Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Thermophotovoltaic Cell Technology Transferred to the Department of Energy Laboratory and a Commercial Manufacturer

Researchers in the NASA Lewis Research Center's Photovoltaic Branch have developed novel photovoltaic device, called a Monolithically Interconnected Module (MIM), for use in thermophotovoltaic (TPV) power systems. TPV power systems function by heating an emitter to produce light. This light is then converted into electricity by a photovoltaic device or a solar cell. Possible heat sources for the system include concentrated solar energy, the combustion of various fuels, and nuclear decay. NASA has an interest in TPV systems for deep space (nuclear-powered) and near-Sun (solar-powered) missions. There also are many commercial and military applications for TPV, given its potential for high efficiency, low noise, and reliable power. The Monolithically Interconnected Module consists of many small solar cells that are series-interconnected on a common substrate. The cells are fabricated from indium gallium arsenide (InGaAs), which can convert the near-infrared portion of the emitter output spectrum into electricity. The InGaAs devices are deposited on an indium phosphide (InP) substrate that provides electrical isolation. On the bottom the InP substrate is an infrared reflector that returns all the photons that are not converted by the InGaAs device back to the emitter where they are absorbed. This process helps maintain the emitter temperature and dramatically improves the system efficiency. Monolithically Interconnected Module InGaAs thermophotovoltaic cell developed by Lewis. Compared with conventional TPV cells, this TPV device has higher output voltages and lower resistive losses, higher output power density, simplified thermal management, improved reliability, and higher efficiency. The Monolithically Interconnected Module was initially developed under an internally funded effort (Director's Discretionary Fund). Development is now being funded by another government agency, and prototype devices are being produced by a commercial solar cell manufacturer.

Wilt, David M.↗

A Global Real-Time Superlab: Enabling High Penetration of Power Electronics in the Electric Grid

The Global Real-Time Superlaboratory (Global RT Superlab) represents a vendor-neutral distributed platform based on the virtual interconnection of digital real-time simulators (DRTSs) and hardware-in-the-loop (HIL) setups hosted at eight geographically distributed laboratories in the United States and Europe (Figure 1). This article describes the efforts toward the realization of this largescale virtual infrastructure and explains a demonstration of the multilab setup for simulation and testing of next-generation global power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predicting the Reliability of Solar-Cell Interconnections

The reduction of life expectancy by thermal cycling calculated during design. Connections between solar cells critical parts of solarcell arrays generating electric power. Reliability affects life expectancy of modules, panels, and arrays. Used to predict stress-cycle lifetimes of such structures as arches, walkways, cylindrical ribbing of aircraft fuselages and submarine hulls, and pipeline expansion loops. Testing costs reduced by about 90 percent.

Mon, G. R.↗

Post-remediation geophysical assessment: Investigating long-term electrical geophysical signatures resulting from bioremediation at a chlorinated solvent contaminated site

There is a growing need to assess long-term impacts of active remediation strategies on treated aquifers. A variety of biogeochemical alterations can result from interactions of the amendment with the aquifer, conceivably leading to a geophysical footprint of the long-term alteration of an aquifer. This concept of post-remediation geophysical assessment was investigated in a shallow, chlorinated solvent-contaminated aquifer six to eight years after amendment delivery. Surface resistivity imaging and cross-borehole resistivity and induced polarization (IP) imaging were performed on a transect that spanned treated and untreated zones of the aquifer. Established relationships between IP parameters and surface electrical conductivity were used to predict vertical profiles of electrolytic conductivity and surface conductivity from the inverted cross-borehole images. Aqueous geochemistry data, along with natural gamma and magnetic susceptibility logs, were used to constrain the interpretation. The electrical conductivity structure determined from surface and borehole imaging was foremost controlled by the electrolytic conductivity of the interconnected pore space, being linearly related to fluid specific conductance. The electrolytic conductivity (and thus the conductivity images alone) did not discriminate between treated and untreated zones of the aquifer. In contrast, inverted phase angles and surface conductivities did discriminate between treated and untreated zones of the aquifer, with the treated zone being up to an order of magnitude more polarizable in places. Supporting aqueous chemistry and borehole logging datasets indicate that this geophysical footprint of the long-term impact of the remediation on the aquifer is most likely associated with the formation of polarizable, dispersed iron sulfide minerals. The study opens the door to the possibility of employing time-lapse electrical geophysical measurements to assist with long-term environmental stewardship of legacy sites undergoing active remediation.

