Evaluation of Distributed Power Apportioning with Net Load Management Engine in Microgrids Using Power Hardware-in-the-Loop Simulation

This article presents the performance evaluation of ratio consensus-based distributed power apportioning engine along with centralized net load management (NLM) engine that ensures viable and stable operation of an islanded microgrid. Managing net load variability in a microgrid with high penetrations of uncertain renewable generation and ever-changing load demands is a crucial need in order to ensure viable and stable operation of the microgrid. Centralized “dispatch-rule”-based and/or multi-agent-based distributed control of distributed energy resources (DERs) in microgrid are well accepted for microgrid by adapting ANSI/ISA-95-based hierarchical control architecture. In the application where microgrid network has large geographical span with multiple DERs dispersed in the network, high penetration of uncertain renewable energy resources, and ever-changing load demands, a judicious selection of techniques/solutions for managing net-load resources for maintaining viability and stability is required. With this motivation, this article proposes a novel solution to mitigate the challenges by incorporating a mixed centralized NLM engine and distributed power apportioning control of DERs and loads. A power-hardware-in-the-loop (PHIL) -based experiment is conducted with the centralized NLM engine and the distributed power apportioning engine along with two commercial inverters. The experimental results validates the efficacy of the proposed method in ensuring viability and stability of a microgrid.

hardware-in-the-loop simulation↗

Mitigating Phase Unbalance for Distribution Systems with High Penetrations of Solar PV (Final Technical Report)

Distribution system operators have traditionally limited unbalance among phases by maintaining similar loadings on each phase. High penetrations of distributed solar PV continually change the net loading on each phase, resulting in time-varying phase unbalances that can damage three-phase devices such as three-phase motors, violate grid codes, and increase technical losses. This project has developed several control strategies for the reactive power outputs of solar PV inverters in order to mitigate power quality issues related to phase unbalance. These control strategies include a decentralized approach that is solely based on local measurements, distributed and grouped approaches that consider subsets of loads and PV generators, and a centralized approach that leverages measurements from a variety of locations in order to compute optimal reactive power setpoints for each inverter. Variants of the controllers handle challenges relevant to practical implementations, including noisy measurements, delayed communications, and reactive power limits. Moreover, the project developed theory that provides convergence guarantees for systems with multiple interacting controllers as well as “balanceability” certificates that ensure satisfaction of phase unbalance requirements with variable loading. The controllers were integrated with NRECA’s Open Modeling Framework (omf.coop) and evaluated using actual distribution system models obtained from several NRECA member utilities. Application of the controllers results in significant improvements to phase unbalance in these test cases with decreases from base case levels of over 3% to under 0.5%, which is within the 2% IEC phase unbalance standard.

14 SOLAR ENERGY↗

Assessment of wind turbine component loads under yaw-offset conditions

Abstract. Renewed interest in yaw control for wind turbine and power plants for wake redirection and load mitigation demands a clear understanding of the effects of running with skewed inflow. In this paper, we investigate the physics of yawed operations, building up the complexity from a simplified analytical treatment to more complex aeroelastic simulations. Results in terms of damage equivalent loads (DELs) and extreme loads under misaligned conditions of operation are compared to data collected from an instrumented, utility-scale wind turbine. The analysis shows that multiple factors are responsible for the DELs of the various components and that airfoil aerodynamics, elastic characteristics of the rotor, and turbulence intensities are the primary drivers. Both fatigue and extreme loads are observed to have relatively complex trends with yaw offsets, which can change depending on the wind-speed regime. Good agreement is found between predicted and measured trends for both fatigue and ultimate loads.

