Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Spatio-temporal Visualization for Environmental Decision Support

Traditional visualization of earth surface features has been addressed through visual exploration, analysis, synthesis, and presentation of observable geospatial data. However, characterizing the changes in their observable and unobservable properties of geospatial features is critical for planning and policy formulation. Recent approaches are addressing modeling and visualization of the temporal dynamics that describe observed and/or predicted physical and socioeconomic processes using vast volumes of earth observation (imagery and other geophysical) data from remote sensor networks. This paper provides an overview of selected geospatial modeling and simulation, exploratory analysis of earth observation data, and high performance visualization research at Oak Ridge National Laboratory for developing novel data driven approaches for geospatial knowledge discovery and visualization relevant to environmental decision support.

54 ENVIRONMENTAL SCIENCES↗

Measuring the thermal conductivity of hydrogels with a bidirectional 3w method

Hydrogels are soft, water-absorbing polymer materials with diverse applications in biomedicine and agriculture. Recently, hydrogels have been proposed to encapsulate water-soluble phase change materials which store energy in their latent heat of solidification. In these applications, the thermal conductivity of these materials affects their performance. Few methods exist for measuring the thermal conductivity of small quantities of hydrogels. Here, we describe an implementation of the bidirectional 3w technique to measure the thermal conductivity of hydrogels with particular attention to their moisture content. Our implementation of the technique can probe sample volumes as little as ~20 mL and yields the thermal conductivity without requiring fitting of additional thermal parameters. We numerically simulate 3w sensor designs with frequency-domain 3-D models to quantify and reduce errors introduced by the choice of substrate and insulation layer thickness. Frequencies in the ~1−20 Hz range yield less error for the materials considered here. We verify our setup with measurements on water and report values for polyacrylamide and poly(2-acrylamido-2-methylpropane sulfonic acid) (PAMPS) hydrogels. Our swollen hydrogels exhibited thermal conductivities nearly equivalent to water, 0.6 W m-1 K-1, and we estimate thermal conductivities of 0.43 and 0.42 W m-1 K-1 for neat polyacrylamide and PAMPS, respectively. Finally, we estimate an error of ±7%, consistent with other 3ω methods, with the largest error coming from the sensor calibration. We find our implementation of the bidirectional 3w method gives reasonable results and can be employed for prototyping soft materials relevant for thermal storage.

3-omega, thermal conductivity, hydrogel, moisture ↗

Holographic sensors for diagnostics of solution components

The properties of holographic sensors of two types are studied. The sensors are based on a three-dimensional polymer-network matrix of copolymers of acrylamide, acrylic acid (which are sensitive to the medium acidity and bivalent metal ions) and aminophenylboronic acid (sensitive to glucose). It is found that a change in the ionic composition of a solution results in changes in the distance between layers and in the diffraction efficiency of holograms. Variations in the shape of spectral lines, which are attributed to the inhomogeneity of a sensitive layer, and nonmonotonic changes in the emulsion thickness and diffraction efficiency were observed during transient processes. The composition of the components of a hydrogel medium is selected for systems which can be used as a base for glucose sensors with the mean holographic response in the region of physiological glucose concentration in model solutions achieving 40 nm/(mmol L{sup -1}). It is shown that the developed holographic sensors can be used for the visual and instrumental determination of the medium acidity, alcohol content, ionic strength, bivalent metal salts and the quality of water, in particular, for drinking. (laser applications and other topics in quantum electronics)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent Progress on Surface Water Quality Models Utilizing Machine Learning Techniques

Surface waterbodies are heavily exposed to pollutants caused by natural disasters and human activities. Empowering sensor technologies in water quality monitoring, sufficient measurements have become available to develop machine learning (ML) models. Numerous ML models have quickly been adopted to predict water quality indicators in various surface waterbodies. This paper reviews 78 recent articles from 2022 to October 2024, categorizing water quality models utilizing ML into three groups: Point-to-Point (P2P), which estimates the current target value based on other measurements at the same time point; Sequence-to-Point (S2P), which utilizes previous time series data to predict the target value at one time point ahead; and Sequence-to-Sequence (S2S), which uses previous time series data to forecast sequential target values in the future. The ML models used in each group are classified and compared according to water quality indicators, data availability, and model performance. Widely used strategies for improving performance, including feature engineering, hyperparameter tuning, and transfer learning, are recognized and described to enhance model effectiveness. The interpretability limitations of ML applications are discussed. This review provides a perspective on emerging ML for surface water quality models.

machine learning (ML)↗

The Sandia MEMS passive shock sensor : FY07 maturation activities.

This report describes activities conducted in FY07 to mature the MEMS passive shock sensor. The first chapter of the report provides motivation and background on activities that are described in detail in later chapters. The second chapter discusses concepts that are important for integrating the MEMS passive shock sensor into a system. Following these two introductory chapters, the report details modeling and design efforts, packaging, failure analysis and testing and validation. At the end of FY07, the MEMS passive shock sensor was at TRL 4.

42 ENGINEERING↗

Non-shock initiation model for explosive families : experimental results.

