Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

The Chemistry of Separations Ligand Degradation by Organic Radical Cations

Solvent based extractions of used nuclear fuel use designer ligands in an organic phase extracting ligand complexed metal ions from an acidic aqueous phase. These extractions will be performed in highly radioactive environments, and the radiation chemistry of all these complexants and their diluents will play a major role in determining extraction efficiency, separation factors, and solvent-recycle longevity. Although there has been considerable effort in investigating ligand damage occurring in acidic water radiolysis conditions, only minimal fundamental kinetic and mechanistic data has been reported for the degradation of extraction ligands in the organic phase. Extraction solvent phases typically use normal alkanes such as dodecane, TPH, and kerosene as diluents. The radiolysis of such diluents produce a mixture of radical cations (R •+ ), carbon-centered radicals (R • ), solvated electrons, and molecular products such as hydrogen. Typically, the radical species will preferentially react with the dissolved oxygen present to produce relatively inert peroxyl radicals. This isolates the alkane radical cation species, R •+ as the major radiolytically-induced organic species that can react with, and degrade, extraction agents in this phase. Here we report on our recent studies of organic radical cation reactions with various ligands. Elucidating these parameters, and combining them with the known acidic aqueous phase chemistry, will allow a full, fundamental, understanding of the impact of radiation on solvent extraction based separation processes to be achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Widespread Dependence of Backup NHEJ on Growth State: Ramifications for the Use of DNA-PK Inhibitors

Purpose: The backup pathway of nonhomologous end joining (B-NHEJ) enables cells to process DNA double-strand breaks (DSBs) when the DNA-PK-dependent pathway of NHEJ (D-NHEJ) is compromised. Our previous results show marked reduction in the activity of B-NHEJ when LIG4{sup -/-} mouse embryo fibroblasts (MEFs) cease to grow and enter a plateau phase. The dependence of B-NHEJ on growth state is substantially stronger than that of D-NHEJ and points to regulatory mechanisms or processing determinants that require elucidation. Because the different D-NHEJ mutants show phenotypes distinct in their details, it is necessary to characterize the dependence of their DSB repair capacity on growth state and to explore species-specific responses. Methods and Materials: DSB repair was measured in cells of different genetic background from various species using pulsed-field gel electrophoresis, or the formation of {gamma}-H2AX foci, at different stages of growth. Results: Using pulsed-field gel electrophoresis, we report a marked reduction of B-NHEJ during the plateau phase of growth in KU and XRCC4, mouse or Chinese hamster, mutants. Notably, this reduction is only marginal in DNA-PKcs-deficient cells. However, reduced B-NHEJ is also observed in repair proficient, plateau-phase cells after treatment with DNA-PK inhibitors. The reduction of B-NHEJ activity in the plateau phase of growth does not derive from the reduced expression of participating proteins, is detectable by {gamma}-H2AX foci analysis, and leads to enhanced cell killing. Conclusions: These results further document the marked dependence on growth state of an essential DSB repair pathway and show the general nature of the effect. Molecular characterization of the mechanism underlying this response will help to optimize the administration of DNA repair inhibitors as adjuvants in radiation therapy.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Correlating armature and needle dynamics with voltage waveforms of solenoid-actuated GDI injector

