Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Optical Transition Radiation System for ATF2

In this paper we present the first measurements performed during the fall 2010 and early 2011 runs. Software development, simulations and hardware improvements to the Multi-Optical Transition Radiation System installed in the beam diagnostic section of the Extraction line of ATF2 are described. 2D emittance measurements have been performed and the system is being routinely used for coupling correction. Realistic beam simulations have been made and compared with the measurements. A demagnifier lens system to improve the beam finding procedure has been designed and will be implemented in a future run. We also discuss further work planned for the subsequent run periods.

43 PARTICLE ACCELERATORS↗

Performance characteristics of the 12 GHz, 200 watt Transmitter Experiment Package for CTS

Measured performance characteristics from ground test of the Transmitter Experiment Package (TEP) for the Communications Technology Satellite are presented. The experiment package consists of a 200 W Output Stage Tube (OST) powered by a Power Processing System (PPS). Descriptions of both the PPS and OST are given. The PPS provides the necessary voltages with a measured dc/dc conversion efficiency of 89 per cent. The OST, a traveling wave tube with multiple collectors, has a saturated rf output power of 224 W and operates at an overall efficiency exceeding 40 per cent over an 85 MHz bandwidth at 12 GHz. OST performance given includes frequency response, saturation characteristics, group delay, AM to PM conversion, intermodulation distortion, and two channel gain suppression. Single and dual channel FM video performance is presented. It was determined that for 12 MHz peak to peak frequency deviation on each channel, dual channel FM television signals can be transmitted through the TEP at 60 W, each channel, with 40 MHz channel spacing (center to center).

Miller, E. F.↗

Image quality measures and their performance

A number of quality measures are evaluated for gray scale image compression. They are all bivariate exploiting the differences between corresponding pixels in the original and degraded images. It is shown that although some numerical measures correlate well with the observers' response for a given compression technique, they are not reliable for an evaluation across different techniques. The two graphical measures (histograms and Hosaka plots), however, can be used to appropriately specify not only the amount, but also the type of degradation in reconstructed images.

Eskicioglu, Ahmet M.↗

Testing of Liquid Metal Components for Nuclear Surface Power Systems

The capability to perform testing at both the module/component level and in near prototypic reactor configurations using a non-nuclear test methodology allowed for evaluation of two components critical to the development of a potential nuclear fission power system for the lunar surface. A pair of 1 kW Stirling power convertors, similar to the type that would be used in a reactor system to convert heat to electricity, were integrated into a reactor simulator system to determine their performance using pumped NaK as the hot side working fluid. The performance in the pumped-NaK system met or exceed the baseline performance measurements where the converters were electrically heated. At the maximum hot-side temperature of 550 C the maximum output power was 2375 watts. A specially-designed test apparatus was fabricated and used to quantify the performance of an annular linear induction pump that is similar to the type that could be used to circulate liquid metal through the core of a space reactor system. The errors on the measurements were generally much smaller than the magnitude of the measurements, permitting accurate performance evaluation over a wide range of operating conditions. The pump produced flow rates spanning roughly 0.16 to 5.7 l/s (2.5 to 90 GPM), and delta p levels from less than 1 kPa to 90 kPa (greater than 0.145 psi to roughly 13 psi). At the nominal FSP system operating temperature of 525 C the maximum efficiency was just over 4%.

Polzin, K. A.↗

The Atacama Cosmology Telescope: Mitigating the Impact of Extragalactic Foregrounds for the DR6 Cosmic Microwave Background Lensing Analysis

We investigate the impact and mitigation of extragalactic foregrounds for the cosmic microwave background (CMB) lensing power spectrum analysis of Atacama Cosmology Telescope (ACT) data release 6 (DR6) data. Two independent microwave sky simulations are used to test a range of mitigation strategies. We demonstrate that finding and then subtracting point sources, finding and then subtracting models of clusters, and using a profile bias-hardened lensing estimator together reduce the fractional biases to well below statistical uncertainties, with the inferred lensing amplitude, A lens , biased by less than 0.2σ. We also show that another method where a model for the cosmic infrared background (CIB) contribution is deprojected and high-frequency data from Planck is included has similar performance. Other frequency-cleaned options do not perform as well, either incurring a large noise cost or resulting in biased recovery of the lensing spectrum. In addition to these simulation-based tests, we also present null tests on the ACT DR6 data for sensitivity of our lensing spectrum estimation to differences in foreground levels between the two ACT frequencies used, while nulling the CMB lensing signal. These tests pass whether the nulling is performed at the map or bandpower level. The CIB-deprojected measurement performed on the DR6 data is consistent with our baseline measurement, implying that contamination from the CIB is unlikely to significantly bias the DR6 lensing spectrum. This collection of tests gives confidence that the ACT DR6 lensing measurements and cosmological constraints presented in companion papers to this work are robust to extragalactic foregrounds.