The 'DaMaGe-Initiated-Reaction' (DMGIR) computational model has been developed to predict the response of high explosives to non-shock mechanical insults. The distinguishing feature of this model is the introduction of a damage variable, which relates the evolution of damage to the initiation of a reaction in the explosive, and its growth to detonation. Specifically designed experiments were used to study the initiation process of each explosive family with embedded shock sensors and optical diagnostics. The experimental portion of this model development began with a study of PBXN-5 to develop DMGIR model coefficients for the rigid plastic bonded family, followed by studies of the cast, and bulk-moldable explosive families. The experimental results show an initiation mechanism that is related to input energy and material damage, with well defined initiation thresholds for each explosive family. These initiation details will extend the predictive capability of the DMGIR model from the rigid family into the cast and bulk-moldable families.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Volcano infrasound: progress and future directions

Over the past two decades (2000–2020), volcano infrasound (acoustic waves with frequencies less than 20 Hz propagating in the atmosphere) has evolved from an area of academic research to a useful monitoring tool. As a result, infrasound is routinely used by volcano observatories around the world to detect, locate, and characterize volcanic activity. It is particularly useful in confirming subaerial activity and monitoring remote eruptions, and it has shown promise in forecasting paroxysmal activity at open-vent systems. Fundamental research on volcano infrasound is providing substantial new insights on eruption dynamics and volcanic processes and will continue to do so over the next decade. The increased availability of infrasound sensors will expand observations of varied eruption styles, and the associated increase in data volume will make machine learning workflows more feasible. More sophisticated modeling will be applied to examine infrasound source and propagation effects from local to global distances, leading to improved infrasound-derived estimates of eruption properties. Future work will use infrasound to detect, locate, and characterize moving flows, such as pyroclastic density currents, lahars, rockfalls, lava flows, and avalanches. Infrasound observations will be further integrated with other data streams, such as seismic, ground- and satellite-based thermal and visual imagery, geodetic, lightning, and gas data. The volcano infrasound community should continue efforts to make data and codes accessible and to improve diversity, equity, and inclusion in the field. In summary, the next decade of volcano infrasound research will continue to advance our understanding of complex volcano processes through increased data availability, sensor technologies, enhanced modeling capabilities, and novel data analysis methods that will improve hazard detection and mitigation.

58 GEOSCIENCES↗

Fluorescence Enhancement in the Solid State by Isolating Perylene Fluorophores in Metal–Organic Frameworks

Polycyclic aromatic hydrocarbons such as perylene, pyrene, and their derivatives are highly emissive fluorophores in solution. Furthermore, the practical applications of these materials in the field of molecular electronic and light emitting devices are often hindered by self-quenching effects due to the formation of non-fluorescent aggregates in concentrated solutions or in the solid state. Herein, we demonstrate that aggregation caused quenching of perylenes can be minimalized by molecular incorporation into metalorganic frameworks (MOFs). This study utilized a stable Zr 6 cluster-based MOF, UiO-67, as a matrix. Linear linkers containing the photo-responsive moieties were designed and incorporated into the parent UiO-67 scaffold through the partially replacement of the non-fluorescent linkers of a similar length, forming mixed-linker MOFs. Here, the average distance between perylene moieties was tuned by changing the linker ratios, thus controlling the fluorescence intensity, emission wavelength, and quantum yield. Molecular modeling was further adopted to correlate the number of isolated perylene linkers within the framework to the ratio between the two linkers, therefore rationalizing the change in the observed fluorescent properties. Taking advantage of the tunable fluorescence, inherent porosity, and high chemical stability of this MOF platform, it was applied as a fluorescent sensor for oxygen detection in the gas phase, a model reaction, showing fast response and good recyclability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combinations of NIR, Raman spectroscopy and physicochemical measurements for improved monitoring of solvent extraction processes using hierarchical multivariate analysis models

The reliability of chemical processes can be greatly improved by implementing inline monitoring systems. Combining multivariate analysis with non-destructive sensors can enhance the process without interfering with the operation. Here, we present here hierarchical models using both principal component analysis and partial least square analysis developed for different chemical components representative of solvent extraction process streams. A training set of 380 samples and an external validation set of 95 samples were prepared and Near infrared and Raman spectral data as well as conductivity under variable temperature conditions were collected. The results from the models indicate that careful selection of the spectral range is important. By compressing the data through Principal Component Analysis (PCA), we lower the rank of the data set to its most dominant features while maintaining the key principal components to be used in the regression analysis. Within the studied data set, concentration of five chemical components were modeled; total nitrate (NO 3 - ), total acid (H + ), neodymium (Nd 3+ ), sodium (Na + ), and ionic strength (I.S.). The best overall model prediction for each of the species studied used a combined data set comprised of complementary techniques including NIR, Raman, and conductivity. Finally, our study shows that chemometric models are powerful but requires significant amount of carefully analyzed data to capture variations in the chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors [Dissertation]

Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal’s intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-GHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (μm-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor’s architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perót displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.

Engineering(42)↗

Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors

Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal's intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-MHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (?m-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor's architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perot displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.

