Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation

The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imaging was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electron Beam Diagnostics using Coherent Cherenkov Radiation in Aerogel

The use of coherent Cherenkov radiation as a diagnostic tool for longitudinal distribution of an electron beam is studied in this paper. Coherent Cherenkov radiation is produced in an aerogel with an index of refraction close to unity. An aerogel spectral properties are experimentally studied and analyzed. This method will be employed for the helical IFEL bunching experiment at Neptune linear accelerator facility at UCLA.

43 PARTICLE ACCELERATORS↗

The cryomodule test stand at the European Spallation Source

The European Spallation Source (ESS) is an intergovernmental project building a multidisciplinary research laboratory based upon the world's most powerful neutron source to be built in Lund, Sweden. The ESS will use a linear accelerator which will deliver protons with 5 MW of power to the target at 2.5 GeV with a nominal current of 50 mA. The superconducting part of the linac consists of over 150 niobium cavities cooled with superfluid helium at 2 K. A dedicated cryoplant will supply the cryomodules with single phase helium through an external cryogenic transfer line. The elliptical cavity cryomodules will undergo their site acceptance tests at the ESS cryomodule test stand in Lund. This test stand will use a 4.5 K cryoplant and warm sub-atmospheric compression to supply the 2 K helium. We will show the requirements for the test stand, a layout proposal and discuss the factors determining the required cryogenic capacity, test sequence and schedule.

43 PARTICLE ACCELERATORS↗

LANSCE wire scanning diagnostics device mechanical design

The Los Alamos Neutron Science Center (LANSCE) is one of the major experimental science facilities at the Los Alamos National Laboratory (LANL). The core of LANSCE's work lies in the operation of a powerful linear accelerator, which accelerates protons up to 84% the speed oflight. These protons are used for a variety of purposes, including materials testing, weapons research and isotopes production. To assist in guiding the proton beam, a series of over one hundred wire scanners are used to measure the beam profile at various locations along the half-mile length of the particle accelerator. A wire scanner is an electro-mechanical device that moves a set of wires through a particle beam and measures the secondary emissions from the resulting beam-wire interaction to obtain beam intensity information. When supplemented with data from a position sensor, this information is used to determine the cross-sectional profile of the beam. This measurement allows beam operators to adjust parameters such as acceleration, beam steering, and focus to ensure that the beam reaches its destination as effectively as possible. Some of the current wire scanners are nearly forty years old and are becoming obsolete. The problem with current wire scanners comes in the difficulty of maintenance and reliability. The designs of these wire scanners vary making it difficult to keep spare parts that would work on all designs. Also many of the components are custom built or out-dated technology and are no longer in production.

43 PARTICLE ACCELERATORS↗

Broad-band chopper for a CW proton linac at Fermilab

The future Fermilab program in the high energy physics is based on a new facility called the Project X [1] to be built in the following decade. It is based on a 3 MW CW linear accelerator delivering the 3 GeV 1 mA H{sup -} beam to a few experiments simultaneously. Small fraction of this beam will be redirected for further acceleration to 8 GeV to be injected to the Recycler/Main Injector for a usage in a neutrino program and other synchrotron based high energy experiments. Requirements and technical limitations to the bunch-by-bunch chopper for the Fermilab Project X are discussed.

43 PARTICLE ACCELERATORS↗

Status of the Short-Pulse X-ray Project at the Advanced Photon Source

The Advanced Photon Source Upgrade (APS-U) Project at Argonne will include generation of short-pulse x-rays based on Zholents deflecting cavity scheme. We have chosen superconducting (SC) cavities in order to have a continuous train of crabbed bunches and flexibility of operating modes. In collaboration with Jefferson Laboratory, we are prototyping and testing a number of single-cell deflecting cavities and associated auxiliary systems with promising initial results. In collaboration with Lawrence Berkeley National Laboratory, we are working to develop state-of-the-art timing, synchronization, and differential rf phase stability systems that are required for SPX. Collaboration with Advanced Computations Department at Stanford Linear Accelerator Center is looking into simulations of complex, multi-cavity geometries with lower- and higher-order modes waveguide dampers using ACE3P. This contribution provides the current R&D status of the SPX project.

