Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Development of a series of Korean pediatric and adult head computational phantoms and application to nuclear medicine dosimetry - Paper 26

Over the past decades, advances in Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) imaging techniques and an increasing number of new radiopharmaceuticals have resulted in a surge of neuroimaging applications in nuclear medicine on pediatric and adult patients. It is not feasible to directly measure the absorbed dose to the organs of the human body from nuclear medicine procedures. The formalism of the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine has been adopted as the calculation method to estimate radiation dose to target organs from radionuclides distributed in source organs. The absorbed dose to a target organ from different types of radionuclides distributed within source organs can be estimated by the products of the time-integrated activity in each source region and organ dose conversion coefficients, called S values (Gy/MBq-s). S values are computed from a comprehensive set of Specific Absorbed Fraction (SAF), which are calculated from computational human phantoms with realistic anatomical structures coupled with Monte Carlo transport technique. The current SAF data for pediatric and adult head and brain dosimetry is based on a series of stylized computational phantoms. However, dosimetric errors caused by the unrealistic anatomy of stylized phantoms in internal dosimetry calculations have been reported by several studies. In the current study, we developed a series of realistic computational head phantoms representing 6, 9, 12, 15, and 22-year-old standard Korean males, and computed a comprehensive set of SAFs using the phantoms coupled with Monte Carlo transport technique. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

White light Z-scan measurements of ultrafast optical nonlinearity in reduced graphene oxide nanosheets in the 400–700 nm region

Wavelength dispersion of optical power limiting is an important factor to be considered while designing potential optical limiters for laser safety applications. We report the observation of broadband, ultrafast optical limiting in reduced graphene oxide (rGO), measured by a single open aperture Z-scan using a white light continuum (WLC) source. WLC Z-scan is fast when the nonlinearity is to be measured over broad wavelength ranges, and it obviates the need for an ultrafast tunable laser making it cost-economic compared to conventional Z-scan. The nonlinearity arises from nondegenerate two-photon absorption, owing mostly to the crystallinity and extended π conjugation of rGO.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coded-mask-based wavefront sensing technique for APS nanofocusing beamline diagnostics

Here, we extend our recently developed coded-mask wavefront sensing technique to enable single-shot measurements of nanofocused x-ray beams. This method accurately reconstructs the focal beam profile by backpropagating the wavefront measured downstream of the beam focus. To validate its performance, we benchmarked it against the conventional fluorescence wire scan method, successfully measuring ∼120 nm focal spots at the 28-ID-B beamline of the Advanced Photon Source using a polymeric compound refractive lens. The results highlight the effectiveness of coded-mask wavefront sensing for high-precision beam profiling and its application as a real-time wavefront monitoring tool.

Shi, Xianbo [Argonne National Laboratory (ANL), Ar↗

The high-energy X-ray spectrum of the Crab Nebula observed from OSO-8

Results are reported for a measurement of the X-ray spectrum of the Crab Nebula over the energy range from 20 to 500 keV with a scintillation spectrometer aboard the OSO-8 satellite. A time-averaged spectrum of the nebula is presented which includes the average intensity of the X-ray pulsar NP 0532. The photon spectrum is shown to be well-fitted by a power law with a constant of approximately 4.19, a weighted mean energy of 39.1 keV, and a spectral index of about 2.00. No evidence is found for day-to-day variations in the spectrum of the source. The spectrum obtained is taken as evidence for the single power-law character of the Crab Nebula spectrum out to at least 200 keV and probably to as high an energy as 500 keV.

Dolan, J. F.↗

Positron-electron annihilation radiation from the Galactic Center

Evidence and arguments are presented supporting the theory that the 0.511 MeV line observed from the Galactic Center stems from photon-photon pair production near a black hole with a mass not greater than approximately 500 solar masses. Observations are reviewed and the subsequent implications on the annihilation site and the positron source are discussed. Because of the variations and line width of the e(+) - e(-) annihilation radiation from the Galactic Center, positrons must essentially be produced by a single source and annihilate in an ambient gas of density greater than 10 to the 5th/cu cm, an ionization fraction greater than 10 percent, a temperature less than 5 x 10 to the 4th K, and be confined to a region of size less than 10 to the 18th cm. Such conditions may exist in warm clouds and other IR sources within the central parsec of the Galaxy.

