Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

The electrochemical storage mechanism in oxy-hydroxyfluorinated anatase for sodium-ion batteries

Replacing lithium ions with sodium ions as the charge carriers in rechargeable batteries can induce noticeable differences in the electrochemical storage mechanisms of electrode materials. Many material parameters, such as particle size, morphology, and the presence of defects, are known to further affect the storage mechanism. Here, we report an investigation of how the introduction of titanium vacancies into anatase TiO 2 affects the sodium storage mechanism. From pair distribution function analysis, we observe that sodium ions are inserted into titanium vacancies at the early stage of the discharge process. This is supported by density functional theory calculations, which predict that sodium insertion is more favourable at vacancies than at interstitial sites. Our calculations also show that the intercalation voltage is sensitive to the anion coordination environment of the vacancy. Sodiation to higher concentrations induces a phase transition toward a disordered rhombohedral structure, similar to that observed in defect-free TiO 2 . Finally, we find that the X-ray diffraction pattern of the rhombohedral phase drastically changes depending on the composition and degree of disorder, providing further comprehension on the sodium storage mechanism of anatase.

25 ENERGY STORAGE↗

Design and Techno-Economic Analysis of a 150-MW Hybrid CSP-PV Plant

The interest in concentrated solar power (CSP) has increased significantly over the years since it is dispatchable and requires thermal storage instead of electric storage. When compared to photovoltaics (PV), CSP has a higher Levelized Cost of Electricity (LCOE). In this paper, we present the design of a hybrid power plant using CSP and PV technologies. The hybrid system offers a lower LCOE than CSP but will still have dispatchability. The 150-MW hybrid system consists of 100-MW CSP and 50-MW PV capacity. Furthermore, the CSP system (central receiver system) has a molten salt-based thermal storage of 12 hours. The geographical focus of this study is Pakistan, which is a developing country struggling with energy crises, but which has high solar potential. The hybrid system is modeled using the System Advisor Model (SAM). The results show that by hybridizing CSP with PV, the LCOE can be reduced by 18.5%.

concentrated solar power↗

Monitoring and control requirement definition study for Dispersed Storage and Generation (DSG), volume 1

Twenty-four functional requirements were prepared under six categories and serve to indicate how to integrate dispersed storage generation (DSG) systems with the distribution and other portions of the electric utility system. Results indicate that there are no fundamental technical obstacles to prevent the connection of dispersed storage and generation to the distribution system. However, a communication system of some sophistication is required to integrate the distribution system and the dispersed generation sources for effective control. The large-size span of generators from 10 KW to 30 MW means that a variety of remote monitoring and control may be required. Increased effort is required to develop demonstration equipment to perform the DSG monitoring and control functions and to acquire experience with this equipment in the utility distribution environment.

Source record↗

ThunderSecure: deploying real-time intrusion detection for 100G research networks by leveraging stream-based features and one-class classification network

Nowadays, data generated by large-scale scientific experiments are on the scale of petabytes per month. These data are transferred through dedicated high-bandwidth networks (40/100G) across distributed sites for processing, storage, and analysis. Like general purpose networks, research networks experience intrusions. However, monitoring anomalies in such high-speed network traffics is challenging given current cyber-infrastructure. Moreover, traditional network intrusion detection systems (NIDS) are signature based. However, anomaly patterns are difficult to define and that rulesets are often not updated frequently enough to reflect the changes of attack behaviors. We present ThunderSecure, a high-throughput, unsupervised learning-based intrusions detection system for 100G research networks. ThunderSecure implements an efficient packet processing and detection pipeline using multi-cores and GPUs. It extracts statistical and temporal features from real-time network data streams and feeds them to a one-class anomaly detection network. A baseline of normal distribution will be created based on the training observation. Testing traffic deviated from the learned profile will be marked as anomalies. We trained ThunderSecure on hundreds of billions of science data packets mirrored from two 100G network connections at Fermi National Accelerator Laboratory. The detection performance was evaluated on traffic captured from the same research network days and weeks after the training with different types of attack flows injected. Results show that ThunderSecure can recognize science data traffic captured long after the training and made nearly certain detection on the segment of the streams where anomalous flows were injected.

