Search NASA⌕ Search

SEARCH · Search NASA

Results for “generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Gas Generation Testing of Crystalline Silicotitanate Ion Exchange Media

The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar media under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): (1) CST in water at 25°C tested to 300 Mrad total dose, (2) wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (3) dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (4) CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose, and (5) CST in 5.6M Na simulant with 1%(w/w) total organic carbon as Na3-HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per component basis), gas generation rates normalized to the CST bed volume tested, and G-values for each gas species. The reported results illustrate that the CST in water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air-coupled tsunamis generated from impacts and airbursts: Our understanding before Hunga-Tonga Hunga-Ha'apai

The effort to prevent or mitigate the effects of an impact on Earth is known as planetary defense. A significant component of planetary defense research involves risk assessment. Much of our understanding of the risk from near-Earth objects comes from the geologic record in the form of impact craters, but not all asteroid impacts are crater-forming events. Small asteroids explode before reaching the surface, generating an airburst, and most impacts into the ocean do not penetrate the water to form a crater in the sea floor. The risk from these non-crater-forming ocean impacts and airbursts is difficult to quantify and represents a significant uncertainty in our assessment of the overall threat. We are currently working to better understand impact scenarios that can generate dangerous tsunamis. One of the suggested mechanisms for the production of asteroid–generated tsunamis is by direct coupling of the pressure wave to the water, analogous to the means by which a moving weather front can generate a meteotsunami. To test this hypothesis, we ran a series of airburst simulations and provided time-resolved pressure and wind profiles to use as source functions for tsunami models. We used the CTH hydrocode to model the various airburst scenarios to compare to the results of other simulations and provide time dependent boundary conditions as input to shallow-water wave propagation codes. The strongest and most destructive meteotsunamis are generated by atmospheric pressure oscillations with amplitudes of only a few hPa1 (mbar), corresponding to changes in sea level of a few cm. The resulting wave is strongest when there is a resonance between the ocean and the atmospheric forcing. A Proudman resonance takes place when the atmospheric disturbance’s translational speed (U) equals the longwave phase speed $\sqrt{gh}$ of shallow water wave. Coupling is strongest when the Froude number (Fr=U/c) is unity. A weather front propagates much slower than the speed of sound, so meteotsunamis are most common and dangerous in shallow bodies of water such as the Mediterranean Sea or Lake Michigan. By contrast, the blast wave from an airburst or crater-forming impact propagates at a speed faster than a tsunami in the deepest ocean, and a Proudman resonance cannot be achieved even though the overpressures are orders of magnitude greater. However, blast wave profiles are N-waves in which a sharp shock wave leading to overpressure is followed by a more gradual rarefaction to a much longer-duration underpressure phase. Even though the blast outruns the water wave it is forcing, the tsunami should continue to be driven by the out-of-resonance gradient associated with the suction phase, which may depend strongly on the details of the airburst or impact scenario. The open question is whether there are any conditions under which such an airburst-driven tsunami can be dangerous enough to contribute to the overall impact risk. We have also identified other potential mechanisms for airburst-generated tsunamis: 1) reaction force at the surface from the plume ejected into space, which carries significant momentum, 2) expanding toroidal vortices at the surface, which travel more slowly than the shock wave and can generate a Proudman resonance in relatively shallow ocean (such as continental shelf), and 3) steam explosion from seawater ablation by a “Type II” (Libyan Desert Glass-type) airburst in which the hot vapor jet descends to the surface. On January 15, 2022, the Hunga-Tonga Hunga-Ha’apai volcano, located approximately 60 km north of Tongatapu, the main island of Tonga, violently erupted with a powerful explosion, culminating the period of volcanic activity that started in December of 2021. This event and resulting tsunamis provided an existence proof for the air pressure wave coupling mechanism we proposed. It also suggests that it can be stronger and more significant over much greater distances than we contemplated, leading to global tsunamis associated with impact events on land as well as in the water. Large atmospheric explosions generate global Lamb waves with larger amplitudes, longer periods, and slower speeds than the local and regional blast waves we modeled prior to that event. This paper reviews our analysis and modeling of airburst-driven tsunamis prior to the 2022 Hunga-Tonga Hunga-Ha’apai tsunami, which was the subject of two presentations at the 2023 Planetary Defense Conference and is the subject of another paper currently in preparation.