Ramaty, R.↗

A novel synthetic single crystal diamond device for in vivo dosimetry

Purpose: Aim of the present work is to evaluate the synthetic single crystal diamond Schottky photodiode developed at the laboratories of “Tor Vergata” University in Rome in a new dosimeter configuration specifically designed for offline wireless in vivo dosimetry (IVD) applications. Methods: The new diamond based dosimeter, single crystal diamond detector (SCDD-iv), consists of a small unwired detector and a small external reading unit that can be connected to commercial electrometers for getting the detector readout after irradiation. Two nominally identical SCDD-iv dosimeter prototypes were fabricated and tested. A basic dosimetric characterization of detector performances relevant for IVD application was performed under irradiation with {sup 60}Co and 6 MV photon beams. Preirradiation procedure, response stability, short and long term reproducibility, leakage charge, fading effect, linearity with dose, dose rate dependence, temperature dependence, and angular response were investigated. Results: The SCDD-iv is simple, with no cables linked to the patient and the readout is immediate. The range of response with dose has been tested from 1 up to 12 Gy; the reading is independent of the accumulated dose and dose rate independent in the range between about 0.5 and 5 Gy/min; its temperature dependence is within 0.5% between 25 and 38 °C, and its directional dependence is within 2% from 0° to 90°. The combined relative standard uncertainty of absorbed dose to water measurements is estimated lower than the tolerance and action level of 5%. Conclusions: The reported results indicate the proposed novel offline dosimeter based on a synthetic single crystal diamond Schottky photodiode as a promising candidate for in vivo dosimetry applications with photon beams.

07 ISOTOPE AND RADIATION SOURCES↗

Observation of Long-Lived UV-Induced Fluorescence from Environmental Materials Using the HVeV Detector as Developed for SuperCDMS

Here, we describe recent experiments using a SuperCDMS HVeV single-charge sensitive detector illuminated with an ultraviolet LED (275 nm) and a monochromatic laser(650 nm) using a dual fiber optic system installed in a small dilution refrigerator at Stanford University. We observed a population of fluorescence background events after UV exposure but not after exposure to the laser source. The fluorescence was likely due to scattered UV photons absorbed outside the detector. We discuss the possibility of fluorescence being a contributor to the low energy excess background observed in above-ground Dark Matter experiments.

36 MATERIALS SCIENCE↗

Locally defined quantum emission from epitaxial few-layer tungsten diselenide

Recently, single photons have been observed emanating from point defects in two-dimensional (2D) materials including WSe 2 , WS 2 , hexagonal-BN, and GaSe, with their energy residing in the direct electronic bandgap. Here, we report single photon emission from a nominal weakly emitting indirect bandgap 2D material through deterministic strain induced localization. A method is demonstrated to create highly spatially localized and spectrally well-separated defect emission sites in the 750–800 nm regime in a continuous epitaxial film of few-layer WSe 2 synthesized by a multistep diffusion-mediated gas source chemical vapor deposition technique. To separate the effects of mechanical strain from the substrate or dielectric-environment induced changes in the electronic structure, we created arrays of large isotropically etched ultrasharp silicon dioxide tips with spatial dimensions on the order of 10 μm. We use bending based on the small radius of these tips—on the order of 4 nm—to impart electronic localization effects through morphology alone, as the WSe 2 film experiences a uniform SiO 2 dielectric environment in the device geometry chosen for this investigation. When the continuous WSe 2 film was transferred onto an array of SiO 2 tips, an ~87% yield of localized emission sites on the tips was observed. The outcomes of this report provide fundamental guidelines for the integration of beyond-lab-scale quantum materials into photonic device architectures for all-optical quantum information applications.

