Search NASA⌕ Search

SEARCH · Search NASA

Results for “program metrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Site Environmental Report for 2009, Volume I

Each year, the University of California (UC), as the managing and operating contractor of the Ernest Orlando Lawrence Berkeley National Laboratory, prepares an integrated report regarding its environmental programs to satisfy the requirements of United States Department of Energy (DOE) Order 231.1A, Environment, Safety, and Health Reporting.1 The Site Environmental Report for 2009 summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year (CY) 2009. Throughout this report, 'Berkeley Lab' or 'LBNL' refers both to (1) the multiprogram scientific facility the UC manages and operates on the 202-acre university-owned site located in the hills above the UC Berkeley campus, and the site itself, and (2) the UC as managing and operating contractor for Ernest Orlando Lawrence Berkeley National Laboratory. The report is separated into two volumes. Volume I is organized into an executive summary followed by six chapters that contain an overview of LBNL, a discussion of its environmental management system (EMS), the status of environmental programs, summarized results from surveillance and monitoring activities, and quality assurance (QA) measures. Volume II contains individual data results from surveillance and monitoring activities. The Site Environmental Report is distributed by releasing it on the World Wide Web (Web) from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. Links to documents available on the Web are given with the citations in the References section. CD and printed copies of this Site Environmental Report are available upon request. The report follows Berkeley Lab's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are also reported using the more conventional (non-SI) system of measurements, because the non-SI system is referenced by several current regulatory standards and is more familiar to some readers. Two tables are provided at the end of the Glossary to help readers: Table G-1 defines the prefixes used with SI units of measurement, and Table G-2 provides conversions to non-SI units. Years mentioned in this report refer to calendar years unless specified as fiscal year(s). Berkeley Lab's fiscal year (FY) is October 1 to September 30, and begins in the year previous to its name, i.e., FY 2009 was from October 1, 2008, to September 30, 2009. For ease of reference, a key to acronyms and abbreviations used in this report can be found directly after the text, at the end of Chapter 6. Following that is also a glossary for readers who may be unfamiliar with some of the terms used in this report. This report was prepared under the direction of Ron Pauer of ESG. Please address any questions regarding this report to him by telephone at 510-486-7614, or by e-mail at ropauer@lbl.gov. The primary contributors were David Baskin, Tim Bauters, Ned Borglin, Robert Fox, John Jelinski, Ginny Lackner, Patrick Thorson, Linnea Wahl, and Suying Xu (Volume II). Readers are encouraged to comment on this report by completing the survey form found at the ESG Web page where this report is available.

57↗

Solving the duck curve in a smart grid environment using a non-cooperative game theory and dynamic pricing profiles

With the intermittency that comes with electricity generation from renewables, utilizing dynamic pricing will encourage the demand-side to respond in a smart way that would minimize the electricity costs and flatten the net electricity demand curve. Determining the optimal dynamic pricing profile that would leverage distributed storage to flatten the curve is a novel idea that needs to be studied. Moreover, the economic feasibility of utilizing distributed electrical energy storage is still not given in the literature. Therefore, in this paper, a novel way of solving a citywide dynamic model using a bilevel programming algorithm is introduced. The problem is developed as a novel non-cooperative Stackelberg game that utilizes air-conditioning systems and electrical storage through the end-users to determine the optimal dynamic pricing profile. The results show that the combined effect of utilizing demand-side air-conditioning systems and distributed storage together can flatten the curve while employing the optimal dynamic pricing profile. An economic study is performed to determine the economic feasibility of 20 different cases with different battery designs and the level of solar penetration. Three metrics were used to evaluate the economic performance of each case: the levelized cost of storage, the levelized cost of energy, and the simple payback period. Most cases had levelized cost of storage values lower than 0.457 $/kWh, which is the lower bound available in the literature. Seven out of 16 cases have a simple payback period shorter than the lifetime of the system (25 years). The case with a 100 MW PV power plant and a battery storage of size 597 MWh, was found to be the most promising case with a simple payback period of 12.71 years for the photovoltaic plant and 19.86 years for the demand-side investments.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

On Deployment of Multiple Base Stations for Energy-Efficient Communication in Wireless Sensor Networks

