Search NASA⌕ Search

SEARCH · Search NASA

Results for “meshing complexity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Optimal control model of technology transition.

This paper discusses the use of optimization software to solve an optimal control problem arising in the modeling of technology transition. We set up a series of increasingly complex models with such features as learning-by-doing, adjustment cost, and capital investment. The models are written in continuous time and then discretized by using different methods to transform them into large-scale nonlinear programs. We use a modeling language and numerical optimization methods to solve the optimization problem. Our results are consistent with findings in the literature and highlight the impact the discretization choice has on the solution and accuracy. The primary goal of this paper is to develop solution methods for use in policy work. To do this, we will need to expand the model to include realistic features such as additional technologies and capital conversion. Our modeling approach allows us to add new technologies with minimal effort. For example, Figure 5 presents the solution to the capital model that includes a third technology, say, nuclear fusion, that is emission free but even more expensive (A{sub 3} > A{sub n}). We observe that industry first transitions to the intermediate technology but eventually adopts the cleanest one. We note that our solutions have few areas of large curvature and are relatively smooth elsewhere. On such smooth segments, we can achieve adequate precision with relatively large periods, which means fewer variables and increased computation speed. But we still need a small step length during the transition period. Adaptive mesh refinement methods have been developed to automatically identify the areas where extra precision is needed. Betts (2001) describes how the computation time can be reduced by a factor of 2.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Hydrostratigraphic System for Modeling Groundwater Flow and Radionuclide Migration at the Corrective Action Unit Scale, Nevada Test Site and Surrounding Areas, Clark, Lincoln, and Nye Counties, Nevada

Underground Test Area (UGTA) corrective action unit (CAU) groundwater flow and contaminant transport models of the Nevada Test Site (NTS) and vicinity are built upon hydrostratigraphic framework models (HFMs) that utilize the hydrostratigraphic unit (HSU) as the fundamental modeling component. The delineation and three-dimensional (3-D) modeling of HSUs within the highly complex geologic terrain that is the NTS requires a hydrostratigraphic system that is internally consistent, yet flexible enough to account for overlapping model areas, varied geologic terrain, and the development of multiple alternative HFMs. The UGTA CAU-scale hydrostratigraphic system builds on more than 50 years of geologic and hydrologic work in the NTS region. It includes 76 HSUs developed from nearly 300 stratigraphic units that span more than 570 million years of geologic time, and includes rock units as diverse as marine carbonate and siliciclastic rocks, granitic intrusives, rhyolitic lavas and ash-flow tuffs, and alluvial valley-fill deposits. The UGTA CAU-scale hydrostratigraphic system uses a geology-based approach and two-level classification scheme. The first, or lowest, level of the hydrostratigraphic system is the hydrogeologic unit (HGU). Rocks in a model area are first classified as one of ten HGUs based on the rock’s ability to transmit groundwater (i.e., nature of their porosity and permeability), which at the NTS is mainly a function of the rock’s primary lithology, type and degree of postdepositional alteration, and propensity to fracture. The second, or highest, level within the UGTA CAU-scale hydrostratigraphic system is the HSU, which is the fundamental mapping/modeling unit within UGTA CAU-scale HFMs. HSUs are 3-D bodies that are represented in the finite element mesh for the UGTA groundwater modeling process. HSUs are defined systematically by stratigraphically organizing HGUs of similar character into larger HSUs designations. The careful integration of stratigraphic information in the development of HSUs is important to assure individual HSUs are internally consistent, correlatable, and mappable throughout all the model areas.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The new barium zinc mercurides Ba{sub 3}ZnHg{sub 10} and BaZn{sub 0.6}Hg{sub 3.4} - Synthesis, crystal and electronic structure