36 MATERIALS SCIENCE↗

Intensified Tpx3Cam, a fast data-driven optical camera with nanosecond timing resolution for single photon detection in quantum applications

Here we describe a fast data-driven optical camera, Tpx3Cam, with nanosecond scale timing resolution and 80 Mpixel/sec throughput. After the addition of intensifier, the camera is single photon sensitive with quantum efficiency determined primarily by the intensifier photocathode. The single photon performance of the camera was characterized with results on the gain, timing resolution and afterpulsing reported here. The intensified camera was successfully used for measurements in a variety of applications including quantum applications. As an example of such application, which requires simultaneous detection of multiple photons, we describe registration of photon pairs from the spontaneous parametric down-conversion source in a spectrometer. We measured the photon wavelength and timing with respective precisions of 0.15 nm and 3 ns, and also demonstrated that the two photons are anti-correlated in energy.

79 ASTRONOMY AND ASTROPHYSICS↗

GAMMA-RAY FLARING ACTIVITY FROM THE GRAVITATIONALLY LENSED BLAZAR PKS 1830–211 OBSERVED BY Fermi LAT

The Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope routinely detects the MeV-peaked flat-spectrum radio quasar PKS 1830–211 (z = 2.507). Its apparent isotropic γ-ray luminosity (E > 100 MeV), averaged over ∼3 years of observations and peaking on 2010 October 14/15 at 2.9 × 10{sup 50} erg s{sup –1}, makes it among the brightest high-redshift Fermi blazars. No published model with a single lens can account for all of the observed characteristics of this complex system. Based on radio observations, one expects time-delayed variability to follow about 25 days after a primary flare, with flux about a factor of 1.5 less. Two large γ-ray flares of PKS 1830–211 have been detected by the LAT in the considered period, and no substantial evidence for such a delayed activity was found. This allows us to place a lower limit of about 6 on the γ-ray flux ratio between the two lensed images. Swift XRT observations from a dedicated Target of Opportunity program indicate a hard spectrum with no significant correlation of X-ray flux with the γ-ray variability. The spectral energy distribution can be modeled with inverse Compton scattering of thermal photons from the dusty torus. The implications of the LAT data in terms of variability, the lack of evident delayed flare events, and different radio and γ-ray flux ratios are discussed. Microlensing effects, absorption, size and location of the emitting regions, the complex mass distribution of the system, an energy-dependent inner structure of the source, and flux suppression by the lens galaxy for one image path may be considered as hypotheses for understanding our results.

79 ASTRONOMY AND ASTROPHYSICS↗

Recent developments in microtomography at GeoSoilEnviroCARS

A facility for x-ray computed microtomography (CMT) is operating as a national user facility for earth and environmental sciences research on the bending magnet beamline at the GeoSoilEnviroCARS sector at the Advanced Photon Source (APS). The APS bending magnet has a critical energy of 20 keV, and thus provides high flux at photon energies up to 100 keV, making it well suited to imaging a wide range of earth materials up to several cm in size. The beamline is equipped with a Si (111) double-crystal monochromator covering the energy range from 5 to 70 keV with beam sizes up to 50mm wide and 6mm high. The transmitted x-rays are imaged with a single crystal YAG or CdWO{sub 4} scintillator, a microscope objective and a 1300 x 1030 pixel 12-bit 5MHz CCD detector. The maximum spatial resolution is under 1.5 {micro}m in both the transmission radiographs and the reconstructed slices. Data collection times for full 3-D datasets range from 5-60 minutes. This facility has been used for a wide range of studies, including multiphase fluids in porous media, high-pressure studies, meteorites, and hyper-accumulating plants. We present recent technical improvements in the system, which include improved optics for samples larger than 5mm, significant reduction of ring artifacts, and correction of mechanical errors in the rotation stage.

43 PARTICLE ACCELERATORS↗

Is the Rapid Decay Phase from High Latitude Emission?