54 ENVIRONMENTAL SCIENCES↗

Improved Cross Section Generation Capability of Griffin in FY22

The Griffin code is a Multiphysics Object-Oriented Simulation Environment (MOOSE) based reactor multiphysics analysis application jointly developed by Idaho National Laboratory and Argonne National Laboratory. The code includes a variety of deterministic steady-state transport solvers for fixed source, k-eigenvalue, adjoint, and subcritical multiplication as well as transient solvers for spatial dynamics with the improved quasi-static method. Griffin uses cross section data in the ISOXML format generated from external deterministic or Monte Carlo cross section generation codes. In recent years, the MC 2 -3 modules have been added to Griffin for fast reactor cross section generation, and the self-shielding application programming interface (SSAPI) was implemented in the ISOXML module for thermal reactor cross section generation. The on-the-fly slowing down method and double-heterogeneity treatment have been implemented to SSAPI and verified against particulate fuel-bearing graphite-moderated thermal reactor problems with high accuracy. This year, work has been focused on improving the cross section generation capability of ISOXML and streamlining the cross section generation procedures. In addition, the form function data were added to ISOXML in order to support the pin power reconstruction capability that was newly implemented in Griffin in this fiscal year. To facilitate the cross section generation using MC 2 -3 and SSAPI in Griffin, the cross section generation workflows have been set up for both fast and thermal spectrum reactors. The MOOSE action system tool was devised for fast spectrum problems, and the MOOSE stochastic tool was adopted to the branch calculation procedure for thermal spectrum problems. Meanwhile, to ensure the accuracy of group-constants, the thermal up-scattering kernel calculator accounting for resonance scattering was implemented in ISOXML, demonstrating the accurate computation of a Doppler-broadened scattering kernel of any Legendre order within a reasonable timescale. Other aspects of ISOXML, such as deletion solver and data, documentation, ISOXML file management, and the interface for Mixture, were improved as well.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ELM 1016706669-AA B581 GDE01 Generator Summary pg 4-5 only

The table below shows the general load breakdown for 581GDE01. Although the total connected load exceeds the generator’s 150kW nameplate capacity, the normal configured load during standby power mode is less, which was measured at 81kW, or 54%, during preventive maintenance activities on 12/12/24. The generator’s available spare capacity must account for dynamically changing loads that can increase the total power demand at any time. If the two online VFD’s are operated at full speed the actual standby mode load is estimated to increase by 38kW, which would bring the total configured load during standby power mode to 119kW, or 79%, still within 581GDE01’s acceptable capacity. Per the LLNL Site 200 Generator Consolidation Final Study 2022, “Standby Emergency Generator nameplate ratings are based upon operation with varying load averaging 70% of the nameplate for 200 hours per year. Continuous loading between 70% and 100% will reduce a generator’s expected lifetime before a major overhaul. This is never a problem with Laboratory machines because of conservative application of generators and the reliability of the normal power system combines to keeps the load and hours down”. To achieve optimal performance and prolong generator life, the recommended generator loading is between 40% and 70%, optimally at 70%, which 581GDE01 appropriately falls within.

42 ENGINEERING↗

High-power radio frequency pulse generation and extration based on wakefield excited by an intense charged particle beam in dielectric-loaded waveguides.