The title compounds Ba{sub 3}ZnHg{sub 10} and BaZn{sub 0.6}Hg{sub 3.4} were synthesized from stoichiometric ratios of the elements in Ta crucibles. Their crystal structures, which both represent new structure types, have been determined using single crystal X-ray data. The structure of Ba{sub 3}ZnHg{sub 10} (orthorhombic, oP28, space group Pmmn, a=701.2(3), b=1706.9(8), c=627.3(3)pm, Z=2, R1=0.0657) contains folded 4{sup 4} Hg nets, where the meshes form the bases of flat rectangular pyramids resembling the structure of BaAl{sub 4}. The flat pyramids are connected via Hg-Zn/Hg bonds, leaving large channels at the folds, in which Ba(1) and Hg(2) atoms alternate. Whereas the remaining Hg/Zn atoms form a covalent 3D network of three- to five-bonded atoms with short M-M distances (273-301 pm; CN 9-11), the Hg(2) atoms in the channels adopt a comparatively large coordination number of 12 and increased distances (317-348 pm) to their Zn/Hg neighbours. In the structure of BaZn{sub 0.6}Hg{sub 3.4} (cubic, cI320, space group I4{sup Macron }3d, a=2025.50(7) pm, Z=64, R1=0.0440), with a chemical composition not much different from that of Ba{sub 3}ZnHg{sub 10}, the Zn/Hg atoms of the mixed positions M(1/2) are arranged in an slightly distorted primitive cubic lattice with a 4 Multiplication-Sign 4 Multiplication-Sign 4 subcell relation to the unit cell. The 24 of the originating 64 cubes contain planar cis tetramers Hg(5,6){sub 4} with Hg in a nearly trigonal planar or tetrahedral coordination. In another 24 of the small cubes, two opposing faces are decorated by Hg(3,4){sub 2} dumbbells, two by Ba(2) atoms respectively. The third type of small cubes are centered by Ba(1) atoms only. The complex 3D polyanionic Hg/Zn network thus formed is compared with the Hg partial structure in Rb{sub 3}Hg{sub 20} applying a group-subgroup relation. Despite their different overall structures, the connectivity of the negatively charged Hg atoms, the rather metallic Zn bonding characteristic (as obtained from FP-LAPW band structure calculations) and the coordination number of 16 for all Ba cations relate the two title compounds. - Graphical abstract: Six of the 64 small sub-cubes of three types (A, B, C) forming the unit cell of the Hg-rich mercuride BaZn{sub 0.6}Hg{sub 3.4}. Highlights: Black-Right-Pointing-Pointer Two new Hg-rich Ba mercurides, both synthesized from the elements in pure phase. Black-Right-Pointing-Pointer BaZn{sub 0.6}HgG{sub 3.4} and Ba{sub 3}ZnHg{sub 10} with new complex structure types. Black-Right-Pointing-Pointer Structure relation to other complex cubic intermetallics. Black-Right-Pointing-Pointer Discussion of covalent and metallic bonding aspects, as found by the structure features and band structure calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poromechanical cohesive interface element with combined Mode I-II cohesive zone elastoplasticity for simulating fracture in fluid-saturated porous media

A combined Mode I-II cohesive zone (CZ) elasto-plastic constitutive model, and a two-dimensional (2D) cohesive interface element (CIE) are formulated and implemented at small strain within an ABAQUS User Element (UEL) for simulating 2D crack nucleation and propagation in fluid-saturated porous media. Here, the CZ model mitigates problems of convergence for the global Newton-Raphson solver within ABAQUS, which when combined with a viscous stabilization procedure allows for simulation of post-peak response under load control for coupled poromechanical finite element analysis, such as concrete gravity dam stability analysis. Verification examples are presented, along with a more complex ambient limestone-concrete wedge fracture experiment, water-pressurized concrete wedge experiment, and concrete gravity dam stability analyses. A calibration procedure for estimating the CZ parameters is demonstrated with the limestone-concrete wedge fracture process. For the water-pressurized concrete wedge fracture experiment it is shown that the inherent time-dependence of the poromechanical CIE analysis provides a good match with experimental force versus displacement results at various crack mouth opening rates, yet misses the pore water pressure evolution ahead of the crack tip propagation. This is likely a result of the concrete being partially-saturated in the experiment, whereas the finite element analysis assumes fully water saturated concrete. For the concrete gravity dam analysis, it is shown that base crack opening and associated water uplift pressure leads to a reduced Factor of Safety, which is confirmed by separate analytical calculations.

97 MATHEMATICS AND COMPUTING↗

Interface tracking simulations of bubbly flows in PWR relevant geometries

[en] Highlights: • Simulations were performed for turbulent bubbly flows in PWR subchannel geometry. • Liquid turbulence is fully resolved by direct numerical simulation approach. • Bubble behavior is captured using level-set interface tracking method. • Time-averaged single- and two-phase turbulent flow statistical quantities are obtained. - Abstract: The advances in high performance computing (HPC) have allowed direct numerical simulation (DNS) approach coupled with interface tracking methods (ITM) to perform high fidelity simulations of turbulent bubbly flows in various complex geometries. In this work, we have chosen the geometry of the pressurized water reactor (PWR) core subchannel to perform a set of interface tracking simulations (ITS) with fully resolved liquid turbulence. The presented research utilizes a massively parallel finite-element based code, PHASTA, for the subchannel geometry simulations of bubbly flow turbulence. The main objective for this research is to demonstrate the ITS capabilities in gaining new insight into bubble/turbulence interactions and assisting the development of improved closure laws for multiphase computational fluid dynamics (M-CFD). Both single- and two-phase turbulent flows were studied within a single PWR subchannel. The analysis of numerical results includes the mean gas and liquid velocity profiles, void fraction distribution and turbulent kinetic energy profiles. Two sets of flow rates and bubble sizes were used in the simulations. The chosen flow rates corresponded to the Reynolds numbers of 29,079 and 80,775 based on channel hydraulic diameter (D_h) and mean velocity. The finite element unstructured grids utilized for these simulations include 53.8 million and 1.11 billion elements, respectively. This has allowed to fully resolve all the turbulence scales and the deformable interfaces of individual bubbles. For the two-phase flow simulations, a 1% bubble volume fraction was used which resulted in 17 bubbles in the smaller case and 262 bubbles in the larger case. In the larger simulation case the size of the resolved bubbles is 0.65 mm in diameter, and the bulk mesh cell size is about 30 microns. Those large-scale simulations provide new level of details previously unavailable and were enabled by the excellent scaling performance of our two-phase flow solver and access to the state-of-the-art supercomputing resources. The presented simulations used up to 256 thousand processing threads on the IBM BG/Q supercomputer “Mira” (Argonne National Laboratory).