There is good observationnal evidence that the Steep Decay Phase (SDP) that is observed in most Swift GRBs is the tail of the prompt emission. The most popular model to explain the SDP is Hight Latitude Emission (HLE). Many models for the prompt emission give rise to HLE, like the popular internal shocks (IS) model, but some models do not, such as sporadic magnetic reconnection events. Knowing if the SDP is consistent with HLE would thus help distinguish between different prompt emission models. In order to test this, we model the prompt emission (and its tail) as the sum of independent pulses (and their tails). A single pulse is modeled as emission arising from an ultra-relativistic thin spherical expanding shell. We obtain analytic expressions for the flux in the IS model with a Band function spectrum. We find that in this framework the observed spectrum is also a Band function, and naturally softens with time. The decay of the SDP is initially dominated by the tail of the last pulse, but other pulses can dominate later. Modeling several overlapping pulses as a single broader pulse would overestimates the SDP flux. One should thus be careful when testing the HLE.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-E-17A-11: In-Phantom Detector Response in a Kilovoltage X-Ray Beam

Purpose: To investigate changes in detector response in a kilovoltage x-ray beam as a function of depth in phantom. Methods: Detector response in a 120kVp x-ray beam as a function of depth in a PMMA phantom was determined for a reference class Exradin A12 ionization chamber, an Exradin A1SL ionization chamber, TLD-100 and EBT3 radiochromic film and normalized to a depth of 1cm. The output of each detector was referenced to the A12 ionization chamber reading to assess changes in detector response as a function of depth. The BEAMnrc, DOSxyz, and egs-chamber user codes of the EGSnrc Monte Carlo code were used to calculate the dose delivered to the detectors from an x-ray source with similar beam quality to the one used in the measurements. Results: Changes in detector response relative to the A12 ionization chamber of 2%, 7%, and 14% for the A1SL, TLDs, and film, respectively, were observed with the larger changes in response occurring at larger depths. The Monte Carlo calculated changes in dose response showed less deviation, with the largest difference being within 2%. Conclusion: The Monte Carlo simulations show that doses delivered to the different detectors are quite similar, while measurements show that the detector output varies drastically. This indicates that the detector output per unit dose is changing with depth, most likely due to changes in the photon spectrum that occur because of scatter and attenuation of the primary beam. Because detector calibration is often performed at a single point in the kilovoltage energy range, the change in detector response needs to be considered when the measurement conditions differ from those of the calibration. This is of particular concern in computed tomography dose measurement, where calibrations are performed at shallow depths or in air, and measurements are made at deeper locations.

07 ISOTOPE AND RADIATION SOURCES↗

STRUCTURE OF THE ACCRETION FLOW IN BROAD-LINE RADIO GALAXIES: THE CASE OF 3C 390.3

We present XMM-Newton and Suzaku observations of the broad-line radio galaxy 3C 390.3 acquired in 2004 October and 2006 December, respectively. An archival Swift BAT spectrum from the 9 month survey is also analyzed, as well as an optical spectrum simultaneous to XMM-Newton. At soft X-rays, no absorption features are detected in the Reflection Grating Spectrometer spectrum of 3C 390.3; a narrow emission line is found at 0.564 keV, most likely originating in the narrow-line region. Both the EPIC and XIS data sets confirm the presence of an Fe K{alpha} emission line at 6.4 keV with equivalent width (EW) = 40 eV. The Fe K{alpha} line has a width FWHM {approx} 8800 km s{sup -1}, consistent within a factor of 2 with the width of the double-peaked H{alpha} line, suggesting an origin from the broad-line region. The data show for the first time a weak, broad bump extending from 5 to 7 keV. When fitted with a Gaussian, its centroid energy is 6.6 keV in the source's rest frame with FWHM of 43,000 km s{sup -1} and EW of 50 eV; its most likely interpretation is emission from He-like Fe (Fe XXV), suggesting the presence of an ionized medium in the inner regions of 3C 390.3. The broadband 0.5-100 keV continuum is well described by a single power law with photon index {gamma} = 1.6 and cutoff energy 157 keV, plus cold reflection with strength R = 0.5. In addition, ionized reflection is required to account for the 6.6 keV bump in the broadband continuum, yielding an ionization parameter {xi} {approx} 2700 erg cm s{sup -1}; the inner radius of the ionized reflector is constrained to be larger than 20r{sub G} , although this result depends on the assumed emissivity profile of the disk. If true, we argue that the lack of broad Fe K emission from within 20r{sub G} indicates that the innermost regions of the disk in 3C 390.3 are obscured and/or poorly illuminated. While the spectral energy distribution (SED) of 3C 390.3 is generally dominated by accretion-related continuum, during accretion low states the jet can significantly contribute in the optical to X-ray bands via synchrotron self-Compton emission. The Compton component is expected to extend to and peak at GeV gamma rays where it will be detected with the Fermi Gamma-Ray Space Telescope during its first few years of operation.

