Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

SU-F-T-174: Patient-Specific Point Dose Measurement Using Fiber Optic Radiation Sensor Using Cerenkov Radiation for Proton Therapeutic Beam

Purpose: A fiber-optic radiation sensor using Cerenkov radiation (FOCR) has been widely studied for use as a dosimeter for proton therapeutic beam. We developed the FOCR, and it applied to patient-specific point dose measurement in order to evaluate the effectiveness of the FOCR system for proton therapy QA. Methods: Calibration of FOCR was performed with an ionization chamber whose absolute doses were determined according to the IAEA TRS-398 protocol. To determine the calibration curve, the FOCR was irradiated perpendicularly to the proton beam at the 13 dose levels steps. We selected five actual patient treatment plans performed at proton therapy center and compared the resulting FOCR measurements with the ionization chamber measurements. Results: The Cerenkov light yield of the FOCR increases linearly with as the dose measured using the ionization chamber increases from 0 cGy to 500 cGy. The results indicate that the fitting curve is linear, suggesting that dose measurement based on the light yield of the FOCR is possible. The results of proton radiation dose QA performed using the FOCR for 10 proton fields and five patients are good agreement with an ionization chamber. Conclusion: We carried out the patient QA using the FOCR for proton therapeutic beam and evaluated the effectiveness of the FOCR as a proton therapy QA tool. Our results indicate that the FOCR is suitable for use in patient QA of clinical proton beams.

60 APPLIED LIFE SCIENCES↗

Experiences of Vulnerable Residential Customer Subpopulations with Critical Peak Pricing

DOE decided to co-fund ten utilities to undertake eleven experimentally-designed Consumer Behavior Studies (CBS) that proposed to examine a wide range of the topics of interest to the electric utility industry. Each chosen utility was to design, implement and evaluate their own study in order to address questions of interest both to itself and to its applicable regulatory authority, whose approval was generally necessary for the study to proceed. The DOE Office of Energy Delivery and Electricity Reliability (OE), however, did set guidelines, both in the FOA and subsequently during the contracting period, for what would constitute an acceptable study under the Grant. To assist in ensuring these guidelines were adhered to, OE requested that LBNL act as project manager for these Consumer Behavior Studies to achieve consistency of experimental design and adherence to data collection and reporting protocols across the ten utilities. As part of its role, LBNL formed technical advisory groups (TAG) to separately assist each of the utilities by providing technical assistance in all aspects of the design, implementation and evaluation of their studies. LBNL was also given a unique opportunity to perform a comprehensive, cross-study analysis that uses the customer-level interval meter and demographic data made available by these utilities due to SGIG-imposed reporting requirements, in order to analyze critical policy issues associated with AMI-enabled rates and control/information technology. LBNL will publish the results of these analyses in a series of research reports, of which this is one, that attempt to address critical policy issues relating to a variety of topics including customer acceptance, retention and load response to time-based rates and various forms of enabling control and information technologies. This report extends the existing empirical literature on the experiences of low-income customers exposed to critical peak pricing, and provides the first glimpses into the experiences of the elderly and those who reported being chronically ill. Specifically, we analyzed two of the time-based rate consumer behavior studies, which were co-funded by the Department of Energy as part of the Smart Grid Investment Grant program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WE-FG-207B-11: Objective Image Characterization of Spectral CT with a Dual-Layer Detector

