Search NASA⌕ Search

SEARCH · Search NASA

Results for “induction generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoparticles in road dust from impervious urban surfaces: distribution, identification, and environmental implications

Nanoparticles (NPs) resulting from urban road dust resuspension are an understudied class of pollutants in urban environments with strong potential for health hazards. The objective of this study was to investigate the heavy metal and nanoparticle content of PM2.5 generated in the laboratory using novel aerosolization of 66 road dust samples collected throughout the mega-city of Shanghai (China). The samples were characterized using an array of techniques including inductively-coupled plasma mass spectrometry, aerosol size distribution measurements, and scanning and transmission electron microscopy coupled with elemental characterization and electron diffraction. Principal metal concentrations were plotted geospatially. Results show that metals were generally enriched in aerosolized samples relative to the bulk dust. Elevated concentrations of metals were found mostly in downtown areas with intense traffic. Fe-, Pb-, Zn-, and Ba-containing NPs were identified using electron microscopy, spectroscopy, and diffraction, and we tentatively identify most of them as either engineered, incidental, or naturally occurring NPs. For example, dangerous Pb sulfide and sulfate NPs likely have an incidental origin and are also sometimes associated with Sn; we believe that these materials originated from an e-waste plant. Size distributions of most aerosolized samples presented a peak in the ultrafine range (<100 nm). We estimate that 3.2 ± 0.7 μg mg -1 of Shanghai road dust may become resuspended in the form of PM2.5. Aerosolization, as done in this study, seems to be a very useful approach to study NPs in dust.

54 ENVIRONMENTAL SCIENCES↗

Stability of High Power Beam Injection in Negative-Ion-Based LHD-NBI

We describe the characteristic of stable beam injection in a neutral beam injector (NBI) for Large Helical Device (LHD) in high injection power of more than 6 MW. In the NBI, it takes a week after starting Cs seeding to finish the pre-injection conditioning. The injection starts with the beam power {approx}6.2 MW, and the maximum power reaches {approx}7 MW. The Cs-seeding rate affects the beam stability in such high power injections. By optimizing the rate to 0.65 mg/shot, the success ratio, which is defined as a ratio of actual pulse duration to setting one, increases to 85-90% in the power and energy range of more than 6.2 MW and 185 keV, respectively. The weights of Cs adsorbed on several surfaces in the ion sources of the NBI are measured by means of Inductively-Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), and averaged surface densities are calculated by dividing with the several surface areas. The seeded Cs of 99.5% is condensed in the plasma generator, and very tiny amount of Cs reaches the surfaces of the accelerator grids. This very low amount of Cs on the grids is interpreted that most of the Cs atom evaporated from the inner walls is ionized during the arc discharges, and repelled to the source plasmas by the electrostatic field for H- extraction.

43 PARTICLE ACCELERATORS↗

Alternative RF coupling configurations for H{sup −} ion sources

RF heated sources for negative hydrogen ions both for fusion and accelerators require very high RF powers in order to achieve the required H{sup −} current what poses high demands on the RF generators and the RF circuit. Therefore it is highly desirable to improve the RF efficiency of the sources. This could be achieved by applying different RF coupling concepts than the currently used inductive coupling via a helical antenna, namely Helicon coupling or coupling via a planar ICP antenna enhanced with ferrites. In order to investigate the feasibility of these concepts, two small laboratory experiments have been set up. The PlanICE experiment, where the enhanced inductive coupling is going to be investigated, is currently under assembly. At the CHARLIE experiment systematic measurements concerning Helicon coupling in hydrogen and deuterium are carried out. The investigations show that a prominent feature of Helicon discharges occurs: the so-called low-field peak. This is a local improvement of the coupling efficiency at a magnetic field strength of a few mT which results in an increased electron density and dissociation degree. The full Helicon mode has not been achieved yet due to the limited available RF power and magnetic field strength but it might be sufficient for the application of the coupling concept to ion sources to operate the discharge in the low-field-peak region.