79 ASTRONOMY AND ASTROPHYSICS↗

Rotor Hover Performance and Flowfield Measurements with Untwisted and Highly-Twisted Blades

The flowfield and performance characteristics of highly-twisted blades were analyzed at various thrust conditions to improve the fundamental understanding relating the wake effects on rotor performance. Similar measurements made using untwisted blades served as the baseline case. Twisted blades are known to give better hover performance than untwisted blades at high thrust coefficients typical of those found in full-scale rotors. However, the present experiments were conducted at sufficiently low thrust (beginning from zero thrust), where the untwisted blades showed identical, if not better, performance when compared with the highly-twisted blades. The flowfield measurements showed some key wake differences between the two rotors, as well. These observations when combined with simple blade element momentum theory (also called annular disk momentum theory) helped further the understanding of rotor performance characteristics.

Ramasamy, Manikandan↗

Application and evaluation of a pattern-based building energy model calibration method using public building datasets

Building performance simulation has been adopted to support decision making in the building life cycle. An essential issue is to ensure a building energy simulation model can capture the reality and complexity of buildings and their systems in both the static characteristics and dynamic operations. Building energy model calibration is a technique that takes various types of measured performance data (e.g., energy use) and tunes key model parameters to match the simulated results with the actual measurements. This study performed an application and evaluation of an automated pattern-based calibration method on commercial building models that were generated based on characteristics of real buildings. A public building dataset that includes high-level building attributes (e.g., building type, vintage, total floor area, number of stories, zip code) of 111 buildings in San Francisco, California, USA, was used to generate building models in EnergyPlus. Monthly level energy use calibrations were then conducted by comparing building model results against the actual buildings' monthly electricity and natural gas consumption. The results showed 57 out of 111 buildings were successfully calibrated against actual buildings, while the remaining buildings showed opportunities for future calibration improvements. Enhancements to the pattern-based model calibration method are identified to expand its use for: (1) central heating, ventilation and air conditioning (HVAC) systems with chillers, (2) space heating and hot water heating with electricity sources, (3) mixed-use building types, and (4) partially occupied buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-thrust and low-power operation of a 30-cm-diameter mercury ion thruster

An investigation of a 30-cm-diameter mercury ion thruster designed for high-thrust and low-power operation is described. Experimental results are presented which indicate that good performance and long lifetime are achieved by using a boundary magnetic field arrangement to confine the ionizing electrons. Details of advanced ion-optics designs are discussed, and performance measurements obtained with an advanced two-grid ion-optics assembly are presented. Scaling of the state-of-the-art hollow cathode for higher emission-current capability is described, and performance and lifetime measurements are presented for the scaled cathode.

Beattie, J. R.↗

Vibrational Studies of Saccharide-Induced Lipid Film Reorganization at Aqueous/Air Interfaces

Vibrational sum frequency generation (VSFG) and surface tension experiments were used to examine the effects of aqueous phase soluble saccharides on the structure and organization of insoluble lipid monolayers adsorbed to aqueous-air interfaces. Changes in dipalmitoylphosphocholine (DPPC) chain structure as a function of aqueous phase saccharide concentration and pH are reported. Complementary differential scanning calorimetry (DSC) measurements performed on solutions containing soluble saccharides and DPPC vesicles measured the effects of the saccharides on the lipid membrane phase behavior. Here, data show that the saccharides glucosamine and glucuronic acid induce a higher degree of organization in compressed DPPC monolayers regardless of the saccharide’s charge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Corrections for the geometric distortion of the tube detectors on SANS instruments at ORNL

