Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Membrane Vibration Analysis Above the Nyquist Limit with Fluorescence Videogrammetry

A new method for generating photogrammetric targets by projecting an array of laser beams onto a membrane doped with fluorescent laser dye has recently been developed. In this paper we review this new fluorescence based technique, then proceed to show how it can be used for dynamic measurements, and how a short pulsed (10 ns) laser allows the measurement of vibration modes at frequencies several times the sampling frequency. In addition, we present experimental results showing the determination of fundamental and harmonic vibration modes of a drum style dye-doped polymer membrane tautly mounted on a 12-inch circular hoop and excited with 30 Hz and 62 Hz sinusoidal acoustic waves. The projected laser dot pattern was generated by passing the beam from a pulsed Nd:YAG laser though a diffractive optical element, and the resulting fluorescence was imaged with three digital video cameras, all of which were synchronized with a pulse and delay generator. Although the video cameras are capable of 240 Hz frame rates, the laser s output was limited to 30 Hz and below. Consequently, aliasing techniques were used to allow the measurement of vibration modes up to 186 Hz with a Nyquist limit of less than 15 Hz.

Dorrington, Adrian A.↗

WE-F-16A-02: Design, Fabrication, and Validation of a 3D-Printed Proton Filter for Range Spreading

Purpose: To design, fabricate and test a 3D-printed filter for proton range spreading in scanned proton beams. The narrow Bragg peak in lower-energy synchrotron-based scanned proton beams can result in longer treatment times for shallow targets due to energy switching time and plan quality degradation due to minimum monitor unit limitations. A filter with variable thicknesses patterned on the same scale as the beam's lateral spot size will widen the Bragg peak. Methods: The filter consists of pyramids dimensioned to have a Gaussian distribution in thickness. The pyramids are 2.5mm wide at the base, 0.6 mm wide at the peak, 5mm tall, and are repeated in a 2.5mm pseudo-hexagonal lattice. Monte Carlo simulations of the filter in a proton beam were run using TOPAS to assess the change in depth profiles and lateral beam profiles. The prototypes were constrained to a 2.5cm diameter disk to allow for micro-CT imaging of promising prototypes. Three different 3D printers were tested. Depth-doses with and without the prototype filter were then measured in a ~70MeV proton beam using a multilayer ion chamber. Results: The simulation results were consistent with design expectations. Prototypes printed on one printer were clearly unacceptable on visual inspection. Prototypes on a second printer looked acceptable, but the micro-CT image showed unacceptable voids within the pyramids. Prototypes from the third printer appeared acceptable visually and on micro-CT imaging. Depth dose scans using the prototype from the third printer were consistent with simulation results. Bragg peak width increased by about 3x. Conclusions: A prototype 3D printer pyramid filter for range spreading was successfully designed, fabricated and tested. The filter has greater design flexibility and lower prototyping and production costs compared to traditional ridge filters. Printer and material selection played a large role in the successful development of the filter.

07 ISOTOPE AND RADIATION SOURCES↗

Comment on Sub-15 nm Hard X-Ray Focusing with a New Total-Reflection Zone Plate

Takano et al. report the focusing of 10-keV X-rays to a size of 14.4 nm using a total-reflection zone plate (TRZP). This focal size is at the diffraction limit for the optic's aperture. This would be a noteworthy result, since the TRZP was fabricated using conventional lithography techniques. Alternative nanofocusing optics require more demanding fabrication methods. However, as I will discuss in this Comment, the intensity distribution presented by Takano et al. (Fig. 4 of ref. 1) is more consistent with the random speckle pattern produced by the scattering of a coherent incident beam by a distorted optic than with a diffraction-limited focus. When interpreted in this manner, the true focal spot size is {approx}70 nm: 5 times the diffraction limit. When a coherent photon beam illuminates an optic containing randomly distributed regions which introduce different phase shifts, the scattered diffraction pattern consists of a speckle pattern. Each speckle will be diffraction-limited: the peak width of a single speckle depends entirely on the source coherence and gives no information about the optic. The envelope of the speckle distribution corresponds to the focal spot which would be observed using incoherent illumination. The width of this envelope is due to the finite size of the coherently-diffracting domains produced by slope and position errors in the optic. The focal intensity distribution in Fig. 4 of ref. 1 indeed contains a diffraction-limited peak, but this peak contains only a fraction of the power in the focused, and forms part of a distribution of sharp peaks with an envelope {approx}70 nm in width, just as expected for a speckle pattern. At the 4mm focal distance, the 70 nm width corresponds to a slope error of 18 {micro}rad. To reach the 14 nm diffraction limit, the slope error must be reduced to 3 {micro}rad. Takano et al. have identified a likely source of this error: warping due to stress as a result of zone deposition. It will be interesting to see whether the use of a more rigid substrate gives improved results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam Shaping and Oscillation for Metals Additive Manufacturing