07 ISOTOPE AND RADIATION SOURCES↗

Design of BLDC Motor Diagnostic Device Based on Surge Test for Phase to Ground Fault

BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.

BLDC motor↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Systematic Investigation of the Effects of Standard-Sample Concentration Mismatch during Fe Isotope Measurement by MC-ICP-MS

Advances in multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) have led to the widespread use of iron (Fe) isotopes to elucidate the (bio)geochemical history of a range of environments. To generate Fe isotope ratio measurements, standard-sample bracketing (SSB) is commonly used to correct for instrumental mass bias inherent to MC-ICP-MS. However, SSB is only accurate when sample and isotope standard Fe concentrations match, in addition to the bulk solution matrix. When the Fe concentrations differ, Fe isotope ratio measurement results may be inaccurate, a phenomenon known as the "self-induced matrix effect." Here, this study systematically characterised the self-induced matrix effect for dry plasma Fe isotope ratio measurements on three MC-ICP-MS instruments and three introduction systems. Our extensive dataset indicates that: (1) the degree of mass bias is consistent regardless of MC-ICP-MS front-end design, (2) the degree of mass bias becomes less reproducible as the concentration difference between the sample and bracketing standard increases, and (3) this applies to both pure Fe solutions and solutions from geological materials. This study reinforces the requirement to match bracketing standard and sample concentrations within 10% and provides a correction method for that fall beyond the recommended concentration range to subsequently allow for proper concentration matching during SSB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of plasma enhanced atomic layer deposition reactor wall conditions on radical and ion substrate fluxes

Chamber wall conditions, such as wall temperature and film deposits, have long been known to influence plasma source performance on thin film processing equipment. Plasma physical characteristics depend on conductive/insulating properties of chamber walls. Radical fluxes depend on plasma characteristics as well as wall recombination rates, which can be wall material and temperature dependent. Variations in substrate delivery of plasma generated species (radicals, ions, etc.) impact the resulting etch or deposition process resulting in process drift. Plasma enhanced atomic layer deposition is known to depend strongly on substrate radical flux, but film properties can be influenced by other plasma generated phenomena, such as ion bombardment. In this paper, the chamber wall conditions on a plasma enhanced atomic layer deposition process are investigated. The downstream oxygen radical and ion fluxes from an inductively coupled plasma source are indirectly monitored in temperature controlled (25–190 °C) stainless steel and quartz reactors over a range of oxygen flow rates. Etch rates of a photoresist coated quartz crystal microbalance are used to study the oxygen radical flux dependence on reactor characteristics. Plasma density estimates from Langmuir probe ion saturation current measurements are used to study the ion flux dependence on reactor characteristics. Reactor temperature was not found to impact radical and ion fluxes substantially. Radical and ion fluxes were higher for quartz walls compared to stainless steel walls over all oxygen flow rates considered. The radical flux to ion flux ratio is likely to be a critical parameter for the deposition of consistent film properties. Reactor wall material, gas flow rate/pressure, and distance from the plasma source all impact the radical to ion flux ratio. These results indicate maintaining chamber wall conditions will be important for delivering consistent results from plasma enhanced atomic layer deposition systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Safety Evaluation of Nitric Acid Reactions with Polysaccharides

The hazards of polysaccharides in a transuranic (TRU) waste drum exposed to nitric acid (HNO 3 ) and metal nitrate salts have been evaluated, based on considerations of how complex nitrogen redox cycles carry out the aqueous phase oxidation of alcohols and related organic functional groups. Of particular emphasis is how these exothermic reactions, coupled with a positive feedback loop inherent to nitrogen redox chemistry, can initiate an autocatalytic thermal runaway and explosive gas generation. This poses the most significant hazard for a TRU waste drum under ambient conditions where acidic solution may be present, either in small quantities as free liquid or sorbed within a solid matrix. Regarding specific mechanistic details, nitric acid is an extremely potent oxidant but is remarkably inert, rarely interacting directly with oxidizable substrates, instead exerting its vast potential energy through lower oxidation state reactants such as nitrogen dioxide (NO 2 ) and nitrous acid (HNO 2 ). These lower oxidation states of nitrogen are generated from the slow self-decomposition of nitric acid, as a result of which oxidation reactions involving nitric acid that have not been preloaded with these reactants commonly experience a quiescent induction period. It is the end of this induction period when exothermic reactivity increases rapidly that the system is most vulnerable to autocatalytic thermal runaway. Metal nitrate salts promote this ambient temperature solution chemistry (cf. traditional oxidizer properties of metal nitrate salts, which operate in the solid state at elevated temperatures) by releasing nitric acid into the system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electromagnetic propulsion alternatives