bioremediation↗

Developing a Reduced 240-Bus WECC Dynamic Model for Frequency Response Study of High Renewable Integration

The ongoing changes in the generation resource mix, driven by the rapid adoption of inverter-based resources (IBR) as well as the early retirement of synchronous generators, are bringing new challenges to the planning and operation of bulk electric power systems. Consequently, there is an increasing need to understand, design, and quantify the reliability service provision from IBRs by performing integrated scheduling and dynamic simulations. However, test systems that have consistent scheduling and dynamic models rarely exist largely because of the decoupled nature of the two simulations on a synchronous generator-dominated system. This paper develops the dynamic model of a reduced Western Electricity Coordinating Council (WECC) system. In conjunction with the existing scheduling model, it is suitable for integrating scheduling and dynamic simulations. The reduced 240-bus WECC model reflects the generation resource mix of the Western Interconnection as of 2018. Moreover, the developed dynamic model is validated against field frequency events measured by FNET/GridEye and preserves the dominant inter-area oscillation mode in WECC.

dynamic simulation↗

Electrically tunable superconducting terahertz metamaterial with low insertion loss and high switchable ratios

With the emergence and development of artificially structured electromagnetic materials, active terahertz (THz) metamaterial devices have attracted significant attention in recent years. Tunability of transmission is desirable for many applications. For example, short-range wireless THz communications and ultrafast THz interconnects require switches and modulators. However, the tunable range of transmission amplitude of existing THz metamaterial devices is not satisfactory. In this article, we experimentally demonstrate an electrically tunable superconducting niobium nitride metamaterial device and employ a hybrid coupling model to analyze its optical transmission characteristics. The maximum transmission coefficient at 0.507 THz is 0.98 and decreases to 0.19 when the applied voltage increases to 0.9 V. A relative transmittance change of 80.6% is observed, making this device an efficient narrowband THz switch. Additionally, the frequency of the peak is red shifted from 0.507 to 0.425 THz, which means that the device can be used to select the frequency. This study offers an alternative tuning method to existing optical, thermal, magnetic-field, and electric-field tuning, delivering a promising approach for designing active and miniaturized THz devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The value of long-duration energy storage under various grid conditions in a zero-emissions future

Long-duration energy storage (LDES) is a key resource in enabling zero-emissions electricity grids but its role within different types of grids is not well understood. Using the Switch capacity expansion model, we model a zero-emissions Western Interconnect with high geographical resolution to understand the value of LDES under 39 scenarios with different generation mixes, transmission expansion, storage costs, and storage mandates. We find that a) LDES is particularly valuable in majority wind-powered regions and regions with diminishing hydropower generation, b) seasonal operation of storage becomes cost-effective if storage capital costs fall below US$\$$5 kWh −1 , and c) mandating the installation of enough LDES to enable year-long storage cycles would reduce electricity prices during times of high demand by over 70%. Given the asset and resource diversity of the Western Interconnect, our results can provide grid planners in many regions with guidance on how LDES impacts and is impacted by energy storage mandates, investments in LDES research and development, and generation mix and transmission expansion decisions.

25 ENERGY STORAGE↗

Back-contacted bottom cells with three terminals: Maximizing power extraction from current-mismatched tandem cells

Multi-junction cells can significantly improve the energy yield of photovoltaic systems over a single-junction cell. The internal interconnection scheme of the subcells is an important aspect in determining the resulting levelized cost of electricity. For a dual-junction cell, two approaches are commonly discussed: series-connected tandem cells with two terminals or independently working subcells in a four-terminal (4T) tandem device. In this paper, we explore the working principle and the operation modes of a third, rarely discussed option: a three-terminal (3T) tandem cell using a back-contacted bottom cell with 3Ts. We use current-voltage measurements of illuminated 3T interdigitated back contact cells and confirm that the front and rear base contacts are at similar quasi-Fermi level positions, which enables the bottom cell to either efficiently collect surplus carriers, in the case of a current-limiting or carrier injecting top cell, or inject majority carriers, in the case of a current-limiting bottom cell. As a result, no current matching is needed. The power output of an idealized 3T bottom cell without resistive effects is independent of the current density applied from the top cell. These characteristics of the 3T bottom cells enable a 3T tandem to operate as efficiently as a 4T tandem, while being compatible with monolithic design and not requiring intermediate grids. We propose a simple equivalent circuit model including additional resistive effects, which describes a real 3T bottom cell and achieves excellent agreement to the experiment. We deduce design guidelines for a 3T bottom cell in different operation regimes.

