Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Rapid acquisition of data dense solid-state CPMG NMR spectral sets using multi-dimensional statistical analysis

The development of multi-dimensional statistical methods has been demonstrated on variable contact time (VCT) 29 Si{ 1 H} cross-polarization magic angle spinning (CP/MAS) data sets collected using Carr–Purcell–Meiboom–Gill (CPMG) type acquisition. These methods utilize the transformation of the collected 2D VCT data set into a 3D data set and use tensor-rank decomposition to extract the spectral components that vary as a function of transverse relaxation time ( T 2 ) and CP contact time. The result is a data dense spectral set that can be used to reconstruct CP/MAS spectra at any contact time with a high signal to noise ratio and with an excellent agreement to 29 Si{ 1 H} CP/MAS spectra collected using conventional acquisition. These CPMG data can be collected in a fraction of time that would be required to collect a conventional VCT data set. Here, we demonstrate the method on samples of functionalized mesoporous silica materials and show that the method can provide valuable surface specific information about their functional chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchronized Wireless Measurement of High-Voltage Power System Frequency Using Mobile Embedded Systems

This paper focuses on synchronized wireless measurement of high-voltage (HV) power system frequency using mobile embedded systems (MESs) integrated with a wireless electric field sensor (WEFS). Unlike traditional synchronized frequency measurement devices, which rely on potential transformers and current transformers physically connected to system elements, a WEFS is used to realize wireless signal acquisition in the vicinity of any HV apparatus. The MES performs real-time frequency estimation using a recursive discrete Fourier transform based algorithm. Network time protocol (NTP) is used for time synchronization, increasing the system flexibility by eliminating global positioning system reliance. An NTP-based synchronized sampling control method is proposed and implemented in MES to compensate the sampling time error caused by local time drift and division residue. The proposed system has the advantages of portability and lower cost, making it highly accessible and useful for a wide array of synchronized frequency measurement applications. Experiment results verify the accuracy and effectiveness of the proposed system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GNS Castor V/21 Headspace Gas Sampling 2014

Prior to performing an internal visual inspection, samples of the headspace gas of the GNS Castor V/21 cask were taken on June 12, 2014. These samples were taken in support of the CREIPI/Japanese nuclear industry effort to validate fuel integrity without visual inspection by measuring the 85 Kr content of the cask headspace

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Methods for detection of methyl-CpG dinucleotides

The invention provides methods for enriching methyl-CpG sequences from a DNA sample. The method makes use of conversion of cytosine residues to uracil under conditions in which methyl-cytosine residues are preserved. Additional methods of the invention enable to preservation of the context of me-CpG dinucleotides. The invention also provides a recombinant, full length and substantially pure McrA protein (rMcrA) for binding and isolation of DNA fragments containing the sequence 5'-C.sup.MeCpGG-3'. Methods for making and using the rMcrA protein, and derivatives thereof are provided.

59 BASIC BIOLOGICAL SCIENCES↗

Methods for detection of methyl-CpG dinucleotides

The invention provides methods for enriching methyl-CpG sequences from a DNA sample. The method makes use of conversion of cytosine residues to uracil under conditions in which methyl-cytosine residues are preserved. Additional methods of the invention enable to preservation of the context of me-CpG dinucleotides. The invention also provides a recombinant, full length and substantially pure McrA protein (rMcrA) for binding and isolation of DNA fragments containing the sequence 5'-C.sup.MeCpGG-3'. Methods for making and using the rMcrA protein, and derivatives thereof are provided.

59 BASIC BIOLOGICAL SCIENCES↗

Methods for detection of methyl-CpG dinucleotides

The invention provides methods for enriching methyl-CpG sequences from a DNA sample. The method makes use of conversion of cytosine residues to uracil under conditions in which methyl-cytosine residues are preserved. Additional methods of the invention enable to preservation of the context of me-CpG dinucleotides. The invention also provides a recombinant, full length and substantially pure McrA protein (rMcrA) for binding and isolation of DNA fragments containing the sequence 5'-C.sup.MeCpGG-3'. Methods for making and using the rMcrA protein, and derivatives thereof are provided.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray fluorescence microscopy methods for biological tissues