Purpose: To obtain objective reference data for the spectral performance on a dual-layer detector CT platform (IQon, Philips) and compare virtual monoenergetic to conventional CT images. Methods: Scanning was performed using the hospital’s clinical adult body protocol: helical acquisition at 120kVp, with CTDIvol=15mGy. Multiple modules (591, 515, 528) of a CATPHAN 600 phantom and a 20 cm diameter cylindrical water phantom were scanned. No modifications to the standard protocol were necessary to enable spectral imaging. Both conventional and virtual monoenergetic images were generated from acquired data. Noise characteristics were assessed through Noise Power Spectra (NPS) and pixel standard deviation from water phantom images. Spatial resolution was evaluated using Modulation Transfer Functions (MTF) of a tungsten wire as well as resolution bars. Low-contrast detectability was studied using contrast-to-noise ratio (CNR) of a low contrast object. Results: MTF curves of monoenergetic and conventional images were almost identical. MTF 50%, 10%, and 5% levels for monoenergetic images agreed with conventional images within 0.05lp/cm. These observations were verified by the resolution bars, which were clearly resolved at 7lp/cm but started blurring at 8lp/cm for this protocol in both conventional and 70 keV images. NPS curves indicated that, compared to conventional images, the noise power distribution of 70 keV monoenergetic images is similar (i.e. noise texture is similar) but exhibit a low frequency peak at keVs higher and lower than 70 keV. Standard deviation measurements show monoenergetic images have lower noise except at 40 keV where it is slightly higher. CNR of monoenergetic images is mostly flat across keV values and is superior to that of conventional images. Conclusion: Values for standard image quality metrics are the same or better for monoenergetic images compared to conventional images. Results indicate virtual monoenergetic images can be used without any loss in image quality or noise penalties relative to conventional images. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.

60 APPLIED LIFE SCIENCES↗

Toward equitable environmental exposure modeling through convergence of data, open, and citizen sciences: an example of air pollution exposure modeling amidst increasing wildfire smoke

Exposure modeling is critical in environmental epidemiology and human health but may face challenges (e.g., skewed data, unequal error, context-insensitive validation, and computational demands). Modeling decisions reflect the intended use of the models and the values that modelers prioritize. We aimed to provide a conceptual framework and machine learning (ML) modeling protocols that address these issues. With 500m-gridded hourly PM 2.5 and O 3 levels in Illinois before, during, and after the 2023 Canadian wildfire season as a motivating example, we conducted modeling experiments to evaluate modeling methods, guided by three domains we propose based on theories of science: 1) Data Diversity, leveraging open and citizen science data to enhance inclusivity, parsimony, and representativeness; 2) Equitable Accuracy, ensuring fairly distributed uncertainties across subpopulations; and 3) Sustainable Modeling, balancing accuracy with reducing computational demands to promote accessibility for under-resourced researchers. Here, we found that ML with publicly available data can achieve high accuracy. Depending on methods, performance may vary substantially, even with identical input data. Large but skewed data may reduce performance. Misuse of cross-validation protocols can underestimate prediction error; although we observed R 2 s of ∼98 %, the modeled estimates varied significantly, indicating the need for careful model validation. By using new modeling protocols including representativeness-considered training and validation data and a new loss function, we achieved high agreement between estimates and ground-based measurements (e.g., R 2 = ∼90 % for PM 2.5 ; ∼80 % for O 3 ), equally distributed errors across sociodemographic strata and urban–rural divides, and reduction in computation time—from several weeks or months to a few days.

Exposure assessment↗

Using Accelerated Testing To Predict Module Reliability: Preprint

Long-term reliability is critical to the cost effectiveness and commercial success of photovoltaic (PV) products. Today most PV modules are warranted for 25 years, but there is no accepted test protocol to validate a 25-year lifetime. The qualification tests do an excellent job of identifying design, materials, and process flaws that are likely to lead to premature failure (infant mortality), butthey are not designed to test for wear-out mechanisms that limit lifetime. This paper presents a method for evaluating the ability of a new PV module technology to survive long-term exposure to specific stresses. The authors propose the use of baseline technologies with proven long-term field performance as controls in the accelerated stress tests. The performance of new-technology modules canthen be evaluated versus that of proven-technology modules. If the new-technology demonstrates equivalent or superior performance to the proven one, there is a high likelihood that they will survive versus the tested stress in the real world.

14 SOLAR ENERGY↗

Quantized resistance revealed at the criticality of the quantum anomalous Hall phase transitions