Small-angle neutron scattering instruments at the Oak Ridge National Laboratory's High Flux Isotope Reactor were upgraded in area detectors from the large, single volume crossed-wire detectors originally installed to staggered arrays of linear position-sensitive detectors (LPSDs). The specific geometry of the LPSD array requires that approaches to data reduction traditionally employed be modified. Here, two methods for correcting the geometric distortion produced by the LPSD array are presented and compared. The first method applies a correction derived from a detector sensitivity measurement performed using the same configuration as the samples are measured. In the second method, a solid angle correction is derived that can be applied to data collected in any instrument configuration during the data reduction process in conjunction with a detector sensitivity measurement collected at a sufficiently long camera length where the geometric distortions are negligible. Furthermore, both methods produce consistent results and yield a maximum deviation of corrected data from isotropic scattering samples of less than 5% for scattering angles up to a maximum of 35°. The results are broadly applicable to any SANS instrument employing LPSD array detectors, which will be increasingly common as instruments having higher incident flux are constructed at various neutron scattering facilities around the world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel approach to Hugoniot measurements utilizing transparent crystals

A new absolute equation of state measurement technique is described and demonstrated measuring the shock state and the refractive index of MgO up to 226GPa. This technique utilizes steady shock waves and the high-pressure transparency of MgO under dynamic shock compression and release. Hugoniot measurements performed using this technique are consistent with the previous measurements. A linear dependence of the shocked refractive index and density is observed up to 226GPa, over a magnitude greater in pressure that previous studies. The transparency of MgO along the principal Hugoniot is higher than any other material reported to date. We observe a significant change in the refractive index of MgO as the Hugoniot elastic limit is exceeded due to the transition from uniaxial to hydrostatic strain. Measurements of the elastic-plastic two-wave structure in MgO indicate a nucleation time for plastic deformation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Light-assisted recharging of graphene quantum dots in fluorographene matrix

In the present study, the charge transient spectroscopy was used to analyze the transient relaxation of charges in graphene and bilayer-graphene quantum dot (QD) systems formed by chemical functionalization of graphene and few-layer graphene layers. A set of activation energies (one to three different values) for the emission of charges from QDs sized 50 to 70 nm, most likely proceeding via the thermal activation of charge carriers from QD quantum confinement levels, were deduced from measurements performed in the dark. Daylight illumination of samples during measurements was found to result in a strong decrease of the activation energies and in an involvement of an athermal process in the charge relaxation phenomenon. The time of the light-assisted emission of charge carriers from QDs proved to be two to four orders of magnitude shorter than the time of their emission from QDs under no-illumination conditions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Testing electron boost invariance with 2S-1S hydrogen spectroscopy

There are few good direct laboratory tests of boost invariance for electrons, because the experiments required often involve repeated precision measurements performed at different times of the year. However, existing measurements and remeasurements of the 2S-1S two-photon transition frequency in {sup 1}H--which were done to search for a time variation in the fine structure constant--also constitute a measurement of the boost symmetry violation parameter 0.83c{sub (TX)}+0.51c{sub (TY)}+0.22c{sub (TZ)}=(4{+-}8)x10{sup -11}. This is an 8 order of magnitude improvement over preexisting laboratory bounds, and with only one additional measurement, this system could yield a second comparable constraint.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A nonproprietary, nonsecret program for calculating Stirling cryocoolers

A design program for an integrated Stirling cycle cryocooler was written on an IBM-PC computer. The program is easy to use and shows the trends and itemizes the losses. The calculated results were compared with some measured performance values. The program predicts somewhat optimistic performance and needs to be calibrated more with experimental measurements. Adding a multiplier to the friction factor can bring the calculated rsults in line with the limited test results so far available. The program is offered as a good framework on which to build a truly useful design program for all types of cryocoolers.

