Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Design and investigations of the superconducting magnet system for the multipurpose superconducting electron cyclotron resonance ion source

The production of intense beams of heavy ions with electron cyclotron resonance ion sources (ECRIS) is an important request at many accelerators. According to the ECR condition and considering semi-empirical scaling laws, it is essential to increase the microwave frequency together with the magnetic flux density of the ECRIS magnet system. A useful frequency of 28 GHz, therefore, requires magnetic flux densities above 2.2 T implying the use of superconducting magnets. A cooperation of European institutions initiated a project to build a multipurpose superconducting ECRIS (MS-ECRIS) in order to achieve an increase of the performances in the order of a factor of ten. After a first design of the superconducting magnet system for the MS-ECRIS, the respective cold testing of the built magnet system reveals a lack of mechanical performance due to the strong interaction of the magnetic field of the three solenoids with the sextupole field and the magnetization of the magnetic iron collar. Comprehensive structural analysis, magnetic field calculations, and calculations of the force pattern confirm thereafter these strong interactions, especially of the iron collar with the solenoidal fields. The investigations on the structural analysis as well as suggestions for a possible mechanical design solution are given.

43 PARTICLE ACCELERATORS↗

Extraction Simulations and Emittance Measurements of a Holifield Radioactive Ion Beam Facility Electron Beam Plasma Source for Radioactive Ion Beams

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

Liu, Yuan↗

X-ray-optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser

X-ray-optical pump-probe experiments at the Linac Coherent Light Source (LCLS) have so far been limited to a time resolution of 280 fs fwhm due to timing jitter between the accelerator-based free-electron laser (FEL) and optical lasers. We have implemented a single-shot cross-correlator for femtosecond x-ray and infrared pulses. A reference experiment relying only on the pulse arrival time information from the cross-correlator shows a time resolution better than 50 fs fwhm (22 fs rms) and also yields a direct measurement of the maximal x-ray pulse length. The improved time resolution enables ultrafast pump-probe experiments with x-ray pulses from LCLS and other FEL sources.

43 PARTICLE ACCELERATORS↗

A setup for resonant inelastic soft x-ray scattering on liquids at free electron laser light sources

We present a flexible and compact experimental setup that combines an in vacuum liquid jet with an x-ray emission spectrometer to enable static and femtosecond time-resolved resonant inelastic soft x-ray scattering (RIXS) measurements from liquids at free electron laser (FEL) light sources. We demonstrate the feasibility of this type of experiments with the measurements performed at the Linac Coherent Light Source FEL facility. At the FEL we observed changes in the RIXS spectra at high peak fluences which currently sets a limit to maximum attainable count rate at FELs. The setup presented here opens up new possibilities to study the structure and dynamics in liquids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the energy distribution of electrons escaping confinement from an electron cyclotron resonance ion source

Production of high charge state ions in electron cyclotron resonance ion sources (ECRISs) is dependent on the electron energy distribution (EED) within the source plasma. In order to better understand the EED, a measurement of electrons escaping axially from an ECRIS device has been performed at the National Superconducting Cyclotron Laboratory. Electrons were measured escaping from the Superconducting Source for Ions, driven at 18 GHz. Dependencies of the observed EED on the confining magnetic field strength and injected microwave power are reported. This paper focuses on large peaks of electrons in the 400–1200 keV energy range. Measurements of the axial bremsstrahlung spectrum have been simultaneously carried out to provide a direct comparison between both techniques. A comparison between the energy associated with the peak of the electron distribution and the spectral temperature of the bremsstrahlung distribution is shown.

47 OTHER INSTRUMENTATION↗

Studies on x-ray and UV emissions in electron cyclotron resonance x-ray source

A novel electron cyclotron resonance x-ray source is constructed based on the ECR technique. In this paper, the possibility of using the ECR x-ray source for producing UV rays by optimizing the plasma parameters is explored. X-ray and UV emissions from the ECR x-ray source are carried out for argon, nitrogen, and CO{sub 2} plasma. The x-ray spectral and dose measurements are carried with NaI(Tl) based spectrometer and dosimeter, respectively. For UV measurement, a quartz window arrangement is made at the exit port and the UV intensity is measured at 5 cm from the quartz plate using UV meter. The x-ray and UV emissions are carried out for different microwave power levels and gas pressures. The x-ray emission is observed in the pressure range {<=}10{sup -5} Torr, whereas the UV emission is found to be negligible for the gas pressures <10{sup -5} Torr and it starts increasing in the pressure range between 10{sup -5} and 10{sup -3} Torr. At high-pressure range, collision frequency of electron-atom is large which leads to the higher UV flux. At low pressure, the electron-atom collision frequency is low and hence the electrons reach high energy and by hitting the cavity wall produces higher x-ray flux. By choosing proper experimental conditions and plasma gas species, the same source can be used as either an x-ray source or an UV source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam extraction and high stability operation of high current electron cyclotron resonance proton ion source