Nuclear Science & Technology↗

Methods for Detector Placement and Analysis of Criticality Accident Alarm Systems

Determining the optimum placement to minimize the number of detectors for a criticality accident alarm system (CAAS) in a large manufacturing facility is a complex problem. There is typically a target for the number of detectors that can be used over a given zone of the facility. A study to optimize detector placement typically begins with some initial guess at the placement of the detectors and is followed by either predictive calculations of accidents at specific locations or adjoint calculations based on preferred detector locations. Within an area of a facility, there may be a large number of potential criticality accident sites. For any given placement of the detectors, the list of accident sites can be reduced to a smaller number of locations at which accidents may be difficult for detectors to detect. Developing the initial detector placement and determining the list of difficult accident locations are both based on the practitioner's experience. Simulations following fission particles released from an accident location are called 'forward calculations.' These calculations can be used to answer the question 'where would an alarm be triggered?' by an accident at a specified location. Conversely, 'adjoint calculations' start at a detector site using the detector response function as a source and essentially run in reverse. These calculations can be used to answer the question 'where would an accident be detected?' by a specified detector location. If the number of accidents, P, is much less than the number of detectors, Q, then forward simulations may be more convenient and less time-consuming. If Q is large or the detectors are not placed yet, then a mesh tally of dose observed by a detector at any location must be computed over the entire zone. If Q is much less than P, then adjoint calculations may be more efficient. Adjoint calculations employing a mesh tally can be even more advantageous because they do not rely on a list of specific difficult-to-detect accident sites, which may not have included every possible accident location. Analog calculations (no biasing) simply follow particles naturally. For sparse buildings and line-of-sight calculations, analog Monte Carlo (MC) may be adequate. For buildings with internal walls or large amounts of heavy equipment (dense geometry), variance reduction may be required. Calculations employing the CADIS method use a deterministic calculation to create an importance map and a matching biased source distribution that optimize the final MC to quickly calculate one specific tally. Calculations employing the FW-CADIS method use two deterministic calculations (one forward and one adjoint) to create an importance map and a matching biased source distribution that are designed to make the MC calculate a mesh tally with more uniform uncertainties in both high-dose and low-dose areas. Depending on the geometry of the problem, the number of detectors, and the number of accident sites, different approaches to CAAS placement studies can be taken. These are summarized in Table I. SCALE 6.1 contains the MAVRIC sequence, which can be used to perform any of the forward-based approaches outlined in Table I. For analog calculations, MAVRIC simply calls the Monaco MC code. For CADIS and FW-CADIS, MAVRIC uses the Denovo discrete ordinates (SN) deterministic code to generate the importance map and biased source used by Monaco. An adjoint capability is currently being added to Monaco and should be available in the next release of SCALE. An adjoint-based approach could be performed with Denovo alone - although fine meshes, large amounts of memory, and long computation times may be required to obtain accurate solutions. Coarse-mesh SN simulations could be employed for adjoint-based scoping studies until the adjoint capability in Monaco is complete. CAAS placement studies, especially those dealing with mesh tallies, require some extra utilities to aid in the analysis. Detectors must receive a minimum dose rate in order to alarm; therefore, a simple yes/no plot could be more useful to the analyst than a standard dose rate contour plot. Alarm systems that require several detectors to alarm simultaneously for a given accident would need to combine several yes/no plots in order to show accident sites where multiple detectors would be triggered. This could require a plot of 'areas of coverage' that is mapped over the building geometry. Several new utilities (which will be part of SCALE 6.2) were created to help with CAAS analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hybrid porous model for full reactor core scale CFD investigation of a prismatic HTGR

