauge groups. These extended MSSM models can be searched for at the LHC via the effects of the gauge and Higgs bosons or their fermionic partners. Traditionally, the focus has been on the study of the extra forces induced by the new gauge and Higgs bosons present in such models. An alternative way of studying such effects is through the superpartners of matter species and the gauge forces. We thus consider a U(1)' gauge extension of the MSSM, and perform an extensive study of the signatures of the model through the production and decays of the scalar quarks and gluino, which are expected to be produced copiously at the LHC. After a detailed study of the distinctive features of such models with regard to the signatures at the LHC, we carry out a detailed Monte Carlo analysis of the signals from the process pp{yields}n leptons+m jets+Ee{sub T}, and compare the resulting distributions with those predicted by the MSSM. Our results show that the searches for the extra gauge interactions in the supersymmetric framework can proceed not only through the forces mediated by the gauge and Higgs bosons but also through the superpartner forces mediated by the gauge and Higgs fermions. Analysis of the events induced by the squark/gluino decays presented here is complementary to the direct Z' searches at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D Radiation Nonideal Magnetohydrodynamical Simulations of the Inner Rim in Protoplanetary Disks

Many planets orbit within 1 au of their stars, raising questions about their origins. Particularly puzzling are the planets found near the silicate sublimation front. We investigate conditions near the front in the protostellar disk around a young intermediate-mass star, using the first global 3D radiation nonideal MHD simulations in this context. We treat the starlight heating; the silicate grains’ sublimation and deposition at the local, time-varying temperature and density; temperature-dependent ohmic dissipation; and various initial magnetic fields. The results show magnetorotational turbulence around the sublimation front at 0.5 au. The disk interior to 0.8 au is turbulent, with velocities exceeding 10% of the sound speed. Beyond 0.8 au is the dead zone, cooler than 1000 K and with turbulence orders of magnitude weaker. A local pressure maximum just inside the dead zone concentrates solid particles, favoring their growth. Over many orbits, a vortex develops at the dead zone’s inner edge, increasing the disk’s thickness locally by around 10%. We synthetically observe the results using Monte Carlo transfer calculations, finding that the sublimation front is near-infrared bright. The models with net vertical magnetic fields develop extended, magnetically supported atmospheres that reprocess extra starlight, raising the near-infrared flux 20%. The vortex throws a nonaxisymmetric shadow on the outer disk. At wavelengths >2 μm, the flux varies several percent on monthly timescales. The variations are more regular when the vortex is present. The vortex is directly visible as an arc at ultraviolet through near-infrared wavelengths, given sub-au spatial resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

REVISITING THE INFLUENCE OF UNIDENTIFIED BINARIES ON VELOCITY DISPERSION MEASUREMENTS IN ULTRA-FAINT STELLAR SYSTEMS

Velocity dispersion measurements of recently discovered Milky Way satellites with M{sub V} {approx_gt} -7 imply that they posses high mass-to-light ratios. The expected velocity dispersions due to their baryonic mass are {approx}0.2 km s{sup -1}, but values {approx_gt}3 km s{sup -1} are measured. We perform Monte Carlo simulations of mock radial velocity measurements of these systems assuming that they have mass-to-light ratios similar to globular clusters and posses an unidentified binary star population, to determine if these stars could boost the velocity dispersion to the observed values. We find that this hypothesis is unlikely to produce dispersions much in excess of {approx}4.5 km s{sup -1}, in agreement with previous work. However, for the systems with the potentially smallest velocity dispersions, values consistent with observations are produced in 5%-40% of our simulations for binary fractions in excess of f {sub bin}(P {<=} 10 yr){approx} 5%. This sample includes the dwarf galaxy candidates that lie closest to classical globular clusters in M{sub V} - r{sub h} space. Considered as a population, it is unlikely that all of these dwarf galaxy candidates have mass-to-light ratios typical of globular clusters, but boosting of the observed dispersion by binaries from near-zero values cannot be ruled out at high confidence for several individual dwarf galaxy candidates. Given the importance of obtaining accurate velocity dispersions and dynamical masses for the faintest satellites, it is clearly desirable to directly exclude the possible effect of binaries on these systems. This requires multi-epoch radial velocity measurements with individual uncertainties of {approx_lt}1 km s{sup -1} to identify spectroscopic binaries with orbital velocities of the order of the observed velocity dispersion.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-E-BRE-09: TrueBeam Monte Carlo Absolute Dose Calculations Using Monitor Chamber Backscatter Simulations and Linac-Logged Target Current