Power extraction using a dielectric-loaded (DL) waveguide is a way to generate high-power radio frequency (RF) waves for future particle accelerators, especially for two-beam-acceleration. In a two-beam-acceleration scheme, a low-energy, high-current particle beam is passed through a deceleration section of waveguide (decelerator), where the power from the beam is partially transferred to trailing electromagnetic waves (wakefields); then with a properly designed RF output coupler, the power generated in the decelerator is extracted to an output waveguide, where finally the power can be transmitted and used to accelerate another usually high-energy low-current beam. The decelerator, together with the RF output coupler, is called a power extractor. At Argonne Wakefield Accelerator (AWA), we designed a 7.8GHz power extractor with a circular DL waveguide and tested it with single electron bunches and bunch trains. The output RF frequency (7.8GHz) is the sixth harmonic of the operational frequency (1.3GHz) of the electron gun and the linac at AWA. In single bunch excitation, a 1.7ns RF pulse with 30MW of power was generated by a single 66nC electron bunch passing through the decelerator. In subsequent experiments, by employing different splitting-recombining optics for the photoinjector laser, electron bunch trains were generated and thus longer RF pulses could be successfully generated and extracted. In 16-bunch experiments, 10ns and 22ns RF pulses have been generated and extracted; and in 4-bunch experiments, the maximum power generated was 44MW with 40MW extracted. A 26GHz DL power extractor has also been designed to test this technique in the millimeter-wave range. A power level of 148MW is expected to be generated by a bunch train with a bunch spacing of 769ps and bunch charges of 20nC each. The arrangement for the experiment is illustrated in a diagram. Higher-order-mode (HOM) power extraction has also been explored in a dual-frequency design. By using a bunch train with a bunch spacing of 769ps and bunch charges of 50nC each, 90.4MW and 8.68MW of extracted power levels are expected to be reached at 20.8GHz and 35.1GHz, respectively. In order to improve efficiency in HOM power extraction, a novel technique has been proposed to suppress unintended modes.

43 PARTICLE ACCELERATORS↗

Mitigation of Hydrogen Gas Generation from the Reaction of Water with Uranium Metal in K Basins Sludge

Means to decrease the rate of hydrogen gas generation from the chemical reaction of uranium metal with water were identified by surveying the technical literature. The underlying chemistry and potential side reactions were explored by conducting 61 principal experiments. Several methods achieved significant hydrogen gas generation rate mitigation. Gas-generating side reactions from interactions of organics or sludge constituents with mitigating agents were observed. Further testing is recommended to develop deeper knowledge of the underlying chemistry and to advance the technology aturation level. Uranium metal reacts with water in K Basin sludge to form uranium hydride (UH3), uranium dioxide or uraninite (UO2), and diatomic hydrogen (H2). Mechanistic studies show that hydrogen radicals (H·) and UH3 serve as intermediates in the reaction of uranium metal with water to produce H2 and UO2. Because H2 is flammable, its release into the gas phase above K Basin sludge during sludge storage, processing, immobilization, shipment, and disposal is a concern to the safety of those operations. Findings from the technical literature and from experimental investigations with simple chemical systems (including uranium metal in water), in the presence of individual sludge simulant components, with complete sludge simulants, and with actual K Basin sludge are presented in this report. Based on the literature review and intermediate lab test results, sodium nitrate, sodium nitrite, Nochar Acid Bond N960, disodium hydrogen phosphate, and hexavalent uranium [U(VI)] were tested for their effects in decreasing the rate of hydrogen generation from the reaction of uranium metal with water. Nitrate and nitrite each were effective, decreasing hydrogen generation rates in actual sludge by factors of about 100 to 1000 when used at 0.5 molar (M) concentrations. Higher attenuation factors were achieved in tests with aqueous solutions alone. Nochar N960, a water sorbent, decreased hydrogen generation by no more than a factor of three while disodium phosphate increased the corrosion and hydrogen generation rates slightly. U(VI) showed some promise in attenuating hydrogen but only initial testing was completed. Uranium metal corrosion rates also were measured. Under many conditions showing high hydrogen gas attenuation, uranium metal continued to corrode at rates approaching those observed without additives. This combination of high hydrogen attenuation with relatively unabated uranium metal corrosion is significant as it provides a means to eliminate uranium metal by its corrosion in water without the accompanying hazards otherwise presented by hydrogen generation.

08 HYDROGEN↗

PhotoVoltaic distributed generation for Lanai power grid real-time simulation and control integration scenario.

