Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Finite Element Simulation of Mixed-Mode PV Encapsulant Delamination Based on Cohesive Zone Model: Preprint

A finite element model (FEM) was developed to simulate the mixed-mode delamination failure at the encapsulant interface within PV modules under mixed-mode loading condi- tions. Parameters to characterize the bilinear traction-separation constitutive behavior of cohesive elements were determined by testing the pure mode I critical fracture energy of the photovotaic(PV) cell interface using the width-tapered beam and fitting the simulated load-displacement curve with the tested curve. This developed FEM can be used to predict the critical temperature changes, at which delamination would initiate, of PV modules with different sizes and provide guidance for the design of PV module with better reliability.

97 MATHEMATICS AND COMPUTING↗

Validation of Simulated Wave Energy Converter Responses to Focused Waves for CCP-WSI Blind Test Series 2: Preprint

Increasingly, focused waves are used as a design method to predict extreme loads for offshore structures, such as wave energy converters (WECs). However, the ability of computational methods to accurately simulate the prescribed focused waves and resulting wave structure interactions are not well-validated. As a participant in the Collaborative Computational Project in Wave Structure Interaction Blind Test Series 2, this study uses two computational fluid dynamics methods, WEC-Sim and STAR-CCM+, to evaluate three focused waves on two WEC-like bodies. WEC-Sim is a computationally efficient, midfidelity model based on linearized potential flow theory. STAR-CCM+ is a high-fidelity, three-dimensional, unsteady, Reynolds-averaged Navier-Stokes-based model. The two geometries considered are a hemispherical buoy and a cylindrical moon pool. The experimentally measured focused waves are reproduced in both codes, and the simulated displacements and mooring loads are obtained for each of the hydrodynamic bodies. The resulting STAR-CCM+ generated focused waves have approximately the same accuracy, in comparison to the analytic solution, as the experimentally generated focused waves. And, the WEC-Sim and STAR-CCM+ simulated displacements and mooring loads are, on average, within 5% of each other.

16 TIDAL AND WAVE POWER↗

Modeling of fracture of protective concrete structures under impact loads

This paper presents results of numerical simulation of interaction between a Boeing 747-400 aircraft and the protective shell of a nuclear power plant. The shell is presented as a complex multilayered cellular structure consisting of layers of concrete and fiber concrete bonded with steel trusses. Numerical simulation was performed three-dimensionally using the original algorithm and software taking into account algorithms for building grids of complex geometric objects and parallel computations. Dynamics of the stress-strain state and fracture of the structure were studied. Destruction is described using a two-stage model that allows taking into account anisotropy of elastic and strength properties of concrete and fiber concrete. It is shown that wave processes initiate destruction of the cellular shell structure; cells start to destruct in an unloading wave originating after the compression wave arrival at free cell surfaces.

36 MATERIALS SCIENCE↗

Breakdown of adiabaticity when loading ultracold atoms in optical lattices

Realistic simulations of current ultracold atom experiments in optical lattices show that the ramping up of the optical lattice is significantly nonadiabatic, implying that experimentally prepared Mott insulators are not really in the ground state of the atomic system. The nonadiabaticity is even larger in the presence of a secondary quasiperiodic lattice simulating 'disorder'. Alternative ramping schemes are suggested that improve the adiabaticity when the disorder is not too large.

74 ATOMIC AND MOLECULAR PHYSICS↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Formation of Multilayer Graphene Domains with Strong Sulfur-Carbon Interaction and Enhanced Sulfur Reduction Zones for Lithium-Sulfur Battery Cathodes