Three-dimensional (3-D) Computational Fluid Dynamics (CFD) analysis of a whole nuclear reactor core is a tremendous challenge due to the large geometric volume and complex structures. Here, this research presents a hybrid porous (HP) model to simplify a prismatic High Temperature Gas-cooled Reactor (HTGR) core, so 3-D CFD investigation can be performed on a full reactor core scale. In the HP model, the prototypic small coolant channels in the nuclear fuel blocks are lumped together to form multiple equivalent large coolant channels, and then the porous medium flow model is applied to each of them. Therefore, heat transfer in fuel blocks is computed by a hybrid combination of solid energy and porous flow energy equations. The similarity between the HP model and prototypic model is achieved by deriving the porous flow permeability, inertial resistance factor, and artificial thermophysical properties. Compared with the widely used whole porous (WP) flow model, the HP model preserves more realistic geometric structures, and therefore more accurate physical processes. The General Atomics' Modular High Temperature Gas-cooled Reactor (MHTGR) design was chosen as a prototype to demonstrate the methodology. Simulations were performed using the prototypic CFD model and HP model at steady-state forced circulation, steady-state natural circulation, and transient conditions that correspond to normal operation, extended period of pressurized cool down, and short-term transients after reactor shutdown, respectively. The comparison shows good agreement between the HP model and prototypic model in the maximum fuel temperature, average solid temperature, and helium flow rate, which demonstrates the potential applicability of the HP model for a full reactor core scale simulation in the future. As a benefit, the HP model reduces the mesh quantity by a factor of 50 from a prototypic model. Correspondingly, the computation time was reduced by a factor of at least 30.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Slip velocity boundary conditions for the lattice Boltzmann modeling of microchannel flows

Abstract Slip flows in ducts are important in numerous engineering applications, most notably in microchannel flows. Compared to the standard no‐slip Dirichlet condition, the case of slip formulates as a Robin‐type condition for the fluid tangential velocity. Such an increase in mathematical complexity is accompanied by a more challenging numerical transcription. The present work concerns with this topic, addressing the modeling of the slip velocity boundary condition in the lattice Boltzmann method (LBM) applied to steady slow viscous flows inside ducts of nontrivial shapes. As novelty, we extend the newly revised local second‐order boundary (LSOB) Dirichlet fluid flow method [ Philos. Trans. R. Soc. A 378, 20190404 (2020)] to implement the slip velocity condition within the two‐relaxation‐time (TRT) framework. The LSOB follows an in‐node philosophy where its operation principle seeks to explicitly reconstruct the unknown boundary populations in the form of a third‐order accurate Chapman–Enskog expansion, where the wall slip condition is built‐in as a normal Taylor‐type condition. The key point of this approach is that the required first‐ and second‐order momentum derivatives, rather than computed through nonlocal finite difference approximations, are locally determined through a simple local linear algebra procedure, whose formulation is particularly aided by the TRT symmetry argument. To express the obtained derivatives, two approaches are considered, called and , which operate with node and wall variables, respectively. These two formulations are developed to prescribe the physical slip condition over plane and curved walls, including the corners. Their consistency and accuracy characteristics are examined against alternative linkwise strategies to impose the wall slip velocity, such as the kinetic‐based diffusive bounce‐back scheme, the central linear interpolation slip scheme, and the multireflection slip scheme. The several slip schemes are tested over different 3D microchannel configurations, with walls not conforming with the LBM uniform mesh. Numerical tests confirm the advanced accuracy characteristics of the proposed LSOB slip boundary scheme, revealing the added challenge of the wall slip modeling, and that parabolic accuracy is a necessary requirement to reach second‐order accuracy within this problem class.

Silva, Goncalo↗

Multi-plane moment-of-fluid interface reconstruction in 3D

Moment-of-fluid (MOF) methods for interface reconstruction approximate the region occupied by material in each mesh element only through reference to its geometric moments. Here, we present a 3D MOF method that represents the material (POM) in each cell as the convex intersection of the cell and multiple half-spaces, each selected to minimize the least-squares error between computed moments of the approximated material and provided reference moments. This optimization problem is highly non-linear and non-convex, making the numerical result very sensitive to the initial guess. To create an effective initial guess in each cell, we construct an ellipsoid from 0th–2nd order reference moments such that its shape corresponds with that of the POM. Within this ellipsoid we inscribe a polyhedron, and initialize the minimization problem with the half-spaces defined by each of its faces. The inscribed polyhedron has minimally 4 faces, and using up to 3rd order moments permits optimization over up to 20 unknown values. We therefore define MOF methods that utilize 4, 5, or 6 half-spaces, correspondingly initialized with the faces of a single inscribed tetrahedron, triangular prism, or hexahedron. Stability of the non-linear optimization is further improved with a prepossessing step that normalizes the reference moments according to the axes of the reference ellipsoid. Using this approach, the non-linear least-squares solver reliably converges to a near-global minimum from a single initial guess. We demonstrate accuracy and robustness using single-cell and multi-cell examples over a wide spectrum of geometry. In particular, we demonstrate our ability to exactly reproduce several important and complex features defined by up to four half-spaces, such as corners, filaments, filament tips, and embedded material in the cell.