A high current electron cyclotron resonance proton ion source is designed and developed for the low energy high intensity proton accelerator at Bhabha Atomic Research Centre. The plasma discharge in the ion source is stabilized by minimizing the reflected microwave power using four stub auto tuner and magnetic field. The optimization of extraction geometry is performed using PBGUNS code by varying the aperture, shape, accelerating gap, and the potential on the electrodes. While operating the source, it was found that the two layered microwave window (6 mm quartz plate and 2 mm boron nitride plate) was damaged (a fine hole was drilled) by the back-streaming electrons after continuous operation of the source for 3 h at beam current of 20–40 mA. The microwave window was then shifted from the line of sight of the back-streaming electrons and located after the water-cooled H-plane bend. In this configuration the stable operation of the high current ion source for several hours is achieved. The ion beam is extracted from the source by biasing plasma electrode, puller electrode, and ground electrode to +10 to +50 kV, −2 to −4 kV, and 0 kV, respectively. The total ion beam current of 30–40 mA is recorded on Faraday cup at 40 keV of beam energy at 600–1000 W of microwave power, 800–1000 G axial magnetic field and (1.2–3.9) × 10{sup −3} mbar of neutral hydrogen gas pressure in the plasma chamber. The dependence of beam current on extraction voltage, microwave power, and gas pressure is investigated in the range of operation of the ion source.

43 PARTICLE ACCELERATORS↗

Experimental evidences for emittance degradation by space charge effect when using a focusing solenoid below an electron cyclotron resonance ion source

Solenoids are widely used to provide initial focusing of beams extracted from an ion source. However, in the case of an electron cyclotron resonance (ECR) ion source, the extracted beam will usually include different ion species and for each of them a wide distribution of charge states. When such a multicomponent beam is focused by a solenoid, the ions with a Q/A larger than the beam of interest are overfocused and usually go through a waist before reaching the analyzing magnet. If the beam currents obtained for these ions are sufficient, the resulting space charge forces can significantly degrade the emittance of the beam components with a lower Q/A and result for those in a hollow beam. Using a beam viewer and an emittance-measuring device, this paper reports on experimental findings that confirm the existence of such an effect for low charge states of argon. Moreover, by changing the experimental conditions of the ECR plasma in order to modify the charge state distribution of the extracted ion beam, it is shown that the threshold where this space charge effect starts to be significant can be changed.

43 PARTICLE ACCELERATORS↗

Development of DRAGON electron cyclotron resonance ion source at Institute of Modern Physics

A new room temperature electron cyclotron resonance (ECR) ion source, DRAGON, is under construction at IMP. DRAGON is designed to operate at microwaves of frequencies of 14.5-18 GHz. Its axial solenoid coils are cooled with evaporative medium to provide an axial magnetic mirror field of 2.5 T at the injection and 1.4 T at the extraction, respectively. In comparison to other conventional room temperature ECR ion sources, DRAGON has so far the largest bore plasma chamber of inner diameter of 126 mm with maximum radial fields of 1.4-1.5 T produced by a non-Halbach permanent sextupole magnet.

43 PARTICLE ACCELERATORS↗

Development and calibration of mirrors and gratings for the Soft X-ray materials science beamline at the Linac Coherent Light Source free-electron laser

This article discusses the development and calibration of the x-ray reflective and diffractive elements for the Soft X-ray Materials Science (SXR) beamline of the Linac Coherent Light Source (LCLS) free-electron laser (FEL), designed for operation in the 500 – 2000 eV region. The surface topography of three Si mirror substrates and two Si diffraction grating substrates was examined by atomic force microscopy (AFM) and optical profilometry. The figure of the mirror substrates was also verified via surface slope measurements with a long trace profiler. A boron carbide (B 4 C) coating especially optimized for the LCLS FEL conditions was deposited on all SXR mirrors and gratings. Coating thickness uniformity of 0.14 nm root mean square (rms) across clear apertures extending to 205 mm length was demonstrated for all elements, as required to preserve the coherent wavefront of the LCLS source. The reflective performance of the mirrors and the diffraction efficiency of the gratings were calibrated at beamline 6.3.2 at the Advanced Light Source synchrotron. To verify the integrity of the nanometer-scale grating structure, the grating topography was examined by AFM before and after coating. This is to our knowledge the first time B 4 C-coated diffraction gratings are demonstrated for operation in the soft x-ray region.