Damiani, Rick↗

Criticality Safety Analysis of Spent Nuclear Fuel Canisters Using As-Loaded Configurations

Dual purpose canisters (DPCs) used for storage and transportation of spent nuclear fuel (SNF) are typically designed and evaluated using bounding (enveloping) fuel characteristics such as fuel type, fuel dimensions, initial enrichment, discharge burnup, and cooling time. This is a design basis, bounding licensing approach for SNF storage and transportation systems, as licensing and supporting safety analysis reviews are performed prior to the actual fuel loading. The bounding fuel characteristics for a system are developed by fully utilizing the regulatory and regulators recommended safety limits such as neutron multiplication factor (keff) approaching 0.95 to maximize the system utilizations. In reality, there are wide variations in SNF assembly burnups, initial enrichments, and cooling times. Therefore, dry storage systems are typically loaded with assemblies that satisfy the bounding fuel characteristics defined in the certificate of compliance (CoC), with some amount of unquantified and uncredited margin. This paper presents an as-loaded canister-specific criticality analysis approach for quantifying inherent uncredited margins in already loaded DPCs. The as-loaded analysis approach has been implemented in a new SNF management and analysis tool - The Used Nuclear Fuel-Storage, Transportation, and Disposal Analysis Resource and Data System (UNF ST&DARDS). The paper presents as-loaded criticality analysis of 616 canisters at 28 US reactor sites. Additionally, the paper discusses as-loaded analysis methodology validation approach using detailed reactor operational and fuel design data.

Banerjee, Kaushik↗

Rotary valve controls multiple hydraulic leveling cylinders

Single rotary valve controls a circular bank of hydraulic leveling cylinders that must maintain large loads within plus or minus three arc minutes of the true vertical. Since the position of the valve spool determines the flow rate of each bank of cylinders and hence cylinder position, different flow rates may be obtained by changing the spool shape.

Source record↗

Cataloging the visible universe through Bayesian inference in Julia at petascale

A key task in astronomy is to locate astronomical objects in images and to characterize them according to physical parameters such as brightness, color, and morphology. This task, known as cataloging, is challenging for several reasons: many astronomical objects are much dimmer than the sky background, labeled data is generally unavailable, overlapping astronomical objects must be resolved collectively, and the datasets are enormous – terabytes now, petabytes soon. In this work, we infer an astronomical catalog from 55 TB of imaging data using Celeste, a Bayesian variational inference code written entirely in the high-productivity programming language Julia. Using over 1.3 million threads on 650,000 Intel Xeon Phi cores of the Cori Phase II supercomputer, Celeste achieves a peak rate of 1.54 DP PFLOP/s. Celeste is able to jointly optimize parameters for 188 M stars and galaxies, loading and processing 178 TB across 8192 nodes in 14.6 min. To achieve this, Celeste exploits parallelism at multiple levels (cluster, node, and thread) and accelerates I/O through Cori’s burst buffer. Julia’s native performance enables Celeste to employ high-level constructs without resorting to hand-written or generated low-level code (C/C++/Fortran) while still achieving petascale performance.

Regier, Jeffrey↗

Toward Development of a Stochastic Wake Model: Validation Using LES and Turbine Loads

Wind turbines within an array do not experience free-stream undisturbed flow fields. Rather, the flow fields on internal turbines are influenced by wakes generated by upwind unit and exhibit different dynamic characteristics relative to the free stream. The International Electrotechnical Commission (IEC) standard 61400-1 for the design of wind turbines only considers a deterministic wake model for the design of a wind plant. This study is focused on the development of a stochastic model for waked wind fields. First, high-fidelity physics-based waked wind velocity fields are generated using Large-Eddy Simulation (LES). Stochastic characteristics of these LES waked wind velocity field, including mean and turbulence components, are analyzed. Wake-related mean and turbulence field-related parameters are then estimated for use with a stochastic model, using Multivariate Multiple Linear Regression (MMLR) with the LES data. To validate the simulated wind fields based on the stochastic model, wind turbine tower and blade loads are generated using aeroelastic simulation for utility-scale wind turbine models and compared with those based directly on the LES inflow. The study’s overall objective is to offer efficient and validated stochastic approaches that are computationally tractable for assessing the performance and loads of turbines operating in wakes.