14 SOLAR ENERGY↗

In Situ Synthesis of 3D Interconnected Graphene-Reinforced Copper Composites

Graphene shows great potential in composite applications, but the performance of traditional graphene-metal composites is poorer than desired due to the uneven dispersion of graphene in the matrix. This study provides an effective method to grow high-quality graphene on the surface of 3D porous copper using a combination of chemical vapor deposition and spark plasma sintering to obtain a dense 3D-interconnected graphene/Cu composite. Transmission electron microscopy and scanning electron microscopy showed that graphene-coated copper and Raman analysis showed high-quality graphene. The tensile strength of the 3D graphene/Cu composite was 425 MPa, which is ~ 25% higher than that of pure Cu, and the coefficient of friction (0.33) is about 45% lower than that of pure Cu (0.58). The formation of high-quality 3D graphene interconnects in the Cu matrix results in a higher mechanical strength, better friction properties and superior electrical and thermal conductivity of the composite compared to those of pure Cu.

36 MATERIALS SCIENCE↗

Regional Inertia Estimation Using Actual Event Measurements: Florida Case

As inverter-based resources’ integration in power grids increases, their uneven distribution across the electrical network leads to the formation of local regions that are weakly coupled to the larger interconnection. This signifies the necessity of regional frequency dynamics investigation and analyzing various inertia metrics. This paper presents a practical methodology for estimating regional rate-of-change of frequency (RoCoF) using actual event recordings, which is then used to evaluate regional inertia. Florida (FL) is selected as the region of interest due to its distinct regional frequency dynamics and the rising levels of solar generation. We identify and analyze confirmed events from 2017 to 2024 that occurred in FL. The results indicate that FL contributes about 14% to the total inertia of the US Eastern Interconnection, which approximately matches its share of generation capacity. Results also highlight seasonal fluctuations in energy generation, which play a significant role in influencing inertia and thus the RoCoF levels. This emphasizes the importance of estimating regional inertia to enhance grid operations for a future that focuses on distributed generation.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Cost Benefit and Alternatives Analysis of Distribution Systems with Energy Storage Systems: Preprint

This paper explores monetized and non-monetized benefits from storage interconnected to distribution system through use cases illustrating potential applications for energy storage in California's electric utility system. This work supports SDG&E in its efforts to quantify, summarize, and compare the cost and benefit streams related to implementation and operation of energy storage on its distribution feeders. This effort develops the cost benefit and alternatives analysis platform, integrated with QSTS feeder simulation capability, and analyzed use cases to explore the cost-benefit of implementation and operation of energy storage for feeder support and market participation.

25 ENERGY STORAGE↗

Enabling Resiliency Operations across Multiple Microgrids with Grid Friendly Appliance Controllers

Changes in economic, technological, and environmental policies are resulting in a re-evaluation of the dependence on large central generation facilities and their associated transmission networks. Emerging concepts of smart communities/cities are examining the potential to leverage cleaner sources of generation, as well as integrating electricity generation with other municipal functions. When grid connected, these generation assets can supplement the existing interconnections with the bulk transmission system, and in the event of an extreme event, they can provide power via a collection of microgrids. To achieve the highest level of resiliency, it may be necessary to conduct switching operations to interconnect individual microgrids. While the interconnection of multiple microgrids can increase the resiliency of the system, the associated switching operations can cause large transients in low inertia microgrids. The combination of low system inertia and IEEE 1547 and 1547a-compliant inverters can prevent multiple microgrids from being interconnected during extreme weather events. This study will present a method of using end-use loads equipped with Grid Friendly™ Appliance controllers to facilitate the switching operations between multiple microgrids; operations that are necessary for optimal operations when islanded for resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient off-grid microgrids: Capacity planning and N-1 security