Data transmission from sensor nodes to a base station or a sink node often incurs significant energy consumption, which critically affects network lifetime. We generalize and solve the problem of deploying multiple base stations to maximize network lifetime in terms of two different metrics under one-hop and multihop communication models. In the one-hop communication model, the sensors far away from base stations always deplete their energy much faster than others. We propose an optimal solution and a heuristic approach based on the minimal enclosing circle algorithm to deploy a base station at the geometric center of each cluster. In the multihop communication model, both base station location and data routing mechanism need to be considered in maximizing network lifetime. We propose an iterative algorithm based on rigorous mathematical derivations and use linear programming to compute the optimal routing paths for data transmission. Simulation results show the distinguished performance of the proposed deployment algorithms in maximizing network lifetime.

Lin, Yunyue↗

City of Phoenix - Energize Phoenix Program

Energize Phoenix (EPHX) was designed as an ambitious, large-scale, three-year pilot program to provide energy efficiency upgrades in buildings, along Phoenix’s new Light Rail Corridor – part of a federal effort to reduce energy consumption and stimulate job growth, while simultaneously reducing the country’s carbon footprint and promoting a shift towards a green economy. The program was created through a 2010 competitive grant awarded to the City of Phoenix who managed the program in partnership with Arizona State University (ASU), the state’s largest university, and Arizona Public Service (APS), the state’s largest electricity provider. The U.S. Department of Energy (DOE) Better Buildings Neighborhood Program (BBNP) and the American Recovery and Reinvestment Act (ARRA) of 2009 provided $25M in funding for the EPHX program. The Light Rail Corridor runs through the heart of downtown Phoenix, making most high-rise and smaller commercial buildings eligible to participate in the EPHX program, along with a diverse mix of single and multi-family residential buildings. To ensure maximum impact and deeper market penetration, Energize Phoenix was subdivided into three unique parts: i. commercial rebate program, ii. commercial financing program, and iii. residential program Each component was managed by the City of Phoenix in partnership with APS. Phoenix was fortunate to partner with APS, which already operated robust commercial and residential rebate programs within its service territory. Phoenix tapped into the existing utility contractor network, provided specific training to over 100 contracting firms, and leveraged the APS rebate program structure (energy efficiency funding) to launch the EPHX commercial and residential rebate programs. The commercial finance program was coordinated and managed through a contract with National Bank of Arizona, NBAZ, which also provided project capital leveraging EPHX finance funds. Working in unison, approved contractors jointly produced more than 161,000 labor hours in pursuit of EPHX goals over the life of the project. Labor hours were spread among electricians, heating, ventilating and air-conditioning (HVAC) technicians, marketing professionals, engineers, sales, and administrative support staff across the approved contractor workforce. Program participants received both the utility rebate along with the EPHX rebate, and depending on project size and utility rebate structure some projects resulted in low to no-cost upgrades for customers. Phoenix also partnered with ASU, a grant sub-recipient, to leverage the institution’s expertise in research and data analysis. In this partnership, ASU accepted marketing responsibilities for the grant and partnered with DRA Communications (DRA), a Phoenix-based marketing firm, to create and communicate the message out to the marketplace. The EPHX program has completed its energy upgrade activities. A review of the work completed by ASU revealed that the EPHX program substantially exceeded the program’s stated goals by retrofitting/upgrading over 33 million sq ft of commercial space (30 million sq ft goal exceeded by 11%) and 2,014 residential units (1,700 unit goal exceeded by 18%) along the Light Rail Corridor. The program helped stimulate economic growth by adding $31million to the local economy and enhanced an already robust energy efficiency contractor network. This contractor network will continue to promote utility energy incentives to sustain energy efficiency upgrade activities in the future. Finally, EPHX helped reduce participants annual energy consumption by 135 million kilowatt-hour (kWh) translating into over $12.5 million of annual energy cost avoidance for the community. This also resulted in projected payback period of 4.5 years for total investment by all parties and reduced greenhouse gas emissions by over 95,000 metric tons of carbon dioxide equivalent (CO2e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Yield, Economical and Environmentally Benign Production of Rare Earth Elements from Coal Ash [Abstract]

