At least 775 records · Page 43

Photo-thermo-dissociation. I - A general mechanism for destroying molecules

Photothermodissociation (PTD) of an isolated molecule is the name of the process when a photon is absorbed by an electronic transition, the energy is transferred to the vibrations (hot molecule) and then an atom or a fragment is ejected. A statistical physics treatment is presented that goes beyond the thermal approximation and fully takes into account the isolation of the system. A model is given that permits an explicit calculation of the ejection rates of hydrogen and carbon fragments from aromatic molecules as a function of their size and internal energy. Then, the lifetime of species against PTD in different astronomical radiation fields will result when a precise dynamical evolution of their internal energy can be established.

Leger, A.↗

Switching Matrix For Optical Signals

Proposed matrix of electronically controlled shutters switches signals in optical fibers between multiple input and output channels. Size, weight, and power consumption reduced. Device serves as building block for small, low-power, broad-band television- and data-signal-switching systems providing high isolation between nominally disconnected channels.

Grove, Charles H.↗

A convenient technique for polarimetric calibration of single-antenna radar systems

A practical technique for calibrating single-antenna polarimetric radar systems is introduced. This technique requires only a single calibration target such as a conducting sphere or a trihedral corner reflector to calibrate the radar system, both in amplitude and phase, for all linear polarization configurations. By using a metal sphere, which is orientation independent, error in calibration measurement is minimized while simultaneously calibrating the crosspolarization channels. The antenna system and two orthogonal channels (in free space) are modeled as a four-port passive network. Upon using the reciprocity relations for the passive network and assuming the crosscoupling terms of the antenna to be equal, the crosstalk factors of the antenna system and the transmit and receive channel imbalances can be obtained from measurement of the backscatter from a metal sphere. For an X-band radar system with crosspolarization isolation of 25 dB, comparison of values measured for a sphere and a cylinder with theoretical values shows agreement within 0.4 dB in magnitude and 5 deg in phase. An effective polarization isolation of 50 dB is achieved using this calibration technique.

Sarabandi, Kamal↗

Analytical concepts for health management systems of liquid rocket engines

Substantial improvement in health management systems performance can be realized by implementing advanced analytical methods of processing existing liquid rocket engine sensor data. In this paper, such techniques ranging from time series analysis to multisensor pattern recognition to expert systems to fault isolation models are examined and contrasted. The performance of several of these methods is evaluated using data from test firings of the Space Shuttle main engines.

Williams, Richard↗

Fault management for the Space Station Freedom control center

This paper describes model based reasoning fault isolation in complex systems using automated digraph analysis. It discusses the use of the digraph representation as the paradigm for modeling physical systems and a method for executing these failure models to provide real-time failure analysis. It also discusses the generality, ease of development and maintenance, complexity management, and susceptibility to verification and validation of digraph failure models. It specifically describes how a NASA-developed digraph evaluation tool and an automated process working with that tool can identify failures in a monitored system when supplied with one or more fault indications. This approach is well suited to commercial applications of real-time failure analysis in complex systems because it is both powerful and cost effective.

Clark, Colin↗

Ground vibration test of the XV-15 Tiltrotor Research Aircraft and pretest predictions

The first comprehensive ground vibration survey was performed on the XV-15 Tiltrotor Research Aircraft to measure the vibration modes of the airframe and to provide data critical for determining whirl flutter stability margins. The aircraft was suspended by the wings with bungee cords and cables. A NASTRAN finite element model was used in the design of the suspension system to minimize its interference with the wing modes. The primary objective of the test was to measure the dynamic characteristics of the wings and pylons for aeroelastic stability analysis. In addition, over 130 accelerometers were placed on the airframe to characterize the fuselage, wing, and tail vibration. Pretest predictions were made with the NASTRAN model as well as correlations with the test data. The results showed that the suspension system provided the isolation necessary for modal measurements.