Additive Manufacturing (AM) is pivotal for next-generation industrial manufacturing but is hampered by process control challenges leading to unwanted defects and sub-optimal material properties. Our research builds on prior work that utilized beam oscillation techniques to mitigate these issues (Wu et al., 2023). We focus on investigating the influence of beam oscillation frequency on melt pool dynamics, utilizing in-situ synchrotron material characterization from the ESRF (Chen et al., 2026). Preliminary findings indicated that beam oscillation results in unique fluid flow patterns and enhanced melting stability. These findings suggested the possibility of optimized AM process control, including minimized defects and tailored thermal histories. We proposed further research to explore the effects of beam oscillation frequencies comprehensively, using the in-situ characterization capabilities at the ESRF. The goal was to quantify this relationship, offering a pathway to more precise AM process control and optimization. Our research is expected to offer new scientific insights into the fluid mechanics and thermal behaviour in AM, contributing to its broader applicability and commercial viability.

36 MATERIALS SCIENCE↗

Variable voltage electron microscopy: Toward atom-by-atom fabrication in 2D materials

The precisely focused electron beam (e-beam) in scanning transmission electron microscopy has been found to be a versatile tool for patterning matter on the atomic level and enabling atom-by-atom fabrication, however, beam-induced phenomena are known to be extremely sensitive to the e-beam energy and are closely correlated with the proximity of the knock-on threshold. Here we provide a method to control the energy transferred to the sample while facilitating much faster changes in accelerating voltages by maintaining a nearly constant temperature in the electron microscope lenses. We use this method to demonstrate in-situ nano-milling of a graphene film followed rapidly by “gentler” imaging at lower energy. Additionally, the insertion and controlled movement of silicon dopants in graphene is demonstrated by employing a different e-beam energy during each process. We believe the incorporation of variable e-beam energy will broaden the potential for atomic scale e-beam fabrication.

36 MATERIALS SCIENCE↗

A differentiable simulation package for performing inference of synchrotron-radiation-based diagnostics

The direction of particle accelerator development is ever-increasing beam quality, currents and repetition rates. This poses a challenge to traditional diagnostics that directly intercept the beam due to the mutual destruction of both the beam and the diagnostic. An alternative approach is to infer beam parameters non-invasively from the synchrotron radiation emitted in bending magnets. However, inferring the beam distribution from a measured radiation pattern is a complex and computationally expensive task. To address this challenge we present SYRIPY ( SYnchrotron Radiation In PYthon ), a software package intended as a tool for performing inference of synchrotron-radiation-based diagnostics. SYRIPY has been developed using PyTorch , which makes it both differentiable and able to leverage the high performance of GPUs, two vital characteristics for performing statistical inference. The package consists of three modules: a particle tracker, Lienard–Wiechert solver and Fourier optics propagator, allowing start-to-end simulation of synchrotron radiation detection to be carried out. SYRIPY has been benchmarked against SRW , the prevalent numerical package in the field, showing good agreement and up to a 50× speed improvement. Finally, we have demonstrated how SYRIPY can be used to perform Bayesian inference of beam parameters using stochastic variational inference.

43 PARTICLE ACCELERATORS↗

Heat assisted magnetic recording with patterned FePt recording media using a lollipop near field transducer

In heat-assisted magnetic recording, optical energy is transferred to a small optical spot on the recording media using a near field transducer. In this study, a scattered field finite difference time domain simulation is used to analyze the performance of a lollipop transducer in heat assisted magnetic recording on both a patterned FePt media and a continuous thin film. To represent wear, sharp corners of the peg are approximated with curved ones, which are found to narrow the track width without excessive loss of intensity. Compared with continuous media, the patterned media exhibits higher energy efficiency and a better concentrated optical beam spot. This effect is due to the near field effects of patterned media on the performance of the transducer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The corrugated horn as an antenna range standard.

The corrugated horn is discussed as is a valuable tool for use in microwave pattern ranges. It has the properties of concentrated energy in the main beam, low backlobes, high efficiency, almost monotonic amplitude, and phase radiation patterns which make the corrugated horn useful for a source antenna in a pattern range and also as a possible standard antenna for calibration purposes.