Fly ash stored in landfills and ponds across the United States is an attractive, abundant domestic resource for the cost-effective recovery of rare earth elements (REE) and other critical minerals (CM). Physical Sciences Inc. (PSI) and its team members, Winner Water Services (WWS) and University of Kentucky/Center for Applied Energy Research (UK/CAER) successfully executed a multiphase program that developed and demonstrated pilot plant operations for cost-effective and environmentally-friendly production of rare earth element oxide (REO) concentrates, and the critical minerals scandium and aluminum (in the forms of salts or oxide products). We constructed and operated a sub-scale (0.5 kg/day) micropilot facility to demonstrate the key physical and chemical processing operations, predict yields, and troubleshoot process bottlenecks. The project team then designed, constructed and operated two decoupled pilot plant operations: (1) an operational pilot plant for physical separation processes with a capacity of 0.4 metric tons per day (tpd) where we optimized processes to produce selected ash fractions as the feedstock for chemical processing as well as valuable byproducts such as cement substitute, cenospheres, magnetic ash and secondary fuel carbon, and (2) an operational pilot plant for chemical processing with a capacity of 0.5 tpd that developed optimized processes for the production of: (a) REO concentrates, (b) critical minerals recovery (Sc, Al), and (c) beneficiated ash as valuable byproduct suitable for cement applications.

01 COAL, LIGNITE, AND PEAT↗

FutureGen 2.0 Monitoring Systems Design Basis and Technology Selection: Geohydrologic, Geochemical and Geophysical Considerations

Advances in carbon capture and storage (CCS) technology show promise for addressing carbon dioxide (CO 2 ) emissions and global climate change concerns related to coal-fueled energy. The FutureGen 2.0 Project is intended to demonstrate 1) the technical feasibility of oxy-combustion technology as an approach for implementing carbon capture at new and existing coal-fueled energy facilities, and 2) utility-scale integration of transport and permanent storage of captured CO 2 in a deep geologic formation. Development of the FutureGen 2.0 CO 2 storage site is part of a larger project to design, build, and operate a commercial-scale CCS system capable of capturing, treating, and storing the CO 2 off-gas from a 168-MW(e) gross capacity oxy-combustion coal-fueled power plant located in Meredosia, Illinois—a first-of-its-kind, near-zero emissions coal-fueled power plant with CCS. In cooperation with the U.S. Department of Energy, the FutureGen 2.0 project partners will repower a previously retired oil-fired power plant with oxy-combustion technology to capture approximately 1.1 million metric tons of CO 2 each year—more than 90 percent of the plant’s carbon emissions. Emissions such as sulfur oxides, nitrogen oxides, and mercury will be reduced to near-zero levels. Safe and proven pipeline technology will be used to transport the CO 2 to the storage site and inject it deep into the subsurface through a network of deep-injection wells for long-term storage through geologic sequestration. An evaluation that considered pertinent hydrologic, geochemical, and geophysical processes was performed during development of the testing and monitoring program for the FutureGen 2.0 project. This evaluation informed the technology screening process and, in conjunction with project- and regulation-driven monitoring objectives, was the basis for monitoring technology selection. A summary of the overall monitoring approach adopted by the FutureGen 2.0 project, and a detailed description of the testing and monitoring activities that the FutureGen Industrial Alliance, Inc. will undertake at the FutureGen 2.0 storage site near Jacksonville, Illinois, are documented in a project-maintained testing and monitoring plan. All testing and monitoring activities will be performed in accordance with Title 40 of the Code of Federal Regulations (CFR) Sections 146.89, 146.90, and 146.91 (40 CFR §146.89, 146.90, and 146.91) to verify that the storage site is operating as permitted and is not endangering any underground sources of drinking water (USDWs).