17 WIND ENERGY↗

Testing and analysis of flat and curved panels with multiple cracks

An experimental and analytical investigation of multiple cracking in various types of test specimens is described in this paper. The testing phase is comprised of a flat unstiffened panel series and curved stiffened and unstiffened panel series. The test specimens contained various configurations for initial damage. Static loading was applied to these specimens until ultimate failure, while loads and crack propagation were recorded. This data provides the basis for developing and validating methodologies for predicting linkup of multiple cracks, progression to failure, and overall residual strength. The results from twelve flat coupon and ten full scale curved panel tests are presented. In addition, an engineering analysis procedure was developed to predict multiple crack linkup. Reasonable agreement was found between predictions and actual test results for linkup and residual strength for both flat and curved panels. The results indicate that an engineering analysis approach has the potential to quantitatively assess the effect of multiple cracks in the arrest capability of an aircraft fuselage structure.

Broek, David↗

Job Scheduler-Driven Power Gateway for High Performance Computing

Power gateways in the form of a microgrid can incorporate multiple distributed energy resources (DER) in either grid forming or grid following mode and support high performance computing (HPC) power profiles including the large load-follow requirements observed in multi-user HPC systems. The microgrid’s flexibility to operate in either grid forming or grid following mode and to actively switch between these modes enables baseline power from multiple non-baseline DER while maintaining high power quality metrics for the HPC system. But this enormous flexibility in demand response and time of use shifting is generally programmed independently of any integration with an HPC job scheduler which can better inform the load shaping by the microgrid. While there are many existing approaches where the HPC job scheduler takes in information from the grid to make queue scheduling decisions, this work takes the opposite view and explores a scheduler where the jobs in the queue can directly impact the settings of the grid. Several HPC scheduler strategies are tested where the jobs in the queue directly impact the settings of a microgrid designed for HPC operation which is driving a datacenter with three classes of HPC architectures. The scheduler operation is shown using a microgrid with 64 kW of solar capacity and 320 kWh of battery over a period of 21 days operating with significant low-follow swings, a throttled grid, cloudy conditions, switching between grid following and grid forming modes, and a wide range of battery states-of-charge all while maintaining high quality power metrics. The scheduler provides a mechanism for the job queue to directly impact a power gateway like a microgrid and to improve HPC power outcomes such as maximizing renewable energy usage

microgrid↗

Implementation of ANL’s Mechanics Based Evolutionary Fatigue Modeling Through ABAQUS-WARP3D Based High-Performance Computing Framework

This report presents an update on the environmental fatigue research that is being conducted at Argonne National Laboratory in support of the Department of Energy’s Light Water Reactor Sustainability (LWRS) program. Argonne is developing a fully mechanistic fatigue evaluation approach without using empirical fatigue (S~N) curves. This approach is based on the fundamental concept of the time evolution of progressive fatigue damage rather than on the conventional S~N curve approaches using end-of-life data. In FY 2017, we performed extensive validation of this approach with respect to fatigue test data for 316 stainless steel [1]. This validation was performed for different loading cases, including constant, variable, and random amplitude. In the present FY 2018 semi-annual report, we present the further advances of Argonne’s environmental fatigue research work in the context for more practical applications. In this report, we discuss a methodology for fully mechanistic (i.e., not using S~N curves) fatigue life evaluation of reactor components subjected to realistic loading cycles, namely, design-basis loading cycles. The loading cycles include plant heat-up, full-power, and cool-down operations. As a test case, we considered a typical pressurized water reactor surge line, which is made of 316 SS. To perform the fatigue simulation for thousands of fatigue cycles in a computationally cost effective way, we modified our previous desktop-based finite element (FE) modeling approach to work in a high-performance computing (HPC) framework. For the HPC implementation, we developed a hybrid framework based on commercial FE software (ABAQUS), open-source FE software (WARP3D), and Argonne-developed evolutionary cyclic-plasticity modeling methods. We validated this HPC-based cycle-by-cycle damage model for the entire fatigue life of a Pressurized Water Reactor (PWR) surge line (SL) pipe with respect to assumed loading cycles. The simulated fatigue life was found to be 5855 cycles, which is 85% accurate as compared to the corresponding small-specimen-based experimental fatigue life (6914 cycles). Also, the simulated stress history captures the cyclic hardening and softening behavior of the material for entire fatigue cycles. The FE simulation of the PWR SL pipe was conducted in a reasonable time of 12.5 days. These results show the promise that a fully mechanistic (not using S~N curves) fatigue life evaluation of a safety-critical nuclear reactor component (or even other safety critical components like those in aircraft, aero-engines, etc.) is possible. We anticipate that this type of methodology will drastically reduce the uncertainly associated with conventional fatigue life estimates based on empirical S~N curves. We also proposed an FE model that is based on a hybrid full-component and single-element approach and that can readily be used by industry if HPC resources are not available. In this approach, a single-cycle FE simulation has to be performed first for the required loading cycle. Then, the resulting strain/stress profile at the hotspot (highest strain/stress location) is used as input strain/stress loading to the single-element FE model. The single-element FE model is run under multiple fatigue cycles as long as the failure criteria are achieved. The cycle number at failure gives the fatigue life of the component in question. This cost-effective framework does not require expensive HPC hardware and can be performed in a reasonable time by using a desktop computer. We demonstrated this approach with respect to PWR SL fatigue evaluation under two realistic design-basis loading cycles (simple and detailed). The associated results were validated with respect to test data obtained through fatigue testing of uniaxial specimens under the in-air condition at 300 °C. The approach is in the development stage and requires further improvement and validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An ICA-Based HVAC Load Disaggregation Method Using Smart Meter Data