Studebaker, Karen↗

Phenol Analysis -- Some Analytical Considerations

Contamination of potable water supplies with halogenated phenols in concentrations of 2-10 parts per billion (ppb) produces objectionable tastes and odors capable of influencing consumer acceptability. Routine analysis by the distillation/ 4-aminoantipyrine method is limited by lack of sensitivity and subject to interference by aryl amines. This has been overcome by developing a continuous liquid-liquid extraction system to selectively isolate phenols and eliminate major interfering substances. Stable reagents have been formulated to reduce blank color and extend sensitivity. Equipment suitable for analysis of phenols at the 1 ppb level or less in 20 minutes is described.

Starkey, R. J., Jr.↗

MEMS Micropropulsion Activities at JPL

A status of MEMS-based micropropulsion activities conducted at JPL will be given. These activities include work conducted on the so called Vaporizing Liquid Micro-Thruster (VLM) which recently underwent proof-of-concept testing, demonstrating the ability to vaporize water propellant at 2 W and 2 V. Micro-ion engine technologies, such m field emitter arrays and micro-grids are being studied. Focus in the field emitter area is on arrays able to survive in thruster plumes and micro-ion engine plasmas to serve as neutralizers aW engine cathodes. Integrated, batch-fabricated Ion repeller grid structures are being studied as well as different emitter tip materials are being investigated to meet these goals. A micro-isolation valve is being studied to isolate microspacecraft feed system during long interplanetary cruises, avoiding leakage and prolonging lifetime and reliability of such systems. This concept relies on the melting of a thin silicon barrier. Burst pressure values as high as 2,900 psig were obtained for these valves and power requirements to melt barriers ranging between 10 - 50 microns in thickness, as determined through thermal finite element calculations, varied between 10 - 30 W to be applied over a duration of merely 0.5 ms.

Mueller, Juergen↗

The Evolution of Disks and Winds in Dwarf Nova Outbursts - FUSE

This project was a project to study the FUV spectra of two proto-typical dwarf novae, U Gem and SS Cygni, through an outburst cycle. The luminosity of the boundary layer in the two systems, as evidenced by earlier EUVE observations, is different in the two systems. Our intensive study of the two systems was intended to (1) probe the ionization and kinematic structure of the wind as a function of system brightness, (2) isolate the contributions of the disk to the FUV spectra, and (3) examine physical conditions and abundances of material just being accreted onto the disk from the secondary. The U Gem and SS Cyg observations took place in March and October 2000, respectively. The data obtained with FUSE was of excellent quality. Analysis of the both observations is now essentially complete, although some modeling of the SS Cyg spectra is ongoing, as we complete an ApJ manuscript on this object. Our main results for U Gem are as follows: The plateau spectra have continuum shapes and fluxes that are approximated by steady state accretion disk model spectra with an accretion rate 7x10(exp 9) Msolar/yr. The spectra also show numerous absorption lines of H I, He II, and 2-5 times ionized transitions of C, N, O, P, S, and Si. There are no emission features in the spectra, with the possible exception of a weak feature on the red wing of the 0 VI doublet. The absorption lines are narrow (FWHM approx. 50 km/s), too narrow to arise from the disk photosphere, and at low velocities (less than or equal to 700 km/s). The S VI and O VI doublets are optically thick. The absorption lines in the plateau spectra show orbital variability: in spectra obtained at orbital phases between 0.53 and 0.79, low-ionization absorption lines appear and the central depths of the preexisting lines increase. The increase in line absorption occurs at the same orbital phases as previously observed EUV and X-ray light-curve dips. If the absorbing material is in (near-) Keplerian rotation around the disk, it must be located at large disk radii. The final observation occurred when U Gem was about 2 mag from optical quiescence. The spectra are dominated by emission from an approx. 43,000 K, metal-enriched white dwarf (WD). The inferred radius of the WD is 4.95x10(exp 8) cm, close to that observed in quiescence. Allowing for a hot heated region on the surface of the WD improves the fit to the spectrum at short (less than 960 A) wavelengths. Our main results for SS Cyg are as follows: The first two of four observations of SS Cyg show disk dominated spectra with accretion rates of order 10(exp -8) Msolar/yr. Except for narrow interstellar features (atomic and molecular H), the lines are all broad consistent with a disk or wind origin. The O VI line in the spectra is mostly of wind origin as detailed modeling with our Monte Carlo code (developed in part using funds from this project) show. The continua from spectra in observations 3 and 4, observed during the decline phase, are not well fit with steady-state disks, and show considerable resemblance to quiescent spectra obtained with HUT. The most probable interpretation for the emission features seen in the spectrum in the last two observations is that they arise from a photo-illuminated choronosphere above the disk, rather than a wind.