Abstract Synchrotron-based X-ray fluorescence microscopy is a flexible tool for identifying the distribution of trace elements in biological specimens across a broad range of sample sizes. The technique is not particularly limited by sample type and can be performed on ancient fossils, fixed or fresh tissue specimens, and in some cases even live tissue and live cells can be studied. The technique can also be expanded to provide chemical specificity to elemental maps, either at individual points of interest in a map or across a large field of view. While virtually any sample type can be characterized with X-ray fluorescence microscopy, common biological sample preparation methods (often borrowed from other fields, such as histology) can lead to unforeseen pitfalls, resulting in altered element distributions and concentrations. A general overview of sample preparation and data-acquisition methods for X-ray fluorescence microscopy is presented, along with outlining the general approach for applying this technique to a new field of investigation for prospective new users. Considerations for improving data acquisition and quality are reviewed as well as the effects of sample preparation, with a particular focus on soft tissues. The effects of common sample pretreatment steps as well as the underlying factors that govern which, and to what extent, specific elements are likely to be altered are reviewed along with common artifacts observed in X-ray fluorescence microscopy data.

Pushie, M. Jake (ORCID:0000000174945427)↗

Influence of thermal processing on magnetotransport characteristics of NdSr{sub 2}Mn{sub 2}O{sub 7+δ}

Highlights: • The NdSr{sub 2}Mn{sub 2}O{sub 7+δ} compounds with different oxygen non-stoichiometry were prepared. • According to XRD analysis, all the oxides were completely single-phase. • The strong competition between different types of magnetic exchange interactions was revealed. • The samples demonstrate semiconducting behavior over the explored temperature range. • A large negative magnetoresistance effect for all the compounds below 200 K was observed. - Abstract: Background: Influence of oxygen non-stoichiometry on magnetic and electric properties of the compounds has not almost been studied yet. Aim: Synthesis of a number of the NdSr{sub 2}Mn{sub 2}O{sub 7+δ} samples subjected to various thermal processing in air atmosphere and investigation of their structure, oxygen non-stoichiometry, electrical and magnetic properties. Method: The compounds obtained have been characterized by using X-ray diffraction (XRD) analysis, a modified gravimetric method, vibrating sample magnetometry (VSM) and standard DC four-probe method. Results: It was established that additional firing of the samples at different temperatures leads to essential changes in the oxygen non-stoichiometry. The noticeable magnetoresistance (MR) effect is observed for all the compounds below 200 K and increases monotonically as the temperature decreases. The MR values for the compounds as a function of oxygen content vary nonlinearly. The largest MR value of 380% at the 5 K and magnetic field of 7 T was achieved for the sample with the oxygen non-stoichiometry of δ = 0.03. Conclusions: The results observed are discussed in the assumption of ferromagnetic cluster formation in the compounds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-accuracy interferometer with a prism pair for measurement of the absolute refractive index of glass

We propose a variable-path interferometric technique for the measurement of the absolute refractive index of optical glasses. We use two interferometers to decide the ratio between changes in the optical path in a prism-shaped sample glass and in air resulting from displacement of the sample. The method allows precise measurements to be made without prior knowledge of the properties of the sample. The combined standard uncertainty of the proposed method is 1.6x10{sup -6}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First Four-Isotope Calibration of a Beta-Gamma Quad Detector

Beta-gamma coincidence detectors used for radioxenon detection are non-standard detector types, but still require energy and efficiency calibration. There are several methods that are commonly used to perform a detector calibration. ? NIST certified sealed source ? Relative measurement to compare to a calibrated detector ? Absolute efficiency calibration based on radioxenon gas samples. The method using actual radioxenon samples to make an absolute efficiency determination is the most desirable, but until recently it was not possible to produce all four isotopically pure radioxenon. The first four radioxenon isotope calibration is outlined here.

Cooper, Matthew W.↗

Imaging Hydrated Microbial Extracellular Polymers: Comparative Analysis by Electron Microscopy

Microbe-mineral and -metal interactions represent a major intersection between the biosphere and geosphere but require high-resolution imaging and analytical tools for investigating microscale associations. Electron microscopy has been used extensively for geomicrobial investigations and although used bona fide, the traditional methods of sample preparation do not preserve the native morphology of microbiological components, especially extracellular polymers. Herein, we present a direct comparative analysis of microbial interactions using conventional electron microscopy approaches of imaging at room temperature and a suite of cryo-electron microscopy methods providing imaging in the close-to-natural hydrated state. In situ, we observed an irreversible transformation of bacterial extracellular polymers during the traditional dehydration-based sample preparation that resulted in the collapse of hydrated gel-like EPS into filamentous structures. Dehydration-induced polymer collapse can lead to inaccurate spatial relationships and hence could subsequently affect conclusions regarding nature of interactions between microbial extracellular polymers and their environment.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluate Disposable Sample Chips and Complete the Evaluation of Sample Accuracy Through Evaluation of Chip Filling Methods