3D interface reconstruction↗

Assessment and validation of NEAMS tools for high-fidelity multiphysics transient modeling of microreactors: Application of NEAMS codes to perform multiphysics modeling analyses of micro-reactor concepts

The NEAMS Multiphysics Applications team aims at providing assessment of code useability and functionality for microreactor design and analyses, together with demonstration of their capabilities to properly capture the steady-state and time-dependent behavior of different microreactor concepts. In FY-24, significant progress was achieved in improving multi-physics models of several microreactors systems: HP-MR, GC-MR and KRUSTY. These efforts focused on solving more complex multiphysics problems enabled by enhanced tools capability, verifying and validating results obtained, providing feedback to developers for suggested improvements, and sharing these models to facilitate user training. A series of new multiphysics transients were completed on the HP-MR (using Griffin/BISON/Sockeye) with core startup transient, control drum inadvertent rotation accident, and hydrogen leakage from hydride moderator (also including SWIFT). On the GC-MR, a new full-core model was developed and analyzed through a series of new multiphysics (Griffin/BISON/SAM) transients to simulate moderator leakage (also including SWIFT), flow blockage and coolant depressurization. Additional and updated TRISO failure analyses were completed on the HP-MR unit-cell and GC-MR assembly models leveraging improved TRISO modeling capabilities. The amount of SiC failure following accidental transients at end-of-life was null. However, GC-MR assembly TRISO analysis highlighted Pd penetration rate can be problematic and may require design changes on the studied microreactor concept. The neutronics discrepancies observed on the KRUSTY model in previous years were resolved using hybrid set of Monte Carlo/Deterministic cross-sections. The multiphysics (Griffin neutronics / BISON thermal-mechanics) 15₵ insertion transient simulation displayed good agreement when comparing with experimental data. Initial modeling of the 30 ₵ reactivity insertion also displays promising results. Such close agreement provides important validation data that can be leveraged by the NEAMS program and by microreactor vendors to support licensing of their technology. Finally, important experience was gathered with the NEAMS tools leading to several user feedback shared with tools developers, especially with regards to MOOSE mesh generator and Griffin. This project led to many publications demonstrating modeling capabilities, and to three models shared on the Virtual Test Bed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On the convergence and convergence order of finite volume gradient schemes for oblique derivative boundary value problems

This work is an improvement of the previous note (Bradji in: Fuhrmann et al., Finite volumes for complex applications VII–methods, theoretical aspects. Proceedings of the FVCA 7, Berlin, 2014) which dealt with the convergence analysis of a finite volume scheme for the Poisson’s equation with a linear oblique derivative boundary condition. The formulation of the finite volume scheme given in Bradji (in: Fuhrmann et al., Finite volumes for complex applications VII–methods, theoretical aspects. Proceedings of the FVCA 7, Berlin, 2014) involves the discrete gradient introduced recently in Eymard et al. (IMA J Numer Anal 30(4):1009–1043, 2010). In this paper, we consider the convergence analysis of finite volume schemes involving the discrete gradient of Eymard et al. (IMA J Numer Anal 30(4):1009–1043, 2010) for elliptic and parabolic equations with linear oblique derivative boundary conditions. Linear oblique derivative boundary conditions arise for instance in the study of the motion of water in a canal, cf. Lesnic (Commun Numer Methods Eng 23(12):1071–1080, 2007). We derive error estimates in several norms which allow us to get error estimates for the approximations of the exact solutions and its first derivatives. In particular, we provide an error estimate between the gradient of the exact solutions and the discrete gradient of the approximate solutions. Convergence of the family of finite volume approximate solutions towards the exact solution under weak regularity assumption is also investigated. In the case of parabolic equations with oblique derivative boundary conditions, we develop a new discrete a priori estimate result. The proof of this result is based on the use of a discrete mean Poincaré–Wirtinger inequality. Thanks to the stated a priori estimate and to a comparison with an appropriately chosen auxiliary finite volume scheme, we derive the convergence results. This work can be viewed as a continuation of the previous work (Bradji and Gallouët in Int J Finite Vol 3(2):1–35, 2006) where a convergence analysis for a finite volume scheme, based on the admissible mesh of Eymard et al. (In: Ciarlet and Lions, Handbook of numerical analysis, North-Holland, Amsterdam, 2000), for the Poisson’s equation with a linear oblique derivative boundary conditions is given. The obtained convergence results do not require any relation between the mesh sizes of the spatial and time discretizations. Some numerical tests are presented for both elliptic and parabolic equations. In particular, we present three methods to compute the discrete solution.