Long, Knox↗

Evaluating Suit Fit Using Performance Degradation

The Mark III suit has multiple sizes of suit components (arm, leg, and gloves) as well as sizing inserts to tailor the fit of the suit to an individual. This study sought to determine a way to identify the point an ideal suit fit transforms into a bad fit and how to quantify this breakdown using mobility-based physical performance data. This study examined the changes in human physical performance via degradation of the elbow and wrist range of motion of the planetary suit prototype (Mark III) with respect to changes in sizing and as well as how to apply that knowledge to suit sizing options and improvements in suit fit. The methods implemented in this study focused on changes in elbow and wrist mobility due to incremental suit sizing modifications. This incremental sizing was within a range that included both optimum and poor fit. Suited range of motion data was collected using a motion analysis system for nine isolated and functional tasks encompassing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm only. The results were then compared across sizing configurations. The results of this study indicate that range of motion may be used as a viable parameter to quantify at what stage suit sizing causes a detriment in performance; however the human performance decrement appeared to be based on the interaction of multiple joints along a limb, not a single joint angle. The study was able to identify a preliminary method to quantify the impact of size on performance and to develop a means to gauge tolerances around optimal size. More work is needed to improve the assessment of optimal fit and to compensate for multiple joint interactions.

Margerum, Sarah E.↗

Evaluating Suit Fit Using Performance Degradation

The Mark III planetary technology demonstrator space suit can be tailored to an individual by swapping the modular components of the suit, such as the arms, legs, and gloves, as well as adding or removing sizing inserts in key areas. A method was sought to identify the transition from an ideal suit fit to a bad fit and how to quantify this breakdown using a metric of mobility-based human performance data. To this end, the degradation of the range of motion of the elbow and wrist of the suit as a function of suit sizing modifications was investigated to attempt to improve suit fit. The sizing range tested spanned optimal and poor fit and was adjusted incrementally in order to compare each joint angle across five different sizing configurations. Suited range of motion data were collected using a motion capture system for nine isolated and functional tasks utilizing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm by itself. Findings indicated that no single joint drives the performance of the arm as a function of suit size; instead it is based on the interaction of multiple joints along a limb. To determine a size adjustment range where an individual can operate the suit at an acceptable level, a performance detriment limit was set. This user-selected limit reveals the task-dependent tolerance of the suit fit around optimal size. For example, the isolated joint motion indicated that the suit can deviate from optimal by as little as -0.6 in to -2.6 in before experiencing a 10% performance drop in the wrist or elbow joint. The study identified a preliminary method to quantify the impact of size on performance and developed a new way to gauge tolerances around optimal size.

Margerum, Sarah E.↗

Benefits, Consequences, and Uncertainties of Conventional (Exercise) Countermeasure Approaches

This presentation will review the pros, cons, and uncertainties of using exercise countermeasures in hypothetical long duration exploration missions. The use of artificial gravity and exercise will be briefly discussed. One benefit to continued use of exercise is related to our extensive experience with spaceflight exercise hardware and programming. Exercise has been a part of each space mission dating back to the 1960's when simple isometric and bungee exercises were performed in the Gemini capsule. Over the next 50 years, exercise hardware improved cumulating in today's ISS suite of exercise equipment: Cycle Ergometer with Vibration Isolation and Stabilization System (CEVIS), Treadmill (T2) and Advanced Resistive Exercise Device (ARED). Today's exercise equipment is the most robust ever to be flown in space and allows the variety and intensity of exercise that might reasonably be expected to maintain muscle mass and function, bone density and cardiovascular fitness. A second benefit is related to the large body of research literature on exercise training. There is a considerable body of supporting research literature including >40,000 peer reviewed research articles on exercise training in humans. A third benefit of exercise is its effectiveness. With the addition of T2 and ARED to our ISS exercise suite, crew member outcomes on standard medical tests have improved. Additionally exercise has other positive side effects such as stress relief, possible improvement of immune function, improved sleep, etc. Exercise is not without its consequences. The major cons to performance of in‐flight exercise are the time and equipment required. Currently crew are scheduled 2.5 hrs/day for exercise and there is considerable cost to develop, fly and maintain exercise hardware. While no major injuries have been reported on ISS, there is always some risk of injury with any form of exercise There are several uncertainties going forward; these relate mostly to the development of small compact robust effective exercise devices for the next generation of space vehicles. It is becoming increasingly apparent that high intensity exercise is required for maintenance of fitness and functional capability and so future hardware will need to be developed, tested and implemented that allow for a wide variety of exercise, at high intensity while likely involving low mass, volume and power. There are many unanswered issues related to the minimum number and type of exercise devices required for exploration, optimizing exercise prescriptions for these devices, whether a treadmill is absolutely required, and even whether any single countermeasure can adequately protect muscle, bone, cardiovascular and sensorimotor function.