This paper discusses the modeling, analysis, and testing in a real-time simulation environment of the Lanai power grid system for the integration and control of PhotoVoltaic (PV) distributed generation. The Lanai Island in Hawaii is part of the Hawaii Clean Energy Initiative (HCEI) to transition to 30% renewable green energy penetration by 2030. In Lanai the primary loads come from two Castle and Cook Resorts, in addition to residential needs. The total peak load profile is 12470 V, 5.5 MW. Currently there are several diesel generators that meet these loading requirements. As part of the HCEI, Lanai has initially installed 1.2 MW of PV generation. The goal of this study has been to evaluate the impact of the PV with respect to the conventional carbon-based diesel generation in real time simulation. For intermittent PV distributed generation, the overall stability and transient responses are investigated. A simple Lanai 'like' model has been developed in the Matlab/Simulink environment (see Fig. 1) and to accommodate real-time simulation of the hybrid power grid system the Opal-RT Technologies RT-Lab environment is used. The diesel generators have been modelled using the SimPowerSystems toolbox swing equations and a custom Simulink module has been developed for the High level PV generation. All of the loads have been characterized primarily as distribution lines with series resistive load banks with one VAR load bank. Three-phase faults are implemented for each bus. Both conventional and advanced control architectures will be used to evaluate the integration of the PV onto the current power grid system. The baseline numerical results include the stable performance of the power grid during varying cloud cover (PV generation ramping up/down) scenarios. The importance of assessing the real-time scenario is included.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Climate Change Impacts to Hydropower Generation in Pacific Northwest River Basins (Final Report)

This is the final technical report describing the research findings for the project, “Climate change impacts to hydropower generation in Pacific Northwest river basins”. The overall objective of the research was to develop a new approach to assess which types of climate changes would adversely affect hydropower production. This research had three major components. First, we conducted a geospatial analysis of the region to identify potential focus basins. We compiled geospatial data on hydropower dam locations, contributing areas to hydropower dams, and climate characteristics in contributing areas. For the potential focus basins identified, we classified these basins by hydrologic regime as snow-dominated, rain-dominated, or mixed. Rain-dominated basins were primarily found in Oregon, with some in western Washington. Most of the basins draining west out of the Cascades in Washington were mixed, whereas most of the potential focus basins in Idaho were snowmelt-dominated. Next, we developed a stochastic conceptual modeling approach in which we stochastically generate a wide range of climate scenarios and use these scenarios to generate time series of reservoir inflows. We developed and applied this modeling approach to the North Fork of the Clearwater River in Idaho. Results showed that increases in temperature in the basin led to decreases in streamflow, even in cases where precipitation increased. Finally, we used the reservoir inflow scenarios from the stochastic conceptual model to force a reservoir operations model for Dworshak reservoir. The wide range of climate scenarios generated by the hydrologic model allowed us to test the sensitivity of reservoir operations objectives to shifts in both temperature and precipitation. Results showed that scenarios with lower inflow had less hydropower generation, but changes in hydropower generation were not always proportional to changes in inflow. Current reservoir operations were better suited to maximize hydropower generation under climate change scenarios with no shift in inflow timing but did not optimize power generation under warming scenarios with earlier snowmelt runoff.

13 HYDRO ENERGY↗

Quantum random number generator

A quantum random number generator (QRNG) and a photon generator for a QRNG are provided. The photon generator may be operated in a spontaneous mode below a lasing threshold to emit photons. Photons emitted from the photon generator may have at least one random characteristic, which may be monitored by the QRNG to generate a random number. In one embodiment, the photon generator may include a photon emitter and an amplifier coupled to the photon emitter. The amplifier may enable the photon generator to be used in the QRNG without introducing significant bias in the random number and may enable multiplexing of multiple random numbers. The amplifier may also desensitize the photon generator to fluctuations in power supplied thereto while operating in the spontaneous mode. In one embodiment, the photon emitter and amplifier may be a tapered diode amplifier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pneumatic System for the Neutron Generator Facility at SRNL

