Search NASA⌕ Search

SEARCH · Search NASA

Results for “inverted data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Reconstruction of the mutual coherence function for a moving source

The acoustic radiation of a randomly fluctuating source in motion is characterized analytically to determine the mutual coherence function (MCF). A far-field relation is derived via a series of invertible transformations, and a higher-dimension Radon transformation is performed to reconstruct the MCF; explicit formulas for computing the MCF from the transformed radiation data are provided. The technique is applied to the cases of an axisymmetric line source of finite extent moving at constant velocity along a line and a spatially incoherent line source. Applications to X-ray tomography and analysis of the noise emitted by a moving jet aircraft are suggested.

Chow, P. L.↗

Inversion of limb radiance measurements - An operational algorithm

The limb radiance inversion radiometer (LRIR) and limb infrared monitor of the stratosphere (LIMS) experiments aboard the Nimbus 6 and 7 spacecraft have made observations of infrared emission by CO2, O3, H2O, HNO3, and NO2 at the earth's limb. This paper describes a method by which such measurements can be inverted to give vertical distributions of temperature and mixing ratios as functions of pressure. The simple and efficient approach was successfully applied to the LRIR data and subsequently in the initial assessment of the LIMS data. Inversion of synthetic data indicates the size of the errors to be expected as a result of the assumptions and instrumental errors. Retrievals of measured LIMS radiances are shown as examples and compared to in situ observations. The differences are comparable to those obtained with the more complex retrieval scheme used to process the LIMS archival products. Some problems are noted.

Bailey, P. L.↗

PV Field Performance Including Fleet and Bifacial Field Data

This presentation provides a review of two recent presentations - the 2021 PV Fleet Performance Data Initiative covered by the PVRW presentation, and bifacial system performance presented to a February DuraMAT working group. Details include degradation rate distributions from >6000 inverter channels, monthly performance vs expected, bifacial field studies of energy gain and field degradation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Securing the Modern Grid: Federal Investments, Digitization, and Supply Chain Strategy

Across the United States (U.S.) grid expansion and modernization is underway, paving the way for accelerated load growth and intelligent resource management. Digitization of the grid is supported by several state and federal programs, providing support for utilities installing advanced metering infrastructure (AMI), AI-powered analytics systems, battery energy storage systems (BESS), and distributed energy resource management systems (DERMS) to transform the grid from a one-way power delivery system into an intelligent, responsive network that will enable faster load growth and power expansion of data centers for advanced artificial intelligence (AI) applications. The digital transformation of America's grid presents opportunity for increased efficiency and resiliency but also introduces new digital risks that require careful management. Digital equipment often contains several vulnerabilities such as unencrypted communication protocols, and persistent remote access capabilities that could be exploited to manipulate device settings, coordinate service disruptions, or inject false data into grid operations. These digital risks become particularly important as the grid must rapidly scale to support AI-driven data centers, which the administration has identified as essential for maintaining U.S. technological leadership and economic competitiveness. These vulnerabilities are compounded by supply chain realities: Chinese manufacturers currently produce 70-90% of essential grid components including inverters, batteries, and control systems, with the U.S. lacking domestic manufacturing capacity for critical assets like extra-high voltage transformers. Recent federal legislation has established Foreign Entity of Concern (FEOC) restrictions to address these risks, requiring projects to achieve escalating thresholds of non-FEOC content to receive tax credits while utilities work to expand sourcing channels for their supply chains and strengthen security measures. These restrictions arrive precisely when utilities face unprecedented electricity demand growth driven by the rapid growth in data centers, creating a considerable challenge: rapidly expanding infrastructure while navigating complex compliance requirements while lacking viable alternatives for many critical components. Idaho National Laboratory (INL) and its partners have developed practical approaches to help utilities navigate these intersecting challenges as they leverage federal investment to strengthen and grow the grid. These solutions include Cyber-Informed Engineering (CIE) principles that build resilience directly into systems, the Cirrus tool for secure cloud migration, and enhanced procurement guidance that embeds security requirements throughout equipment lifecycles. Federal initiatives, such as the Technical Assistance for Digital Assurance (TADA) project, provide direct support to utilities implementing these approaches while facilitating knowledge sharing across the industry. While these tools and frameworks cannot eliminate all risks inherent in foreign supply chain dependencies, they offer pragmatic pathways for strengthening security posture without sacrificing the deployment momentum essential to meeting surging electricity demand. Ultimately, securing America's digital energy infrastructure demands dedicated coordination across multiple fronts: building domestic supply chains, implementing robust digital assurance practices, and maintaining the aggressive modernization timeline necessary for reliability, resilience, and energy independence.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Dynamic Modeling of Smart Inverter

This letter proposes a novel hybrid method for assessing grid-connected three-phase converter interfaced resources (CIR) dynamics with the IEEE standard 1547-2018 grid support functions (GSFs), which blends physics and data-driven techniques. First, the letter derives an analytical model of a CIR to represent the internal physics and data-driven model (DDM) using a system identification algorithm to represent the rest of the dynamics, including the GSF. The derived hybrid model combines the analytical model of CIR and DDM, which balances accuracy and flexibility and is compared with the detailed switched model. Furthermore, the efficacy of the proposed approach to represent the advanced CIR dynamics is substantiated by power hardware-in-the-loop experiment data where real measurements from a commercial CIR are used to cross-validate the proposed approach. Furthermore, the results indicate that despite simple, the hybrid model accurately reproduces the dynamics of the detailed CIR model with an acceptable accuracy.