Ploutz-Snyder, Lori↗

Multibody Based Digital Astronaut Dynamics Simulation

BACKGROUND: This study provides the Software, Robotics, & Simulation Division at the NASA Johnson Space Center with a verification tool for multibody dynamics simulation requiring human motion. The motivation stems from current studies of several Vibration Isolation & Stabilization(VIS)system designs that attenuate the moments and forces which would be transmitted to a spacecraft during an exercise. A multibody dynamics model for a proposed VIS was available previously[1], therefore modeling of the VIS was not needed for this work. The interest here is in creating the multibody dynamics model of an astronaut in motion which may be utilized independently or while attached to a mechanism. An existing simulation [2] that utilizes OpenSim [3,4] and an in-house multibody dynamics package (MBDyn) [5] is used in order to verify the astronaut model. The main advantage this model will have over the existing simulation is that everything will be processed in one tool. METHODS AND RESULTS: Creating the simulation required; estimation of Body Segment Inertial Parameters (BSIP),a multibody model of the human-VIS system, joint acceleration profiles, and input files for MBDyn, which is used for this analysis. The scaling factors provided by Dumas et al. [6] are utilized in estimating the BSIP. Anthropometric data are used for estimating these parameters, the Anthropometric Survey of US Army Personnel (ANSUR II) [7] was the source. The astronaut model consists of 15 bodies, 14 joints and 32 degrees of freedom, with the dynamics topology generated using the center of mass locations and anthropometric data. MBDyn has an option for prescribed joint motion (PJM), which requires joint acceleration data as input. The joint angle data is first obtained from a motion capture system and then processed through code that has been created to generate approximate joint acceleration profiles. The topology tree for the astronaut model begins at the right foot up to the pelvis where there is one branch for going down the left leg and another for the torso. The torso branch leads to branches for the arms and a leaf body for the head/neck segment. For attachment to the VIS, the heel of the right foot is connected to the VIS platform through a fixed joint, resembling a foot restraint. The left foot does not attach to the platform in order to prevent a system with a closed loop. Topology and symmetry of the astronaut model were verified through kinematic analysis. Further verification of the forces and moments transmitted to the VIS were verified against the existing simulation. There was a satisfactory level of agreement when testing a simple motion, for example, rocking back and forth. Full exercise motions are to be tested soon. The main outcome has been a novel application of MBDyn for biomechanics modeling that is now available for dynamic simulations involving human motion. The estimation of BSIP was another useful result of this study, requiring only 15 inputs for generating mass properties of a theoretical astronaut model. Expansion on this work is possible by going through an alternative route in obtaining the joint motion data. Instead of high-tech and often expensive motion capture systems, an individual may watch videos with high focus and at a slow motion for each individual segment in order to determine the initial and final time and angle for that specific degree of freedom. Synthetic trajectories may also be created if there is no video reference available.