A neutron generator system equipped with a pneumatic sample transfer system, enables scientists to perform neutron activation analysis with increased efficiency and accuracy. The samples are placed in sealed containers called 'rabbits' and are passed through the system. Once sealed in the rabbit, the samples are loaded into the tubes via a hopper mechanism. The sample is launched into the generator with compressed air and captures neutrons, causing the sample to become radioactive. Next, the sample is sent to a detector, where the samples are counted for a set length of time on a Ge detector. Once the detection is completed, the sample is then sent to the trash. The system utilizes an interface to select which generator valve and detector location to send the sample too. This project is supports the future development of the neutron generator in the F wing of 773-A. A program is used to automate the passing of the rabbit through the system. The user is able to select the generator valve and detector to be utilized in the testing of the sample. Using the 'Add Rabbit' button the user can add as many sample rabbits to rabbit editor tab. Characteristics are then entered into the fields for each rabbit. The Pre-Det Cooldown and Post-Det Cooldown are intervals used to space out the time before the rabbit is sent into and out of the detector. After all characteristics are entered, the 'Submit to Hopper' button is selected thus preparing the program to run the rabbits in the inserted order. Small setup of the system using the available parts. Simulates the movement of the rabbit from the generator to the detector. Small valves are located before each manifold. To transport the rabbit from one side to the other, the valve of the sending side must be open and the receiving side must be closed. The manifold and valve in direct line with the compressor would extend to the hopper. Once the hopper is loaded, the valve would be open to send the rabbit to generator. Additional manifolds and other mechanical parts are necessary to complete the system design. To complete the construction of the system additional parts, such as the mechanical parts for the switching mechanism and the solenoid valves, are necessary. Further, to complete the automatization of the system, an Arduino is required to communicate with the valves and adjust the linear servos appropriately so that the rabbits are sent to the selected generator location and detector. This work is aimed to be completed in the next fiscal year.

42 ENGINEERING↗

Renewable Generation, Integration of

The integration of renewable generation consists of all of the changes in power system operations that are required in order to allow renewable generation sources to play a significant role in the electricity system. The impacts are mostly due to variable generation (VG), like wind and solar power. Historically these technologies have been labeled as intermittent generation, but recent trendsprefer the label variable generation. Variable generators have a maximum available generation limit that changes with time (variability) and this limit is not known with perfect accuracy (uncertainty). This uncertainty and variability is in addition to that of the existing system and can therefore create additional challenges for grid operators to maintain their current levels of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of passive vortex generators to enhance vertical mixing in an open raceway pond

A novel use of vortex generators in a raceway pond is described here, with the flow field quantitatively simulated using computational fluid dynamics using the large eddy simulation turbulence model. Persistence lengths of the swirling motion generated by the vortex generators indicate that significant vertical mixing can be achieved by placing vortex generators in the straight section opposite the paddle wheel, downstream of the first hairpin bend. Relatively simple vortex generators are capable of creating stronger swirling motions that persist for a longer distance than those created by the paddle wheel. For optimal performance, vortex generators are positioned side by side but in opposite directions, and their diameters should be equal to or slightly less than the desired liquid depth. The optimal length of a 0.18 m diameter vortex generator in a 0.2 m deep pond was determined to be 0.3 m. As a result, it has been demonstrated that a longer persistence length is achieved by inducing a swirling motion with its rotational axis parallel to the primary flow direction.