Mass drivers can serve to propel massive objects by expelling any available material as reaction mass, however, mass driver engines have several limitations such as relatively large payload size and dynamic stability problems. A number of alternative acceleration mechanisms exist which offer advantages for certain applications, such as higher acceleration at a sacrifice in efficiency, smaller possible size and decreased complexity at a sacrifice in service life, etc. The alternative concepts include several variants of the railgun, a family of superconducting slingshot oscillators, a momentum transformer, an impulse induction motor, and a family of hybrid synchronous accelerators. A potential application of considerable interest is the earth-based launching of space cargo or nuclear waste by using off-peak generating capacity to accelerate one ton cargo cylinders at intervals of several minutes.

Kolm, H.↗

A comparative integrated transcript analysis and functional characterization of differential mechanisms for induction of liver hypertrophy in the rat

The main goal of the present work was to better understand the molecular mechanisms underlying liver hypertrophy (LH), a recurrent finding observed following acute or repeated drug administration to animals, using transcriptomic technologies together with the results from conventional toxicology methods. Administration of 5 terminated proprietary drug candidates from participating companies involved in the EU Innomed PredTox Project or the reference hepatotoxicant troglitazone to rats for up to a 14-day duration induced LH as the main liver phenotypic toxicity outcome. The integrated analysis of transcriptomic liver expression data across studies turned out to be the most informative approach for the generation of mechanistic models of LH. In response to a xenobiotic stimulus, a marked increase in the expression of xenobiotic metabolizing enzymes (XME) was observed in a subset of 4 studies. Accumulation of these newly-synthesized proteins within the smooth endoplasmic reticulum (SER) would suggest proliferation of this organelle, which most likely is the main molecular process underlying the LH observed in XME studies. In another subset of 2 studies (including troglitazone), a marked up-regulation of genes involved in peroxisomal fatty acid {beta}-oxidation was noted, associated with induction of genes involved in peroxisome proliferation. Therefore, an increase in peroxisome abundance would be the main mechanism underlying LH noted in this second study subset. Together, the use of transcript profiling provides a means to generate putative mechanistic models underlying the pathogenesis of liver hypertrophy, to distinguish between subtle variations in subcellular organelle proliferation and creates opportunities for improved mechanism-based risk assessment.

60 APPLIED LIFE SCIENCES↗

Forback DC-to-DC converter

A pulse-width modulated DC-to-DC power converter including a first inductor, i.e. a transformer or an equivalent fixed inductor equal to the inductance of the secondary winding of the transformer, coupled across a source of DC input voltage via a transistor switch which is rendered alternately conductive (ON) and nonconductive (OFF) in accordance with a signal from a feedback control circuit is described. A first capacitor capacitively couples one side of the first inductor to a second inductor which is connected to a second capacitor which is coupled to the other side of the first inductor. A circuit load shunts the second capacitor. A semiconductor diode is additionally coupled from a common circuit connection between the first capacitor and the second inductor to the other side of the first inductor. A current sense transformer generating a current feedback signal for the switch control circuit is directly coupled in series with the other side of the first inductor so that the first capacitor, the second inductor and the current sense transformer are connected in series through the first inductor. The inductance values of the first and second inductors, moreover, are made identical. Such a converter topology results in a simultaneous voltsecond balance in the first inductance and ampere-second balance in the current sense transformer.