42 ENGINEERING↗

Sensor Selection for MIMO Vibration: Summary Slides [Slides]

Summary: Sensor selection approach for MIMO testing was defined and demonstrated on a model of a practical system. Laboratory response obtained using the approach matched the field response well. Information about how many control sensors, and where to locate sensors can be gleaned from the approach.

42 ENGINEERING↗

The Second Skin: A Wearable Sensor Suite that Enables Real-Time Human Biomechanics Tracking Through Deep Learning

Objective: Real-time determination of human kinematics and kinetics could advance biomechanics research and enable valuable applications of biofeedback and generalizable exoskeleton control. Here, this work aims to investigate a taskindependent, user-independent method for obtaining precise realtime joint state estimation across lower-body joints during a wide variety of tasks. Methods: We developed a generalizable sensing approach using a suit comprised of inertial measurement units (IMUs) and pressure insoles. With the suit, we collected a dataset of 33 tasks commonly performed during construction and hazardous waste cleanup (N = 10). We then trained deep learning user-independent, task-agnostic models to estimate joint lowerbody kinematics and dynamics using only worn sensor data. We likewise computed joint kinematics and dynamics analytically from sensor data to serve as a comparison tool for model results. Results: Our models achieved overall angle estimation root-meansquared-errors (RMSE) of 6.56±.92°, 8.60±1.01°, 7.58±.89°, and 6.00±.73° compared to 13.9±.1.3°, 15.31±1.0°, 10.76±.70°, and 7.56±.48° via analytical methods at the lower back, hip, knee, and ankle, respectively. Likewise, our models achieved overall normalized moment estimation RMSEs of .207±.069 Nm/kg, .242±.044 Nm/kg, .202±.038 Nm/kg, and .193±.034 Nm/kg compared to .306±.036 Nm/kg, .407±.021 Nm/kg, 1.18 ±.022 Nm/kg, and 1.73±.071 Nm/kg via analytical methods at the lower back, hip, knee, and ankle, respectively. Conclusion: These results are comparable to other state-of-the-art wearable sensing systems, establishing deep learning as a viable sensing approach that generalizes to new users and tasks. Significance: This work shows promise for enabling accurate real-world biomechanical data collection and enhancement of biofeedback systems and wearable robot control.

Casey, Ryan T. F. [Georgia Institute of Technology↗

Modeling Urban Scenarios & Experiments: Fort Indiantown Gap Data Collections Summary and Analysis

This report summarizes experimental radiation detector, contextual sensor, weather, and global positioning system (GPS) data collected to inform and validate a comprehensive, operational radiation transport modeling framework to evaluate radiation detector system and algorithm performance. This framework will be used to study the influence of systematic effects (such as geometry, background activity, background variability, environmental shielding, etc.) on detector responses and algorithm performance using synthetic time series data. This work consists of performing data collection campaigns at a canonical, controlled environment for complete radiological characterization to help construct and benchmark a high-fidelity model with quantified system geometries, detector response functions, and source terms for background and threat objects. This data also provides an archival, benchmark dataset that can be used by the radiation detection community. The data reported here spans four data collection campaigns conducted between May 2015 and September 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small satellite attitude determination based on GPS/IMU data fusion

In this paper, we present the mathematical models and algorithms that describe the problem of attitude determination for a small satellite using measurements from three angular rate sensors (ARS) and aiding measurements from multiple GPS receivers/antennas rigidly attached to the platform of the satellite.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative study of 0° X-cut and Y + 36°-cut lithium niobate high-voltage sensing

A comparison study between Y + 36° and 0° X-cut lithium niobate (LiNbO{sub 3}) was performed to evaluate the influence of crystal cut on the acoustic propagation to realize a piezoelectric high-voltage sensor. The acoustic time-of-flight for each crystal cut was measured when applying direct current (DC), alternating current (AC), and pulsed voltages. Results show that the voltage-induced shift in the acoustic wave propagation time scaled quadratically with voltage for DC and AC voltages applied to X-cut crystals. For the Y + 36° crystal, the voltage-induced shift scales linearly with DC voltages and quadratically with AC voltages. When applying 5 μs voltage pulses to both crystals, the voltage-induced shift scaled linearly with voltage. For the Y + 36° cut, the voltage-induced shift from applying DC voltages ranged from 10 to 54 ps and 35 to 778 ps for AC voltages at 640 V over the frequency range of 100 Hz–100 kHz. Using the same conditions as the Y + 36° cut, the 0° X-cut crystal sensed a shift of 10–273 ps for DC voltages and 189–813 ps for AC voltage application. For 5 μs voltage pulses, the 0° X-cut crystal sensed a voltage induced shift of 0.250–2 ns and the Y + 36°-cut crystal sensed a time shift of 0.115–1.6 ns. This suggests a frequency sensitive response to voltage where the influence of the crystal cut was not a significant contributor under DC, AC, or pulsed voltage conditions. The measured DC data were compared to a 1-D impedance matrix model where the predicted incremental length changed as a function of voltage. When the voltage source error was eliminated through physical modeling from the uncertainty budget, the combined uncertainty of the sensor (within a 95% confidence interval) decreased to 0.0033% using a Y + 36°-cut crystal and 0.0032% using an X-cut crystal for all the voltage conditions used in this experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