A newly designed sulfur/graphene computational model emulates the electrochemical behavior of a Li–S battery cathode, promoting the S–C interaction through the edges of graphene sheets. A random mixture of eight-membered sulfur rings mixed with small graphene sheets is simulated at 64 wt%sulfur loading. Structural stabilization and sulfur reduction calculations are performed with classical reactive molecular dynamics. This methodology allowed the collective behavior of the sulfur and graphene structures to be accounted for. The sulfur encapsulation induces ring opening and the sulfur phase evolves into a distribution of small chain-like structures interacting with C through the graphene edges. This new arrangement of the sulfur phase not only leads to a less pronounced volume expansion during sulfur reduction but also to a different discharge voltage profile, in qualitative agreement with earlier reports on sulfur encapsulation in microporous carbon structures. The Li 2 S phase grows around ensembles of parallel graphene nanosheets during sulfur reduction. No diffusion of sulfur or lithium between graphene nanosheets is observed, and extended Li 2 S domains bridging the space between carbon ensembles are suppressed. The results emphasize the importance of morphology on the electrochemical performance of the composite material. Finally, the sulfur/graphene model outlined here provides new understanding of the graphene effects on the sulfur reduction behavior and the role that van der Waals interactions may play in promoting formation of multilayer graphene ensembles and small Li 2 S domains during sulfur reduction.

25 ENERGY STORAGE↗

Database for Validation of Design Load Extrapolation Techniques

Extrapolation techniques used for predicting long-term wind turbine loads have produced highly variable loading estimates dependent on the individual designer implementation. To reduce such variability, more precise definition and validation of these techniques are necessary. As part of a wider effort to test loads extrapolation techniques used in wind turbine design, two data sets were created. The first data set was created as an example typical of what designers use to extrapolate loads according to wind turbine design standards. The second data set was a series of year-long simulations that could be used to quantify the accuracy of extrapolation methods. Due to the large number of simulations, care was taken not to reproduce random samplings in individual time series. Additionally, a grid computing architecture was used to run the simulations in a reasonable time frame. The wind speeds where loads were highest were identified, which varied with loading type. The identification of dominant wind speeds is important to ensure an adequate number of simulations at such speeds, which often influence extrapolated loads. In-plane loads and deflections tended to be dominated by high wind speeds near cut-out wind speed. Out-of-plane loads and deflections were most influenced by winds that were near the rated wind speed. Some loads were influenced by a range of wind speeds. The loads dominated by high wind speeds had greater variability in the extreme values, which could be a reflection of the greatly varying wind and also greater sensitivity to higher energy content of the wind at such speeds.

17 WIND ENERGY↗

CO 2 adsorption-induced structural changes in coordination polymer ligands elucidated via molecular simulations and experiments

Aiming to elucidate guest-induced structural changes in the coordination polymer CPL-2, grand canonical Monte Carlo (GCMC) simulations were used to predict CO 2 loadings in this material, and the results were compared with experimental isotherms. Our calculations suggest that CPL-2 exhibits more pronounced CO 2 -induced structural changes than previously reported. As the initial evidence, the isotherm simulated in the previously reported CPL-2 structure (experimentally resolved from X-ray diffraction in the “as-synthesized” CPL-2) underestimated the measured CO 2 loadings at high pressure, indicating that CPL-2 might undergo structural changes that enable higher pore volumes at high pressure. GCMC simulations in CPL-2 structures considering moderate unit cell expansions reported in the literature still underestimated high-pressure experimental loadings. However, considering an incremental rotation of the CPL-2 bipyridyl pillars with increasing CO 2 pressure, we were able to trace the measured isotherm with the simulation data. Computational analysis shows that ligand rotation in CPL-2 enables higher pore volumes, which, in turn, accommodate more CO 2 as the gas pressure increases. Desorption measurements suggest that hysteresis in the CO 2 isotherm of CPL-2 may also be linked to ligand rotation, and the measured adsorption/desorption cycles show that the rotation is reversible. Based on our simulations for CPL-4 and CPL-5 and previously reported experimental data, it is likely that these materials, which differ from CPL-2 in the bipyridyl ligand, behave similarly in the presence of CO 2 . Our results help understand the behavior of these materials, which present the kind of structural changes that could be potentially exploited to enhance the CO 2 working capacity of ultra-microporous materials for carbon capture applications.

