Search NASA⌕ Search

SEARCH · Search NASA

Results for “procurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Light Water Reactor Sustainability Program: Report on the Completion of the Machining of Zion Unit 1 Reactor Pressure Vessel Blocks into Mechanical and Microstructural Test Specimens and Chemical Analysis Coupons

The decommissioning of the Zion Units 1 and 2 Nuclear Generating Station in Zion, Illinois, presented a unique opportunity for developing a better understanding of materials degradation and other issues associated with extending the lifetime of existing nuclear power plants (NPPs) beyond 60 years of service. In support of extended service and current operations of the US nuclear reactor fleet, the Oak Ridge National Laboratory (ORNL), through the Department of Energy (DOE), Light Water Reactor Sustainability (LWRS) Program, coordinated with Zion Solutions, LLC, a subsidiary of Energy Solutions (ES), the selective procurement of materials, structures, and components, from the decommissioned reactors including multiple segments of the Zion Unit 1 Reactor Pressure Vessel (RPV).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Comparison of Cargo X-Ray Attenuation as Measured by Top-Down versus Side-View Imaging Systems

Because millions of cargo containers enter the United States each year, there are millions of opportunities for terrorists to smuggle in dangerous radiological or special nuclear materials. The Department of Homeland Security (DHS) has been tasked to ensure that the United States remains safe from the illicit transportation, development, or procurement of a radiological/ nuclear (R/N) device or materials. The Nuclear and Radiological Imaging Platform (NRIP) program within DHS/CWMD aims to develop and characterize the performance of an integrated R/N detection platform and to determine if it performs better than previous screening systems. The cargo scanner developed by Passport features several technologies that have never been fielded, including the subsystem that my project involved. I concentrated on the high-energy Xray transmission imaging subsystem for producing 2D (top-down view) attenuation images. This subsystem was created to help identify highly-attenuating potential threats, but I focused on a smaller, more specific topic for my project. I worked on converting attenuations in the top-down X-ray transmission images into equivalent steel thickness. For example, a slab of material with a given attenuation would be converted into an equivalent thickness of steel that would have the same attenuation. Equivalent steel thickness provides a consistent way to compare data acquired by different inspection systems.

47 OTHER INSTRUMENTATION↗

A Modular and Flexible High-Frequency-Link Transformer with a Reduced Device Count and Zero High-Side Devices

In general, large power transformers (LPTs) are not interchangeable with each other and their high costs prohibit extensive spare inventories more so considering that on an average only 1.3 LPTs are manufactured for individual design. The latter pose a further challenge since given that the several existing LPTs are reaching their end of service lives, loss of plurality of such LPTs, that form the backbone of U.S. power grid, will clearly run into the problem of energy security related to the non-availability of sufficient spares (and extended lead time) exacerbated further by the fact that these spares are not interchangeable for installations at different locations. Conventional LPT cost millions of dollars and weighs significantly between approximately 100 and 400 tons. Two raw materials—copper and electrical steel—account for over 50 percent of the total cost of an LPT. In recent years, the price volatility of these two commodities in the global market has affected the manufacturing conditions and procurement strategy for LPTs. Transportation is also an important element of the total LPT cost, because an LPT can weigh significantly and often requires long-distance transport. Transporting an LPT is challenging—its large dimensions and heavy weight pose unique requirements to ensure safe and efficient transportation. Current road, rail, and port conditions are such that transportation is taking more time and becoming more expensive. Conventional low-frequency LPTs typically follow a monolithic approach to design due to historical reasons that need to transition to more modular and flexible (e.g., in voltage, impedance, and power flow) designs with ability to seamlessly/near-seamlessly scale. They should also have the ability to incorporate new technologies without in all cases redoing a LPT design from scratch. Given that the cost of raw materials has continued to increase, next-generation LPTs need to pursue avenues for reducing these costs. An added necessity is to reduce the transportability cost, which is significant in conventional LPTs. Further, given that LPTs are for the long term, they need to be durable, efficient, and fault tolerant with overloading capability. Given this backdrop, the objective and accomplishment of this one-year DOE (SPONSOR) R&D project, led by small business NextWatt LLC (PRIME, Lead PI: Dr. Sudip K. Mazumder) and University of Arkansas at Fayetteville (SUBAWARDEE, PI: Dr. Juan Balda) were to explore the design of a (8 – 20 kHz) high-frequency-link (HFL) based 100-MVA LPT with nominal voltage of 115/69 kV, with $15 - $22 dollars US per kVA when manufactured in “moderate” volume, with 99% energy-conversion efficiency, with 300% reduction in both volume and weight compared to a conventional LPT with the same electrical ratings, with impedance variation greater than 5%, with direct AC/AC power conversion capability, with very-high energy-conversion efficiency (using wide-bandgap SiC based field effect MOSFET devices) over a wide operating temperature, with reduction in both volume and weight with regard to conventional low frequency LPT, and with significant reduction in number of devices compared to state of the art solid state transformer topology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lidar Buoy Data Analysis: Basic Assessment of Observed Conditions and Instrument Performance Off Virginia and New Jersey