54 ENVIRONMENTAL SCIENCES↗

Abstract for CRADA between NETL and Rivalia Chemical Co

The National Energy Technology Laboratory (NETL) will assist Rivalia Chemical Co (Participant) with system analyses to aid the Participant with setting priorities and securing funding. The Participant is an early-stage startup pioneering new chemical extraction technology to solve two important problems: critical mineral scarcity and coal ash waste management. The U.S. generates coal fly ash from coal combustion for power generation and has amassed over two billion metric tons of ash, which contains valuable rare earth elements. The ash is often stored in unlined ponds and frequently contaminates the local environment. The Participant’s patent-pending process harvests rare earths from ash, then transforms the residual ash for use in green concrete, providing an economic pathway for utilities to empty and remediate the ash ponds. Founder Laura Stoy created the company in July 2022 after developing the core intellectual property during her Ph.D. at the Georgia Institute of Technology. Stoy is currently participating in the Chain Reactions Innovations (CRI) program at the U.S. Department of Energy (DOE) Argonne National Laboratory (ANL) where she will be optimizing the core technology and scaling from bench scale to demonstration scale. The technology has been validated at bench scale (TRL3); the goal is to approach TRL5 by the conclusion of the CRI program and prepare to raise capital investment for a pilot facility. NETL and the Participant will develop an updated technoeconomic analysis (TEA) and identify key sustainability performance parameters to inform ’s research and development priorities and de-risk the technology. NETL will also provide the Participant with guidance to prepare a more detailed life cycle assessment (LCA), and a narrative on the Participant’s product markets. These tools will aid the Participant with the next steps of commercialization.

01 COAL, LIGNITE, AND PEAT↗

Life-cycle analysis of offshore macroalgae production systems in the United States

Offshore macroalgae production offers the potential to provide valuable biomass for food, energy, and higher value products without the use of land or freshwater while using excess nutrients and carbon dioxide. To realize this potential, the Macroalgae Research Inspiring Novel Energy Resources program of the Advanced Research Projects Agency-Energy has initiated projects to develop advanced cultivation technologies that enable the cost- and energy-efficient production of macroalgal biomass. Here, this study addresses the life-cycle greenhouse gas emissions and energy return on investment for five U.S. offshore macroalgae production systems designed for deployment at the thousand-hectare scale using a detailed module developed within the GREET life-cycle analysis model for this study. The carbon intensity of macroalgae production system designs, expressed as kg of carbon dioxide equivalent per dry metric ton of algae harvested, vary widely from 49 to 220 and confirm that biomass productivity has the highest degree of sensitivity across the model parameters tested. Regardless of the system designs, the upstream and combustion emissions from fuel use are the key contributor (over 45 %) to carbon intensity, indicating that the use of low-carbon fuels (e.g., renewable diesel) could further reduce greenhouse gas emissions. Further studies need to specify the market opportunity and specific product slates for macroalgae to provide a complete picture of the environmental impacts of macroalgal feedstock.

59 BASIC BIOLOGICAL SCIENCES↗

Reactor-Based Management of Used Nuclear Fuel: Assessment of Major Options

This paper discusses the current status of the ongoing Advanced Fuel Cycle Initiative (AFCI) program in the U.S. Department of Energy that is investigating the potential for using the processing and recycling of used nuclear fuel to improve radioactive waste management, including used fuel. A key element of the strategies is to use nuclear reactors for further irradiation of recovered chemical elements to transmute certain long-lived highly-radioactive isotopes into less hazardous isotopes. Both thermal and fast neutron spectrum reactors are being studied as part of integrated nuclear energy systems where separations, transmutation, and disposal are considered. Radiotoxicity is being used as one of the metrics for estimating the hazard of used fuel and the processing of wastes resulting from separations and recycle-fuel fabrication. Decay heat from the used fuel and/or wastes destined for disposal is used as a metric for use of a geologic repository. Results to date indicate that the most promising options appear to be those using fast reactors in a repeated recycle mode to limit buildup of higher actinides, since the transuranic elements are a key contributor to the radiotoxicity and decay heat. Using such an approach, there could be much lower environmental impact from the high-level waste as compared to direct disposal of the used fuel, but there would likely be greater generation of low-level wastes that will also require disposal. An additional potential waste management benefit is having the ability to tailor waste forms and contents to one or more targeted disposal environments (i.e., to be able to put waste in environments best-suited for the waste contents and forms).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Establishment of a Vertically Integrated Domestic Manufacturing Process for Production of Substrates Needed for Manufacture of Gas Diffusion Layers