Martini, W. R.↗

Validation of realistic Monte Carlo plasma gamma-ray source on JET discharges

A novel modelling methodology has been developed for the creation of a realistic plasma gamma-ray source for Monte Carlo transport simulations in the tokamak JET. The methodology couples the TRANSP code for plasma transport calculations with the MCNP Monte Carlo particle transport code, thus connecting plasma physics with gamma-ray transport. Here, we present the validation of the developed source methodology by comparing calculated gamma-ray spectra with measurements performed at JET. The validation focuses on gamma-ray spectra measured by the tangential gamma-ray spectrometer during two JET three ion RF scenario discharges, performed in the JET 2019 deuterium experimental campaign. For validation the calculated plasma gamma-ray spectrum was combined with the neutron induced prompt gamma-ray background, originating in the vacuum vessel, and scaled to absolute values calculating the total number of plasma gamma-ray and neutron emitting reactions. The comparison between calculated and measured gamma-ray spectra shows good agreement with the shape of the calculated gamma-ray spectra matching that of measurements for both studied discharges. Moreover, the calculated absolute values of the gamma-ray spectra were of the same order of magnitude at the position of the gamma-ray detector located at the end of a long line-of-sight in a biological shield. Finally, the comparison has validated the developed plasma gamma-ray source methodology for MCNP photon transport calculations at JET. The validation provides a basis for the developed plasma gamma-ray source to be used as a support for the development of future tokamaks such as DEMO.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of adding roughness and thickness to a transonic axial compressor rotor

The performance deterioration of a high speed axial compressor rotor due to surface roughness and airfoil thickness variations is reported. A 0.025 mm (0.001 in.) thick rough coating with a surface finish of 2.54-3.18 RMS microns (100-125 RMS microinches) is applied to the pressure and suction surface of the rotor blades. Coating both surfaces increases the leading edge thickness by 10% at the hub and 20% at the tip. Application of this coating results in a loss in efficiency of 6 points and a 9% reduction in the pressure ratio across the rotor at an operating condition near the design point. To separate the effect of thickness and roughness, a smooth coating of equal thickness is also applied to the blade. The smooth coating surface finish is 0.254-0.508 RMS microns (10-20 RMS microinches), compared to the bare metal blade surface finish of 0.508 RMS microns (20 RMS microinches). The smooth coating results in approximately half of the performance deterioration found from the rough coating. Both coatings are then applied to different portions of the blade surface to determine which portions of the airfoil are most sensitive to thickness/roughness variations. Aerodynamic performance measurements are presented for a number of coating configurations at 60%, 80%, and 100% of design speed. The results indicate that thickness/roughness over the first 10% of blade chord accounts for virtually all of the observed performance degradation for the smooth coating, compared to about 70% of the observed performance degradation for the rough coating. The performance deterioration is investigated in more detail at design speed using laser anemometer measurements as well as predictions generated by a quasi-3D Navier-Stokes flow solver which includes a surface roughness model. Measurements and analysis are performed on the baseline blade and the full-coverage smooth and rough coatings. The results indicate that coating the blade causes a thickening of the blade boundary layers. The interaction between the rotor passage shock and the thickened suction surface boundary layer then results in an increase in blockage which reduces the diffusion level in the rear half of the blade passage, thus reducing the aerodynamic performance of the rotor.

Suder, Kenneth L.↗

Phase space density as a measure of cooling performance for the international muon ionization cooling experiment

The International Muon Ionization Cooling Experiment (MICE) is an experiment to demonstrate ionization cooling of a muon beam in a beamline that shares characteristics with one that might be used for a muon collider or neutrino factory. I describe a way to quantify cooling performance by examining the phase space density of muons, and determining how much that density increases. This contrasts with the more common methods that rely on the covariance matrix and compute emittances from that. I discuss why a direct measure of phase space density might be preferable to a covariance matrix method. I apply this technique to an early proposal for the MICE final step beamline. I discuss how matching impacts the measured performance.

43 PARTICLE ACCELERATORS↗

Measures of illuminant-induced metameric mismatch: theory, comparative analysis, and implications for application

Illuminant-induced metameric mismatch is an important consideration in the specification of light sources for some architectural environments, yet there is currently no standardized performance measure. The goal of this work was to evaluate two recent research proposals: the metameric uncertainty index ( R t ) and the metamer mismatching color rendering index (MMCRI). To compare the relative performance of these two measures, 100,000 spectral power distributions were generated with 3, 4, 5, 6, and 7 Gaussian spectral components and spectral widths varying from 1 nm (monochromatic) to 100 nm. Both measures generally agree with the theory that broadband radiation should cause less metameric mismatch than narrowband radiation. The two measures have relatively better agreement for broadband SPDs and relatively worse agreement for narrower spectra. Despite some similarities, non-parametric statistical tests suggest that R t and MMCRI are significantly different quantifications of illuminant-induced metameric mismatch ( p < 0.0001 for all comparisons). Characteristics of the MMCRI computation that are potentially problematic for applied lighting were observed.

42 ENGINEERING↗