F N Matari↗

Recent Improvements and Verification of A Full Body Model in Opensim

BACKGROUND: The dynamic feasibility [1,2] criterion, that the subject’s Center of Pressure (COP) be located within the Base of Support (BOS) which outlines the feet, has aided in assessing the stability of human motion recorded on earth while performing the recorded tasks in lunar gravity or as countermeasures exercises on a vibration isolation and stabilization system in microgravity. The convex hull of the BOS on the platform under the subject’s feet was estimated using virtual markers on the feet of the scaled subject model. The COP was calculated using the ground reaction forces and moments determined from motion capture data with biomechanical modeling tools [3]. Occasionally, large-amplitude oscillatory spikes or “artifacts” were observed in the subject’s linear and angular momentum derivatives, affecting some COP data derived from motion capture. The purpose of this investigation was to assess and improve the accuracy of model scaling and BOS estimation as well as to determine the efficacy of model adjustments in mitigating artifacts influencing motion capture-derived ground reaction force and COP results. METHODS: To aid evaluation of proposed process and model updates, motion capture data were collected for two subjects during unit test and range of motion trials, lunar tasks, and countermeasures exercise motions. Markers were added to the full body Plug-in Gait marker set [4] during data collection. New markers were placed on the front, back, sides, and top of the head to improve scaling using distances between marker pairs. Medial elbow markers were added to stabilize the upper arm during OpenSim Inverse Kinematics (IK) [5]. Finally, markers were added on the outer edge of the heels and on the outside edges of the first and last toes on each foot. These additional foot markers were made available to test new automated foot scaling techniques and to calculate the error between the subject’s estimated and recorded BOS. The modified unscaled OpenSim Full Body Rajagopal Model [6,7] was adjusted using some previously investigated techniques [8] to mitigate rapid shifts in joint angles occurring during IK, as these were found to cause the spike artifacts observed in subsequent stages of analysis. Since OpenSim models use Euler angles and rotation sequences, the arm axes of rotation were adjusted, and the pelvis order of rotation was changed to minimize the likelihood of encountering “gimbal lock” during common human motion. The model clavicle, arm, elbow, wrist, pelvis, and ankle angle limits were adjusted to better accommodate the full human range of motion seen in exercise and lunar data. The shoulder joint center was calculated using a “pivoting” algorithm [9], and both shoulder joint center and upper arm markers were included during IK to provide additional shoulder stability on a case-by-case basis. The quality of IK results was assessed by three criteria: minimizing error between recorded motion capture markers and model markers, checking for reasonable rates of change in joint angles between fames (i.e., no IK artifacts), and ensuring the absence of spikes in the inertial forces and angular momentum derivatives calculated using a custom OpenSim plugin [10]. RESULTS: The additional markers placed on the subject during data collection allowed the head and feet to be scaled more accurately using distances between new marker pairs. Scaling with BOS markers placed on the subject and removing the limit on subtalar angle resulted in more accurate BOS determination. Unrealistically large changes in joint angles between frames could be reduced by including clavicle, sternum, and medial elbow markers during IK. In cases with large arm ranges of motion, results could be further improved by running IK using medial elbow and virtual shoulder joint center markers. Model adjustments significantly improved the IK results affecting COP calculation and increased the accuracy of BOS estimation.

C A Bell↗

Motor and drive arrangement for refrigeration system

A heat exchanger system includes a heat exchanger coil circulating a first heat transfer fluid therethrough, and a fan at least partially surrounded by the heat exchanger coil to urge a flow of air through the heat exchanger coil to dissipate thermal energy from the first heat transfer fluid. A brushless direct current fan motor is located the fan to urge rotation of the fan and an ancillary electrical component operably connected to the heat exchanger system and electrically isolated from the first heat transfer fluid.

Feng, Yinshan↗

Distribution, Ecology, Life History, and Conservation Status of the Berry Cave Salamander (Gyrinophilus gulolineatus)