Caldecott, R.↗

Analog Phase Holograms by Electron Beam Lithography

Phase holograms have been created on the surface of a thin film of poly-methyl methacrylate (PMMA, Plexiglas) by direct-write electron beam (E-Beam) lithography. The process involves delivering a patterned exposure dose followed by partial development with a strong developer. The patterned dose derives from arbitrary computer-calculated holograms, which must be corrected for the sensitivity characteristic of the PMMA and for the effective point-spread function of the E-Beam.

phase↗

Site-Controlled Growth of GaN Nanorods with Inserted InGaN Quantum Wells on μ-Cone Patterned Sapphire Substrates by Plasma-Assisted MBE

We report on a new approach to fabricate regular arrays of GaN nanorods (NRs) with InGaN QWs by plasma-assisted molecular-beam epitaxy (PA MBE) on micro-cone patterned sapphire substrates (μ-CPSSs). A two-stage PA MBE fabrication process of GaN NRs has been developed, starting with a high temperature nucleation layer growth at metal-rich conditions to aggregate selectively GaN nucleus on c-oriented areas of the μ-CPSSs and followed by growth of 1-μm-thick GaN NRs at strongly nitrogen-rich conditions exactly on the cone tips. These results are explained by energetically favorable GaN growth on the (000-) oriented sapphire surface. Both micro-photoluminescence and micro-cathodoluminescence confirm the formation of regular array of optically and spectrally isolated NRs without usage of any nanolithography.

36 MATERIALS SCIENCE↗

Patterns of Relapse in High-Risk Neuroblastoma Patients Treated With and Without Total Body Irradiation

Purpose: External beam radiation therapy to initial sites of disease may influence relapse patterns in high-risk neuroblastoma. However, the effect of systemic irradiation by use of total body irradiation (TBI) on anatomic patterns of relapse has not previously been investigated. Methods and Materials: We retrospectively analyzed patients receiving definitive treatment of high-risk neuroblastoma with subsequent relapse in bony metastatic sites, with a date of relapse between January 1, 1997, and December 31, 2012. Anatomic sites of disease, defined by metaiodobenzylguanidine (MIBG) avidity, were compared at diagnosis and at first relapse. The Fisher exact test was performed to compare relapse in initially involved sites between patients treated with and without TBI. Results: Seventy-four patients with a median age at diagnosis of 3.5 years (range, 0.3-15.3 years) had relapse in 227 sites of MIBG-avid metastatic disease, with a median time to relapse of 1.8 years. Of the 227 sites of first relapse, 154 sites (68%) were involved at diagnosis. When we compared relapse patterns in patients treated with and without TBI, 12 of 23 patients (52%) treated with TBI had relapse in ≥1 previously MIBG-avid site of disease whereas 40 of 51 patients (78%) treated without TBI had relapse in ≥1 previously MIBG-avid site of disease (P=.03). Conclusions: Patients treated with systemic irradiation in the form of TBI were significantly less likely to have relapse in prior sites of disease. These findings support further investigation into the role of radiopharmaceutical therapies in curative multimodality therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulated real time image guided intrafraction tracking-delivery for hypofractionated prostate IMRT

Hypofractionated stereotactic body radiotherapy (SBRT) has been tested for prostate cancer radiotherapy. This study aims to investigate the dosimetric effects of intrafraction prostate motion on the target and the normal structures for SBRT. For prostate cancer patients treated with an image-tracking CyberKnife system, the intrafraction prostate movements were recorded during 50-70 min treatment time. Based on the recorded intrafraction prostate movements, treatment plans were created for these cases using intensity modulated beams while scaling the average time patterns from the CyberKnife treatment to simulate hypofractionated intensity modulated radiotherapy (IMRT) delivery. The effect of delivery time on the intrafraction organ motion was investigated. For a nominal single fraction delivery of 9.5 Gy with IMRT, we found that the dosimetric effect of the intrafraction prostate movement is case dependent. For most cases, the dose volume histograms exhibited very small changes from the treatment plans that assumed no intrafractional prostate motion when the maximum intrafraction movements were within {+-}5 mm. However, when sporadic prostate movements greater than 5 mm were present in any one direction, significant changes were found. For example, the V{sub 100%} for the prostate could be reduced by more than 10% to less than 85% of the prostate volume coverage. If these large movements could be excluded by some active correction strategies, then the average V{sub 100%} for the simulated plan could be restored to within approximately 2% of the ideal treatment plans. On average, the sporadic intrafraction motion has less dosimetric impact on the prolonged treatment delivery versus fast treatment delivery. For example, the average V{sub 100%} for the clinical target volume was reduced from the original 95.1% to 92.1{+-} 3.7% for prolonged treatment, and to 91.3{+-}5.4% when the treatment time was shortened by 50%. Due to the observed large sporadic prostate motions, we conclude that an on-line target motion monitoring and correction strategy is necessary to implement hypofractionated SBRT with intensity modulated beams for prostate cancer treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gradient changes in structural condition of the B2 phase of NiTi surface layers after electron-beam treatments