This paper presents an independent component analysis (ICA) based unsupervised-learning method for heat, ventilation, and air-conditioning (HVAC) load disaggregation using row-resolution (i.e., 15 minutes) smart meter data. We first demonstrate that the electricity consumption profiles on mild-temperature days can be used to approximate the base load on hot days. A residual load profile can then be calculated by subtracting the mild-day load profile from the hot-day load profile. The residual load profiles are processed using ICA for HVAC load extraction. An optimization-based algorithm is proposed for post-adjustment of the ICA results, considering two bounding factors for enhancing the robustness of the ICA algorithm. First, we use the hourly HVAC energy bounds computed from the relationship between HVAC load and temperature to remove unrealistic HVAC load spikes. Second, we exploit the dependency between the daily nocturnal and diurnal loads extracted from historical meter data to smooth the base load profile. Pecan Street data with sub-metered HVAC data were used to test and verify the proposed methods. Simulation results demonstrated that the proposed method is computationally efficient and robust across multiple customers.

Kim, Hyeonjin↗

Reviewing Spent Nuclear Fuel Dry Cask Storage Programs to Identify Challenges for an Integrated Waste Management System - 17535

Under the Nuclear Waste Policy Act (NWPA), the U.S. Department of Energy (DOE) has responsibility for removing commercial spent nuclear fuel (SNF) from nuclear power plant sites and disposing of the SNF in a deep geologic repository. However, the methods used by commercial nuclear power plants for onsite storage of their SNF define the starting conditions for DOE efforts to develop a waste management system that includes packaging, transportation, storage, and disposal of commercial SNF. The NWPA (as amended) also charges the U.S. Nuclear Waste Technical Review Board (Board) with evaluating the technical and scientific validity of DOE activities related to the management and disposal of SNF and high-level radioactive wastes (HLW). DOE's efforts related to developing an integrated program for storing, transporting, and disposing of SNF and HLW were the focus of a public meeting held by the Board on August 24, 2016, in Washington, D.C. To prepare for the public meeting, the Board's staff compiled information on the dry cask storage systems in service at nuclear power plant sites in order to identify issues that would need to be addressed by DOE in planning to transport SNF away from the sites. This paper is based on a briefing presented to the Board members by the Board's staff before the public meeting. Post-meeting findings and recommendations of the Nuclear Waste Technical Review Board are documented in the Board letter to the Department of Energy dated December 8, 2016. A note about terminology: in this paper, the phrase 'dry cask storage system' is generic and applies to a complete system used for dry storage of commercial SNF.Within these storage systems, commercial SNF is sealed inside a container called either a cask or a canister depending upon the specific type of storage system used. This distinction is discussed in more detail in the body of this paper. When referring to the containers holding SNF in particular systems, this paper uses the terms 'casks' or 'canisters,' as appropriate. When discussing the collective group of all containers, this paper uses the phrase 'casks and canisters'. Dry cask storage of SNF is a widespread practice throughout the U.S. commercial nuclear industry. As of August 1, 2016, more than 2300 storage casks and canisters were loaded at U.S. commercial nuclear power plant sites. This number is expected to increase by more than 200 casks and canisters annually, reaching a total of approximately 4500 by 2025. Multiple vendors have developed their own unique designs of dry cask storage and transportation systems. The majority of storage system designs (75 percent) feature