In multilayered magnetic topological insulator structures, magnetization reversal processes can drive topological phase transitions between quantum anomalous Hall, axion insulator, and normal insulator states. Here we report an examination of the critical behavior of two such transitions: the quantum anomalous Hall to normal insulator (QAH-NI), and quantum anomalous Hall to axion insulator (QAH-AXI) transitions. By introducing a new analysis protocol wherein temperature dependent variations in the magnetic coercivity are accounted for, the critical behavior of the QAH-NI and QAH-AXI transitions are evaluated over a wide range of temperature and magnetic field. Despite the uniqueness of these different transitions, quantized longitudinal resistance and Hall conductance are observed at criticality in both cases. Furthermore, critical exponents were extracted for QAH-AXI transitions occurring at magnetization reversals of two different magnetic layers. The observation of consistent critical exponents and resistances in each case, independent of the magnetic layer details, demonstrates critical behaviors in quantum anomalous Hall transitions to be of electronic rather than magnetic origin. Our finding offers a new avenue for studies of phase transition and criticality in QAH insulators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine-learned interatomic potentials by active learning: amorphous and liquid hafnium dioxide

We propose an active learning scheme for automatically sampling a minimum number of uncorrelated configurations for fitting the Gaussian Approximation Potential (GAP). Our active learning scheme consists of an unsupervised machine learning (ML) scheme coupled with a Bayesian optimization technique that evaluates the GAP model. We apply this scheme to a Hafnium dioxide (HfO 2 ) dataset generated from a "melt-quench" ab initio molecular dynamics (AIMD) protocol. Our results show that the active learning scheme, with no prior knowledge of the dataset, is able to extract a configuration that reaches the required energy fit tolerance. Further, molecular dynamics (MD) simulations performed using this active learned GAP model on 6144 atom systems of amorphous and liquid state elucidate the structural properties of HfO 2 with near ab initio precision and quench rates (i.e., 1.0 K/ps) not accessible via AIMD. The melt and amorphous X-ray structural factors generated from our simulation are in good agreement with experiment. In addition, the calculated diffusion constants are in good agreement with previous ab initio studies.

36 MATERIALS SCIENCE↗

A checkpoint compression study for high-performance computing systems

As high-performance computing systems continue to increase in size and complexity, higher failure rates and increased overheads for checkpoint/restart (CR) protocols have raised concerns about the practical viability of CR protocols for future systems. Previously, compression has proven to be a viable approach for reducing checkpoint data volumes and, thereby, reducing CR protocol overhead leading to improved application performance. In this article, we further explore compression-based CR optimization by exploring its baseline performance and scaling properties, evaluating whether improved compression algorithms might lead to even better application performance and comparing checkpoint compression against and alongside other software- and hardware-based optimizations. Our results highlights are: (1) compression is a very viable CR optimization; (2) generic, text-based compression algorithms appear to perform near optimally for checkpoint data compression and faster compression algorithms will not lead to better application performance; (3) compression-based optimizations fare well against and alongside other software-based optimizations; and (4) while hardware-based optimizations outperform software-based ones, they are not as cost effective.

97 MATHEMATICS AND COMPUTING↗

Temperature-At-Depth Maps For the Conterminous US and Geothermal Resource Estimates

A third generation geothermal resource assessment has recently been completed for the conterminous US based on a revised heat flow map using over 35,000 data sites. Improvements include: nearly doubling the number of data points used in the analysis, more detailed thermal conductivity models for temperature-at-depth and heat flow calculations, and addition of a significant number of calibration wells as checks on the bottom hole temperature (BHT) correction. The results increase the accuracy of temperature-at-depth models for the conterminous US. These temperature models are the key input required for evaluating the non-conventional geothermal resources on a regional to sub-regional basis. The new resource assessment was prepared according to a proposed global protocol for estimating Enhanced/ Engineered Geothermal Systems (EGS) resource potential. A comparison of the new assessment approach with previous studies is provided, along with a discussion of the differences associated with the revised approach.

15 GEOTHERMAL ENERGY↗

Open-Source Framework for Data Storage and Visualization of Real-Time Experiments

Digital real time simulators (DRTS) are increasingly being used for the evaluation of power hardware and controller hardware in the laboratory prior to field deployment. Although DRTS are capable of simulating large models in real-time, it is challenging to visualize the results of large models without overdrawing or confounding the viewer. This paper provides an open-source framework for users to visualize their DRTS-based hardware-in-the-loop (HIL) experimental results in real-time. This proposed framework can be used by experimental test beds that can push data through an internet protocol based network. The proposed framework includes three main components. First, it includes the DRTS that generates and pushes the data to a relay. Second, it includes an application that serves multiple purposes, from data storage, testing, and translation of the data to a publisher/subscriber protocol. Finally, it includes libraries and applications that can be used to visualize the data by subscribing to the relay. This framework is available in open source, and it is tested using the HIL platform developed for testing advanced distribution management systems.