One of the challenges for developing offshore wind energy in the United States has been a lack of long-term observations to characterize the wind resource and design load conditions and to provide validation for the numerical weather prediction models. To address this challenge, the U.S. Department of Energy supported the procurement in 2014 and subsequent deployment of two buoys equipped with motion-compensated lidars and a comprehensive set of supporting meteorological and oceanographic (“metocean”) measurement systems. Each of the systems was deployed off the U.S. East Coast in excess of one year—one each near the coasts of Virginia and New Jersey. One notable observation from both buoys is the dramatic dependence of the wind shear on atmospheric stability as indicated by the air-sea temperature difference. This observation suggests that the commonly used neutral log law will not be a fully suitable representation of wind shear off the U.S. East Coast. This report provides a basic summary of observations at each location from key systems on each of the buoys as well as an assessment of instrument performance. These data are beginning to fill a long-standing observational gap for the wind energy community in the United States.

17 WIND ENERGY↗

Dual-Purpose Canister Filling Demonstration Project Progress Report, Rev. 1

This report discusses the initial progress made at the Oak Ridge National Laboratory to support direct disposal of dual-purpose canisters (DPCs)using filler materials to demonstrate that the probability of criticality in DPCs during disposal to be below the probability for inclusion in a repository performance assessment. In the initial phase of a multi-phase effort that will result in a full-scale demonstration, a computational fluid dynamics (CFD) model was developed to gauge the filling process and to uncover any unforeseen issues. The initial filling simulations of the lower region (mouse holes) of a prototypic DPC show successful removal of the inner space voids and smooth,even progression of the liquid level. In the initial phase, flow through a pipe that is similar to the drain pipe in a DPC will be investigated separately to gain valuable insight of flow regime inside a pipe. The initial experimental setups for validating the computational filling model have been designed,and the various assembly parts are being procured. The experience gained from the initial experiments will be applied to the next steps toward a full-scale demonstration and to the validation of multiphysics filling simulation models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pilot Test of Novel Electrochemical Membrane System for Carbon Dioxide Capture and Power Generation (Final Report)