43 PARTICLE ACCELERATORS↗

Photoemission Study of Cs-NF3 Activated GaAs(100) Negative Electron Affinity Photocathodes

GaAs based negative electron affinity photocathodes activated with Cs and NF{sub 3} are used as polarized electron sources for linear accelerators. It is generally believed that the activation layer consists of CsF. The activation layers of Cs-NF{sub 3} on GaAs photocathodes are herein investigated using synchrotron radiation photoelectron spectroscopy (SR-PES). F1s, N1s and other core levels are recorded at photon energies ranging from 70eV to 820eV. Surprisingly, a significant amount of nitrogen is observed in the activation layers. Two distinct species of nitrogen are observed, one of which decreases along with the Fluorine signal as the yield of the photocathode decays with time.

43 PARTICLE ACCELERATORS↗

Radiological Studies for the LCLS Beam Abort System

The Linac Coherent Light Source (LCLS), a pioneer hard x-ray free electron laser is currently under construction at the Stanford Linear Accelerator Center. It is expected that by 2009 LCLS will deliver laser pulses of unprecedented brightness and short length, which will be used in several forefront research applications. This ambitious project encompasses major design challenges to the radiation protection like the numerous sources and the number of surveyed objects. In order to sort those, the showers from various loss sources have been tracked along a detailed model covering 1/2 mile of LCLS accelerator by means of the Monte Carlo intra nuclear cascade codes FLUKA and MARS15. This article covers the FLUKA studies of heat load; prompt and residual dose and environmental impact for the LCLS beam abort system.

43 PARTICLE ACCELERATORS↗

Review of Activities using the Pulsed Neutron Facility and 2.5-GeV Electron Linac at Pohang Accelerator Laboratory

We report on activities using a pulsed neutron facility consisting of an electron linear accelerator, a water-cooled Ta target with a water moderator, and a 12 m time-of-flight path. It is possible to measure neutron total cross sections in the neutron energy range from 0.01 eV to a few hundred eV by using the neutron time-of-flight method; photo-neutron cross sections can also measure by using the bremsstrahlung from the electron linac. A {sup 6}LiZnS(Ag) glass scintillator was used as a neutron detector. The neutron flight path from the water-cooled Ta target to the neutron detector was 12.1 m. In this paper, we report total cross sections of Nb and also resonance parameters obtained using the SAMMY fitting program. The present results are compared with the previous experimental results and the evaluated data in ENDF/B-VII. We also report on the mass-yield distribution of fission products in the 2.5-GeV bremsstrahlung-induced fission of {sup nat}Pb and {sup 209}Bi measured at the 2.5-GeV electron linac using a recoil catcher and an off-line {gamma}-ray spectrometric technique.

43 PARTICLE ACCELERATORS↗

Brightness enhancement method for a high-intensity positron beam produced by an electron accelerator

A method for enhancing the brightness of an intense slow positron beam produced by an electron linear accelerator (LINAC) in order to obtain an intense positron microbeam was developed. The developed brightness enhancement system is simple and consists only of a few beam optics and a transmission remoderator. The slow positron beam produced by the LINAC is magnetically guided from the positron source to an experimental room. The beam is extracted from the magnetic field and is focused by a lens on the remoderator to enhance its brightness. The brightness-enhanced beam is extracted from the remoderator and focused on a sample by a lens. The beam size at the sample was 90 {mu}m, which was two orders of magnitude smaller than that in the magnetic transport system that was about 10 mm. The efficiency of the transmission remoderator was about 5%. Adiabatic rules in the magnetic transport and the paraxial-ray equation were used to estimate the beam size that could be produced using this method.

43 PARTICLE ACCELERATORS↗

Radiation Protection Studies for LCLS Tune Up Dump

The Linac Coherent Light Source (LCLS) at the Stanford Linear Accelerator Center is a pioneer fourth generation hard x-ray free electron laser that shall start to deliver laser pulses in 2009. Among other components of LCLS that present radiation protection concerns, the tune up dump (tdund) is of special interest because it also constitutes an issue for machine protection, as it is placed close to radiation sensitive components, like electronic devices and permanent magnets in the undulators. This paper first introduces the stopper of tdund looking at the heat load, and then it describes the shielding around the dump necessary to maintain the prompt and residual dose within design values. Next, preliminary comparisons of the magnetization loss in a dedicated on-site magnet irradiation experiment with FLUKA simulations serve to characterize the magnetic response to radiation of magnets like those of LCLS. The previous knowledge, together with the limit for the allowed demagnetization, are used to estimate the lifetime of the undulator. Further simulations provide guidelines on which lifetime can be expected for an electronic device placed at a given distance of tdund.