advanced distribution management systems↗

SU-E-T-634: Analysis of Volume Based GYN HDR Brachytherapy Plans for Dose Calculation to Organs At Risk(OAR)

Purpose: We have analyzed the dose volume histogram of 140 CT based HDR brachytherapy plans and evaluated the dose received to OAR ; rectum, bladder and sigmoid colon based on recommendations from ICRU and Image guided brachytherapy working group for cervical cancer . Methods: Our treatment protocol consist of XRT to whole pelvis with 45 Gy at 1.8Gy/fraction followed by 30 Gy at 6 Gy per fraction by HDR brachytherapy in 2 weeks . The CT compatible tandem and ovoid applicators were used and stabilized with radio opaque packing material. The patient was stabilized using special re-locatable implant table and stirrups for reproducibility of the geometry during treatment. The CT scan images were taken at 3mm slice thickness and exported to the treatment planning computer. The OAR structures, bladder, rectum and sigmoid colon were outlined on the images along with the applicators. The prescription dose was targeted to A left and A right as defined in Manchester system and optimized on geometry . The dosimetry was compared on all plans using the parameter Ci.sec.cGy-1 . Using the Dose Volume Histogram (DVH) obtained from the plans the doses to rectum, sigmoid colon and bladder for ICRU defined points and 2cc volume were analyzed and reported. The following criteria were used for limiting the tolerance dose by volume (D2cc) were calculated. The rectum and sigmoid colon doses were limited to <75Gy. The bladder dose was limited to < 90Gy from both XRT and HDR brachytherapy. Results: The average total (XRT+HDRBT) BED values to prescription volume was 120 Gy. Dose 2cc to rectum was 70Gy +/− 17Gy, dose to 2cc bladder was 82+/−32 Gy. The average Ci.sec.cGy-1 calculated for the HDR plans was 6.99 +/− 0.5 Conclusion: The image based treatment planning enabled to evaluati volume based dose to critical structures for clinical interpretation.

60 APPLIED LIFE SCIENCES↗

Characterization of GafChromic XR-RV2 film and comparator strip using a flatbed scanner in reflection mode

Interventional cardiology procedures are an effective alternative for the reestablishment of correct sanguineous circulation in the heart. However, this kind of procedures exposes to the patients to a relatively high radiation doses. Usually, the surface peak skin dose is evaluated using a visual scale with a comparator strip, nevertheless, even if the comparator strip provides a simple and quick method for estimating the dose it has an uncertainty of {+-}25%. For this reason, a better evaluation method is needed. The objective of our project is to determine the surface peak skin dose of interventional cardiology procedures using GafChromic XR-RV2 film together with a commercial flatbed scanner in reflection mode. Here we report a protocol to handle GafChromic XR-RV2 film using a commercial flat bed scanner in reflection mode aiming at an uncertainty of {+-}3%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric impact of translational and rotational setup errors for spine stereotactic body radiotherapy: A phantom study

This study aimed to investigate experimentally the effect of translational and rotational setup errors on 3-dimensional dose distributions by using the gamma index and dose volumetric indices for spine stereotactic body radiotherapy. Treatment plans were designed in accordance with the Radiation Therapy Oncology Group (RTOG) 0631 protocol. Measurements were taken using a Delta4 phantom (ScandiDos, Uppsala, Sweden). Setup errors were generated using the HexaMotion 6D moving platform (ScandiDos). Dose distributions in the presence of setup errors were evaluated, according to the γ passing rate with the 3% and 2 mm criteria (γ{sub 3%/2 mm}) and dose volumetric indices (D{sub 90} for the target volume and D{sub 2} for the spinal cord), using the Delta4 device (ScandiDos). The sensitivity coefficient, which represented the correlation between the γ{sub 3%/2 mm} passing rate and dose volumetric indices, was determined to assess robustness against setup errors. Rotational setup errors of 2° were equivalent to translational setup errors of 2 mm for the γ{sub 3%/2 mm} passing rate, D{sub 90} for the target, and D{sub 2} for the spinal cord. D{sub 90} for the target had low robustness against a translational setup error in the vertical direction and a rotational setup error in the pitch direction. D{sub 2} for the spinal cord was sensitive to a translational setup error in the lateral direction and a rotational setup error in the roll direction. The positioning accuracy of the rotational setup error, corresponding to the tolerance level of image-guided radiotherapy in the RTOG 0631 protocol, was required to be ≤ 2°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-site evaluation of stratified and balanced sampling of soil organic carbon stocks in agricultural fields