Data-driven model↗

Evaluation of Runtime Performance for xRage Equations of State Input Settings and Cropped EOS Tables

Using the xRage hydro code with its intrinsic equations of state (EOS) settings does not produce the most accurate representation of the problem due to xRage's internal alterations to the fundamental EOS data. Utilizing EOSPAC with default settings in the hydro code uses the unaltered EOS SESAME data to produce what is considered the most accurate results. However, this setup for the simulation is very computationally inefficient due to xRage's reliance on pressure and temperature as its look-up variables in combination with EOSPAC's use of a rational function interpolator. This report explores the results and performance of running a simulation with the option, within EOSPAC, to invert the table at setup, using a linear or rational interpolator, and using an EOS table cut down to only the region actually sampled in the problem. Air and Deuterium are used as the test materials for the simulations. While using EOS data directly with EOSPAC, the rational interpolator takes about twice as long as the linear one. Additionally, using a windowed EOS table does not show a large increase in performance. An EOS table that has had more energy grid points interpolated and added in by EOSPAC showed more accurate results, suggesting that a more dense EOS table would be more accurate.

97 MATHEMATICS AND COMPUTING↗

A Robust Method to Secure Multi-Inverter Grid Tied PV and Battery Energy Storage Systems Against Cyber Intrusions

This paper details a robust method to secure a multi-inverter grid tied system that interfaces photovoltaic (PV) and battery energy storage against potential cyber-attacks. The method can be applied to any third-party inverter systems without a need to modify their internal controls. A small random private excitation signal termed "watermark" is injected into the DC input voltage terminals (via a series transformer) connected to the PV/battery inverter system. An external robust cyber intrusion detector (CID) hardware consisting of a digital signal processor (DSP) generates the "watermark" and also receives the sensor signals that control the setpoints of the PV/battery grid tied system. The CID algorithm is shown to detect all possible cyber intrusions (such as false data injection(FDI)) on external sensor signals such as P and Q measured by a smart meter that control the overall system operation. The proposed CID computes online system ID and two variance tests in real time on each sensor signal and is able pinpoint intrusion location in a multi-inverter system. Results on a hardware in the loop (HIL) of a two-inverter grid connected system demonstrate effectiveness of the proposed CID system for FDI and unobservable FDI. Test results on a laboratory prototype will be discussed in the conference presentation.

Ibrahim, Hasan↗

Interpretation of Tracer Experiments on Inverted Five-spot Well-patterns within the Western Half of the Farnsworth Unit Oil Field

The Southwest Carbon Partnership (SWP), one of the U.S. Department of Energy (U.S. DOE) seven Regional Carbon Sequestration Partnerships, is currently working to demonstrate the utilization and storage of CO 2 in the Farnsworth Unit (FWU) Enhanced Oil Recovery (EOR) site under the final development phase of this U.S. DOE initiative. A component of the research is to use fluid tracers to understand the multifluid flow patterns that develop between injection and production wells via collected field data and supporting numerical reservoir models. The FWU, located in the Anadarko Basin, Ochiltree County, Texas, and being operated by Chaparral Energy, is a mature EOR water-flood field, which is currently being converted to a CO 2 flow, with inverted 5-spot patterns transitioning from pure water to alternating CO 2 and water floods (i.e., water alternating gas (WAG)) at an approximate rate of one every 6 to 10 months. The SWP tracer program is conducting a suite of tracer injections into the active 5-spot patterns at the FWU. Tracers have been selected to be nonreactive and either principally soluble in CO 2 (gas soluble) or water (aqueous soluble). In addition to characterizing the multifluid flow behaviour within reservoir, the gas and aqueous tracers have roles in detecting any leakage from the reservoir. A total of seven unique perfluorocarbon tracer (PFT) compounds make up the suite of gas soluble tracers and eight unique naphthalene sulfonate tracer (NPT) compounds comprise the aqueous soluble tracers. Lastly, all selected tracers are significantly detectable below the parts per billion concentrations, allowing for high resolution for the inter-well tests at relatively low injection volumes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900-MHz LTE network↗