The injector voltage hump that appears near the needle closing has been used for the real-time monitoring and feedback control of fuel injection duration in modern engines. This voltage hump has been thought to result from the abrupt change in electromagnetic induction by the stoppage of needle motion but detailed electromagnetic processes and associated armature and needle dynamics during the needle closing have not been thoroughly investigated in a wide range of injection conditions, which knowledge is crucial for the delicate control of fuel injection based on the voltage hump. Here, the current study analyzes the transient armature and needle dynamics of a solenoid-actuated gasoline direct injection injector using an X-ray phase-contrast imaging technique. Then, the results are correlated with voltage waveforms during the needle closing transient under various injection pressures, injection pulse durations, and dwell times of split injections. The time derivatives of voltage waveforms showed lower and upper peaks in order in the regime of the voltage hump. Inconsistent with conventional understandings, the lower peak timing of the voltage derivative did not match with the timing of needle closing (end of injection) but rather matched with the abrupt descent timing of the armature and needle. The inflection timing and upper peak timing of the voltage derivative matched with the timings of actual needle closing and armature closing respectively. The amplitude of the voltage hump was near linearly dependent on the needle closing speed. The needle closing speed decreased upon the decrease of injection pulse duration and injection pressure which made it difficult to detect the voltage humps in ballistic injection regimes and low injection pressures. In split injection conditions, the voltage hump of the first injection was not detectable if the dwell time was shorter than the needle closing delay, the time from the current cut-off to the actual needle closing.

42 ENGINEERING↗

ADC Nonlinearity Correction for the Majorana Demonstrator

Imperfections in analog-to-digital conversion cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the MAJORANA DEMONSTRATOR 76 Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. Here, a simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterated Xylene-Based Neutron Spectrometry

Deuterated scintillators, such as deuterated xylene (C8D10) have been theorized to offer better pulse shape discrimination (PSD) and neutron spectrometry performance than traditional protiated scintillators due to the anisotropy of neutron scattering on deuterium. However, the light output responses of said deuterated scintillators to monoenergetic has not been characterized in its entirety at both high and low energies. Several time-of-flight experiments were conducted at the Idaho national Laboratory to characterize a pair of EJ-301D deuterated xylene detectors. The low energy detector response to quasi-monoenergetic neutrons was measured using a Cf-252 source, and the high energy detector response was measured using a D-T source and angles of 20, 45, and 60 deg, corresponding to theoretical neutron energies of 13.2, 10.4, and 8.2 MeV. During post-processing, the neutron and gamma bands were clearly able to be separated, even at low light outputs, solidifying the superior PSD capability of deuterated xylene. An exponential of fit of LO=0.63E-2.22*(1-exp(-0.25E)), which has good agreement with previously measured data, was found as the light output response from deuteron recoils. Additionally, measurements of AmBe, D-T, and D-D sources were unfolded using the light output response curve, which resulted in favorable agreement with theoretical values. Further testing of the response matrix by unfolding more sources (such as PuBe) needs to be done, but the unfolding accuracy for currently available sources suggests that deuterated xylene can be used to measure and unfold both fission, monoenergetic, and continuous spectra.

scintillator↗

Methods for diagnosing and quantifying double pulsing in a Uranium Neutron Collar system using shift register logic

Double pulsing in neutron coincidence counters is the result of a pulse processing chain-3He proportional counter timing incompatibility known to nondestructive assay system designers. It is not currently widely acknowledged, or accounted for, in the user community. However, it is gaining attention as list mode data acquisition and analysis becomes more commonly used for system diagnostics, revealing features that have been overlooked by historic timing gate selection using traditional shift register data acquisition methods. Double pulsing increases the apparent number of measured neutron events from a source. Therefore, it may contribute to a falsely increased count rate if present at the operational high voltage used when assaying samples, even with set predelays. The authors have previously studied the effects of double pulsing, using list mode data acquisition and analysis on neutron pulse trains in three common neutron coincidence counting systems used in routine measurements for international safeguards: a Canberra Industries JCC-71 Neutron Coincidence Collar, a variant on the Canberra Industries JCC-51 Active Well Neutron Coincidence Counter (the Large Volume Active Well Neutron Coincidence Counter), and an AnTech Inc. N2071 Neutron Coincidence Collar. We find that this non-ideal behavior was isolated to the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip used in both the Canberra Industries and Antech systems. The double pulsing fraction was calculated in post-analysis for various high voltage settings in these A111-based systems, assuming no predelay settings. In this work, the authors expand upon this identification and analysis to make it more translatable between list mode data acquisition and analysis and shift register-based analysis. By investigating the double pulsing fractions in a JCC-71 Uranium Neutron Collar as a function of predelay settings, as well as describing and performing alternative tests and analyses to diagnose and quantify the double pulsing using shift register logic, this work hopes to complete the picture of double pulsing identification and analysis.