Meza-Morales, Paul J.↗

Grid-Supportive Loads - A New Approach to Increasing Renewable Energy in Power Systems

This paper demonstrates the potential of inverter-based loads to support grid reliability during power system transients thereby enabling reliable integration of renewable energy in power systems. Such loads are referred to in this paper as grid-supportive loads (GSLs). A new GSL model is developed that simulates the transient response capabilities that can be programmed in electronic loads. The model’s design enables it to be easily integrated in widely used commercial power system transient analysis software. Theoretical expressions are derived that explain the workings of the GSL model. The performance, numerical stability, and impact of the GSL model is validated on 9-bus and 2000-bus synthetic power system models using generator tripping and bus fault disturbances. Results on the 2000 bus system show that in the absence of frequency support from wind/solar generation resources, just 20% of loads with grid-supportive capabilities can improve frequency response by up to 2000 MW/0.1 Hz and reduce deviation in frequency at nadir by up to 60% compared to the situation when GSLs are absent. Power system reliability also improves under fault events. Here, it is further shown that GSLs can aid in integrating more renewable generation without degrading the overall transient response of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Moisture Effects on Compaction of Fiberboard in a 9975 Shipping Package (Final Report)

Compaction of lower layers in the fiberboard assembly has been observed in 9975 packages that contain elevated moisture. Lab testing has resulted in a better understanding of the relationship between the fiberboard moisture level and compaction of the lower fiberboard assembly, and the behavior of the fiberboard during transport. In laboratory tests of cane fiberboard, higher moisture content has been shown to correspond to higher total compaction, greater rate of compaction, and continued compaction over a longer period of time. In addition, laboratory tests have shown that the application of a dynamic load results in higher fiberboard compaction compared to a static load. The test conditions and sample geometric/loading configurations were chosen to simulate the regulatory requirements for 9975 package input dynamic loading. Dynamic testing was conducted to acquire immediate and cumulative changes in geometric data for various moisture levels. Two sample sets have undergone a complete dynamic test regimen, one set for 27 weeks, and the second set for 47 weeks. The dynamic input, data acquisition, test effects on sample dynamic parameters, and results from this test program are summarized and compared to regulatory specifications for dynamic loading. Compaction of the bottom fiberboard layers due to the accumulation of moisture is one possible cause of an increase in the axial gap at the top of the package. The net compaction of the bottom layers will directly add to the axial gap. The moisture which caused this compaction migrated from the middle region of the fiberboard assembly (which is typically the hottest). This will cause the middle region to shrink axially, which will also contribute directly to the axial gap. Measurement of the axial gap provides a screening tool for identifying significant change in the fiberboard condition. The data in this report provide a basis to evaluate the impact of moisture and fiberboard compaction on 9975 package performance during storage at the Savannah River Site (SRS).

36 MATERIALS SCIENCE↗

Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in hot and humid climate

This paper presents a detailed analysis of the energy and economic performance of desiccant cooling systems (DEC) equipped with both single glazed standard air and hybrid photovoltaic/thermal (PV/t) collectors for applications in hot and humid climates. The use of 'solar cogeneration' by means of PV/t hybrid collectors enables the simultaneous production of electricity and heat, which can be directly used by desiccant air handling units, thereby making it possible to achieve very energy savings. The present work shows the results of detailed simulations conducted for a set of desiccant cooling systems operating without any heat storage. System performance was investigated through hourly simulations for different systems and load combinations. Three configurations of DEC systems were considered: standard DEC, DEC with an integrated heat pump and DEC with an enthalpy wheel. Two kinds of building occupations were considered: office and lecture room. Moreover, three configurations of solar-assisted air handling units (AHU) equipped with desiccant wheels were considered and compared with standard AHUs, focusing on achievable primary energy savings. The relationship between the solar collector's area and the specific primary energy consumption for different system configurations and building occupation patterns is described. For both occupation patterns, sensitivity analysis on system performance was performed for different solar collector areas. Also, this work presents an economic assessment of the systems. The cost of conserved energy and the payback time were calculated, with and without public incentives for solar cooling systems. It is worth noting that the use of photovoltaics, and thus the exploitation of related available incentives in many European countries, could positively influence the spread of solar air cooling technologies (SAC). An outcome of this work is that SAC systems equipped with PV/t collectors are shown to have better performance in terms of primary energy saving than conventional systems fed by vapour compression chillers and coupled with PV cells. All SAC systems present good figures for primary energy consumption. The best performances are seen in systems with integrated heat pumps and small solar collector areas. The economics of these SAC systems at current equipment costs and energy prices are acceptable. They become more interesting in the case of public incentives of up to 30% of the investment cost (Simple Payback Time from 5 to 10 years) and doubled energy prices. (author)