In FY-12, the glass sample chips were filled by capillary action when they were dipped into the solutions being sampled either by hand or by the robotic sampling system. Issues were noted at the end of FY-12 that many of the channels were not completely filling (10-15% of the 10 μl channels and up to 40% of the 2 μl channels). Therefore, testing was conducted in FY-13 on filling the glass sample chips by use of a flow-through header (Table 1). Results indicate flow through filling is better at completely filling the chip channels, although some amount of solution can be lost when the chip is removed from the filling header.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of a parasite-density based pooled targeted amplicon deep sequencing (TADS) method for molecular surveillance of Plasmodium falciparum drug resistance genes in Haiti

Sequencing large numbers of individual samples is often needed for countrywide antimalarial drug resistance surveillance. Pooling DNA from several individual samples is an alternative cost and time saving approach for providing allele frequency (AF) estimates at a population level. Using 100 individual patient DNA samples of dried blood spots from a 2017 nationwide drug resistance surveillance study in Haiti, we compared codon coverage of drug resistance-conferring mutations in four Plasmodium falciparum genes ( crt , dhps , dhfr , and mdr1 ), for the same deep sequenced samples run individually and pooled. Samples with similar real-time PCR cycle threshold (Ct) values (+/- 1.0 Ct value) were combined with ten samples per pool. The sequencing success for samples in pools were higher at a lower parasite density than the individual samples sequence method. The median codon coverage for drug resistance-associated mutations in all four genes were greater than 3-fold higher in the pooled samples than in individual samples. The overall codon coverage distribution for pooled samples was wider than the individual samples. The sample pools with < 40 parasites/μL blood showed more discordance in AF calls for dhfr and mdr1 between the individual and pooled samples. This discordance in AF estimation may be due to low amounts of parasite DNA, which could lead to variable PCR amplification efficiencies. Grouping samples with an estimated ≥ 40 parasites/μL blood prior to pooling and deep sequencing yielded the expected population level AF. Pooling DNA samples based on estimates of > 40 parasites/μL prior to deep sequencing can be used for rapid genotyping of a large number of samples for these four genes and possibly other drug resistant markers in population-based studies. As Haiti is a low malaria transmission country with very few mixed infections and continued chloroquine sensitivity, the pooled sequencing approach can be used for routine national molecular surveillance of resistant parasites.

Louha, Swarnali (ORCID:0000000207778507)↗

On the Importance of Accounting for Competing Risks in Pediatric Brain Cancer: II. Regression Modeling and Sample Size

Purpose: To accurately model the cumulative need for radiotherapy in trials designed to delay or avoid irradiation among children with malignant brain tumor, it is crucial to account for competing events and evaluate how each contributes to the timing of irradiation. An appropriate choice of statistical model is also important for adequate determination of sample size. Methods and Materials: We describe the statistical modeling of competing events (A, radiotherapy after progression; B, no radiotherapy after progression; and C, elective radiotherapy) using proportional cause-specific and subdistribution hazard functions. The procedures of sample size estimation based on each method are outlined. These are illustrated by use of data comparing children with ependymoma and other malignant brain tumors. The results from these two approaches are compared. Results: The cause-specific hazard analysis showed a reduction in hazards among infants with ependymoma for all event types, including Event A (adjusted cause-specific hazard ratio, 0.76; 95% confidence interval, 0.45-1.28). Conversely, the subdistribution hazard analysis suggested an increase in hazard for Event A (adjusted subdistribution hazard ratio, 1.35; 95% confidence interval, 0.80-2.30), but the reduction in hazards for Events B and C remained. Analysis based on subdistribution hazard requires a larger sample size than the cause-specific hazard approach. Conclusions: Notable differences in effect estimates and anticipated sample size were observed between methods when the main event showed a beneficial effect whereas the competing events showed an adverse effect on the cumulative incidence. The subdistribution hazard is the most appropriate for modeling treatment when its effects on both the main and competing events are of interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient sampling over rough energy landscapes with high barriers: A combination of metadynamics with integrated tempering sampling