Structural conditions of the B2 phase of the Ti{sub 49.5}Ni{sub 50.5} alloy surface layers before and after electron-beam treatments (pulse duration τ = 150 μs, number of pulses n = 5, beam energy density E ≤ 20 J/cm{sup 2}) were studied by X-ray diffraction analysis. Analysis of the X-ray patterns demonstrates that surface layers modified by electron beam treatment contain phase with B2{sup surf} structure. It is revealed that the lattice parameter of the B2{sup surf} phase in the surface (modified) layer is also higher than the lattice parameter of the B2 phase in the underlying layer (a{sub B2} = 3.0159±0.0005). The values of lattice parameter of phase B2{sup surf} amounted a{sub B2}{sup surf} = 3.0316±0.0005 Å and a{sub B2}{sup surf} = 3.0252±0.0005 Å, for the specimens after electron-beam treatment at E{sub 1} = 15 J/cm{sup 2} and E{sub 2} = 20 J/cm{sup 2}, respectively. Inflated lattice parameters a{sub B2}{sup surf} are associated with changes in the chemical composition and the presence of residual stresses in the surface region of the samples after electron-beam treatments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of electron-beam lithography exposure current level on the transport characteristics of graphene field effect transistors

Many factors have been identified to influence the electrical transport characteristics of graphene field-effect transistors. In this report, we examine the influence of the exposure current level used during electron beam lithography (EBL) for active region patterning. In the presence of a self-assembled hydrophobic residual layer generated by oxygen plasma etching covering the top surface of the graphene channel, we show that the use of low EBL current level results in higher mobility, lower residual carrier density, and charge neutrality point closer to 0 V, with reduced device-to-device variations. We show that this correlation originates from the resist heating dependent release of radicals from the resist material, near its interface with graphene, and its subsequent trapping by the hydrophobic polymer layer. Using a general model for resist heating, we calculate the difference in resist heating for different EBL current levels. We further corroborate our argument through control experiments, where radicals are either intentionally added or removed by other processes. We also utilize this finding to obtain mobilities in excess of 18 000 cm{sup 2}/V s on silicon dioxide substrates. We believe these results are applicable to other 2D materials such as transition metal dichalcogenides and nanoscale devices in general.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-786: Utility of Gold Wires to Optimize Intensity Modulation Capacity of a Novel Directional Modulated Brachytherapy Tandem Applicator for Image Guided Cervical Cancer Brachytherapy

Purpose: To evaluate the impact of using gold wires to differentially fill various channels on plan quality compared with conventional T&R applicator, inside a novel directional modulated brachytherapy (DMBT) tandem applicator for cervical cancer brachytherapy. Materials and Methods: The novel DMBT tandem applicator has a 5.4-mm diameter MR-compatible tungsten alloy enclosed in a 0.3-mm thick plastic tubing that wraps around the tandem. To modulate the radiation intensity, 6 symmetric peripheral holes of 1.3-mm diameter are grooved along the tungsten alloy rod. These grooved holes are differentially filled with gold wires to generate various degrees of directional beams. For example, three different fill patterns of 1) all void, 2) all filled except the hole containing the 192-Ir source, and 3) two adjacent holes to the 192-Ir source filled were Monte Carlo simulated. The resulting 3D dose distributions were imported into an in-house-coded inverse optimization planning system to generate HDR brachytherapy clinical plans for 19 patient cases. All plans generated were normalized to the same D90 as the clinical plans and D2cc doses of OARs were evaluated. Prescription ranged between 15 and 17.5Gy. Results: In general, the plans in case 1) resulted in the highest D2cc doses for the OARs with 11.65±2.30Gy, 7.47±3.05Gy, and 9.84±2.48Gy for bladder, rectum, and sigmoid, respectively, although the differences were small. For the case 2), D2cc doses were 11.61±2.29Gy, 7.41±3.07Gy, and 9.75±2.45Gy, respectively. And, for the case 3), D2cc doses were 11.60±2.28Gy, 7.41±3.05Gy, and 9.74±2.45Gy, respectively. Difference between 1) and 2) cases were small with the average D2cc difference of <0.64%. Difference between 1) and 3) cases were even smaller with the average D2cc difference of <0.1%. Conclusions: There is a minimal clinical benefit by differentially filling grooved holes in the novel DMBT tandem applicator for image guided cervical cancer brachytherapy.