Recent Development of Frequency Estimation Methods for Future Smart Grid

The frequency estimated by the Phasor Measurement Unit (PMU) is a critical index of power system status and supports many smart grid applications. The future smart grid features high penetration of renewables and more fast-moving power electronics inverters but raises challenges to the reliable frequency estimation. This article presents three methods to address these challenges. First, an enhanced zero-crossing algorithm was developed to track the fast-changing frequency in system dynamics. Second, we propose a technology that can tolerate the system transient and suppress the outliers. Third, an algorithm was developed to export high time-resolution frequency estimations with minimum computational effort. All of the proposed methods are realized in hardware and compared with classical frequency estimation methods. The testing results indicate that the proposed methods have excellent performance. They can be used in future PMUs and provide reliable and high time resolution data for smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of the orientation of stress in the Earth’s crust without earthquake or borehole data

Abstract Mechanical stress acting in the Earth’s crust is a fundamental property that is important for a wide range of scientific and engineering applications. The orientation of maximum horizontal compressive stress can be estimated by inverting earthquake source mechanisms and measured directly from borehole-based measurements, but large regions of the continents have few or no observations. Here we present an approach to determine the orientation of maximum horizontal compressive stress by measuring stress-induced anisotropy of nonlinear susceptibility, which is the derivative of elastic modulus with respect to strain. Laboratory and Earth experiments show that nonlinear susceptibility is azimuthally dependent in an anisotropic stress field and is maximum in the orientation of maximum horizontal compressive stress. We observe this behavior in the Earth—in Oklahoma and New Mexico, U.S.A, where maximum nonlinear susceptibility coincides with the orientation of maximum horizontal compressive stress measured using traditional methods. Our measurements use empirical Green’s functions and solid-earth tides and can be applied at different temporal and spatial scales.

58 GEOSCIENCES↗

Test-Based Modeling of Photovoltaic Inverter Impact on Distribution Systems

Distributed PV has important effects on overcurrent, overvoltage and islanding protection. These effects are more difficult to analyze because the faulted behavior of PV inverters is less well understood than for rotating machines. Full transient models of the inverter can be accurate, but that approach requires inverter design details and simulation software that doesn’t easily interoperate with utility protection system software. Further, anomalous model behaviors often emerge at different grid conditions, and these are difficult to fix in a proprietary model. Testing provides another approach to characterize inverters, validate models or answer questions of application. This earlier work found major impacts from the inverter design, firmware, operating point and balance-of-system components. Our objective is to characterize PV inverters from black-box testing, leading to standard test reports that could provide parameter sets for widely-implemented models in software tools. The tool vendors can then develop standard inverter models, as they did for rotating machines and exciters. Besides fully detailed transient models, inverters can be represented with steady-state current sources, dynamically controlled current sources or non-linear frequency-dependent black boxes. Type-test data could support the last three kinds of model. Short circuit and sag tests would encompass the basic fault types, reporting the maximum transient and rms currents over all power levels and points-on-wave within four time ranges : 1) 0 to 1 cycles, for close and latch consideration 2) 1 to 4 cycles, for equipment withstand 3) 4 to 30 cycles, for interrupt ratings 4) 30 cycles and beyond, for backup protection analysis Open circuit tests would vary output power and power factor, and report the maximum rms voltage from 1 to 10 cycles after the event. Without models, the type-test data could also provide upper limits on the expected overvoltages and overcurrents.

Wieserman, Laura M.↗

Development of an Encoding Method on an Co-simulation Platform for Mitigating the Impact of Unreliable Communication

This report presents a hardware-in-the-loop (HIL) based modeling approach for simulating impacts of unreliable communication on the performance of centralized volt-var control and for developing an encoding method to mitigate the impacts. First, an asynchronous real-time HIL simulation platform is introduced to enable multi-rate co-simulation of a distribution system with many inverter-based distributed energy resources (DERs). The distribution system is modeled by milliseconds phasor-based models and the DERs are modeled by micro-seconds power electronic models. Communication connections between a centralized volt-var controller (modeled externally to the HIL testbed) and smart inverters are built by implementing Modbus links and the Long Term Evolution network. On this co-simulation platform, an enhanced, augmented Lagrangian multiplier based encoded data recovery (EALM-EDR) algorithm for mitigating the impact of unreliable communication is developed and validated. Simulation results demonstrate the efficacy of using the HIL-based co-simulation platform as a power grid digital twin for developing algorithms that coordinate a large number of heterogeneous control systems through wired and wireless communication links.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Acoustic Source Parameters and Yield Estimation for SPE Phase I and Forensics Surface Events