09 BIOMASS FUELS↗

Data efficiency assessment of generative adversarial networks in energy applications

This study investigates the data requirements of generative artificial intelligence (AI), particularly generative adversarial networks (GANs), for reliable data augmentation in energy applications. Generative AI, though seen as a solution to data limitations, requires substantial data to learn meaningful distributions—a challenge often overlooked. This study addresses the challenge through synthetic data generation for critical heat flux (CHF) and power grid demand, focusing on renewable and nuclear energy. Two variants of GAN employed are conditional GAN (cGAN) and Wasserstein GAN (wGAN). Our findings include the strong dependency of GAN on data size, with performance declining on smaller datasets and varying performance when generalizing to unseen experiments. Mass flux and heated length significantly influence CHF predictions. wGAN is more robust to feature exclusion, making it suitable for constrained synthetic data generation. In energy demand forecasting, wGAN performed well for solar, wind, and load predictions. Longer lookback hours and larger datasets improved predictions, especially for load power. Seasonal variations posed challenges, with wGAN achieving a relatively high error of Root Mean Squared Error (RMSE) of 0.32 for load power prediction, compared to RMSE of 0.07 under same-season conditions. Feature exclusions impacted cGAN the most, while wGAN showed greater robustness. This study concludes that, while generative AI is effective for data augmentation, it requires substantial data and careful training to generate realistic synthetic data and generalize to new experiments in engineering applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Generating moment matching scenarios using optimization techniques

An optimization based method is proposed to generate moment matching scenarios for numerical integration and its use in stochastic programming. The main advantage of the method is its flexibility: it can generate scenarios matching any prescribed set of moments of the underlying distribution rather than matching all moments up to a certain order, and the distribution can be defined over an arbitrary set. This allows for a reduction in the number of scenarios and allows the scenarios to be better tailored to the problem at hand. The method is based on a semi-infinite linear programming formulation of the problem that is shown to be solvable with polynomial iteration complexity. A practical column generation method is implemented. The column generation subproblems are polynomial optimization problems; however, they need not be solved to optimality. It is found that the columns in the column generation approach can be efficiently generated by random sampling. The number of scenarios generated matches a lower bound of Tchakaloff's. The rate of convergence of the approximation error is established for continuous integrands, and an improved bound is given for smooth integrands. Extensive numerical experiments are presented in which variants of the proposed method are compared to Monte Carlo and quasi-Monte Carlo methods on both numerical integration problems and stochastic optimization problems. The benefits of being able to match any prescribed set of moments, rather than all moments up to a certain order, is also demonstrated using optimization problems with 100-dimensional random vectors. Here, empirical results show that the proposed approach outperforms Monte Carlo and quasi-Monte Carlo based approaches on the tested problems.

97 MATHEMATICS AND COMPUTING↗

ARE660 Wind Generator: Low Wind Speed Technology for Small Turbine Development

This project is for the design of a wind turbine that can generate most or all of the net energy required for homes and small businesses in moderately windy areas. The purpose is to expand the current market for residential wind generators by providing cost effective power in a lower wind regime than current technology has made available, as well as reduce noise and improve reliability and safety. Robert W. Preus’ experience designing and/or maintaining residential wind generators of many configurations helped identify the need for an improved experience of safety for the consumer. Current small wind products have unreliable or no method of stopping the wind generator in fault or high wind conditions. Consumers and their neighbors do not want to hear their wind generators. In addition, with current technology, only sites with unusually high wind speeds provide payback times that are acceptable for the on-grid user. Abundant Renewable Energy’s (ARE) basic original concept for the ARE660 was a combination of a stall controlled variable speed small wind generator and automatic fail safe furling for shutdown. The stall control for a small wind generator is not novel, but has not been developed for a variable speed application with a permanent magnet alternator (PMA). The fail safe furling approach for shutdown has not been used to our knowledge.

17 WIND ENERGY↗

Use of the ORNL Tungsten-188/Rhenium-188 Generator for Preparation of the Rhenium-188 HDD/Lipiodol Complex for Transarterial Liver Cancer Therapy