100G research network↗

Current-Source Solid-State DC Transformer Integrating LVDC Microgrid, Energy Storage, and Renewable Energy Into MVDC Grid

Solid-state DC transformer to integrate low-voltage DC (LVDC) microgrid, wind turbine (WT) generator, photovoltaic (PV), and energy storage (ES) into medium-voltage (MV) direct-current (MVDC) distribution grids is attractive. This paper proposes current-source DC solid-state transformer (SST) for MVDC collection system in WT, PV, and ES farms or as an interface between the MVDC grid and the LVDC microgrid. Compared to conventional current-source converter (CSC) based SSTs, a switch reduction scheme on reverse-blocking device bridges is proposed to reduce device count and the number of devices on the DC-link current path. Importantly, the proposed switch reduction scheme is generic and can be applied to the DC ports of DC-AC, AC-DC, or DC-DC hard-switching or soft-switching CSC-based SSTs. Based on this scheme, the proposed current-source DC SSTs are derived, which have reduced electrolytic-capacitor-less DC-link. The proposed DC SSTs also achieve single-stage isolated DC-DC or DC-AC conversion, full-range zero-voltage switching (ZVS) for main switches, zero-current switching (ZCS) for resonant switches, and controlled dv/dt. The proposed DC SSTs, operating principles, predictive control method, the ZVS, and the controlled dv/dt under voltage buck-boost ranges are verified with MV simulations and an experimental prototype based on SiC MOSFETs, diodes, and a nanocrystalline transformer.

14 SOLAR ENERGY↗

Solar Energy Grid Integration Systems -- Energy Storage (SEGIS-ES).

This paper describes the concept for augmenting the SEGIS Program (an industry-led effort to greatly enhance the utility of distributed PV systems) with energy storage in residential and small commercial applications (SEGIS-ES). The goal of SEGIS-ES is to develop electrical energy storage components and systems specifically designed and optimized for grid-tied PV applications. This report describes the scope of the proposed SEGIS-ES Program and why it will be necessary to integrate energy storage with PV systems as PV-generated energy becomes more prevalent on the nation's utility grid. It also discusses the applications for which energy storage is most suited and for which it will provide the greatest economic and operational benefits to customers and utilities. Included is a detailed summary of the various storage technologies available, comparisons of their relative costs and development status, and a summary of key R&D needs for PV-storage systems. The report concludes with highlights of areas where further PV-specific R&D is needed and offers recommendations about how to proceed with their development.

14 SOLAR ENERGY↗

Capturing the Impact of Storage and Other Flexible Technologies on Electric System Planning

Power systems of the future are likely to require additional flexibility due to the operating characteristics of many clean energy technologies, particularly those relying on renewable energy sources. This subject has been well studied from an operational perspective, but it has been more difficult to incorporate into capacity expansion models (CEMs) that study investment decisions on the decadal scale. The primary purpose of this report is to present new capabilities that were developed for a particular CEM, NREL's Resource Planning Model (RPM), to better reflect the impact of variable wind and solar generation on system operations and resource adequacy, and, complementarily, to model energy-constrained flexibility resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-economic analysis of DC power distribution in commercial buildings

Improvements in building end-use efficiency have significantly reduced the energy intensity of new buildings, but diminishing returns make it a challenge to build very-low energy buildings cost-effectively. A largely untapped efficiency strategy is to improve the efficiency of power distribution within buildings. Direct current (DC) distribution with modern power electronics has the potential to eliminate much of the power conversion loss in alternating current (AC) building distribution networks that include photovoltaics and DC end uses. Previous literature suggests up to 15% energy savings from DC power distribution in very energy efficient buildings with onsite generation and battery storage. This paper extends prior energy modeling of DC versus AC distribution in buildings, to consider the cost of implementing DC systems on a life-cycle basis. A techno-economic analysis framework based on commercially available products that evaluates the cost-effectiveness of DC systems is presented. The analysis is conducted for three commercial building types in two California climate zones and for various PV and battery storage capacities. Monte Carlo simulation is used to compute the payback period and lifecycle cost savings of DC versus AC distribution systems. A future-market scenario is also examined, which evaluates how future efficiency improvements in power converters and changes in electricity tariffs may affect cost savings. This analysis shows that DC systems can be cost-effective in all scenarios that include large capacities of battery storage and onsite solar, whereas for systems without storage, DC distribution is generally not cost-effective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interconnection Requirements for Renewable Generation and Energy Storage in Island Systems: Puerto Rico Example: Preprint

On September 20, 2017, Hurricane Maria made landfall in Puerto Rico, incapacitating the central power system and leaving the entire island without power. To ensure the long-term recovery of Puerto Rico's electric power grid in the most secure and resilient way, the U.S. Department of Energy funded research to develop recommendations for a cohesive new framework of interconnection standards for utility-scale renewable electrical generation and energy storage that ensure cross-technology compatibility and enable high deployment levels without compromising grid reliably, safety, or security. This paper provides a summary of work conducted by the National Renewable Energy Laboratory to analyze and address many shortcomings and areas of improvement to help the Puerto Rico Electric Power Authority (PREPA) establish minimum technical requirements for interconnecting single-technology and hybrid renewable generation because of their importance for PREPA system security and impacts on future integrated resource planning scenarios. Results and findings presented in this paper are important for any island power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