36 MATERIALS SCIENCE↗

Hot electron preheat effects in two-photon polymerization plastic lattice laser-driven shock-tube experiments on the OMEGA laser

We present simulations of Omega shock tube experiments designed to investigate hot electron preheat effects in 3D-printed, two-photon polymerization (2PP) plastic lattices. Preheat is inferred in the experiments from the expansion of a plastic witness disk embedded in the lattice. Using the Eulerian radiation-hydrodynamics code xRAGE, we model shock propagation and preheat from both radiative and hot electron energy sources to evaluate their relative impact. To simulate the transport of laser-generated hot electrons, the nonlocal electron heat transport model proposed by Schurtz, Nicolaï, and Busquet (SNB) is extended with a hot electron source term and an energy cascade algorithm. We explore how variations in ablator, lattice geometry, and laser drive affect the shock velocity and witness disk expansion. Simulations show that the inclusion of a 5 μm gold layer reduces shock pressure by 60% and shock speeds by 30%–40% but does not significantly reduce the hot electron preheat, and that different lattice geometries lead to enhanced shock velocities—up to 40% faster than in homogeneous foams. However, radiative and conductive preheat from classical mechanisms alone fail to match experiment. By including a hot electron source term, we reproduce experimental observables such as disk expansion rates and spatial radiographic features. We find that a hot electron population corresponding to 4%–8% of the incident laser energy with T hot = 50 keV produces expansion which agrees with the experimental data, suggesting hot electron preheat is the most plausible explanation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Laser Particle Accelerator Development at LANL: From Fast Ignition to Radiation Oncology

Laser-plasma accelerated ion and electron beam sources are an emerging field with vast prospects, and promise many superior applications in a variety of fields such as hadron cancer therapy, compact radioisotope generation, table-top nuclear physics, laboratory astrophysics, nuclear forensics, waste transmutation, Special Nuclear Material (SNM) detection, and inertial fusion energy. LANL is engaged in several projects seeking to develop compact high-current and high-energy ion and electron sources. We are especially interested in two specific applications: ion fast ignition/capsule perturbation and radiation oncology. Laser-to-beam conversion efficiencies of over 10% are needed for practical applications, and we have already shown inherent efficiencies of >5% from flat foils, on Trident using only a 5th of the intensity and energy of the Nova Petawatt laser. With clever target designs, like structured curved cone targets, we have also been able to achieve major ion energy gains, leading to the highest energy laser-accelerated proton beams in the world [3]. These new target designs promise to help usher in the next generation of particle sources realizing the potential of laser-accelerated beams.

43 PARTICLE ACCELERATORS↗

Status of a compact electron cyclotron resonance ion source for National Institute of Radiological Sciences-930 cyclotron

The Kei-source is a compact electron cyclotron resonance ion source using only permanent magnets and a frequency of 10 GHz. It was developed at the National Institute of Radiological Sciences (NIRS) for producing C{sup 4+} ions oriented for high-energy carbon therapy. It has also been used as an ion source for the NIRS-930 cyclotron. Its microwave band region for the traveling-wave-tube amplifier and maximum output power are 8–10 GHz and 350 W, respectively. Since 2006, it has provided various ion beams such as proton, deuteron, carbon, oxygen, and neon with sufficient intensity (200 μA for proton and deuteron, 50 μA for C{sup 4+}, for example) and good stability for radioisotope production, tests of radiation damage, and basic research experiments. Its horizontal and vertical emittances were measured using a screen monitor and waist-scan. The present paper reports the current status of the Kei-source.