SNF loaded in welded stainless steel canisters that are stored in ventilated concrete overpacks that allow for convection cooling. Some older dry cask storage system designs do not include a welded stainless steel canister; instead, SNF is loaded directly into a heavily shielded metal cask to minimize radiation exposure to workers and prevent atmospheric release of radionuclides. These types of systems are sealed by O-rings compressed under a bolted lid. After loading, dry cask storage systems are located on concrete pads at Independent Spent Fuel Storage Installations (ISFSI) at nuclear power plant sites and will remain there until the time when they will be transported to a consolidated interim storage facility or a deep geologic repository. Eventual transportation of canistered SNF will include removing the stainless steel canisters from the concrete overpacks, possibly repackaging the SNF, and loading the canisters into specially designed transportation casks for shipment by truck, rail, or barge. In the case of the non-canistered casks, some are approved for transportation and can be shipped after impact limiters are installed on the casks. SNF will need to be removed from casks not approved for transportation and transferred to transport-approved casks. This paper highlights five issues and challenges presented by the nuclear industry's use of dry cask storage systems that will need to be addressed by DOE in developing an integrated waste management system. One example, among the five, is that several dry-storage casks and canisters have received Nuclear Regulatory Commission certificates of compliance for storage only and do not have certificates of compliance for transportation. This will pose a challenge when the SNF must be moved to a consolidated interim storage facility or a deep geologic repository. Another example is that, when loaded with SNF, the total weight of new, larger transportation cask designs will exceed 142 metric tonnes (156 tons) which, when combined with the weight of the rail-car, will exceed the gross weight limit for unrestricted operation on some rail lines. This will also affect future transportation planning for shipments of SNF. All five issues and challenges are discussed in detail in the body of the paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mobile multiple access study

Multiple access techniques (FDMA, CDMA, TDMA) for the mobile user and attempts to identify the current best technique are discussed. Traffic loading is considered as well as voice and data modulation and spacecraft and system design. Emphasis is placed on developing mobile terminal cost estimates for the selected design. In addition, design examples are presented for the alternative techniques of multiple access in order to compare with the selected technique.

Source record↗

A large motion zero-gravity suspension system for experimental simulation of orbital construction and deployment

The design and implementation of a vertical degree of freedom suspension system is described which provides a constant force off-load condition to counter gravity over large displacements. By accommodating motions up to one meter for structures weighing up to 100 pounds, the system is useful for experiments which simulate orbital construction events such as docking, multiple component assembly, or structural deployment. A unique aspect of this device is the combination of a large stroke passive off-load device augmented by electromotive torque actuated force feedback. The active force feedback has the effect of reducing break-away friction by a factor of twenty over the passive system alone. The thesis describes the development of the suspension hardware and the control algorithm. Experiments were performed to verify the suspensions system's effectiveness in providing a gravity off-load and simulating the motion of a structure in orbit. Additionally, a three dimensional system concept is presented as an extension of the one dimensional suspension system which was implemented.