In this project, AvCarb, LLC evaluated the baseline performance metrics of commercial carbon veils and their corresponding Gas Diffusion Layers (GDLs) with the goal of establishing an optimized, vertically integrated production system for wet-laid nonwoven substrates used in gas diffusion media for electrochemical energy storage and conversion devices. Mechanical testing and microstructural characterization were conducted and used to develop a multiscale computational model capable of simulating and predicting the performance of GDLs in fuel cells. Although the project successfully generated foundational transport and modeling data, it was terminated prior to identifying the critical GDL design parameters necessary for full optimization. The program aimed to improve carbon veil fabrication through enhanced fiber dispersion, fiber-fiber adhesion control, and improved web formation, enabling the production of high-quality, uniform substrates. Simulations were intended to guide mixing and solution delivery system design and process conditions, followed by production-scale trials to evaluate fiber dispersion, web uniformity, and mechanical robustness. At full deployment, the proposed production line would have been capable of producing approximately 650,000 m² of carbon veil annually. This capability remains strategically important, as the United States currently lacks a domestic source of wet-laid nonwoven carbon substrates that satisfy the stringent quality requirements for fuel-cell GDLs and electrolyzers representing an ongoing supply-chain vulnerability. Beyond supply-chain benefits, the project established a robust benchmarking dataset for existing commercial carbon veils while advancing next-generation material concepts targeting improved performance and manufacturing consistency.

Olson, Cynthia Lemay↗

Inexact convex relaxations for AC optimal power flow: Towards AC feasibility

Convex relaxations of AC optimal power flow (AC-OPF) problems have attracted significant interest as in several instances they provably yield the global optimum to the original non-convex problem. If, however, the relaxation is inexact, the obtained solution is not AC-feasible. The quality of the obtained solution is essential for several practical applications of AC-OPF, but detailed analyses are lacking in existing literature. Here, this paper aims to cover this gap. We provide an in-depth investigation of the solution characteristics when convex relaxations are inexact, we assess the most promising AC feasibility recovery methods for large-scale systems, and we propose two new metrics that lead to a better understanding of the quality of the identified solutions. We perform a comprehensive assessment on 96 different test cases, ranging from 14 to 3120 buses, and we show the following: (i) Despite an optimality gap of less than 1%, several test cases still exhibit substantial distances to both AC feasibility and local optimality and the newly proposed metrics characterize these deviations. (ii) Penalization methods fail to recover an AC-feasible solution in 15 out of 45 test cases. (iii) The computational benefits of warm-starting non-convex solvers have significant variation, but a computational speedup exists in over 75% of cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The SODA Approach: Leveraging High-Level Synthesis for Hardware/Software Co-design and Hardware Specialization: Invited

Novel "converged" applications combine phases of scientific simulation with data analysis and machine learning. Each computational phase can benefit from specialized accelerators. However, algorithms evolve so quickly that mapping them on existing accelerators is suboptimal or even impossible. This paper presents the SODA (Software Defined Accelerators) framework, a modular, multi-level, open-source, no-human-in-the-loop, hardware synthesizer that enables end-to-end generation of specialized accelerators. SODA is composed of SODA-Opt, a high-level frontend developed in MLIR that interfaces with domain-specific programming frameworks and allows performing system level design, and Bambu, a state-of-the-art high-level synthesis engine that can target different device technologies. The framework implements design space exploration as compiler optimization passes. We show how the modular, yet tight, integration of the high-level optimizer and lower-level HLS tools enables the generation of accelerators optimized for the computational patterns of converged applications. We then discuss some of the research opportunities that such a framework allows, including system-level design, profile driven optimization, and supporting new optimization metrics.

Bohm Agostini, Nicolas↗

Ordering Traces Logically to Identify Lateness in Parallel Programs

Event traces are a valuable tool for understanding the behavior of parallel programs. Automatically analyzing a large trace, however, especially without a specific objective, is difficult. We aid this process by extracting a trace’s logical structure, an ordering of events derived from their happened before relationships. From this perspective, we can calculate delays relative to peers rather than duration and determine where they begin and how they propagate. The logical structure also acts as a platform for comparing and clustering processes as well as showing communication patterns in a trace visualization. We present an algorithm for determining this idealized logical structure from a trace and develop metrics to quantify delays and differences among processes. We implement this in our novel trace visualizer, Ravel, and apply our approach to several applications, demonstrating the accuracy of our extracted structure and its utility in analyzing these codes.

