Search NASA⌕ Search

SEARCH · Search NASA

Results for “simulator study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Impact of Real-Time Image Gating on Spot Scanning Proton Therapy for Lung Tumors: A Simulation Study

Purpose: To investigate the effectiveness of real-time-image gated proton beam therapy for lung tumors and to establish a suitable size for the gating window (GW). Methods and Materials: A proton beam gated by a fiducial marker entering a preassigned GW (as monitored by 2 fluoroscopy units) was used with 7 lung cancer patients. Seven treatment plans were generated: real-time-image gated proton beam therapy with GW sizes of ±1, 2, 3, 4, 5, and 8 mm and free-breathing proton therapy. The prescribed dose was 70 Gy (relative biological effectiveness)/10 fractions to 99% of the target. Each of the 3-dimensional marker positions in the time series was associated with the appropriate 4-dimensional computed tomography phase. The 4-dimensional dose calculations were performed. The dose distribution in each respiratory phase was deformed into the end-exhale computed tomography image. The D99 and D5 to D95 of the clinical target volume scaled by the prescribed dose with criteria of D99 >95% and D5 to D95 <5%, V20 for the normal lung, and treatment times were evaluated. Results: Gating windows ≤ ±2 mm fulfilled the CTV criteria for all patients (whereas the criteria were not always met for GWs ≥ ±3 mm) and gave an average reduction in V20 of more than 17.2% relative to free-breathing proton therapy (whereas GWs ≥ ±4 mm resulted in similar or increased V20). The average (maximum) irradiation times were 384 seconds (818 seconds) for the ±1-mm GW, but less than 226 seconds (292 seconds) for the ±2-mm GW. The maximum increased considerably at ±1-mm GW. Conclusion: Real-time-image gated proton beam therapy with a GW of ±2 mm was demonstrated to be suitable, providing good dose distribution without greatly extending treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synchrotron experiment and simulation studies of magnesium-steel interface manufactured by impact welding

The effective weight reduction in the automotive industry by the wide adoption of lightweight magnesium (Mg) alloys demands high-quality joint between magnesium alloys and massively-used steels in order to wring the excess weight with strength and safety assurance. However, Mg-steel joint is difficult to achieve because there is no mutual solubility between magnesium and steel and huge disparity in physical properties. An impact-based welding method recently showed successful Mg-steel joining. In this work, the characteristics of Mg-steel interface joined by the impact welding method were investigated. Synchrotron high-energy X-ray computed tomography and diffraction were applied to characterize the microstructure across Mg-steel interface. Results revealed a deposit layer formed at the joint interface where Fe-rich particles spread deep into the Mg matrix. High-resolution 3D morphology of Mg-steel interface demonstrated the trapped pores and cracks inside the deposit layer. Finally, the formation of the deposit layer and the void/cracking evolution were analyzed by using finite element models. These findings provide insights into the immiscible Mg-steel joining process.

36 MATERIALS SCIENCE↗

Simulation studies related to the particle identification by the forward and backward RICH detectors at Electron Ion Collider

The Electron-Ion collider (EIC) will be the ultimate facility to study the dynamics played by colored quarks and gluons in the phenomenology of nucleons and nuclei, described by Quantum Chromodynamics. The physics programs will greatly rely on efficient particle identification (PID) in both the forward and the backward regions. The forward and the backward RICHes of the EIC have to be able to cover wide acceptance and momentum ranges; in the forward region a dual radiator RICH (dRICH) is foreseen and in the backward region a proximity-focusing RICH can be foreseen to be employed. The geometry and the performance studies of the dRICH have been performed as prescribed in the EIC Yellow Report using the ATHENA software framework. Furthermore, this part of our work reports the effort following the call for EIC detector proposal and the studies related to the forward and the backward RICH performance. In the forward region, the dRICH performance showed a pion- kaon separation from around 1 GeV/c to 50 GeV/c at a three sigma level; the proximity focusing RICH (pfRICH) foreseen for the backward region can reach three sigma separation up to 3 GeV/c for e/$π$ and up to 10 GeV/c for $π$/K mass hypotheses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Gulf Stream energy resources: A 30-year high-resolution simulation study

The strength and proximity of the Gulf Stream (GS) along the U.S. coast offers opportunities for marine energy extraction. Leveraging high-resolution (up to 400 m) long-term (30-year) hindcasts based on an unstructured grid model, this study characterizes the energy potential of the GS in two viable locations: the Florida Straits (FS) and Cape Hatteras (CH). Results reveal distinct characteristics in the kinetic energy flux (KEF) and kinetic energy density (KED) for the two regions. The 30-year mean KEF at CH is 27.50 GW, surpassing the 19.74 GW estimated for the FS, which is attributed to the wider cross-section of the GS in CH. Additionally, CH exhibits higher KEF variability due to GS’s larger path shifts and meanders. Estimated KEDs at ADCP site locations reach up to 2,908 W/m 2 in the FS and 1,512 W/m 2 in the CH at a depth of 20 m. High-energy zones are closer to shore in the FS, whereas energy-rich areas at CH are located further offshore. A depth-based KED analysis shows significant decreases across typical energy extraction depths (20 to 100 m), with reductions up to 44%. Finally, this study provides high-resolution resource characterization, forming a foundation for optimized site selection and marine hydrokinetic system design.

16 TIDAL AND WAVE POWER↗