14 SOLAR ENERGY↗

Approximating a linear multiplicative objective in watershed management optimization

Implementing management practices in a cost-efficient manner is critical for regional efforts to reduce the amount of pollutants entering the Chesapeake Bay. We study the problem of selecting a subset of practices that minimizes pollutant load—subject to budgetary and environmental constraints—as simulated in a widely used regulatory watershed model. Mimicking the computation of pollutant load in the regulatory model, we formulate this problem as a continuous optimization model with a linear multiplicative objective function and linear constraints. To lay the groundwork for incorporating additional stakeholder requirements in the future, especially those that would require integer variables, we present and study a continuous linear optimization model that approximates the nonlinear model. The linear model, which requires an exponential number of variables, arises naturally as an alternative model for the same underlying physical process. We examine the theoretical behavior of these optimization models and investigate restrictions of the linear model to handle its large number of variables. Through extensive computational tests on real and randomly generated instances, we demonstrate that the linear model and its restrictions provide optimal solutions close to those of the nonlinear model in practice, despite poor approximation properties in the worst case. We conclude that the linear model—together with our approach to handling its large number of variables—provides a viable framework from which to extend the optimization model to better meet the needs of the Chesapeake Bay watershed management stakeholders.

54 ENVIRONMENTAL SCIENCES↗

Data-Driven Probabilistic Anomaly Detection for Electricity Market under Cyber Attacks

Information and communication technologies have been widely used in smart grid for efficient operation. However, these technologies are vulnerable to malicious cyber attacks, which may lead to severe reliability and economic issues. Recently, a variety of data-driven anomaly detection approaches have been explored to detect potential cyber attacks in smart grids. In this paper, we researched on the electricity market data aiming to identify anomalies from the locational marginal prices (LMPs) and provide a new indicator for potential cyber attacks in power grids. Specifically, a novel data-driven probabilistic anomaly detection framework is proposed for electricity market, which consists of three major components: long short-term memory (LSTM) based deterministic electricity price forecasting, probabilistic electricity price forecasting and anomaly detection. This framework is tested on a model-based electricity market simulator under two types of cyber attacks, i.e., load redistribution attack (LRA) and price responsive attack (PRA). Numerical results on the simulated LMPs show that the proposed framework is capable of detecting data anomalies over these attacks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sensitivity Analysis of Tunable Equation of State Material Model In Pulsed Mercury Target Simulation

A pulsed neutron spallation target is subjected to very short but intense loads from repeated proton pulses. Approximately 60% of the energy from each proton pulse is deposited into the mercury target material and the stainless-steel target structure, leading to a high-pressure region in both the stationary target structure and the flowing mercury. The high-pressure region propagates and leads to fluid-structure interaction. The resultant loading on the target structure containing liquid mercury is difficult to predict, although various simulation approaches and material models for the mercury have been tried. To date, the best match of simulation to experimental data is obtained by using an equation of state (EOS) material model with a specified tensile cutoff pressure, which simulates the cavitation threshold. The inclusion of a threshold to represent cavitation is key to the successful predictions of stress waves triggered by the high-energy pulse striking the mercury and vessel. However, recent measurements of target structure strain show that significant discrepancies remain between the measured and simulated strain values in the EOS mercury model. These differences grow when noncondensable helium gas is intentionally injected into the flowing mercury to reduce the loading on the structure. An EOS-based proportional–integral–derivative (PID) mercury model has been proposed to reduce the gap between the measured and simulated vessel strain responses for targets with gas injection. The conceptual and numerical description and initial investigation of the PID model are presented in previous work. Further studies of this PID model — including the sensitivity of the structure’s strain response to model parameters (the tensile cutoff, PID parameters Kp, Ki, and Kd) — are reported in this article. Results show the strain response is more sensitive to changes in the tensile cutoff value than to changes in the model parameters Kp, Ki, and Kd. These results will aid in future work where the model parameters will be optimized to match simulation data to strain measurements.