in-situ chemistry mapping of hydrogen storage materials by neutron diffraction

Neutron diffraction was used to nondestructively study the microstructures for two hydrogen storage media systems. In the first case, sodium alanate based hydrogen storage is a vehicle-scale candidate system developed by Sandia/GM. Neutron scattering was used to determine the distribution of phases in the storage media at different hydrogen loading levels, to help understand the absorption/desorption of hydrogen in large-scale systems. This study also included a 3D neutron tomographic study of the microstructure. In the second case, tin-doped lanthanum nickel alloys have been studied at JPL for space-based applications, for which the gradual degradation of the material due to segregation and disproportionation of phases is a known problem. A regenerative process developed to restore the storage properties of these alloys was studied, using in-situ neutron diffraction to relate the microstructure to the thermodynamic simulations.

hydrogen storage↗

Emergency Generation Asset Positioning for Resilient Transmission Grid Operation: Preprint

In this paper we study a problem of hurricane emergency preparedness via placement of emergency generation assets prior to its strike. We present a two-stage stochastic model for choosing locations and quantities of emergency storage to help support the power grid through a hurricane event. The expectation of losses in our two-stage model is estimated using the sample average approximation. We construct damage scenarios for sample average approximation using WIND Toolkit meteorological data and fragility curves of various electric grid components. We demonstrate the efficacy of our two-stage planning model by simulating operations during Hurricane Dolly on the 2000-bus transmission test system. Our model, coupled with our scenario selection strategy, is effective at mitigating loss of load when compared to a model without emergency generation assets placed prior to an extreme event.

emergency preparedness↗

Impact of Quaternary Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Impact of Quaternary-Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations: Preprint

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Transactive Energy Rationing in an Islanded Electric Power System

A battery energy storage system (BESS) has been installed on Nantucket Island to provide service continuity during the N-1 contingency of partial electricity supply interruption from the mainland. During the N-2 contingency of complete interruption from the mainland, most of the loads will have to be disconnected so that a combustion gas turbine (CTG) can supply critical facilities. This work proposes an alternative transactive rationing mechanism that would provide some service to all of the loads, and still fully serve the critical loads, through market-based control during the N-2 contingency. A BESS operating strategy is proposed that would enhance the transactive rationing mechanism. The necessary enabling changes to communication systems, controls and utility tariffs are discussed, along with some ancillary benefits.

transactive energy, power distribution, energy sto↗

Surface Atomic Rearrangement with High Cation Ordering for Ultra-Stable Single-Crystal Ni-Rich Co-Less Cathode Materials

It is crucial to minimize cobalt content in Ni-rich layered single-crystal cathodes due to their high price and limited availability, yet it will inevitably lead to cation disordering, capacity degradation, and thermal issues. Herein, to overcome the intrinsic trade-off between performance and composition of Ni-rich Co-less single-crystal cathodes, a precursor engineering strategy with an epitaxially grown cobalt enrichment on the surface is innovatively proposed. In contrast to traditional coating modifications with random orientation and rigid surface-bulk boundary, the epitaxially enriched surface cobalt layer on the precursor undergoes rapid interdiffusion with the internal Ni 3+ during the optimized sintering process. This interdiffusion eliminates the surface-bulk boundary, promoting the uniform distribution of cobalt and synergistically addressing the Li/Ni intermixing. Moreover, an enhanced surface Li + diffusion is obtained, thereby suppressing the Li + concentration gradient and intragranular cracks generation. Consequently, the modified LiNi 0.7 Co 0.07 Mn 0.23 O 2 exhibits impressive cycling stability with increased capacity retention in both coin-type half-cells and pouch-type full-cells (91% after 1000 cycles), even under the harsh condition of high-temperature, surpassing the majority of previously reported Ni-rich cathodes. Finally, this work opens new avenues toward the low cost, high energy density, thermal stability, and long cyclic life for Ni-rich Co-less cathodes and sheds light on large-scale commercial production.

25 ENERGY STORAGE↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using distributed temperature sensing to detect CO 2 leakage along the injection well casing

The objective of this study is to evaluate the sensitivity of Distributed Temperature Sensing (DTS) data to detect CO 2 leakage along an injection well casing. This paper describes the relationship between the CO 2 leakage rate and temperature response at DTS locations, and the method and numerical model used for understanding such a relationship. The uncertainties in the parameters are propagated to the interpretation of DTS measurements, which may lead to false positive and false negative identifications of CO 2 leakage. We propose to identify CO 2 leakage by analyzing both temperature history plots at selected vertical locations as well as the vertical temperature profiles at different times. The analysis should be combined with numerical simulations for the estimation of leakage rates. In addition, leakage needs to be confirmed by data from a warm-up test (temperature recovery after injection of cold CO 2 is stopped) to minimize the probability of false identifications.

42 ENGINEERING↗