Purpose: To simulate and measure radiation backscattered into the monitor chamber of a TrueBeam linac; establish a rigorous framework for absolute dose calculations for TrueBeam Monte Carlo (MC) simulations through a novel approach, taking into account the backscattered radiation and the actual machine output during beam delivery; improve agreement between measured and simulated relative output factors. Methods: The ‘monitor backscatter factor’ is an essential ingredient of a well-established MC absolute dose formalism (the MC equivalent of the TG-51 protocol). This quantity was determined for the 6 MV, 6X FFF, and 10X FFF beams by two independent Methods: (1) MC simulations in the monitor chamber of the TrueBeam linac; (2) linac-generated beam record data for target current, logged for each beam delivery. Upper head MC simulations used a freelyavailable manufacturer-provided interface to a cloud-based platform, allowing use of the same head model as that used to generate the publicly-available TrueBeam phase spaces, without revealing the upper head design. The MC absolute dose formalism was expanded to allow direct use of target current data. Results: The relation between backscatter, number of electrons incident on the target for one monitor unit, and MC absolute dose was analyzed for open fields, as well as a jaw-tracking VMAT plan. The agreement between the two methods was better than 0.15%. It was demonstrated that the agreement between measured and simulated relative output factors improves across all field sizes when backscatter is taken into account. Conclusion: For the first time, simulated monitor chamber dose and measured target current for an actual TrueBeam linac were incorporated in the MC absolute dose formalism. In conjunction with the use of MC inputs generated from post-delivery trajectory-log files, the present method allows accurate MC dose calculations, without resorting to any of the simplifying assumptions previously made in the TrueBeam MC literature. This work has been partially funded by Varian Medical Systems.

07 ISOTOPE AND RADIATION SOURCES↗

Differential Heat of Adsorption and Isosteres

Heat of adsorption is a basic thermodynamic property extensively used not only for understanding thermal effects and heat management in industrial gas storage and separation processes but also for development and validation of adsorption models and materials force fields. Despite a long history of theoretical studies and a vast experimental literature, controversies often arise in the thermodynamic analysis of heat effects due to various assumptions used to describe gas adsorption and inconsistencies between direct calorimetric measurements and isosteric heat obtained from various adsorption isotherms. Here we present a rigorous theoretical procedure for predicting isosteric heat without any assumption about the geometry of porous adsorbents or operating conditions. Quantitative relations between the differential heat and various isosteres have been established with the grand-canonical Monte Carlo simulation for gas adsorption in amorphous as well as crystalline porous materials. The inconsistencies and practical issues with conventional methods for the analysis of the heat effect have been clarified in the context of the exact results for model systems. Via the resolution of a number of controversies about heat analysis, we hope that the new theoretical procedure will be adopted for both fundamental research and industrial applications of gas adsorption processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluid-Kinetic Coupling: Advanced Discretizations for Simulations on Emerging Heterogeneous Architectures (LDRD FY20-0643)

Plasma physics simulations are vital for a host of Sandia mission concerns, for fundamental science, and for clean energy in the form of fusion power. Sandia's most mature plasma physics simulation capabilities come in the form of particle-in-cell (PIC) models and magnetohydrodynamics (MHD) models. MHD models for a plasma work well in denser plasma regimes when there is enough material that the plasma approximates a fluid. PIC models, on the other hand, work well in lower-density regimes, in which there is not too much to simulate; error in PIC scales as the square root of the number of particles, making high-accuracy simulations expensive. Real-world applications, however, almost always involve a transition region between the high-density regimes where MHD is appropriate, and the low-density regimes for PIC. In such a transition region, a direct discretization of Vlasov is appropriate. Such discretizations come with their own computational costs, however; the phase-space mesh for Vlasov can involve up to six dimensions (seven if time is included), and to apply appropriate homogeneous boundary conditions in velocity space requires meshing a substantial padding region to ensure that the distribution remains sufficiently close to zero at the velocity boundaries. Moreover, for collisional plasmas, the right-hand side of the Vlasov equation is a collision operator, which is non-local in velocity space, and which may dominate the cost of the Vlasov solver. The present LDRD project endeavors to develop modern, foundational tools for the development of continuum-kinetic Vlasov solvers, using the discontinuous Petrov-Galerkin (DPG) methodology, for discretization of Vlasov, and machine-learning (ML) models to enable efficient evaluation of collision operators. DPG affords several key advantages. First, it has a built-in, robust error indicator, allowing us to adapt the mesh in a very natural way, enabling a coarse velocity-space mesh near the homogeneous boundaries, and a fine mesh where the solution has fine features. Second, it is an inherently high-order, high-intensity method, requiring extra local computations to determine so-called optimal test functions, which makes it particularly suited to modern hardware in which floating-point throughput is increasing at a faster rate than memory bandwidth. Finally, DPG is a residual-minimizing method, which enables high-accuracy computation: in typical cases, the method delivers something very close to the $L^2$ projection of the exact solution. Meanwhile, the ML-based collision model we adopt affords a cost structure that scales as the square root of a standard direct evaluation. Moreover, we design our model to conserve mass, momentum, and energy by construction, and our approach to training is highly flexible, in that it can incorporate not only synthetic data from direct-simulation Monte Carlo (DSMC) codes, but also experimental data. We have developed two DPG formulations for Vlasov-Poisson: a time-marching, backward-Euler discretization and a space-time discretization. We have conducted a number of numerical experiments to verify the approach in a 1D1V setting. In this report, we detail these formulations and experiments. We also summarize some new theoretical results developed as part of this project (published as papers previously): some new analysis of DPG for the convection-reaction problem (of which the Vlasov equation is an instance), a new exponential integrator for DPG, and some numerical exploration of various DPG-based time-marching approaches to the heat equation. As part of this work, we have contributed extensively to the Camellia open-source library; we also describe the new capabilities and their usage. We have also developed a well-documented methodology for single-species collision operators, which we applied to argon and demonstrated with numerical experiments. We summarize those results here, as well as describing at a high level a design extending the methodology to multi-species operators. We have released a new open-source library, MLC, under a BSD license; we include a summary of its capabilities as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct simulation Monte Carlo with ionization and radiation