Safeguards↗

Neutron-neutron angular correlations in spontaneous fission of Cf 252 and Pu 240

Background: Angular anisotropy has been observed between prompt neutrons emitted during the fission process. Such an anisotropy arises because the emitted neutrons are boosted along the direction of the parent fragment. Purpose: To measure the neutron-neutron angular correlations from the spontaneous fission of 252 Cf and 240 Pu oxide samples using a liquid scintillator array capable of pulse-shape discrimination. To compare these correlations to simulations combining the Monte Carlo radiation transport code MCNPX with the fission event generator FREYA. Method: Two different analysis methods were used to study the neutron-neutron correlations with varying energy thresholds. The first is based on setting a light output threshold while the second imposes a time-of-flight cutoff. The second method has the advantage of being truly detector independent. Results: The neutron-neutron correlation modeled by FREYA depends strongly on the sharing of the excitation energy between the two fragments. The measured asymmetry enabled us to adjust the FREYA parameter x in 240 Pu , which controls the energy partition between the fragments and is so far inaccessible in other measurements. The 240 Pu data in this analysis was the first available to quantify the energy partition for this isotope. The agreement between data and simulation is overall very good for 252 Cf ( sf ) and 240 Pu ( sf ). Conclusions: The asymmetry in the measured neutron-neutron angular distributions can be predicted by FREYA. The shape of the correlation function depends on how the excitation energy is partitioned between the two fission fragments. Lastly, experimental data suggest that the lighter fragment is disproportionately excited.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Training courses on neutron detection systems on the ISIS research reactor: on-site and through internet training

Today, ISIS research reactor is an essential tool for Education and Training programs organized by the National Institute for Nuclear Science and Technology (INSTN) from CEA. In the field of nuclear instrumentation, the INSTN offers both, theoretical courses and training courses on the use of neutron detection systems taking advantage of the ISIS research reactor for the supply of a wide range of neutron fluxes. This paper describes the content of the training carried out on the use of neutron detectors and detection systems, on-site or remote. The ISIS reactor is a 700 kW open core pool type reactor. The facility is very flexible since neutron detectors can be inserted into the core or its vicinity, and be used at different levels of power according to the needs of the course. Neutron fluxes, typically ranging from 1 to 10{sup 12} n/cm{sup 2}.s, can be obtained for the characterisation of the neutron detectors and detection systems. For the monitoring of the neutron density at low level of power, the Instrumentation and Control (I and C) system of the reactor is equipped with two detection systems, named BN1 and BN2. Each way contains a fission chamber, type CFUL01, connected to an electronic system type SIREX.The system works in pulse mode and exhibits two outputs: the counting rate and the doubling time. For the high level of power, the I and C is equipped with two detection systems HN1 and HN2.Each way contain a boron ionization chamber (type CC52) connected to an electronics system type SIREX. The system works in current mode and has two outputs: the current and the doubling time. For each mode, the trainees can observe and measure the signal at the different stages of the electronic system, with an oscilloscope. They can understand the role of each component of the detection system: detector, cable and each electronic block. The limitation of the detection modes and their operating range can be established from the measured signal. The trainees can also modify the settings of the electronic system, such as the high voltage and the discrimination level in order to obtain all the characteristic curves of the detectors. These curves are used to define the right setting of the electronic system and to discuss the expected degradation of the detector signal resulting from the detector damage under the integrated neutron and gamma fluxes. Moreover, in addition to the study of the neutron detection systems itself, the integration of the measurements made by these detection systems in the logic of the safety system of the nuclear reactor is also addressed. Providing the trainees with an extensive overview of each part of the neutron monitoring instrumentation apply to a nuclear reactor, hands-on measurements on the ISIS reactor play a major role in ensuring a practical and comprehensive understanding of the neutron detection system and their integration in the safety system of nuclear reactors. It also gives a solid background for the follow up and the development of the neutron detection systems. In addition to on-reactor training, Internet Reactor Laboratory capability has been implemented on the ISIS reactor in 2014. For the Internet Reactor Laboratory an extensive video conference system has been implemented on ISIS reactor. The system includes 4 cameras and the transmission of the video signal given by the supervision system of the reactor which records and processes the data of the reactor. According to the pedagogic needs during the training courses, the lecturer on the ISIS reactor chooses to broadcast the relevant information at each stage of the course. For example, graph showing the histogram of the counting and current as a function of the time, or the electrical signal observed on the oscilloscope, can be broadcasted trough internet. By interacting through the video conference, the remote classroom is able to ask for changes in the reactor power or settings of the detection systems. They can also ask for the broadcast of some particular information. At the guest institution, the information is displayed in two parts or screens, as shown in the Figure 3. Concerning the interaction with - and the feedback from - the remote classroom, the camera of the video system in the remote classroom is used to ensure the contact between the trainees and the lecturer and reactor operators. Thus, the Internet Reactor Laboratory is complementary to the on reactor training courses. It allows distant learning, reducing the overall cost of the course when this is necessary. It can efficiently be used for the development of the human resources needed by the nuclear industry and the nuclear programs in countries without research reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Adsorption calorimetry during metal vapor deposition on single crystal surfaces: Increased flux, reduced optical radiation, and real-time flux and reflectivity measurements