97 MATHEMATICS AND COMPUTING↗

Biofuels and certification. A workshop at the Harvard Kennedy School of Government. Summary report

Liquid biofuels can provide a substitute for fossil fuels in the transportation sector. Many countries have mandated the use of biofuels, by creating targets for their use. If not implemented with care, however, actions that increase biofuel production can put upward pressure on food prices, increase greenhouse gas (GHG) emissions, and exacerbate degradation of land, forest, and water sources. A strong global biofuels industry will not emerge unless these environmental and social concerns are addressed. Interested parties around the world are actively debating the design and implementation of policies to meet the biofuel goals, particularly those established in the United States and Europe. In general, policy options for managing the potential risks and benefits of biofuel development should specify not only clear standards governing biofuel content and production processes, but also certification processes for verifying whether particular biofuels meet those standards, and specific metrics or indicators on which to base the certification. Historically, many standards in the energy and environment fields have ultimately been set or supported by governments. Many of the certification processes have been voluntary, carried out by independent third parties. The biofuels case is a young one, however, with questions of goals, standards, certification, and metrics still in interdependent flux. The workshop focused its discussions on certification issues, but found the discussions naturally reaching into ongoing debates regarding possible goals, standards, and metrics. Many countries are proposing that for a biofuel to qualify as contributing to government-mandated targets or goals, it must be certified to meet certain standards. These standards could be limited to the amount of GHG emitted in the production process or could include a number of other environmental sustainability concerns ranging from deforestation and biodiversity to water resources. While the threat to both forests and food supplies from increased biofuel production is real, it is not clear that setting broad sustainability standards and then requiring sellers to certify that all of those standards have been met is the best way to address these interconnected problems. In particular, if too many standards and related certification requirements are put in place too soon, this could constrain the development of a global biofuels market. In contrast, certification targeted at a specific and limited set of problems and designed with the flexibility to adjust to changes in policies and programs can enhance the public's acceptance of the biofuel option while protecting key social and environmental goals. A second set of questions revolves around the locus of responsibility for certifying whether biofuel production meets sustainability targets. Should the biofuel processing firms, third parties, or governments be responsible for certifying the production of biofuels? This question also elicited significant discussion. While it could be easier to have individual country governments assume the certification of production responsibility, some governments may not have the capacity to implement an effective certification process. Production facilities that comply with international standards should not be kept out of the market because of their government's inability to manage the process. The possible contribution to effective certification of third party organizations or public-private partnerships should not be underestimated.

09 BIOMASS FUELS↗

Factors Influencing Building Demand Flexibility

The U.S. Department of Energy’s National Roadmap for Grid-interactive Efficient Buildings (GEB) acknowledged that building demand flexibility (DF) is both an important strategy to decarbonizing the buildings sector and an important resource for meeting the changing needs of the electrical grid such as improving grid reliability. However, understanding the complexity and uncertainties in real building field performance of DF strategies is a large gap hindering stakeholders on both grid and buildings side to make investments on deploying such strategies. The research work in this report intended to advance understanding of the variability and influential factors in building demand flexibility. Adding such knowledge based on lab testing results and measured performance data from real buildings is an important contribution. The report uses standardized metrics and methods to quantify DF performance from field-measured DF datasets of two significant building groups of big-box retail and medium office buildings to present the challenge of building DF variability in multiple dimensions. The report presents findings related to how several key factors influence building demand flexibility from implementing a common, cost-effective DF control strategy (i.e., adjusting zone temperatures). The findings are supported by full-scale lab testing, field data analysis and simulation research. The authors also provided application-oriented recommendations to stakeholders such as building aggregators, utility program design professionals, sophisticated building portfolio owners, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Design Toolkit (MDT) Technical Documentation and Component Summaries

The Microgrid Design Toolkit (MDT) is a decision support software tool for microgrid designers to use during the microgrid design process. The models that support the two main capabilities in MDT are described. The first capability, the Microgrid Sizing Capability (MSC), is used to determine the size and composition of a new microgrid in the early stages of the design process. MSC is a mixed-integer linear program that is focused on developing a microgrid that is economically viable when connected to the grid. The second capability is focused on refining a microgrid design for operation in islanded mode. This second capability relies on two models: the Technology Management Optimization (TMO) model and Performance Reliability Model (PRM). TMO uses a genetic algorithm to create and refine a collection of candidate microgrid designs. It uses PRM, a simulation based reliability model, to assess the performance of these designs. TMO produces a collection of microgrid designs that perform well with respect to one or more performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Life-Cycle Cost Analysis Framework for Water Efficiency Measures