97 MATHEMATICS AND COMPUTING↗

Trigger Detection for Adaptive Scientific Workflows Using Percentile Sampling

The increasing complexity of both scientific simulations and high-performance computing system architectures are driving the need for adaptive workflows, in which the composition and execution of computational and data manipulation steps dynamically depend on the evolutionary state of the simulation itself. Consider, for example, the frequency of data storage. Critical phases of the simulation should be captured with high frequency and with high fidelity for postanalysis; however, we cannot afford to retain the same frequency for the full simulation due to the high cost of data movement. We can instead look for triggers, indicators that the simulation will be entering a critical phase, and adapt the workflow accordingly. In this paper, we present a methodology for detecting triggers and demonstrate its use in the context of direct numerical simulations of turbulent combustion using S3D. We show that chemical explosive mode analysis (CEMA) can be used to devise a noise-tolerant indicator for rapid increase in heat release. However, exhaustive computation of CEMA values dominates the total simulation, and thus is prohibitively expensive. To overcome this computational bottleneck, we propose a quantile sampling approach. Our sampling-based algorithm comes with provable error/confidence bounds, as a function of the number of samples. Most importantly, the number of samples is independent of the problem size, and thus our proposed sampling algorithm offers perfect scalability. Our experiments on homogeneous charge compression ignition and reactivity controlled compression ignition simulations show that the proposed method can detect rapid increases in heat release, and its computational overhead is negligible. Our results will be used to make dynamic workflow decisions regarding data storage and mesh resolution in future combustion simulations.

97 MATHEMATICS AND COMPUTING↗

Technology demonstration for reducing mercury emissions from small-scale gold refining facilities.

Gold that is brought from artisanal and small-scale gold mining areas to gold shops for processing and sale typically contains 5-40% mercury. The uncontrolled removal of the residual mercury in gold shops by using high-temperature evaporation can be a significant source of mercury emissions in urban areas where the shops are located. Emissions from gold shop hoods during a burn can exceed 1,000 mg/m{sup 3}. Because the saturation concentration of mercury vapor at operating temperatures at the hood exhaust is less than 100 mg/m{sup 3}, the dominant component of the exhaust is in the form of aerosol or liquid particles. The U.S. Environmental Protection Agency (EPA), with technical support from Argonne National Laboratory (Argonne), has completed a project to design and test a technology to remove the dominant aerosol component in the emissions from gold shops. The objective was to demonstrate a technology that could be manufactured at low cost and by using locally available materials and manufacturing capabilities. Six prototypes designed by Argonne were locally manufactured, installed, and tested in gold shops in Itaituba and Creporizao, Brazil. The initial prototype design incorporated a pebble bed as the media for collecting the mercury aerosols, and a mercury collection efficiency of over 90% was demonstrated. Though achieving high efficiencies, the initial prototype was determined to have practical disadvantages such as excessive weight, a somewhat complex construction, and high costs (>US$1,000). To further simplify the construction, operation, and associated costs, a second prototype design was developed in which the pebble bed was replaced with slotted steel baffle plates. The system was designed to have flexibility for installation in various hood configurations. The second prototype with the baffle plate design was installed and tested in several different hood/exhaust systems to determine the optimal installation configuration. The significance of coagulation and collection of the mercury aerosols in exhaust ducts, which is dependent on the hood and collector configuration, was also evaluated. Prototype demonstration tests verified the theoretical basis for mercury aerosol capture that can be used to optimize the baffle plate design, flow rates, and hood exhaust ducts and plenum to achieve 80% or higher removal efficiencies. Results indicated that installation configuration significantly influences a system's capture efficiency. Configurations that retained existing inlet ducts resulted in system efficiencies of more than 80%, whereas installation configurations without inlet ducts significantly reduced capture efficiency. As an alternative to increasing the volume of inlet ducts, the number of baffle plates in the system baffle assembly could be doubled to increase efficiency. Recommended installation and operation procedures were developed on the basis of these results. A water-based mercury capture system developed in Indonesia for installation in smaller shops was also tested and shown to be effective for certain applications. The cost of construction and installation of the baffle plate prototype was approximately US$400. These costs were reported as acceptable by local gold shop owners and government regulators, and were significantly lower than the cost of an alternate charcoal/copper mesh mercury filter available in the region, which costs about US$10,000. A sampling procedure that consists of a particle filter combined with a vapor analyzer was demonstrated as an effective procedure for analyzing both the aerosol and vapor components of the mercury concentrations. Two key findings for enhancing higher mercury collection were identified. First, the aerosol/vapor mercury emissions must be given sufficient time for the mercury particles to coagulate to a size that can be readily captured by the baffle plates. An interval of at least 6 seconds of transit time between the point of evaporation and contact with the slotted baffle plates is recommended. Some particles will also deposit in the exhaust ducts between the point of evaporation and the baffle plates. Second, the slots in the baffle plates create jets that force the mercury particles to impinge and adhere on downstream surfaces. The baffle plates should closely follow the designs developed for this system to be most effective.