In order to efficiently overcome high free energy barriers embedded in a complex energy landscape and calculate overall thermodynamics properties using molecular dynamics simulations, we developed and implemented a sampling strategy by combining the metadynamics with (selective) integrated tempering sampling (ITS/SITS) method. The dominant local minima on the potential energy surface (PES) are partially exalted by accumulating history-dependent potentials as in metadynamics, and the sampling over the entire PES is further enhanced by ITS/SITS. With this hybrid method, the simulated system can be rapidly driven across the dominant barrier along selected collective coordinates. Then, ITS/SITS ensures a fast convergence of the sampling over the entire PES and an efficient calculation of the overall thermodynamic properties of the simulation system. To test the accuracy and efficiency of this method, we first benchmarked this method in the calculation of ϕ − ψ distribution of alanine dipeptide in explicit solvent. We further applied it to examine the design of template molecules for aromatic meta-C—H activation in solutions and investigate solution conformations of the nonapeptide Bradykinin involving slow cis-trans isomerizations of three proline residues.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrasmall-angle X-ray scattering analysis of photonic crystal structure

The results of an ultrasmall-angle X-ray scattering study of iron(III) oxide inverse opal thin films are presented. The photonic crystals examined are shown to have fcc structure with amount of stacking faults varying among the samples. The method used in this study makes it possible to easily distinguish between samples with predominantly twinned fcc structure and nearly perfect fcc stacking. The difference observed between samples fabricated under identical conditions is attributed to random layer stacking in the self-assembled colloidal crystals used as templates for fabricating the inverse opals. The present method provides a versatile tool for analyzing photonic crystal structure in studies of inverse opals made of various materials, colloidal crystals, and three-dimensional photonic crystals of other types.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Differentiating supported platinum single atoms, clusters and nanoparticles by styrene hydrogenation

Supported metal catalysts often consist of metal sites ranging from nanoparticles to subnanometer clusters and single atoms. It remains a necessity to differentiate these sites to guide design of optimal catalysts. Here we report a simple method to assess the distribution of metal active sites in catalyst samples. The method takes the advantage of the structure sensitivity of styrene hydrogenation over titania supported platinum (Pt) catalysts with Pt aggregates varied from single atom to ~1.40 nm nanoparticles. The physicochemical properties were characterized by STEM, XPS, XANES, H2-TPR and CO-chemisorption measurements. The reactivity of Pt sites was quantified by styrene hydrogenation at ambient conditions. The nanometer-sized Pt clusters have significantly higher activity than Pt nanoparticles, sub-nanometer clusters or isolated single atoms. Additionally, the relationship between activity and structural/electronic properties of Pt sites influenced by particle sizes was discussed. Similar relationship was found in the carbon supported Pt catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-126: An Online Replanning Method for FFF Beams Without Couch Shift

Purpose: In a situation that couch shift for patient positioning is not preferred or prohibited (e.g., MR-Linac), segment aperture morphing (SAM) can address target dislocation and deformation. For IMRT/VMAT with flattening filter free (FFF) beams, however, SAM method would lead to an adverse translational dose effect due to the beam unflattening. Here we propose a new 2-step process to address both the translational effect of FFF beams and the target deformation. Methods: The replanning method consists of an offline and an online steps. The offline step is to create a series of pre-shifted plans (PSP) obtained by a so called “warm start” optimization (starting optimization from the original plan, rather from scratch) at a series of isocenter shifts with fixed distance (e.g. 2 cm, at x,y,z = 2,0,0 ; 2,2,0 ; 0,2,0; …;− 2,0,0). The PSPs all have the same number of segments with very similar shapes, since the warm-start optimization only adjusts the MLC positions instead of regenerating them. In the online step, a new plan is obtained by linearly interpolating the MLC positions and the monitor units of the closest PSPs for the shift determined from the image of the day. This two-step process is completely automated, and instantaneously fast (no optimization or dose calculation needed). The previously-developed SAM algorithm is then applied for daily deformation. We tested the method on sample prostate and pancreas cases. Results: The two-step interpolation method can account for the adverse dose effects from FFF beams, while SAM corrects for the target deformation. The whole process takes the same time as the previously reported SAM process (5–10 min). Conclusion: The new two-step method plus SAM can address both the translation effects of FFF beams and target deformation, and can be executed in full automation requiring no additional time from the SAM process. This research was supported by Elekta inc. (Crawley, UK)

60 APPLIED LIFE SCIENCES↗