Over the past century the electric power industry has evolved to support the delivery of power over long distances with highly interconnected transmission systems. Despite this evolution, some remote communities are not connected to these systems. These communities rely on small, disconnected distribution systems, i.e., microgrids to deliver power. However, as microgrids often are not held to the same reliability standards as transmission grids, remote communities can be at risk for extended blackouts. To address this issue, we develop an optimization model and an algorithm for capacity planning and operations of microgrids that include N-1 security and other practical modeling features like AC power flow physics, component efficiencies and thermal limits. Lastly, we demonstrate the computational effectiveness of our approach on two test systems; a modified version of the IEEE 13 node test feeder and a model of a distribution system in a remote community in Alaska.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliability, Resilience and the Oncoming Wave of Retiring Baseload Units, Volume I: The Critical Role of Thermal Units During Extreme Weather Events

This study examines the cold weather event now known as the Bomb Cyclone that blanketed much of the eastern half of the United States from Dec 27, 2017 through Jan 8, 2018. Analyses focus on six areas of organized markets administered by independent system operators in the US Eastern Interconnection and Texas. This report finds: (1) Combined, fossil and nuclear energy plants provided 89% of electricity during peak demand across all the ISOs; (2) Coal provided the most resilient form of generation in PJM; (3) The value of fuel-based power generation resilience in PJM during this event was estimated at $3.5 billion; (4) Natural gas price spikes, increased demand, and pipeline constraints led to significant fuel oil burn in the US Northeast; (5) Renewables imposed a resilience penalty on the system as output decreased as demand increased; (6) Underestimation of coal and nuclear retirements could give rise to reliability concerns and an inability to meet projected electricity demand.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy 101: Utilities [Slides]

The Energy 101: Utilities presentation, developed for the Energy Technology Innovation Partnership Project (ETIPP), provides an overview of utilities. It covers fundamental concepts, technologies, considerations, case studies, and additional resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Considerations and Research Pathways for Grid-Interactive Efficient Buildings

Federal facilities serve critical missions and functions that require safe, reliable, and efficient operations. Digitization of several facility operations has increased the cost-effectiveness of energy usage and optimization of energy system performance. As the building controls landscape shifts to become more connected and smarter, building operators now face unique opportunities and challenges to adopt smart enabled devices that can lower energy usage while also optimizing building system performance. The grid-interactive efficient buildings (GEB) initiative aims to make buildings cleaner and more flexible through these smart devices. Smart enabled devices allow greater connectivity and control through remote operations and provide crucial data for analytics and increased efficiency. GEBs enable demand flexibility that has the potential to reduce electrical costs and transform the grid edge where buildings connect to power grids. This operation of interconnected systems, if not designed with cybersecurity practices, causes security gaps and introduces potential attack paths by adversarial and non-adversarial entities leading to disruption of operations.

building controls↗

Performance and durability of electrically conductive tape for shingled Si heterojunction technology cells

We report electrically conductive tape (ECT) was characterized and used to assemble shingled cell strings at low temperature to achieve high reliability Pb- and Ag-free interconnections. The volume resistivity for two considered ECTs are 0.13 ± 0.06 mΩ·cm and 0.47 ± 0.20 mΩ·cm and specific contact resistances, 6.85± 2.00 mΩ·cm 2 and 6.30 ± 0.37 mΩ·cm 2 using the emerging IEC 62788-8-1 Technical Specification for assessment of electrically conductive adhesives (ECA). Durability and performance of the technology in glass–glass mini modules were evaluated with temperature cycling, damp heat testing, and combined-accelerated stress testing (CAST). Through temperature cycling (-40°C to 85°C) applying five times the mini module short-circuit current in forward bias and in the multi climate CAST protocol, there was negligible degradation of fill factor after replacing connectors at the modules' cable leads; however, CAST resulted in short circuit current loss attributed to degradation in light collection by the cells, not the ECT. The IEC 61215-2 85°C, 85% relative humidity damp heat testing showed susceptibility of the HJT cells to effects of humidity in the electroluminescence intensity around the module perimeter that degraded power performance by 4% (relative). Contrasting the IEC 61215-2 qualification testing-based damp heat testing with CAST, factors such as the optical stress of CAST may precipitate the degradation of the modules whereas the humidity levels and duration of IEC 61215-2 damp heat testing may lead to excessive levels of humidity diffused into the modules, potentially resulting in degradation that is unrepresentative of the field.

14 SOLAR ENERGY↗