Life-Cycle Cost Analysis Framework for Water Efficiency Measures: Guidance Designed for Federal Agencies (hereafter referred to as “this report”) provides a technical framework for federal agencies to conduct a life-cycle cost analysis (LCCA) for water efficiency projects in accordance with 42 U.S.C. § 8253. This report leverages insights from the 2023 report, PNNL-34006, Water and Wastewater Annual Price Escalation Rates for Selected Cities Across the United States: 2023 Edition (Unger et al. 2023). The primary objective of this report is to provide a framework to assist federal agencies with evaluating the full economic impact of water efficiency projects by assessing both initial investments and long-term operational benefits. An LCCA can provide a comprehensive view of all costs associated with a water efficiency project, including initial investment, ongoing operations and maintenance (O&M), and eventual disposal or replacement, ensuring the most cost-effective solution is selected. The LCCA methodology outlined in this report enables users to compare base case scenarios with potential alternatives using a standardized present value approach. It incorporates key cost components such as energy, water and wastewater, installation, O&M, and equipment replacement. Additionally, the framework introduces relevant evaluation metrics, such as the net savings and the savings-to-investment ratio, to ensure that water efficiency measures are economically justified over the lifespan of the project. To support practical application, this report also describes various water efficiency strategies that may be analyzed using an LCCA, including plumbing retrofits, irrigation upgrades, alternative water use, and cooling system improvements. By applying this framework, federal agencies can ensure compliance with regulatory mandates while maximizing the return on investment and contributing to resilient water management practices. The information provided in this report is aligned with the Federal Energy Management Program (FEMP) life-cycle cost (LCC) methodology, as conveyed in National Institute of Standards and Technology (NIST) Handbook 135 (Kneifel and Webb 2022). This report is intended to provide relatively high-level guidance, acting as a complement to, rather than a substitute for, that resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

UP2 400 High Activity Oxide Legacy Waste Retrieval Project Scope and Progress-13048

The High Activity Oxide facility (HAO) reprocessed sheared and dissolved 4500 metric tons of light water reactor fuel the fuel of the emerging light water reactor spent fuel between 1976 and 1998. Over the period, approximately 2200 tons of process waste, composed primarily of sheared hulls, was produced and stored in a vast silo in the first place, and in canisters stored in pools in subsequent years. Upon shutdown of the facility, AREVA D and D Division in La Hague launched a thorough investigation and characterization of the silos and pools content, which then served as input data for the definition of a legacy waste retrieval and reconditioning program. Basic design was conducted between 2005 and 2007, and was followed by an optimization phase which lead to the definition of a final scenario and budget, 12% under the initial estimates. The scenario planned for the construction of a retrieval and reconditioning cell to be built on top of the storage silo. The retrieved waste would then be rinsed and sorted, so that hulls could subsequently be sent to La Hague high activity compacting facility, while resins and sludge would be cemented within the retrieval cell. Detailed design was conducted successfully from 2008 until 2011, while a thorough research and development program was conducted in order to qualify each stage of the retrieval and reconditioning process, and assist in the elaboration of the final waste package specification. This R and D program was defined and conducted as a response and mitigation of the major project risks identified during the basic design process. Procurement and site preparatory works were then launched in 2011. By the end of 2012, R and D is nearly completed, the retrieval and reconditioning process have been secured, the final waste package specification is being completed, the first equipment for the retrieval cell is being delivered on site, while preparation works are allowing to free up space above and around the silo, to allow for construction which is scheduled to being during the first semester of 2013. The elaboration of the final waste package is still undergoing and expected to be completed by then end of 2013, following some final elements of R and D required to demonstrate the full compatibility of the package with deep geological repository. The HAO legacy waste retrieval project is so far the largest such project entering operational phase on the site of La Hague. It is on schedule, under budget, and in conformity with the delivery requirements set by the French Safety Authority, as well as other stakeholders. This project paves the way for the successful completion of AREVA La Hague other legacy waste retrieval projects, which are currently being drafted or already in active R and D phase. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