Thin films of metals and other materials are often grown by physical vapor deposition. To understand such processes, it is desirable to measure the adsorption energy of the deposited species as the film grows, especially when grown on single crystal substrates where the structure of the adsorbed species, evolving interface, and thin film are more homogeneous and well-defined in structure. Our group previously described in this journal an adsorption calorimeter capable of such measurements on single-crystal surfaces under the clean conditions of ultrahigh vacuum [J. T. Stuckless, N. A. Frei, and C. T. Campbell, Rev. Sci. Instrum. 69, 2427 (1998)]. Here we describe several improvements to that original design that allow for heat measurements with ∼18-fold smaller standard deviation, greater absolute accuracy in energy calibration, and, most importantly, measurements of the adsorption of lower vapor-pressure materials which would have previously been impossible. These improvements are accomplished by: (1) using an electron beam evaporator instead of a Knudsen cell to generate the metal vapor at the source of the pulsed atomic beam, (2) changing the atomic beam design to decrease the relative amount of optical radiation that accompanies evaporation, (3) adding an off-axis quartz crystal microbalance for real-time measurement of the flux of the atomic beam during calorimetry experiments, and (4) adding capabilities for in situ relative diffuse optical reflectivity determinations (necessary for heat signal calibration). These improvements are not limited to adsorption calorimetry during metal deposition, but also could be applied to better study film growth of other elements and even molecular adsorbates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spark Channel Dynamics of Electrostatic Discharges

When two differently-charged objects are brought in close proximity to each other, the resulting high electric fields can cause electron avalanche breakdown of the air gap separating the objects, a process known as electrostatic discharge (ESD). If enough initial charge is stored on the objects, the electrical breakdown can proceed to ionize the air to such a degree that a highly conductive filament of plasma forms in the gap, known as a spark channel. The spark electrically bridges the air gap, resulting in a rapid pulse of current that neutralizes the charge difference. The current pulse produces significant heating of the gas in the spark, resulting in dissociation, ionization, thermal radiation, and hydrodynamic expansion. ESD presents a hazard to electrically-sensitive devices, with consequences such as economic losses (e.g. damaged electronics) or unsafe response (e.g. unintended ignition of flammable gas mixtures, initiation of detonators, etc.). For this thesis, the ESD spark is taken to occur between two conducting electrodes, with the spark channel being axisymmetric in a cylindrical coordinate system centered on the channel. An RLC-type circuit is used for the discharge model of the ESD event. The spark is treated as a time-dependent resistance that is in series with a capacitance, an inductance, and (optionally) a load resistance representing a “victim” component under threat from the ESD event. The primary motivation of this work is to use a numerical hydrodynamic model to understand the energy dissipation and transport processes in the spark. The model consists of the compressible Euler equations of mass, momentum, and energy conservation together with an Eddington/P1 approximation for thermal radiation transport. To close the hydrodynamic system, an equation of state (EOS) was fitted from tabular data for air that accounts for the dissociation and ionization of air species. The hydrodynamic equations are solved using a conservative Lagrangian finite volume method. These partial differential equations are coupled to the circuit equations by calculation of the spark resistance via numerical integration of the electrical conductivity of the channel. Computational results are compared against experimental measurements of discharge current and radial density of the spark channel.