This work describes the installation, use, and quality control (QC) of the alumina-based tungsten-188 ({sup 188}W)/rhenium-188 ({sup 188}Re) generators provided by the Oak Ridge National Laboratory (ORNL). In addition, methods used for concentration of the {sup 188}Re-perrhenate bolus and preparation of {sup 188}Re-labeled HDD (4-hexadecyl-2,2,9,9-tetramethyl-4,7-diaza-1,10-decanethiol) for trans-arterial administration for therapy of nonresectable liver cancer also are described. The {sup 188}W/{sup 188}Re generator has a long useful shelf-life of several months and is a convenient on-site {sup 188}Re production system. {sup 188}Re has excellent therapeutic and imaging properties (T{sub 1/2} 16.9 hours; E{beta}{sub max} 2.12 MeV; 155-keV gamma ray, 15%) and is cost effectively obtained on demand by saline elution of the generator. The clinical efficacy of a variety of {sup 188}Re-labeled agents has been demonstrated for several therapeutic applications. Because of the favorable physical properties of {sup 188}Re, several {sup 188}Re-labeled agents are being developed and evaluated for the treatment of nonresectable/refractory liver cancer. {sup 188}Re-labeled HDD has been the most widely studied of these agents for this application and has been introduced into clinical trials at a number of institutions. The trans-arterial administration of {sup 188}Re-labeled agents for treatment of inoperable liver cancer requires use of high-level (1-2 Ci) {sup 188}W/{sup 188}Re generators. The handling of such high levels of {sup 188}Re imposes radiological precautions normally not encountered in a radiopharmacy and adequate care and ALARA (ie, 'As Low As Reasonably Achievable') principles must be followed. The ORNL generator provides consistently high {sup 188}Re yields (>75%) and low {sup 188}W parent breakthrough (<10{sup -3}%) over an extended shelf-life of several months. However, the high elution volumes (20-40 mL for 1-2 Ci generators) can require concentration of the {sup 188}Re bolus by postelution passage through silver cation chloride trapping columns used in the cost-effective tandem cation/anion column system. The silver column removes the high levels of chloride anion as insoluble AgCl, thus allowing subsequent specific trapping of the perrhenate anion on the small (QMA SeaPak) anion column. This method permits subsequent elution of {sup 188}Re-perrhenate with a small volume of saline, providing a very high activity-concentration solution. Because the {sup 188}Re-specific volume-activity concentration continually decreases with time, the tandem system is especially effective method for extending the useful generator shelf-life. Low elution flow rates (<1 mL/min) minimize any high back pressure which may be encountered during generator/tandem column elution when using tightly packed, small-particle-size commercial columns. In-house preparation of silver cation columns is recommended since the chloride trapping capacity is essentially unlimited, it is inexpensive and not limited in availability to any one supplier, and back pressure can be eliminated by the use of larger particles. Methods for the preparation of {sup 188}Re-HDD have been optimized and this agent can be obtained in high yield (80%).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Intensity, Pulsed, D-D Neutron Generator

Single ion-beam RF-plasma neutron generators are presented as a laboratory source of intense neutrons. The continuous and pulsed operations of such a neutron generator using the deuterium-deuterium fusion reaction are reported. The neutron beam can be pulsed by switching the RF plasma and/or a gate electrode. These generators are actively vacuum pumped so that a continuous supply of deuterium gas is present for the production of ions and neutrons. This contributes to the generator's long life. These single-beam generators are capable of producing up to 1E10 n/s. Previously, Adelphi and LBNL have demonstrated these generators' applications in fast neutron radiography, Prompt Gamma Neutron Activation Analysis (PGNAA) and Neutron Activation Analysis (NAA). Together with an inexpensive compact moderator, these high-output neutron generators extend useful applications to home laboratory operations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protection from ground faults in the stator winding of generators at power plants in the Siberian networks

The experience of many years of experience in developing and utilization of ground fault protection in the stator winding of generators in the Siberian networks is generalized. The main method of protection is to apply a direct current or an alternating current with a frequency of 25 Hz to the primary circuits of the stator. A direct current is applied to turbo generators operating in a unit with a transformer without a resistive coupling to the external grid or to other generators. Applying a 25 Hz control current is appropriate for power generation systems with compensation of a capacitive short circuit current to ground. This method forms the basis for protection of generators operating on busbars, hydroelectric generators with a neutral grounded through an arc-suppression reactor, including in consolidated units with generators operating in parallel on a single low-voltage transformer winding.

42 ENGINEERING↗