Improvements in the modeling of radiation in low density shock waves with Direct Simulation Monte Carlo (DSMC) are the subject of this study. The physical processes which determine the amount of radiation in a shock wave were investigated and the way in which they were modeled with DSMC was evaluated. Three physical processes were identified for which an improvement in the modeling technique could result in improved radiation predictions. New physical modeling schemes are introduced in this report for the three processes. First a method for determining the electric field and its effect on the flow is introduced. Second, a two step reaction process for electron impact ionization reactions is evaluated. Finally, a new scheme to determine the relaxation collision numbers for excitation of electronic states is proposed. Each new scheme attempts to move the DSMC method toward more accurate physics or more reliance on experimental data. The new schemes are all compared to the current modeling techniques and the differences in the results are evaluated. In all cases the results agree with the available data as well as, or better than the results from earlier schemes.

Carlson, Ann B.↗

SU-E-T-591: Measurement and Monte Carlo Simulation of Stray Neutrons in Passive Scattering Proton Therapy: Needs and Challenges

Purpose: Measure stray radiation inside a passive scattering proton therapy facility, compare values to Monte Carlo (MC) simulations and identify the actual needs and challenges. Methods: Measurements and MC simulations were considered to acknowledge neutron exposure associated with 75 MeV ocular or 180 MeV intracranial passively scattered proton treatments. First, using a specifically-designed high sensitivity Bonner Sphere system, neutron spectra were measured at different positions inside the treatment rooms. Next, measurement-based mapping of neutron ambient dose equivalent was fulfilled using several TEPCs and rem-meters. Finally, photon and neutron organ doses were measured using TLDs, RPLs and PADCs set inside anthropomorphic phantoms (Rando, 1 and 5-years-old CIRS). All measurements were also simulated with MCNPX to investigate the efficiency of MC models in predicting stray neutrons considering different nuclear cross sections and models. Results: Knowledge of the neutron fluence and energy distribution inside a proton therapy room is critical for stray radiation dosimetry. However, as spectrometry unfolding is initiated using a MC guess spectrum and suffers from algorithmic limits a 20% spectrometry uncertainty is expected. H*(10) mapping with TEPCs and rem-meters showed a good agreement between the detectors. Differences within measurement uncertainty (10–15%) were observed and are inherent to the energy, fluence and directional response of each detector. For a typical ocular and intracranial treatment respectively, neutron doses outside the clinical target volume of 0.4 and 11 mGy were measured inside the Rando phantom. Photon doses were 2–10 times lower depending on organs position. High uncertainties (40%) are inherent to TLDs and PADCs measurements due to the need for neutron spectra at detector position. Finally, stray neutrons prediction with MC simulations proved to be extremely dependent on proton beam energy and the used nuclear models and cross sections. Conclusion: This work highlights measurement and simulation limits for ion therapy radiation protection applications.

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo computer simulation of sedimentation of charged hard spherocylinders

In this article we present a NVT Monte Carlo computer simulation study of sedimentation of an electroneutral mixture of oppositely charged hard spherocylinders (CHSC) with aspect ratio L/σ = 5, where L and σ are the length and diameter of the cylinder and hemispherical caps, respectively, for each particle. This system is an extension of the restricted primitive model for spherical particles, where L/σ = 0, and it is assumed that the ions are immersed in an structureless solvent, i.e., a continuum with dielectric constant D. The system consisted of N = 2000 particles and the Wolf method was implemented to handle the coulombic interactions of the inhomogeneous system. Results are presented for different values of the strength ratio between the gravitational and electrostatic interactions, Γ = (mgσ)/(e{sup 2}/Dσ), where m is the mass per particle, e is the electron's charge and g is the gravitational acceleration value. A semi-infinite simulation cell was used with dimensions L{sub x} ≈ L{sub y} and L{sub z} = 5L{sub x}, where L{sub x}, L{sub y}, and L{sub z} are the box dimensions in Cartesian coordinates, and the gravitational force acts along the z-direction. Sedimentation effects were studied by looking at every layer formed by the CHSC along the gravitational field. By increasing Γ, particles tend to get more packed at each layer and to arrange in local domains with an orientational ordering along two perpendicular axis, a feature not observed in the uncharged system with the same hard-body geometry. This type of arrangement, known as tetratic phase, has been observed in two-dimensional systems of hard-rectangles and rounded hard-squares. In this way, the coupling of gravitational and electric interactions in the CHSC system induces the arrangement of particles in layers, with the formation of quasi-two dimensional tetratic phases near the surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

60 APPLIED LIFE SCIENCES↗