54 ENVIRONMENTAL SCIENCES↗

THE ANGULAR MOMENTUM OF MAGNETIZED MOLECULAR CLOUD CORES: A TWO-DIMENSIONAL-THREE-DIMENSIONAL COMPARISON

In this work, we present a detailed study of the rotational properties of magnetized and self-gravitating dense molecular cloud (MC) cores formed in a set of two very high resolution three-dimensional (3D) MC simulations with decaying turbulence. The simulations have been performed using the adaptative mesh refinement code RAMSES with an effective resolution of 4096{sup 3} grid cells. One simulation represents a mildly magnetically supercritical cloud and the other a strongly magnetically supercritical cloud. We identify dense cores at a number of selected epochs in the simulations at two density thresholds which roughly mimic the excitation densities of the NH{sub 3} (J - K) = (1,1) transition and the N{sub 2}H{sup +} (1-0) emission line. A noticeable global difference between the two simulations is the core formation efficiency (CFE) of the high-density cores. In the strongly supercritical simulations, the CFE is 33% per unit free-fall time of the cloud (t{sub ff,cl}), whereas in the mildly supercritical simulations this value goes down to {approx}6 per unit t{sub ff,cl}. A comparison of the intrinsic specific angular momentum (j{sub 3D}) distributions of the cores with the specific angular momentum derived using synthetic two-dimensional (2D) velocity maps of the cores (j{sub 2D}) shows that the synthetic observations tend to overestimate the true value of the specific angular momentum by a factor of {approx}8-10. We find that the distribution of the ratio j{sub 3D}/j{sub 2D} of the cores peaks at around {approx}0.1. The origin of this discrepancy lies in the fact that contrary to the intrinsic determination of j which sums up the individual gas parcels' contributions to the angular momentum, the determination of the specific angular momentum using the standard observational procedure which is based on a measurement on the global velocity gradient under the hypothesis of uniform rotation smoothes out the complex fluctuations present in the 3D velocity field. Our results may well provide a natural explanation for the discrepancy by a factor of {approx}10 observed between the intrinsic 3D distributions of the specific angular momentum and the corresponding distributions derived in real observations. We suggest that previous and future measurements of the specific angular momentum of dense cores which are based on the measurement of the observed global velocity gradients may need to be reduced by a factor of {approx}10 in order to derive a more accurate estimate of the true specific angular momentum in the cores. We also show that the exponent of the size-specific angular momentum relation is smaller ({approx}1.4) in the synthetic observations than their values derived in the 3D space ({approx}1.8).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Particle-in-Cell Method for Plasmas with a Generalized Momentum Formulation, Part II: Enforcing the Lorenz Gauge Condition

In a previous paper Christlieb et al. (A particle-in-cell method for plasmas with a generalized momentum formulation, part I: Model formulation, 2024), we developed a new particle-in-cell (PIC) method for the relativistic Vlasov–Maxwell system in which the electromagnetic fields and the equations of motion for the particles were cast in terms of scalar and vector potentials through a Hamiltonian formulation. This new method evolved the potentials under the Lorenz gauge using integral equation methods. New methods to construct spatial derivatives of the potentials that converge at the same rates as the fields were also presented. The new particle method was compared against standard explicit discretizations, including the well-known FDTD-PIC method, for a range of applications involving sheaths and particle beams. Here, this paper extends this new class of methods by focusing on the enforcement the Lorenz gauge condition in both exact and approximate forms using co-located meshes. A time-consistency property of the proposed field solver for the vector potential form of Maxwell’s equations is established, which is shown to preserve the equivalence between the semi-discrete Lorenz gauge condition and the analogous semi-discrete continuity equation. Using this property, we present three methods to enforce a semi-discrete gauge condition. The first method introduces an update for the continuity equation that is consistent with the discretization of the Lorenz gauge condition. Both the finite difference and spectral implementations satisfy this discrete gauge condition to machine precision. The second approach we propose enforces a semi-discrete continuity equation using the boundary integral solution to the field equations. The potential benefit of this approach is that it eliminates spatial derivatives that appear on the particle data, namely the current density, which is often calculated by linear combinations of low-order spline basis functions. This method is ideally suited to boundary integral equation methods that invert multi-dimensional operators without dimensional splitting techniques and will be the subject of future work. The third approach introduces a gauge correcting method that makes direct use of the gauge condition to modify the scalar potential and uses local maps for both the charge and current densities. This results in a gauge error, as the maps do not enforce the continuity equation. The vector potential coming from the current density is taken to be exact, and using the Lorenz gauge, we compute a correction to the scalar potential that makes the two potentials satisfy the gauge condition. This method also enforces the gauge condition to machine precision. We demonstrate two of the proposed methods in the context of periodic domains. Problems defined on bounded domains, including those with complex geometric features remain an ongoing effort. However, this work shows that it is possible to design computationally efficient methods that can effectively enforce the Lorenz gauge condition in a non-staggered PIC formulation.

97 MATHEMATICS AND COMPUTING↗

Computational thermal, chemical, fluid, and solid mechanics for geosystems management.