Lukemire, Alan T.↗

Forback DC-to-DC converter

A pulse-width modulated DC-to-DC power converter including a first inductor, i.e. a transformer or an equivalent fixed inductor equal to the inductance of the secondary winding of the transformer, coupled across a source of DC input voltage via a transistor switch which is rendered alternately conductive (ON) and nonconductive (OFF) in accordance with a signal from a feedback control circuit is described. A first capacitor capacitively couples one side of the first inductor to a second inductor which is connected to a second capacitor which is coupled to the other side of the first inductor. A circuit load shunts the second capacitor. A semiconductor diode is additionally coupled from a common circuit connection between the first capacitor and the second inductor to the other side of the first inductor. A current sense transformer generating a current feedback signal for the switch control circuit is directly coupled in series with the other side of the first inductor so that the first capacitor, the second inductor and the current sense transformer are connected in series through the first inductor. The inductance values of the first and second inductors, moreover, are made identical. Such a converter topology results in a simultaneous voltsecond balance in the first inductance and ampere-second balance in the current sense transformer.

Lukemire, Alan T.↗

Induction of Plant Curvature by Magnetophoresis and Cytoskeletal Changes during Root Graviresponse

High gradient magnetic fields (HGMF) induce curvature in roots and shoots. It is considered that this response is likely to be based on the intracellular displacement of bulk starch (amyloplasts) by the ponderomotive force generated by the HGMF. This process is called magnetophoresis. The differential elongation during the curvature along the concave and convex flanks of growing organs may be linked to the microtubular and/or microfilament cytoskeleton. The possible existence of an effect of the HGMF on the cytoskeleton was tested for, but none was found. The application of cytoskeletal stabilizers or depolymerizers showed that neither microtubules, nor microfilaments, are involved in the graviresponse.

Hasenstein, Karl H.↗

Fundamental studies on initiation and evolution of multi-channel discharges and their application to next generation pulsed power machines.

Future pulsed power systems may rely on linear transformer driver (LTD) technology. The LTD's will be the building blocks for a driver that can deliver higher current than the Z-Machine. The LTD's would require tens of thousands of low inductance ( %3C 85nH), high voltage (200 kV DC) switches with high reliability and long lifetime ( 10 4 shots). Sandia's Z-Machine employs 36 megavolt class switches that are laser triggered by a single channel discharge. This is feasible for tens of switches but the high inductance and short switch life- time associated with the single channel discharge are undesirable for future machines. Thus the fundamental problem is how to lower inductance and losses while increasing switch life- time and reliability. These goals can be achieved by increasing the number of current-carrying channels. The rail gap switch is ideal for this purpose. Although those switches have been extensively studied during the past decades, each effort has only characterized a particular switch. There is no comprehensive understanding of the underlying physics that would allow predictive capability for arbitrary switch geometry. We have studied rail gap switches via an extensive suite of advanced diagnostics in synergy with theoretical physics and advanced modeling capability. Design and topology of multichannel switches as they relate to discharge dynamics are investigated. This involves electrically and optically triggered rail gaps, as well as discrete multi-site switch concepts.

Schwarz, Jens↗

Effects of FGF-2 on human adipose tissue derived adult stem cells morphology and chondrogenesis enhancement in Transwell culture