42 ENGINEERING↗

Basic Energy Sciences Roundtable: Opportunities for Basic Research at the Frontiers of XFEL Ultrafast Science

Advances in science and technology over the past century have been driven by an improved understanding of matter on ultrashort length scales, reaching down to atomic dimensions. In contrast, methods aimed at understanding dynamics on the ultrafast time scales of atomic motion are comparatively new. Ultrafast characterization has already yielded crucial insights not attainable from slower measurements. The interplay between atomic-scale structure and the associated ultrafast dynamics governs the macroscopic functionality observed in matter. Understanding and controlling materials and chemical processes at these length and time scales are key to discovery and innovation to advance energy and related national priorities. The recent availability of x-ray free-electron lasers (XFELs) provides a probe that simultaneously reaches the required resolution in both space and time. X-ray wavelengths extend down to the atomic scale, while x-ray pulse durations now lie in the femtosecond (10 -15 seconds) range. This capability allows the evolution of materials and chemical processes to be followed on their natural time and length scales, providing fundamental scientific understanding of the complexity of the world around us. Because of the transformative potential of new ultrafast x-ray characterization tools provided by XFELs, it is imperative to lay out a roadmap for the exciting scientific opportunities that can be explored using these research tools. To identify the highest priority research opportunities, the U.S. Department of Energy Office of Basic Energy Sciences (BES) convened a roundtable of experts in chemistry, materials physics, and ultrafast and x-ray science. This group of experimentalists and theorists met on October 25–26, 2017 to explore research opportunities that will leverage current and imminent ultrafast XFEL capabilities and advance the broader BES science mission. This report summarizes major new scientific frontiers that can be addressed by emerging XFEL capabilities. The conclusions of the roundtable discussion are summarized in the following three Priority Research Opportunities (PROs).

36 MATERIALS SCIENCE↗

Presentation to JAEA Visitors, July 24, 2012 [Slides]

There are 7 Reasons for characterizing spent fuel nuclide concentrations: (1) Provide IAEA with the capability to independently verify the mass of plutonium at any site that has spent fuel; (2) Shipper/receiver difference; (3) Determination of the input accountability mass of an electrochemical (pyro-chemical) processing facility; (4) Continuity of knowledge at spent fuel storage site; (5) Optimal reloads through knowledge of true actinide content; (6) Burnup credit for fuel transport and storage; and (7) Provide confidence to the public that the shipment of spent fuel around the world is being undertaken in a rigorous manner, assuring that material is not diverted during shipment. Types of fuel of interest are: Fast Reactor Fuel, Normal burnup low enriched uranium (LEU), Mixed oxide (MOX), Low burnup LEU, and Research reactor. MCNPX calculates the slowing down and the energy spread for a given time. The principles are: (1) Neutrons slow down in LSDS; (2) Slow neutrons capture preferentially on a fission resonance; (3) Fission emits high-energy neutrons; (4) High-energy neutrons detected in threshold detector (that is not sensitive to slow neutrons) (e.g., 238 U, 232 Th); and (5) The detection time is characteristic of the slow neutron energy. Following each PSR pulse, the entire signal is digitized in 2 nanosecond intervals, and subsequently analyzed Analysis involves applying a digital filter to extract fission pulses in a background of initial oscillations and noise throughout. Some of the noise is not random. Depending on the threshold setting and filter parameters, both the normalization and the trend change. Original PNNL LSDS design required a 1-meter radius cylindrical LSDS. Much higher efficiency would allow us to use a (1.2m) LSDS (this is the LANL LSDS size), or a less intense source, or a combination of both. We still estimate 10 16 total neutrons from the source to obtain 2-3% precision in 239 Pu and 235 U assay.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HSQC spectra of lignin isolated from poplar roots