Acoustic signals recorded for explosive events are sensitive to pressure changes in the source region and can provide valuable information about source characteristics. However, acoustic wave propagation in the atmosphere is significantly affected by weather conditions (e.g., temperature, pressure, and wind), and the atmospheric propagation effects should be considered properly to obtain accurate source information. Acoustic waveform inversion method has been increasing useful to determine quantitative source parameters by incorporating accurate Green’s function into the inversion and by effectively removing propagation path effects. This paper reviews recent progress in the acoustic waveform inversion and its application to explosion yield/emplacement (e.g., height-of-burst or depth-of-burial) estimation. The inversion method is applied to acoustic signals recorded during Source Physics Experiment Phase I and Forensics Surface Event conducted at the Nevada National Security Site (NNSS). Inverted acoustic source strengths are related to the explosion yield and emplacement, and their estimation uncertainties are explored by the comparison with the ground-truth data.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Distributed Solar 2020 Data Update [Slides]

Berkeley Lab’s Tracking the Sun report summarizes installed prices and other trends among grid-connected, distributed solar photovoltaic (PV) systems in the United States. This report is now being published on a biannual cycle. In 2020, Berkeley Lab has released a more limited Distributed Solar 2020 Data Update, which consists of the same data otherwise published in Tracking the Sun report. The update includes data on more than 1.9 million systems installed through 2019, covering 82% of all distributed PV systems installed nationally through that timeframe.As in prior years, the data update focuses to a large degree on installed prices reported for distributed PV projects, describing both historical trends and variability in pricing across projects.With respect to the historical price trajectory, national median installed prices fell, from 2018 to 2019, by roughly 1% for residential systems, remained essentially flat for small non-residential systems, and fell by 4% for large non-residential systems. Across all three customer segments, these are the slowest annual percentage declines since 2006-2008.Pricing continues to vary widely across individual projects, reflecting, among other things, differences in system sizing and design, installer-level pricing strategies, and local market conditions. For example, among residential systems installed in 2019, the lowest 20% were priced below $3.1/W, while the highest 20% were above $4.5/W. The distributions for non-residential systems exhibit similarly wide spreads.In addition to data on installed prices, the data update also covers a broad range of trends related to distributed PV system design, including: system sizing, module efficiency, module-level power electronics, inverter-loading ratios, solar+storage installations, mounting configuration, panel orientation, third-party ownership, and customer segmentation.

14 SOLAR ENERGY↗

Definition study for photovoltaic residential prototype system

A parametric sensitivity study and definition of the conceptual design is presented. A computer program containing the solar irradiance, solar array, and energy balance models was developed to determine the sensitivities of solar insolation and the corresponding solar array output at five sites selected for this study as well as the performance of several solar array/battery systems. A baseline electrical configuration was chosen, and three design options were recommended. The study indicates that the most sensitive parameters are the solar insolation and the inverter efficiency. The baseline PST selected is comprised of a 133 sg m solar array, 250 ampere hour battery, one to three inverters, and a full shunt regulator to limit the upper solar array voltage. A minicomputer controlled system is recommended to provide the overall control, display, and data acquisition requirements. Architectural renderings of two photovoltaic residential concepts, one above ground and the other underground, are presented. The institutional problems were defined in the areas of legal liabilities during and after installation of the PST, labor practices, building restrictions and architectural guides, and land use.

Imamura, M. S.↗

On the spectrum of the secondary auroral electrons

Results are presented from a statistical study of the spectral characteristics of the (power-law-portion) secondary electrons associated with inverted-V electron precipitation events (IVEs). A total of 106 IVEs observed at low altitudes (below 1000 km) by the DE 2 spacecraft are included in data base. Spectral parameters for the electrons between 20 eV and 100 eV are plotted against the different parameters pertaining to the locations of the IVEs and the primary beams to determine their empirical dependences. It is found that the differential spectrum of the secondary electrons can be modeled by a power law, J proportional to E exp -gamma, with an averaged gamma of 1.85. This spectral parameter is relatively insensitive to the variation of locations of the IVEs, but it depends on the primary beam parameters. These results are compared with predictions, and theories on the generation of the low-energy auroral power-law secondary electrons are assessed. The analysis shows that collisional processses are the dominant source of the secondary electrons.

Fung, S. F.↗

Flare heating and ionization of the low solar chromosphere. I - Inversion methods for Mg I 4571 and 5173

Various methods of inverting solar Mg I 4571 and 5173 spectral line observations are examined to find the best method of using these lines to calculate the vertical temperature and electron density structure around the temperature minimum region. Following a perturbation analysis by Mein (1971), a Fredholm integral equation of the first kind is obtained which can be inverted to yield these temperature and density structures as a function of time. Several inversion methods are tested and compared. The methods are used to test data as well as to a subset of observations of these absorption lines taken on February 3, 1986 before and during a solar flare. A small but significant increase is found in the temperature and a relatively large increase in the electron density during this flare. The observations are inconsistent with heating and ionization by an intense beam of electrons and with ionization by UV photoionization of Si I.

Metcalf, Thomas R.↗