43 PARTICLE ACCELERATORS↗

New Improved Nuclear Data for Nuclear Criticality and Safety

The Geel Electron Linear Accelerator (GELINA) was used to measure neutron total and capture cross sections of 182,183,184,186 W and 63,65 Cu in the energy range from 100 eV to {approx}200 keV using the time-of-flight method. GELINA is the only high-power white neutron source with excellent timing resolution and ideally suited for these experiments. Concerns about the use of existing cross-section data in nuclear criticality calculations using Monte Carlo codes and benchmarks were a prime motivator for the new cross-section measurements. To support the Nuclear Criticality Safety Program, neutron cross-section measurements were initiated using GELINA at the EC-JRC-IRMM. Concerns about data deficiencies in some existing cross-section evaluations from libraries such as ENDF/B, JEFF, or JENDL for nuclear criticality calculations were the prime motivator for new cross-section measurements. Over the past years many troubles with existing nuclear data have emerged, such as problems related to proper normalization, neutron sensitivity backgrounds, poorly characterized samples, and use of improper pulse-height weighting functions. These deficiencies may occur in the resolved- and unresolved-resonance region and may lead to erroneous nuclear criticality calculations. An example is the use of the evaluated neutron cross-section data for tungsten in nuclear criticality safety calculations, which exhibit discrepancies in benchmark calculations and show the need for reliable covariance data. We measured the neutron total and capture cross sections of 182,183,184,186 W and 63,65 Cu in the neutron energy range from 100 eV to several hundred keV. This will help to improve the representation of the cross sections since most of the available evaluated data rely only on old measurements. Usually, these measurements were done with poor experimental resolution or only over a very limited energy range, which is insufficient for the current application.

43 PARTICLE ACCELERATORS↗

Results of the Energy Doubler Experiment at SLAC

The costs and the time scales of colliders intended to reach the energy frontier are such that it is important to explore new methods of accelerating particles to high energies. Plasma-based accelerators are particularly attractive because they are capable of producing accelerating fields that are orders of magnitude larger than those used in conventional colliders. In these accelerators a drive beam, either laser or particle, produces a plasma wave (wakefield) that accelerates charged particles. The ultimate utility of plasma accelerators will depend on sustaining ultra-high accelerating fields over a substantial length to achieve a significant energy gain. More than 42 GeV energy gain was achieved in an 85 cm long plasma wakefield accelerator driven by a 42 GeV electron drive beam at the Stanford Linear Accelerator Center (SLAC). Most of the beam electrons lose energy to the plasma wave, but some electrons in the back of the same beam pulse are accelerated with a field of {approx}52 GV/m. This effectively doubles their energy, producing the energy gain of the 3 km long SLAC accelerator in less than a metre for a small fraction of the electrons in the injected bunch.

43 PARTICLE ACCELERATORS↗

Vibrational measurement for commissioning SRF Accelerator Test Facility at Fermilab

The commissioning of two cryomodule components is underway at Fermilab's Superconducting Radio Frequency (SRF) Accelerator Test Facility. The research at this facility supports the next generation high intensity linear accelerators such as the International Linear Collider (ILC), a new high intensity injector (Project X) and other future machines. These components, Cryomodule No.1 (CM1) and Capture Cavity II (CC2), which contain 1.3 GHz cavities are connected in series in the beamline and through cryogenic plumbing. Studies regarding characterization of ground motion, technical and cultural noise continue. Mechanical transfer functions between the foundation and critical beamline components have been measured and overall system displacement characterized. Baseline motion measurements given initial operation of cryogenic, vacuum systems and other utilities are considered.

43 PARTICLE ACCELERATORS↗

A New Green's Function for the Wake Potential Calculation of the SLAC S-band Constant Gradient Accelerating Section

The behavior of the longitudinal wake fields excited by a very short bunch in the SLAC S-band constant gradient accelerating structures has been studied. Wake potential calculations were performed for a bunch length of 10 microns using the author's code to obtain a numerical solution of Maxwell's equations in the time domain. We have calculated six accelerating sections in the series (60-ft) to find the stationary solution. While analyzing the computational results we have found a new formula for the Green's function. Wake potentials, which are calculated using this Green's function are in amazingly good agreement with numerical results over a wide range of bunch lengths. The Green's function simplifies the wake potential calculations and can be easily incorporated into the tracking codes. This is very useful for beam dynamics studies of the linear accelerators of LCLS and FACET.