Estimating soil organic carbon (SOC) stocks in agricultural fields is essential for environmental and agronomic research, management, and policy. Stratified sampling is a classic strategy for estimating mean soil properties, and has recently been codified in SOC monitoring protocols. However, for the specific task of estimating the SOC stock of an agricultural field, concrete guidance is needed for which covariates to stratify on and how much stratification can improve estimation efficiency. It is also unknown how stratified sampling of SOC stocks compares to modern alternatives, notably doubly balanced sampling. To address these gaps, we collected high-density (average of 7 samples ha -1 ) and deep (average of 75 cm) measurements of SOC stocks at eight commercial fields under maize-soybean production in two US Midwestern states. We combined these measurements with a Bayesian geostatistical model to evaluate stratified and balanced sampling strategies that use a set of readily-available geographic, topographic, spectroscopic, and soil survey data. We examined the number of samples needed to achieve a given level of SOC stock estimation accuracy. While stratified sampling using these variables enables an average sample size reduction of 17% (95% CI, 11% to 23%) compared to simple random sampling, doubly balanced sampling is consistently more efficient, reducing sample sizes by 32% (95% CI, 25% to 37%). The data most important to these efficiency gains are a remotely-sensed SOC index, SSURGO estimates of SOC stocks, and the topographic wetness index. We conclude that in order to meet the urgent challenge of climate change, SOC stocks in agricultural fields could be more efficiently estimated by taking advantage of this readily-available data, especially with doubly balanced sampling.

54 ENVIRONMENTAL SCIENCES↗

Closed-loop optimization of fast-charging protocols for batteries with machine learning

Simultaneously optimizing many design parameters in time-consuming experiments causes bottlenecks in a broad range of scientific and engineering disciplines. One such example is process and control optimization for lithium-ion batteries during materials selection, cell manufacturing and operation. A typical objective is to maximize battery lifetime; however, conducting even a single experiment to evaluate lifetime can take months to years. Furthermore, both large parameter spaces and high sampling variability necessitate a large number of experiments. As such, the key challenge is to reduce both the number and the duration of the experiments required. Here we develop and demonstrate a machine learning methodology to efficiently optimize a parameter space specifying the current and voltage profiles of six-step, ten-minute fast-charging protocols for maximizing battery cycle life, which can alleviate range anxiety for electric-vehicle users. We combine two key elements to reduce the optimization cost: an early-prediction model, which reduces the time per experiment by predicting the final cycle life using data from the first few cycles, and a Bayesian optimization algorithm, which reduces the number of experiments by balancing exploration and exploitation to efficiently probe the parameter space of charging protocols. Using this methodology, we rapidly identify high-cycle-life charging protocols among 224 candidates in 16 days (compared with over 500 days using exhaustive search without early prediction), and subsequently validate the accuracy and efficiency of our optimization approach. Our closed-loop methodology automatically incorporates feedback from past experiments to inform future decisions and can be generalized to other applications in battery design and, more broadly, other scientific domains that involve time-intensive experiments and multi-dimensional design spaces.