The goal of this U.S. Department of Energy (DOE) sponsored project under cooperative agreement DE-FE0026580 is to verify that Fuel Cell Energy’s (FCE) Electrochemical Membrane (ECM)-based Combined Electric Power and Carbon Separation (CEPACS) system can achieve at least 90% carbon dioxide (CO 2 ) capture rate from Pulverized Coal (PC) power plant flue gas with 95% CO2 purity at a cost of electricity (COE) 30% less than baseline CO 2 capture approaches. To progress towards the DOE’s ultimate carbon capture program goals, the specific objectives of Budget Period 1 (BP1) of the project are to perform a preliminary Techno-Economic Analysis (TEA) and Environmental, Health and Safety (EH&S) Risk Assessment study, as well as to complete the detailed design of a pilot-scale ECM-based CEPACS system. This final technical report summarizes the results of the preliminary TEA and EH&S assessment of an ECM-based CEPACS system designed to capture and compress >90% of CO 2 from the flue gas of a reference 550 MW (net AC) Pulverized Coal (PC) Supercritical Steam Cycle Plant. Also included in this report is a summary of the detailed design for a pilot 3 MWe (flue gas equivalent) ECM-based CEPACS system designed to capture ≥90% of CO 2 from a PC plant flue gas slipstream and produce high-purity (≥95%) CO 2 . The pilot system is designed to process a slipstream of flue gas from the Unit 5 coal-fired boiler at the James M. Barry Electric Generating Station (Plant Barry). Plant Barry is located in Bucks, Alabama and is owned and operated by Alabama Power Company, a subsidiary of Southern Company. The TEA shows that the ECM-based CO 2 capture technology has an economic advantage over the existing CO 2 capture technology and meets the DOE’s cost target and performance goals for post-combustion CO 2 capture. The EH&S study includes the identification and quantification of the emissions from the CEPACS system. Properties of the waste including reactivity, flammability, corrosivity and toxicological effects are discussed along with the methods for minimization/elimination where applicable. The study shows that no major EH&S issues are expected to hinder commercialization of the ECM technology for large scale carbon capture applications. The detailed Front End Engineering Design (FEED) package for FCE’s MW-class ECM-based CO 2 capture pilot system is complete. It is designed in accordance with the project objectives and is now at a point where equipment/component procurement, skid final design and fabrication, and site preparation activities can begin in a follow-on project phase.

20 FOSSIL-FUELED POWER PLANTS↗

Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applying the Transactive Systems Business Value Model to IRP

As part of the Transactive Systems Program at Pacific Northwest National Laboratory, a value modeling system was developed to support the evaluation of transactive systems. The technique is general enough to be applied outside transactive systems and to demonstrate this capability, a project was undertaken to use this value modeling technique as a means for modeling the valuation process undertaken by vertically integrated utilities when undergoing integrated resource planning (IRP). IRP is the process by which vertically integrated utilities (those that both serve customers directly as well as manage and run generation assets to do so) regularly go through to demonstrate to their regulators that they have a plan to meet the expected future load of their customers in a least cost and compliant manner. Traditionally this has been primarily an issue of how many and of which types of power plants to build but increasingly has included alternative measures such as demand response programs. Increasingly, environmental regulations play a significant role in both determine what types of power plants can be built under current regulations as well as what retrofits or upgrades need to be made to existing plants to allow them to continue to operate. Two use-case diagrams were constructed, one showing the showing the process by which IRP is carried out and another showing how a vertically integrated utility procures the resources it requires to meet load now and in the future. These diagrams help clarify the difference and provide a high-level outline of the two processes. A class diagram was constructed to clearly define the types of actors that would be considered in this model and the relationships between them. This diagram tacitly indicates which types of actors are and are not included in the model which provides significant guidance in defining the scope of the model. The relationship between the classes/actors provides further indication of what areas of the model have higher levels of detail and by implication bear more significance in modeling the system. Using the classes/actors defined in the class diagram, a business value diagram was constructed that defines the key value streams exchanged between the actors. This diagram provides a clear expression of the business case of the vertically integrated utility and who its counterparties are during the process of meeting load. These value streams have not only to do with meeting the load but doing so in a manner that meets environmental regulations. Increasingly, IRPs have three key metrics to evaluate a given plant to meet load: net present value of revenue required, emissions, and renewable energy credits. From this business value diagram, more detailed activity diagrams were formed that focus on a few of the key value stream exchanges, showing the process by which each party accrues value. These diagrams provide insight into the timing and sequence of the interactions in a way that the business value diagrams did not. The transactive value model was found to be highly compatible with IRP and provided a clear, simple model of the analysis done during IRP and key metrics driving IRP decisions. In particular it highlighted a few key items that may or may not have been as clear prior to the development of the model. Specifically, the role of the environmental regulations has become increasingly important and two of the three key metrics by which IRPs are typically evaluated are environmentally focused. Additionally, though generally not acknowledged, the role of the investor was included in this model as they are an essential source of capital in building new power plants and cannot be ignored when defining the business case of the vertically integrated utility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Introduction to Grid Services: Concepts, Technical Requirements, and Provision from Wind

As the role of wind energy grows in the U.S. power grid, there is increased interest and requirements for it to provide 'essential reliability' services (historically often referred to as 'ancillary' services). These services are critical to maintaining the reliability and stability of the grid, and historically were provided by large 'synchronous' generators, mainly fossil-fueled and hydroelectric generators. To help evaluate the potential role of wind in providing these services, this report provides an overview of services provided to the grid, including their technical requirements, quantities currently procured, and some estimates of costs. The report also summarizes the technical and regulatory issues around wind providing these services.