Highlights: Black-Right-Pointing-Pointer We investigated effects of FGF-2 on hADSCs. Black-Right-Pointing-Pointer We examine changes in the level of gene expressions of SOX-9, aggrecan and collagen type II and type X. Black-Right-Pointing-Pointer FGF-2 induces chondrogenesis in hADSCs, which Bullet Increasing information will decrease quality if hospital costs are very different. Black-Right-Pointing-Pointer The result of this study may be beneficial in cartilage tissue engineering. -- Abstract: Injured cartilage is difficult to repair due to its poor vascularisation. Cell based therapies may serve as tools to more effectively regenerate defective cartilage. Both adult mesenchymal stem cells (MSCs) and human adipose derived stem cells (hADSCs) are regarded as potential stem cell sources able to generate functional cartilage for cell transplantation. Growth factors, in particular the TGF-b superfamily, influence many processes during cartilage formation, including cell proliferation, extracellular matrix synthesis, maintenance of the differentiated phenotype, and induction of MSCs towards chondrogenesis. In the current study, we investigated the effects of FGF-2 on hADSC morphology and chondrogenesis in Transwell culture. hADSCs were obtained from patients undergoing elective surgery, and then cultured in expansion medium alone or in the presence of FGF-2 (10 ng/ml). mRNA expression levels of SOX-9, aggrecan and collagen type II and type X were quantified by real-time polymerase chain reaction. The morphology, doubling time, trypsinization time and chondrogenesis of hADSCs were also studied. Expression levels of SOX-9, collagen type II, and aggrecan were all significantly increased in hADSCs expanded in presence of FGF-2. Furthermore FGF-2 induced a slender morphology, whereas doubling time and trypsinization time decreased. Our results suggest that FGF-2 induces hADSCs chondrogenesis in Transwell culture, which may be beneficial in cartilage tissue engineering.

60 APPLIED LIFE SCIENCES↗

Functional characterization of Kaposi's sarcoma-associated herpesvirus small capsid protein by bacterial artificial chromosome-based mutagenesis

A systematic investigation of interactions amongst KSHV capsid proteins was undertaken in this study to comprehend lesser known KSHV capsid assembly mechanisms. Interestingly the interaction patterns of the KSHV small capsid protein, ORF65 suggested its plausible role in viral capsid assembly pathways. Towards further understanding this, ORF65-null recombinant mutants (BAC-{Delta}65 and BAC-stop65) employing a bacterial artificial chromosome (BAC) system were generated. No significant difference was found in both overall viral gene expression and lytic DNA replication between stable monolayers of 293T-BAC36 (wild-type) and 293T-BAC-ORF65-null upon induction with 12-O-tetradecanoylphorbol-13-acetate, though the latter released 30-fold fewer virions to the medium than 293T-BAC36 cells. Sedimentation profiles of capsid proteins of ORF65-null recombinant mutants were non-reflective of their organization into the KSHV capsids and were also undetectable in cytoplasmic extracts compared to noticeable levels in nuclear extracts. These observations collectively suggested the pivotal role of ORF65 in the KSHV capsid assembly processes.

60 APPLIED LIFE SCIENCES↗

Numerical Investigation of the Spark Discharge Process in a Crossflow

The present study numerically investigates the spark discharge process under crossflow conditions using a thermal equilibrium plasma solver that fully couples the electromagnetic physics and fluid dynamics in a computational framework. Numerical results are validated by the comparison with experimental data. Here, the spark discharge experiment is performed in a constant volume vessel using an inductive coil ignition system for automotive applications, and the evolution of the spark channel is measured using high-speed imaging. The crossflow in the gap between the spark-plug electrodes is generated by a rotating fan with two different fan speeds, and the flow velocity across the gap is characterized by particle image velocimetry (PIV) measurement. A computational fluid dynamics (CFD) solver is employed to simulate the crossflow and provide the flow field variables (velocity, pressure, temperature) to the plasma solver. The crossflow velocity predicted in the flow simulation agrees well with the PIV data in that the non-uniform velocity profiles at monitoring points are reproduced by the CFD code. With the crossflow initialization in the plasma solver, the simulated spark discharge process from the breakdown to spark discharge matches the experimental data, including the voltage and circuit waveforms and the high-speed images of the spark channel evolution. The stretch of spark channel captured by plasma simulations agrees with the measured data. The plasma simulation reveals that the mean temperature of the spark channel is maintained at 5000 K during the discharge phase, and the temperature varies along the spark channel so that the highest value is obtained at the spark root on the center electrode. Overall, the results presented in this paper are meant to provide valuable information about the properties of the plasma generated by the spark discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