25 ENERGY STORAGE↗

The role of contrast-enhanced computed tomography to detect renal stones

Purpose: To investigate the detectability of renal stones in corticomedullary and nephrographic phases on contrast-enhanced computed tomography (CT). Methods: All consecutive patients between January 2012 and February 2016 undergoing CT of the kidneys according to our department’s standard four-phase protocol and having at least one stone in the NC-phase (NCP) were included. Fifty patients with altogether 136 stones were eligible. Two radiologists in consensus evaluated the NCP from each examination and documented the number, location, and size of stones. Three abdominal radiologists blinded to the findings of the NCP reviewed independently the corticomedullary and nephrographic phases on two different occasions. They reported the number and location of stones in each kidney. For the inter-observer agreement the intra-class correlation coefficient (ICC) was estimated. The detection rate of renal stones was calculated for the three radiologists and compared between the two contrast-enhanced phases and the results were analyzed with concern to the size of the stones. Results: The ICC was 0.86. There was no statistically significant difference between corticomedullary and nephrographic phases (p = 0.94). The detection rate for stones measuring 3–5 mm was 82–88% and 98% for stones ≥ 6 mm. Conclusion: The detectability of renal stones ≥ 6 mm on contrast-enhanced CT is extremely high. This means that stones with a higher risk of not passing spontaneously can be safely diagnosed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Importance of Local Control in Early-Stage Prostate Cancer: Outcomes of Patients With Positive Post-Radiation Therapy Biopsy Results Treated in RTOG 9408

Purpose: The purpose of this study was to assess the association between positive post-radiation therapy (RT) biopsy results and subsequent clinical outcomes in males with localized prostate cancer. Methods and Materials: Radiation Therapy Oncology Group study 94-08 analyzed 1979 males with prostate cancer, stage T1b-T2b and prostate-specific antigen concentrations of ≤20 ng/dL, to investigate whether 4 months of total androgen suppression (TAS) added to RT improved survival compared to RT alone. Patients randomized to receive TAS received flutamide with luteinizing hormone releasing hormone (LHRH) agonist. According to protocol, patients without evidence of clinical recurrence or initiation of additional endocrine therapy underwent repeat prostate biopsy 2 years after RT completion. Statistical analysis was performed to evaluate the impact of positive post-RT biopsy results on clinical outcomes. Results: A total of 831 patients underwent post-RT biopsy, 398 were treated with RT alone and 433 with RT plus TAS. Patients with positive post-RT biopsy results had higher rates of biochemical failure (hazard ratio [HR] = 1.7; 95% confidence interval [CI] = 1.3-2.1) and distant metastasis (HR = 2.4; 95% CI = 1.3-4.4) and inferior disease-specific survival (HR = 3.8; 95% CI = 1.9-7.5). Positive biopsy results remained predictive of such outcomes after correction for potential confounders such as Gleason score, tumor stage, and TAS administration. Prior TAS therapy did not prevent elevated risk of adverse outcome in the setting of post-RT positive biopsy results. Patients with Gleason score ≥7 with a positive biopsy result additionally had inferior overall survival compared to those with a negative biopsy result (HR = 1.56; 95% CI = 1.04-2.35). Conclusions: Positive post-RT biopsy is associated with increased rates of distant metastases and inferior disease-specific survival in patients treated with definitive RT and was associated with inferior overall survival in patients with high-grade tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Designing Scalable PGAS Communication Subsystems on Cray Gemini Interconnect

The Cray Gemini Interconnect has been recently introduced as a next generation network architecture for building multi-petaflop supercomputers. Cray XE6 systems including LANL Cielo, NERSC Hopper, ORNL Titan and proposed NCSA BlueWaters leverage the Gemini Interconnect as their primary Interconnection network. At the same time, programming models such as the Message Passing Interface (MPI) and Partitioned Global Address Space (PGAS) models such as Unified Parallel C (UPC) and Co-Array Fortran (CAF) have become available on these systems. Global Arrays is a popular PGAS model used in a variety of application domains including hydrodynamics, chemistry and visualization. Global Arrays uses Aggregate Re- mote Memory Copy Interface (ARMCI) as the communication runtime system for Remote Memory Access communication. This paper presents a design, implementation and performance evaluation of scalable and high performance communication subsystems on Cray Gemini Interconnect using ARMCI. The design space is explored and time-space complexities of commu- nication protocols for one-sided communication primitives such as contiguous and uniformly non-contiguous datatypes, atomic memory operations (AMOs) and memory synchronization is presented. An implementation of the proposed design (referred as ARMCI-Gemini) demonstrates the efficacy on communication primitives, application kernels such as LU decomposition and full applications such as Smooth Particle Hydrodynamics (SPH) application.

ARMCI↗