Here we present a curated dataset of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from roots of a greenhouse grown natural population of an energy crop poplar (Populus trichocarpa). Dormant cuttings of field-grown poplar were grown in 6-liter pots in a peat-based media containing bark, perlite, vermiculite, dolomite lime and a wetting agent in an environmentally controlled greenhouse. Temperatures were between 21 and 23 °C, with supplemental lighting to support a 16-h day length using 1000-watt high-pressure sodium lights in greenhouse. Once established, all plants were cut-back, allowed to regrow and harvested at the same time following an eight-month long growth period. Plants were harvested and the belowground roots were washed off soils, blotted, dried in an oven at 70 °C for 3 days, and Wiley milled (mesh size 20). The roots were Soxhlet-extracted with toluene/ethanol for 24 h to remove extractives. The extracted roots were ball-milled in a Retsch PM100 planetary ball mill using a porcelain jar with ceramic balls at 600 rpm for 2 h (in 5 min on and 5 min off cycles to avoid excessive sample heating). The ball-milled materials were then subjected to enzymatic hydrolysis for 48 h followed by centrifugation and washing with deionized water. The solid residue was extracted twice with 96% (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover lignin. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide (d6) and transferred into a 5 mm tube. 13C–1H HSQC experiments were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus using a standard Bruker pulse sequence on a Prodigy platform cryoprobe. The NMR spectra were acquired under the following acquisition conditions: 220 ppm spectral width in F1 (13C) dimension with 256 data points and 12 ppm spectral width in F2 (1H) dimension with 1024 data points, a 90° pulse, a one bond C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. Spectra were processed using the Bruker TopSpin software. Additional meta data is embedded in the raw spectra figures.

HSQC, lignin, poplar, roots, CBI↗

Measurements of fusion reaction history in inertially confined burning plasmas

Direct evidence of inertially confined fusion ignition appears in the abrupt temperature increase and consequent rapid increase in the thermonuclear burn rate as seen in the reaction history. The Gamma Reaction History (GRH) and Gas Cherenkov Detector (GCD) diagnostics are γ-based Cherenkov detectors that provide high quality measurements of deuterium–tritium fusion γ ray production and are, thus, capable of monitoring the thermonuclear burn rate. Temporal shifts in both peak burn time and burn width have been observed during recent high-yield shots (yields greater than 1017 neutrons) and are essential diagnostic signatures of the ignition process. While the current GRH and GCD detectors are fast enough to sense the changes of reaction history due to alpha heating, they do not have enough dynamic range to capture the onset of alpha heating. The next generation of instrumentation, GRH-15m, is proposed to increase the yield-rate coverage to measure the onset of alpha-heating.