Lin, Lianshan↗

ResStock: Annual Baseline Results with Component Loads

The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and high-performance computing. This combination achieves unprecedented granularity and accuracy in modeling the diversity of the housing stock and the distributional impacts of building technologies in different communities. The annual baseline energy results from a national-scale ResStock run use typical meteorological year 3 (TMY3) files for energy simulations. Results include heating and cooling loads for individual components of each building. Component loads describe the heating/cooling load that can be attributed to specific elements of a home, such as heat transfer through walls or internal gains. Additionally, these results include the standard ResStock outputs for housing characteristics and numerous energy outputs by end-use and fuel. A snapshot of the ResStock version used to produce this data, including a configuration file for the run can be found using the Source Code resource link.

Array↗

Understanding the plasticity contributions during laser-shock loading and spall failure of Cu microstructures at the atomic scales

A hybrid atomic-scale and continuum modeling framework is used to study the microstructural evolution during the laser-induced shock deformation and failure (spallation) of copper microstructures. A continuum two-temperature model (TTM) is used to account for the interaction of Cu atoms with a laser in molecular dynamics (MD) simulations. The MD-TTM simulations study the effect of laser loading conditions (laser fluence) on the microstructure (defects) evolution during various stages of shock wave propagation, reflection, and interaction in single-crystal (sc) Cu systems. In addition, the role of the microstructure is investigated by comparing the defect evolution and spall response of sc-Cu and nanocrystalline (nc) Cu systems. The defect (stacking faults and twin faults) evolution behavior in the metal at various times is further characterized using virtual in situ selected area electron diffraction and x-ray diffraction during various stages of evolution of microstructure. Here, the simulations elucidate the uncertain relation between spall strength and strain-rate and the much stronger relation between the spall strength and the temperatures generated due to laser shock loading for the small Cu sample dimensions considered here.

36 MATERIALS SCIENCE↗

GLASS FORMULATION DEVELOPMENT AND TESTING FOR COLD CRUCIBLE INDUCTION MELTER (CCIM) ADVANCED REMEDIATION TECHNOLOGIES DEMONSTRATION PROJECT - 9208

Over the past few years, Cold Crucible Induction Melter (CCIM) demonstrations have been completed using SRS sludge batches 2, 3 and 4 (SB2, SB3 and SB4) simulant compositions. These campaigns demonstrated the ability of the CCIM to effectively produce quality glasses at high waste loadings. The current Advanced Remediation Technology (ART) Phase II-A Project is aimed at demonstrating the CCIM technology under representative DWPF flowsheet conditions and to demonstrate extended operations of the melter. A glass composition development effort was completed to identify and recommend a frit composition and sludge batch 4 (SB4) simulant waste loading target for subsequent ART-Phase II-A CCIM demonstration testing. Based on the results of the glass formulation testing, it was recommended that the Frit 503-R6 composition (B{sub 2}O{sub 3} = 14 wt %; Li{sub 2}O = 9 wt %; Na{sub 2}O = 3 wt %; and SiO{sub 2} = 74 wt %) be utilized for the demonstration. Furthermore, a waste loading of 46 wt % was recommended. The recommended frit and waste loading would produce a glass with acceptable durability with a liquidus temperature adequately below the 1250 C nominal CCIM operating temperature. This frit composition and waste loading was found to result in a glass that met CCIM processing requirements for viscosity, electrical conductivity and thermal conductivity. The recommended frit and waste loading level should also provide a buffer for sludge product compositional variation to support the Phase II-A CCIM demonstration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