This document summarizes research performed under the SNL LDRD entitled - Computational Mechanics for Geosystems Management to Support the Energy and Natural Resources Mission. The main accomplishment was development of a foundational SNL capability for computational thermal, chemical, fluid, and solid mechanics analysis of geosystems. The code was developed within the SNL Sierra software system. This report summarizes the capabilities of the simulation code and the supporting research and development conducted under this LDRD. The main goal of this project was the development of a foundational capability for coupled thermal, hydrological, mechanical, chemical (THMC) simulation of heterogeneous geosystems utilizing massively parallel processing. To solve these complex issues, this project integrated research in numerical mathematics and algorithms for chemically reactive multiphase systems with computer science research in adaptive coupled solution control and framework architecture. This report summarizes and demonstrates the capabilities that were developed together with the supporting research underlying the models. Key accomplishments are: (1) General capability for modeling nonisothermal, multiphase, multicomponent flow in heterogeneous porous geologic materials; (2) General capability to model multiphase reactive transport of species in heterogeneous porous media; (3) Constitutive models for describing real, general geomaterials under multiphase conditions utilizing laboratory data; (4) General capability to couple nonisothermal reactive flow with geomechanics (THMC); (5) Phase behavior thermodynamics for the CO2-H2O-NaCl system. General implementation enables modeling of other fluid mixtures. Adaptive look-up tables enable thermodynamic capability to other simulators; (6) Capability for statistical modeling of heterogeneity in geologic materials; and (7) Simulator utilizes unstructured grids on parallel processing computers.

99 GENERAL AND MISCELLANEOUS↗

Assessment of Multi-Step CADIS Parameter Sensitivity to Neutron Flux Spectrum in Shutdown Dose Rate Calculations

Shutdown dose rate (SDDR) analysis requires (a) a neutron transport calculation to estimate neutron flux fields, (b) an activation calculation to compute radionuclide inventories and associated photon sources, and (c) a photon transport calculation to estimate final dose rate. In some applications, accurate full-scale Monte Carlo (MC) SDDR simulations are needed for very large systems with massive amounts of shielding materials. For example, SDDR assessments are required throughout the biological shield (bio-shield) of the ITER experimental facility to evaluate the required waiting period after the shutdown of ITER and to identify the locations where human accessibility should be prohibited. The bio-shield is a large cylindrical concrete structure (30 m tall and 34 m in diameter) surrounding the very complex tokamak machine. Determining the effects on SDDR of important factors, such as the cross talk (interactions) between the different ports of ITER, is possible only through full-scale simulations that involve all the complex inner details of the ITER tokamak machine. These simulations are impractical because calculation of space- and energy-dependent neutron fluxes throughout the structural materials is needed to estimate the distribution of radioisotopes causing the SDDR. Determining a good importance function that can be used in biasing a neutron MC calculation for SDDR is complicated because it is difficult to explicitly express the SDDR response function, which depends on subsequent computational steps. The Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) hybrid MC/deterministic method was developed to speed up the SDDR MC neutron transport calculation using an importance function that represents the neutron importance to the final SDDR. The MS-CADIS method uses the CADIS method, which has been Notice: This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC0500OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for the United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan). successfully used for more than a decade in radiation shielding applications to generate consistent source biasing and weight window (WW) variance reduction parameters to accelerate continuous-energy MC simulations. However, because MS-CADIS focuses on multi-step shielding calculations such as SDDR calculations, it develops an importance function for the initial radiation transport calculation (e.g., the neutron calculations in SDDR simulations) that represents the importance of particles to the final response of the overall simulation. To develop this importance function, the MS-CADIS method uses an adjoint calculation with a specific neutron adjoint source that represents the neutron's contribution to the final SDDR. Brute force calculation of the MS-CADIS neutron adjoint source requires a deterministic neutron transport calculation coupled with activation calculations in each element of the deterministic mesh. These calculations are needed to determine the MS-CADIS parameter for the neutron interactions that produce radioisotopes contributing to the SDDR. The MS-CADIS parameter is the microscopic cross section of the radioisotope-producing interaction, multiplied by the mass of this radioisotope existing at the end of the irradiation and decay scenario, and divided by the steady-state rate of the interaction. Because the activation calculations are performed for each radionuclide in each mesh element, implementation of the MS-CADIS method can be computationally expensive. However, these neutron transport and activation calculations are not needed if we assume that the radioisotopes are created due to single neutron interactions and their concentrations do not change as a result of burnup by neutron irradiation. The use of this approximation, which renders the MS-CADIS parameter independent of the neutron flux, seems reasonable in calculating the MS-CADIS importance function because this function is needed only to speed up the MC calculation, not to calculate the final SDDR. In this work, we investigate the validity of this approximation by investigating the behavior of the MS-CADIS parameter as a function of the neutron flux spectra in the Fusion Evaluated Nuclear Data Library (FENDL) Neutronics and Shielding Benchmark problem that contains representative isotopes and flux environments of fusion energy systems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