60 APPLIED LIFE SCIENCES↗

Background optimization of powder electron diffraction for implementation of the e-PDF technique and study of the local structure of iron oxide nanocrystals

The local structural characterization of iron oxide nanoparticles is explored using a total scattering analysis method known as pair distribution function (PDF) (also known as reduced density function) analysis. The PDF profiles are derived from background-corrected powder electron diffraction patterns (the e-PDF technique). Due to the strong Coulombic interaction between the electron beam and the sample, electron diffraction generally leads to multiple scattering, causing redistribution of intensities towards higher scattering angles and an increased background in the diffraction profile. In addition to this, the electron–specimen interaction gives rise to an undesirable inelastic scattering signal that contributes primarily to the background. The present work demonstrates the efficacy of a pre-treatment of the underlying complex background function, which is a combination of both incoherent multiple and inelastic scatterings that cannot be identical for different electron beam energies. Therefore, two different background subtraction approaches are proposed for the electron diffraction patterns acquired at 80 kV and 300 kV beam energies. From the least-square refinement (small-box modelling), both approaches are found to be very promising, leading to a successful implementation of the e-PDF technique to study the local structure of the considered nanomaterial.

36 MATERIALS SCIENCE↗

Direct Wavelength-Selective Optical and Electron-Beam Lithography of Functional Inorganic Nanomaterials

Direct optical lithography of functional inorganic nanomaterials (DOLFIN) is a photoresist-free method for highresolution patterning of inorganic nanocrystals (NCs) that has been demonstrated using deep UV (DUV, 254 nm) photons.In this work, we expand the versatility of DOLFIN by designing a series of photochemically active NC surface ligands for direct patterning using various photon energies including DUV, near-UV (i-line, 365 nm), blue (h-line, 405 nm), and visible (450 nm) light. We show that the exposure dose for DOLFIN can be similar to 30 mJ/cm 2 , which is small compared to most commercial photopolymer resists. Patterned nanomaterials can serve as highly robust optical diffraction gratings. We also introduce a general approach for resist-free direct electron-beam lithography of functional inorganic nanomaterials (DELFIN) which enables all-inorganic NC patterns with feature size down to 30 mu, while preserving the optical and electronic properties of patterned NCs. The designed ligand chemistries and patterning techniques offer a versatile platform for nano- and micron-scale additive manufacturing, complementing the existing toolbox for device fabrication.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The corrosion pattern of reinforcement and its influence on serviceability of reinforced concrete members in chloride environment

This paper deals with two corroded reinforcement concrete beams, which have been stored under sustained load in a chloride environment for 14 and 23 years respectively. The evolution of corrosion pattern of reinforcement and its influence on serviceability are studied. In chloride-induced corrosion process, corrosion cracking affects significantly the corrosion pattern. During the corrosion cracking initiation period, only local pitting corrosion occurs. At early stage of cracking propagation, localized pitting corrosion is still predominant as cracks widths are very small and cracks are not interconnected, but a general corrosion slowly develops as the cracks widen. At late cracking stage, interconnected cracking with wide width develops along large parts of the beam leading to a general corrosion pattern. Macrocells and microcells concepts are used for the interpretation of the results. Mechanical experiments and corrosion simulation tests are performed to clarify the influence of this corrosion pattern evolution on the serviceability of the beams (deflection increase). Experimental results show that, when the corrosion is localized (early cracking stage), the steel-concrete bond loss is the main factor affecting the beams serviceability. The local cross-section loss resulting from pitting attack does not significantly influence the deflection of the beam. When corrosion is generalized (late cracking stage), as the steel-concrete bond is already lost, the generalized steel cross-section reduction becomes the main factor affecting the beams serviceability. But, at this stage, the deflection increase is slower due to the low general corrosion rate.

36 MATERIALS SCIENCE↗