43 PARTICLE ACCELERATORS↗

Recent Upgrade of the Klystron Modulator at SLAC

The SLAC National Accelerator Laboratory employs 244 klystron modulators on its two-mile-long linear accelerator that has been operational since the early days of the SLAC establishment in the sixties. Each of these original modulators was designed to provide 250 kV, 262 A and 3.5 {mu}S at up to 360 pps using an inductance-capacitance resonant charging system, a modified type-E pulse-forming network (PFN), and a pulse transformer. The modulator internal control comprised of large step-start resistor-contactors, vacuum-tube amplifiers, and 120 Vac relays for logical signals. A major, power-component-only upgrade, which began in 1983 to accommodate the required beam energy of the SLAC Linear Collider (SLC) project, raised the modulator peak output capacity to 360 kV, 420 A and 5.0 {mu}S at a reduced pulse repetition rate of 120 pps. In an effort to improve safety, performance, reliability and maintainability of the modulator, this recent upgrade focuses on the remaining three-phase AC power input and modulator controls. The upgrade includes the utilization of primary SCR phase control rectifiers, integrated fault protection and voltage regulation circuitries, and programmable logic controllers (PLC) -- with an emphasis on component physical layouts for safety and maintainability concerns. In this paper, we will describe the design and implementation of each upgraded component in the modulator control system. We will also report the testing and present status of the modified modulators.

43 PARTICLE ACCELERATORS↗

Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy

Purpose: The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. Methods: The device used in this study was Octavius 1000 SRS model (PTW, Freiburg, Germany). Its 2D array of detectors consists of 977 liquid-filled ion chambers arranged over an area of 11 × 11 cm. The size of the detectors is 2.3 × 2.3 × 0.5 mm (volume of 0.003 cm{sup 3}) and their spacing in the inner area of 5.5 × 5.5 cm is 2.5 mm center-to-center, whereas in the outer area it is 5 mm center-to-center. The detector reproducibility, dose linearity, and sensitivity to positional changes of the collimator were tested. Also, the output factors of field sizes ranging from 0.5 × 0.5 to 10 × 10 cm{sup 2} both for open and wedged fields have been measured and compared against those measured by a pin-point ionization chamber, liquid filled microchamber, SRS diode, and EDR2 film. Results: Its short-term reproducibility was within 0.2% and its medium and long-term reproducibility was within 0.5% (verified with air ionization chamber absolute dose measurements), which is an excellent result taking into account the daily fluctuation of the linear accelerator and the errors in the device setup reproducibility. The dose linearity and dose rate dependence were measured in the range of 0.5–85 Gy and 0.5–10 Gy min{sup −1}, respectively, and were verified with air ionization chamber absolute dose measurements was within 3%. The measurements of the sensitivity showed that the 2D Array could detect millimetric collimator positional changes. The measured output factors showed an agreement of better than 0.3% with the pinpoint chamber and microliquid filled chamber for the field sizes between 3 × 3 and 10 × 10 cm{sup 2}. For field sizes down to 1 × 1 cm{sup 2}, the agreement with SRS diode and microliquid filled chamber is better than 2%. The measurements of open and wedge-modulated field profiles were compared to the film and ionization chamber in water measurements. Conclusions: The Octavius Detector 1000 SRS is an accurate, precise, and reliable detector, very useful for the daily performance of the patient specific quality assurance of radiotherapy treatment plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo simulations of photoneutron activation in a medical LINAC

The first step of the present study was to simulate the γ-radioactivity produced by photoneutrons in the treatment head of a decommissioned medical LINAC. These results, obtained with MCNPX and CINDER'90, are then compared with γ-ray spectrometric measurements of parts of the treatment head. Our ultimate objective is to simulate the associated production by photonuclear reactions of pure β-emitters, which are more difficult to access experimentally than the γ-ray emitters. (authors)

43 PARTICLE ACCELERATORS↗