Straube, Timothy Milton↗

Power Quality and Stability in a Cluster of Microgrids with Coordinated Power and Energy Management

Distributed Energy Resources (DER) such as photovoltaic (PV) systems and battery energy storage systems (BESS) can be operated collectively as microgrids. Microgrids can be effective in meeting local load requirements as well as in improving the power quality and stability in a modern power distribution system. Multiple microgrids can also be operated in a coordinated manner as a cluster, to improve the resiliency of the power distribution system. In the event of an outage caused by a transmission system failure, the microgrids in a cluster can use their distributed generation capacity and energy storage resources to recover and extend power availability to the critical loads in the system. In this paper, an illustrative cluster of two microgrids based on the IEEE 13-bus model with DERs has been used, to demonstrate the operation of the concept using real-time simulations. Using real-time simulations, capabilities such as switching reconfiguration following faults, identification of optimal DER placement for effective power quality management, and power electronic controller validation have been demonstrated. For the two-microgrid cluster, this paper also presents improvements in load voltage quality and

Chowdhury, Prithwiraj Roy↗

Measuring Flexibility through Reduction Potential

As electrical loads, electric vehicles (EVs) are distinguished in many cases by their substantial flexibility. Harnessing this flexibility, however, requires a precise characterization of its timing and degree. Current approaches to flexibility characterization tend to be limited either by the complexity of their representation or their inability to capture aggregate flexibility across multiple vehicles. In this paper, we present the reduction potential matrix, a novel metric capturing fleet-level EV load flexibility while being both straightforward to calculate and intuitive to interpret. We use the metric to quantify flexibility for two operationally distinct commercial groups: freight vehicles and transit buses. While we find that both vehicle groups have substantial flexibility, its timing, magnitude, and duration varies across the groups. We describe how this variability translates into variation in the each group's role as a grid resource, and conclude with a discussion of how system planners, fleet operators, and other stakeholders can use the novel metric to cultivate symbiosis between vehicles and the grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Within-host infectious disease models accommodating cellular coinfection, with an application to influenza

Within-host models are useful tools for understanding the processes regulating viral load dynamics. While existing models have considered a wide range of within-host processes, at their core these models have shown remarkable structural similarity. Specifically, the structure of these models generally consider target cells to be either uninfected or infected, with the possibility of accommodating further resolution (e.g. cells that are in an eclipse phase). Recent findings, however, indicate that cellular coinfection is the norm rather than the exception for many viral infectious diseases, and that cells with high multiplicity of infection are present over at least some duration of an infection. The reality of these cellular coinfection dynamics is not accommodated in current within-host models although it may be critical for understanding within-host dynamics. This is particularly the case if multiplicity of infection impacts infected cell phenotypes such as their death rate and their viral production rates. Here, we present a new class of within-host disease models that allow for cellular coinfection in a scalable manner by retaining the low-dimensionality that is a desirable feature of many current within-host models. The models we propose adopt the general structure of epidemiological ‘macroparasite’ models that allow hosts to be variably infected by parasites such as nematodes and host phenotypes to flexibly depend on parasite burden. Specifically, our within-host models consider target cells as ‘hosts’ and viral particles as ‘macroparasites’, and allow viral output and infected cell lifespans, among other phenotypes, to depend on a cell’s multiplicity of infection. We show with an application to influenza that these models can be statistically fit to viral load and other within-host data, and demonstrate using model selection approaches that they have the ability to outperform traditional within-host viral dynamic models. Important in vivo quantities such as the mean multiplicity of cellular infection and time-evolving reassortant frequencies can also be quantified in a straightforward manner once these macroparasite models have been parameterized. The within-host model structure we develop here provides a mathematical way forward to address questions related to the roles of cellular coinfection, collective viral interactions, and viral complementation in within-host viral dynamics and evolution.

59 BASIC BIOLOGICAL SCIENCES↗

Improving the economics of battery storage for industrial customers: Are incentives enough to increase adoption?

As adoption of behind-the-meter battery energy storage increases across the United States, implementation continues to lag in the industrial sector. This analysis considers two manufacturing facilities with potential for load shifting to reduce peak demand. Although both facilities have load profiles that demonstrate great potential for regular and programmed demand reduction during peak hours, battery energy storage was deemed prohibitively expensive. A review of several existing utility and state-level policies and incentives determined that few may be rightsized for the industrial customer class. Furthermore, this analysis further considers multiple incentive structures and finds that although incentives increase viability of energy storage, developers must also consider optimization, unique load profiles, and use case to effectively increase adoption of battery energy storage by industrial customers.