17 WIND ENERGY↗

FY18 L2 Milestone #6360 Report: Initial Capability of an Arm-based Advanced Architecture Prototype System and Software Environment

The Vanguard program informally began in January 2017 with the submission of a white paper entitled "Sandia's Vision for a 2019 Arm Testbed" to NNSA headquarters. The program proceeded in earnest in May 2017 with an announcement by Doug Wade (Director, Office of Advanced Simulation and Computing and Institutional R&D at NNSA) that Sandia National Laboratories (Sandia) would host the first Advanced Architecture Prototype platform based on the Arm architecture. In August 2017, Sandia formed a Tri-lab team chartered to develop a robust HPC software stack for Astra to support the Vanguard program goal of demonstrating the viability of Arm in supporting ASC production computing workloads. This document describes the high-level Vanguard program goals, the Vanguard-Astra project acquisition plan and procurement up to contract placement, the initial software stack environment planned for the Vanguard-Astra platform (Astra), a description of how the communities of users will utilize the platform during the transition from the open network to the classified network, and initial performance results.

97 MATHEMATICS AND COMPUTING↗

Case Study: Nuclear-Renewable-Water Integration in Arizona

This document reports the application of the N-R HES software framework to a case study for Arizona Public Service (APS); the manager and part owner of the Palo Verde (PV) nuclear power plant. The case study is a work in progress of which this report presents a detailed description of the current model input data, assumptions and the corresponding results produced by the developed software framework. The goal of the report is, that with this information APS (together with INL) should be able to identify where more detailed data and more accurate model assumptions are necessary to reproduce all driving physical and economic phenomena in order to capture enough complexity of the reality to allow APS to use the results for their strategic decisions. The N-R HES software framework started being developed at INL two years ago [ref]. The framework has reached some level of maturity so that it can be applied to more than simple demonstration cases, e.g. real industry problems. Nevertheless, more capabilities are constantly added to accommodate the special needs of these challenging real life problems. The N-R HES framework is built on top of the RAVEN code [ref] and uses it as driver and workflow manager for all calculations. The framework has specifically been developed for the economic assessment of N-R HES systems. There are four main cornerstones of the N-R HES simulation framework: 1) generation of stochastic time series, 2) a probabilistic analysis and optimization set of algorithms available in RAVEN, 3) a set of models for representation of the physical behavior of N-R HES, and 4) a RAVEN plug-in that maps physical performance into economic performance called CashFlow. Within this framework, a broad spectrum of questions related to N-R HES can be addressed. One of the challenges currently of high interest is that the increasing penetration of variable renewables is altering the profile of the net demand (demand after removing all non curtailable renewable energy sources), with which the other generators on the grid have to cope. The N-R HES software framework is capable to analyze the potential feasibility of mitigating the resultant volatility in the net electricity demand. One possible solution to that problem currently intensively studied by the energy industry is adding stabilizing loads to the grid. These loads can be external industrial processes that are able to ramp production up and down quickly or adding variable internal loads that will lift the base load of the power plant. The latter is a possible solution currently studied by APS. APS if currently anticipating several challenges that will likely arise in the near future. One of them is, as mentioned, coping with the rapid growth of variable renewable energy (VRE) sources put on the grid. Although APS can sell its electricity for a fixed retail price to cover the local demand first, it also sells electricity in excess of the local demand at the Palo Verde energy hub. Due to the growing VRE penetration, the Palo Verde hub electricity spot price is negative more and more frequently. To mitigate this price volatility, APS is seeking to add more base load, so that the quantity of excess energy to be sold for prices potentially less than the internal retail price or even negative prices at the hub is reduced. A second challenge APS is facing is that their cooling water acquisition contract with the Sub Regional Operating Group (SROG) will expire soon and a renewal can only be done for a significantly higher price of the water. Therefore, APS is also seeking for alternative sources for their cooling water. An opportunity currently under investigation is to pump a limited quantity of brackish water from the regional ground water. Although much cheaper than the water from the new SROG contract, the salinity of the brackish water is so high that a blend of brackish and SROG water would need additional treatment to improve its quality for use in the cooling towers. An on-site reverse osmosis (RO) desalination plant is envisaged to reduce the salinity to an acceptable level. This report investigates the economic impact of such an RO plant. As one can see, the RO plant would help with both problems APS is facing: First, it would rise the APS base load helping to mitigate VRE induced hub price volatility. From this perspective, the RO plant can be seen as a stabilizing load on the grid as would be any other industrial process. Second, the RO’s goods, e.g. the clean water produced can be used by APS itself for a (hopefully) lower cost than 100% SROG water would be. The report will first describe the APS water procurement strategy in detail and lay out the possible alternative scenarios studied in this document. This is covered in Chapter 2. Next, in Chapter 3, the APS case model developed within the N-R HES software framework is described. This chapter includes also a description of the needed framework developments to accommodate the APS study.