07 ISOTOPE AND RADIATION SOURCES↗

Sources of Primary Electrons in Nanosecond Pulsed Breakdown in Water (Final Technical Report)

Electrical breakdown of liquid dielectrics under ns or sub-ns pulsed electric field has been studied extensively in the last decade. Summarized in [7], this relatively young research area makes significant contributions to the theories of liquid breakdown by introducing a new mechanism (electrostrictive cavitation) that is unique at the ns timescale. It is also fundamentally important to plasma sources for biomedical applications and insulation of pulsed power equipment. For water in particular, the understanding of the mechanisms and processes of ns/sub-ns breakdown also sheds new light on cavitation studies, one of the most exciting areas of modern fluid mechanics. The objective of this collaborative research with PCRF was to construct a complete picture of the physical mechanisms and processes at the initial phase of electrical breakdown in liquid dielectrics under nanosecond (ns) pulsed inhomogeneous fields. The research funded by the initial award DE‐ SC0021182 aimed to address the sources of primary electrons in ns breakdown in water, which led to one journal publication and multiple conference presentations. The PI also gave presentations to the PPPL/PCRF audience twice, one in October 2020 and the other during the 2021 PCRF Annual Meeting

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron cyclotron resonance ion sources in use for heavy ion cancer therapy

The use of electron cyclotron resonance (ECR) ion sources for producing ion beams for heavy ion cancer therapy has been established for more than ten years. After the Heavy Ion Medical Accelerator (HIMAC) at Chiba, Japan started therapy of patients with carbon ions in 1994 the first carbon ion beam for patient treatment at the accelerator facility of GSI was delivered in 1997. ECR ion sources are the perfect tool for providing the required ion beams with good stability, high reliability, and easy maintenance after long operating periods. Various investigations were performed at GSI with different combinations of working gas and auxiliary gas to define the optimal beam conditions for an extended use of further ion species for the dedicated Heidelberg Ion Beam Therapy (HIT) facility installed at the Radiological University Hospital Heidelberg, Germany. Commercially available compact all permanent magnet ECR ion sources operated at 14.5 GHz were chosen for this facility. Besides for {sup 12}C{sup 4+} these ion sources are used to provide beams of {sup 1}H{sub 3}{sup 1+}, {sup 3}He{sup 1+}, and {sup 16}O{sup 6+}. The final commissioning at the HIT facility could be finished at the end of 2006.

43 PARTICLE ACCELERATORS↗

Electron-beam-based sources of ultrashort x-ray pulses

A review of various methods for generation of ultrashort X-ray pulses using relativistic electron beam from conventional accelerators is presented. Both spontaneous and coherent emission of electrons are considered.

43 PARTICLE ACCELERATORS↗

The LAMP instrument at the Linac Coherent Light Source free-electron laser

The Laser Applications in Materials Processing (LAMP) instrument is a new end-station for soft X-ray imaging, high-field physics, and ultrafast X-ray science experiments that is available to users at the Linac Coherent Light Source (LCLS) free-electron laser. While the instrument resides in the Atomic, Molecular and Optical science hutch, its components can be used at any LCLS beamline. The end-station has a modular design that provides high flexibility in order to meet user-defined experimental requirements and specifications. The ultra-high-vacuum environment supports different sample delivery systems, including pulsed and continuous atomic, molecular, and cluster jets; liquid and aerosols jets; and effusive metal vapor beams. It also houses movable, large-format, high-speed pnCCD X-ray detectors for detecting scattered and fluorescent photons. Multiple charged-particle spectrometer options are compatible with the LAMP chamber, including a double-sided spectrometer for simultaneous and even coincident measurements of electrons, ions, and photons produced by the interaction of the high-intensity X-ray beam with the various samples. Here in this paper we describe the design and capabilities of the spectrometers along with some general aspects of the LAMP chamber and show some results from the initial instrument commissioning.

47 OTHER INSTRUMENTATION↗

Wall-loss distribution of charge breeding ions in an electron cyclotron resonance ion source

The ion loss distribution in an electron cyclotron resonance ion source (ECRIS) was investigated to understand the element dependence of the charge breeding efficiency in an electron cyclotron resonance (ECR) charge breeder. The radioactive {sup 111}In{sup 1+} and {sup 140}Xe{sup 1+} ions (typical nonvolatile and volatile elements, respectively) were injected into the ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex to breed their charge states. Their respective residual activities on the sidewall of the cylindrical plasma chamber of the source were measured after charge breeding as functions of the azimuthal angle and longitudinal position and two-dimensional distributions of ions lost during charge breeding in the ECRIS were obtained. These distributions had different azimuthal symmetries. The origins of these different azimuthal symmetries are qualitatively discussed by analyzing the differences and similarities in the observed wall-loss patterns. The implications for improving the charge breeding efficiencies of nonvolatile elements in ECR charge breeders are described. The similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

43 PARTICLE ACCELERATORS↗