42 ENGINEERING↗

Full-Scale Vessel Testing for the Hanford Waste Treatment and Immobilization Plant - 18333

Concerns over the mixing performance of the planned pulse jet mixed (PJM) vessels for high-solids applications in the Hanford Waste Treatment and Immobilization Plant (WTP) Pretreatment (PT) Facility, led to the development of a standard high-solids vessel (SHSV) design and full-scale vessel testing program. The SHSV is intended as a potential replacement for several high-level waste feed receipt and lag storage vessels (High-Level Waste Facility lag storage and feed blending process), ultrafiltration feed preparation vessels (ultrafiltration process system), and plant wash vessels (plant wash and disposal system). The SHSV concept uses multiple smaller vessels (60 500 L - 79 500 L nominal batch size) to replace larger vessels, providing redundancy, improved mixing (PJM design and spargers), monitoring (multi-level bubblers), reduced material at risk, and improved structural features. The SHSV also requires qualification of a single vessel design for high solids Newtonian and non-Newtonian slurry processing, rather than having to qualify earlier multiple vessel designs. An Integrated Technical Team consisting of the U.S. Department of Energy, Bechtel National, Inc., and independent experts was established to accelerate and provide oversight and direction of the test program and SHSV qualification. Qualification of the SHSV for mixing has now been achieved through a comprehensive full-scale vessel testing program conducted in 2017 with a prototypic SHSV under a set of most adverse design conditions, in conjunction with additional engineering analyses. This paper will present an overview of the SHSV, results from the three-phase full-scale vessel test and qualification program completed in September 2017, and the management program to achieve resolution of the PJM mixing technical issue. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The JSNS 2 detector

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV 2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this study, we describe the JSNS detector design, construction, and operation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Abel Inversion in Quantitative X-Ray Radiography

A common image formation process in high-energy X-ray radiography is to have a pulsed power source that emits X-rays through a scene, a scintillator that absorbs X-rays and uoresces in the visible spectrum in response to the absorbed photons, and a CCD camera that images the visible light emitted from the scintillator. The intensity image is related to areal density, and, for an object that is radially symmetric about a central axis, the Abel transform then gives the object's volumetric density. Two of the primary drawbacks to classical variational methods for Abel inversion are their sensitivity to the type and scale of regularization chosen and the lack of natural methods for quantifying the uncertainties associated with the reconstructions. In this work we cast the Abel inversion problem within a statistical framework in order to compute volumetric object densities from X-ray radiographs and to quantify uncertainties in the reconstruction. A hierarchical Bayesian model is developed with a likelihood based on a Gaussian noise model and with priors placed on the unknown density pro le, the data precision matrix, and two scale parameters. This allows the data to drive the localization of features in the reconstruction and results in a joint posterior distribution for the unknown density pro le, the prior parameters, and the spatial structure of the precision matrix. Results of the density reconstructions and pointwise uncertainty estimates are presented for both synthetic signals and real data from a U.S. Department of Energy X-ray imaging facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure and ultrafast dynamics of tri-nuclear Ag-/Tl–Pt 2 POP 4 complexes in solution

The energetics and dynamics of ion assembly in solution has broad influence in nanomaterials and inorganic synthesis. To investigate the fundamental processes involved, we present a time-resolved x-ray solution scattering (TR-XSS) study of the trinuclear silver and thallium complexes of the diplatinum ion PtPOP [Pt 2 (H 2 P 2 O 5 )$_4^{4−}$] in aqueous solution. These complexes, their structural properties, and their electronic structure are not well understood and afford a unique opportunity to study the metal–metal bond formation that influences molecular and material assembly in solution. We present model-independent analysis of the observed dynamics as well as an analysis incorporating time-resolved structural refinements of key bond lengths with $<$100 fs time resolution. We find that upon photoexcitation, the Pt atoms contract ∼0.25 Å toward the center of both the Ag- and the Tl-PtPOP complexes, as previously observed for the PtPOP anion. For the AgPtPOP system, an ultrafast Ag-Pt bond expansion of ∼0.2 Å is observed, whereas in contrast, the TlPtPOP system exhibits a Tl-Pt bond contraction of ∼0.3 Å upon photoexcitation. For both complexes, the change in electronic state leads to coherent (“wave-packet”) oscillations along the metal–Pt coordinates. Based on these structural dynamics, we propose an electronic structure model that describes the metal–metal bonding behavior in both the ground and excited state for both complexes.

Lenzen, Philipp [Technical Univ. of Denmark, Lyngb↗