97 MATHEMATICS AND COMPUTING↗

Trinity Benchmarks on the Intel Xeon Phi (Knights Corner)

This report documents the early experiences with porting and performance analysis of the Tri-Lab Trinity benchmark applications on Intel Xeon Phi (Knights Corner) (KNC) processor. KNC, the second generation of the Intel Many Integrated Core (MIC) architectures, uses a large number of small P54C-x86 cores with wide vector units and is deployed as PCI bus attached process accelerators. Sandia has experimental test beds of small InifiniBand clusters and workstations to investigate the performance of the MIC architecture. On these experimental test beds the programming models that may be investigated are "offload", "symmetric" and "native". Among these program usage models our primary interest is in the so called "native" mode, because the planned Trinity system to be deployed in 2016 using the next generation MIC processor architecture called Knights Landing would be self-hosted. Trinity / NERSC-8 benchmark programs cover a variety of scientific disciplines and they were used to guide the procurement of these systems. Architectures such as the Intel MIC are well suited to study evolving processor architectures and a usage model commonly referred to as MPI + X that facilitates migration of our applications to use both coarse grain and fine grain parallelism. Our focus with the applications selected is on the efficacy of algorithms in these applications to take advantage of features like: large number of cores, wide vector units, higher-bandwidth and deeper memory sub-system. This is a first step towards understanding applications, algorithms and programming environments for Trinity and future exascale computing systems.

97 MATHEMATICS AND COMPUTING↗

Challenges and Recommended Policies for Simultaneous Global Implementation of Low-GWP Refrigerants and High Efficiency in Room Air Conditioners

Increasing incomes, electrification, and urbanization—as well as a warming world—are driving up the global stock of air conditioners (ACs), particularly in emerging economies with hot climates. AC energy consumption is expected to increase substantially as the global stock of room ACs rises to 1.5 billion in 2030 and 2.5 billion in 2050. Hence, improving AC energy efficiency will be critical to reducing AC energy, cost (consumer lifecycle cost, electricity generation cost, etc.), peak load, and emissions impacts. The 2016 Kigali Amendment to the Montreal Protocol offers an opportunity to improve AC energy efficiency in tandem with the phasedown of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants. Based on the most recent information, a literature review, and interviews with manufacturers and industry experts, we find the main barriers to deploying high-efficiency ACs include concerns about market demand and cost, which could be mitigated by appropriately improved design of market-transformation programs such as standards and labeling, incentive, and procurement programs. The main barriers to the low-GWP refrigerant transition include the need for timely revision of safety standards and associated costs for capacity-building activities allowing safe use of low-GWP refrigerants in ACs. Policy action and the market transformation can be accelerated by advancing the refrigerant transition and efficiency improvements in parallel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ensuring Reliable Natural Gas-Fired Power Generation with Fuel Contracts and Storage

This report finds that natural gas-fired power plants purchase fuel both on the spot market and through firm supply contracts; there do not appear to be clear drivers propelling power plants toward one or the other type. Most natural gas-fired power generators are located near major natural gas transmission pipelines, and most natural gas contracts are currently procured on the spot market. Although there is some regional variation in the type of contract used, a strong regional pattern does not emerge. Whether gas prices are higher with spot or firm contracts varies by both region and year.