The Berry Cave Salamander (Gyrinophilus gulolineatus) is a neotenic, stygobitic salamander endemic to eight cave systems and an isolated surface record in the Appalachian Valley and Ridge of eastern Tennessee. We conducted surveys for G. gulolineatus from 2017–2019 to assess the status of the species, locate new populations, and address knowledge gaps related to life history and population ecology required for conservation assessment. We confirmed G. gulolineatus presence at four historical sites, but we did not observe the species at any additional caves. At the three known sites with greatest abundance, visual counts per survey ranged 0–19 salamanders in 2017–2019. There was no apparent trend in abundance at Berry Cave. Visual counts declined 65% since the mid-2000s at Meads Quarry Cave and 80% since the early 1980s at Mudflats Cave. Mark-recapture studies in 160-m of cave stream at Berry Cave in 2017–2018 and 900-m of cave stream at Meads Quarry Cave in 2008 yielded population size estimates that ranged from 34–78 and 15–65 individuals, respectively. We identified 13 existing or potential threats to populations. Habitat degradation and groundwater contamination (associated with urbanization of the Knoxville metropolitan area and past mining operations) represent the most evident threats to long-term viability. Based on our conservation assessments, we recommend a rank of Endangered under IUCN Red List criteria and Critically Imperiled–Imperiled (G1G2) under NatureServe criteria. In opposition to the recent U.S. Fish & Wildlife Service decision, we advocate that, at minimum, G. gulolineatus remain a Candidate Species. Given the identified threats and these ranks, we offer several recommendations for research, conservation, and management of this rare salamander.

59 BASIC BIOLOGICAL SCIENCES↗

Exploitation of a Validation Hierarchy for Modeling and Simulation

Across engineering there is an evolving need to increase reliance on physics-based simulation to develop, design and optimize engineering systems. This increased reliance on modeling and simulation has highlighted a growing need to transform the confidence that modeling and simulation analysts have in their results into credibility for systems engineers to design and field systems more quickly and with less physical testing. For isolated components of a complex system, where a single discipline may drive product design, this is less of a concern as the relationship is often straightforward and easy to explain. However, when these isolated components are integrated, and are expected to operate in a multi-disciplinary context in which safety critical systems are involved, new concepts and model assurance standards are required. In this paper we address this challenge by showing how a model validation hierarchy can be exploited to identify those model validation experiments that will contribute most to increasing confidence and credibility of modeling and simulation predictions. The approach that is adopted contains four main steps. The first step is the construction of a model validation hierarchy that links subsystems, assemblies, and components to a hierarchy of physical experiments that can be used support model validation. This hierarchy connects the concerns of systems engineers to those of the modeling and simulation analyst in a clear and logical way. The structure and content of this hierarchy is then used in a second step to establish which physical phenomena have the greatest impact on overall system performance metrics. A gap analysis technique, based upon modeling and simulation concerns, is then used to prioritize the important physical phenomenon. Unfortunately, a common outcome of such gap analyses is the identification of many important gaps and so, in the final step of our process, we advocate the use of a global sensitivity analysis as a means to complete the prioritization.

Verification and Validation↗

Exploitation of a Validation Hierarchy for Modeling and Simulation

Across engineering there is an evolving need to increase reliance on physics-based simulation to develop, design and optimize engineering systems. This increased reliance on modeling and simulation has highlighted a growing need to transform the confidence that modeling and simulation analysts have in their results into credibility for systems engineers to design and field systems more quickly and with less physical testing. For isolated components of a complex system, where a single discipline may drive product design, this is less of a concern as the relationship is often straightforward and easy to explain. However, when these isolated components are integrated, and are expected to operate in a multi-disciplinary context in which safety critical systems are involved, new concepts and model assurance standards are required. In this paper we address this challenge by showing how a model validation hierarchy can be exploited to identify those model validation experiments that will contribute most to increasing confidence and credibility of modeling and simulation predictions. The approach that is adopted contains four main steps. The first step is the construction of a model validation hierarchy that links subsystems, assemblies, and components to a hierarchy of physical experiments that can be used support model validation. This hierarchy connects the concerns of systems engineers to those of the modeling and simulation analyst in a clear and logical way. The structure and content of this hierarchy is then used in a second step to establish which physical phenomena have the greatest impact on overall system performance metrics. A gap analysis technique, based upon modeling and simulation concerns, is then used to prioritize the important physical phenomenon. Unfortunately, a common outcome of such gap analyses is the identification of many important gaps and so, in the final step of our process, we advocate the use of a global sensitivity analysis as a means to complete the prioritization.

Verification and Validation↗