20 FOSSIL-FUELED POWER PLANTS↗

An Introduction to Grid Services: Concepts, Technical Requirements, and Provision from Wind

As the role of wind energy grows in the U.S. power grid, there is increased interest and requirements for it to provide 'essential reliability' services (historically often referred to as 'ancillary' services). These services are critical to maintaining the reliability and stability of the grid, and historically were provided by large 'synchronous' generators, mainly fossil-fueled and hydroelectric generators. To help evaluate the potential role of wind in providing these services, this report provides an overview of services provided to the grid, including their technical requirements, quantities currently procured, and some estimates of costs. The report also summarizes the technical and regulatory issues around wind providing these services.

17 WIND ENERGY↗

Dual-Purpose Canister Filling Demonstration Project Progress Report

This report discusses the initial progress made at the Oak Ridge National Laboratory to support direct disposal of dual-purpose canisters (DPCs) using filler materials to demonstrate that the probability of criticality in DPCs during disposal to be below the probability for inclusion in a repository performance assessment. In the initial phase of a multi-phase effort that will result in a full-scale demonstration, a computational fluid dynamics (CFD) model was developed to gauge the filling process and to uncover any unforeseen issues. The initial filling simulations of the lower region (mouse holes) of a prototypic DPC show successful removal of the inner space voids and smooth, even progression of the liquid level. In the initial phase, flow through a pipe that is similar to the drain pipe in a DPC will be investigated separately to gain valuable insight of flow regime inside a pipe. The initial experimental setups for validating the computational filling model have been designed, and the various assembly parts are being procured. The experience gained from the initial experiments will be applied to the next steps toward a full-scale demonstration and to the validation of multiphysics filling simulation models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving prediction of radioactive gas seepage for nuclear testing treaty verification

The length of time it takes for radioactive gases to seep from an underground nuclear test to the ground surface is crucial for verification of nuclear testing treaties, such as the Comprehensive Nuclear Test Ban Treaty (CTBT). The identification of short-lived radioactive gases emanating from the ground surface at a suspected nuclear test location could provide “smoking gun” type evidence of a nuclear test. Accurate predictions of radioactive gas arrival time and detection window (duration of time gas concentration is above its detection threshold) are critical for procuring this type of evidence. LANL researchers are working toward improving such predictions in support of the Global Security mission and Information Science & Technology science pillar.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Snohomish Public Utility District MESA 2: An Assessment of Flow Battery Energy Storage System Technical Performance

This report investigates the technical performance of the 2.2 MW, 8 MWh MESA 2 advanced vanadium flow battery energy storage system (FBESS), consisting of four 0.55 MW, 2 MWh strings, based on a number of baseline and use case tests. The FBESS is located at the Everett, Washington substation and owned by SnoPUD. The FBESS was procured by SnoPUD with matching funds by the Washington Clean Energy. Baseline tests were intended to assess the general technical capability of the FBESS (e.g., stored energy capacity, ramp rate performance, ability to track varying charge/discharge commands, direct current (DC) battery internal resistance). Use case tests were used to examine the performance of the FBESS while engaged in specific grid services (e.g., arbitrage, power factor correction). The project measured and/or calculated parameters that are important for understanding FBESS performance when subjected to actual field operation for achieving economic benefits, e.g., round trip efficiency (RTE) with and without rest, with and without auxiliary loads, auxiliary power consumption, signal command tracking, temperature trends during operation, parasitic power loss unaccounted by auxiliary load during rest, and state of charge (SOC) excursions. These baseline and use case parameters were analyzed using recorded test results. In addition, the results and lessons presented herein are also beneficial for any task or effort that needs technical assessment on similar and different types of FBESS based on technical specifications and/or field deployment results, since the assessment methodology remains the same.

25 ENERGY STORAGE↗