99 GENERAL AND MISCELLANEOUS↗

Characterization of the Hamamatsu R11780 12 in. photomultiplier tube

Future large water Cherenkov and scintillator detectors have been proposed for measurements of long baseline neutrino oscillations, proton decay, supernova and solar neutrinos. To ensure cost-effectiveness and optimize scientific reach, one of the critical requirements for such detectors are large-area, high performance photomultiplier tubes (PMTs). One candidate for such a device is the Hamamatsu R11780, a 12 in. PMT that is available in both standard and high quantum efficiency versions. Measurements of the single photoelectron response characteristics, relative efficiencies of the standard and high quantum efficiency versions, a preliminary measurement of the absolute quantum efficiency of the standard quantum efficiency version, and a two-dimensional scan of the relative efficiency across the photocathode surface are presented in this paper. All single photoelectron investigations were made using a Cherenkov light source at room temperature at a gain of 1×10 7 . These results show that the R11780 PMT is an excellent candidate for such large optical detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of High Quantum Efficiency UV/Blue Photocathode Epitaxial Semiconductor Heterostructures for Scintillation and Cherenkov Radiation Detection

The primary goal of this research project was to further extend the use of advanced heteroepitaxial-semiconductor crystal growth techniques such as molecular beam epitaxy (MBE) and to demonstrate significant gains in UV/blue photonic detection by designing and fabricating atomically-tailored heteroepitaxial GaAlN/GaInN photocathode device structures. This NASA Explorer technology research program has focused on the development of photocathodes for Cherenkov and scintillation radiation detection. Support from the program allowed us to enhance our MBE system to include a nitrogen plasma source and a magnetic bearing turbomolecular pump for delivery and removal of high purity atomic nitrogen during GaAlN/GaInN film growth. Under this program we have also designed, built and incorporated a cesium activation stage. In addition, a connected UHV chamber with photocathode transfer/positioner components as well as a hybrid phototube stage was designed and built to make in-situ quantum efficiency measurements without ever having to remove the photocathodes from UHV conditions. Thus we have constructed a system with the capability to couple atomically-tailored MBE-grown photocathode heterostructures with real high gain readout devices for single photon detection evaluation.

Leopold, Daniel J.↗

Femtosecond electronic response of atoms to ultra-intense x-rays.

An era of exploring the interactions of high-intensity, hard X-rays with matter has begun with the start-up of a hard-X-ray free-electron laser, the Linac Coherent Light Source (LCLS). Understanding how electrons in matter respond to ultra-intense X-ray radiation is essential for all applications. Here we reveal the nature of the electronic response in a free atom to unprecedented high-intensity, short-wavelength, high-fluence radiation (respectively 10{sup 18} W cm{sup -2}, 1.5-0.6 nm, {approx}10{sup 5} X-ray photons per {angstrom}{sup 2}). At this fluence, the neon target inevitably changes during the course of a single femtosecond-duration X-ray pulse - by sequentially ejecting electrons - to produce fully-stripped neon through absorption of six photons. Rapid photoejection of inner-shell electrons produces 'hollow' atoms and an intensity-induced X-ray transparency. Such transparency, due to the presence of inner-shell vacancies, can be induced in all atomic, molecular and condensed matter systems at high intensity. Quantitative comparison with theory allows us to extract LCLS fluence and pulse duration. Our successful modelling of X-ray/atom interactions using a straightforward rate equation approach augurs favourably for extension to complex systems.

43 PARTICLE ACCELERATORS↗

Prospects for experimental research on black holes in binary systems

Cygnus X-1, the single widely accepted example of a black hole in a binary system, is characterized by unusual X-ray properties. The X-ray spectrum of Cygnus X-1 is not cut off above 20 keV, as in most strong X-ray sources. Recent scintillation counter measurements reveal a power law spectrum extending from 40 to 200 keV with a photon spectral index of approximately 2.2. However, it is not clear that these and other X-ray properties of the system are related to the black-hole nature of Cygnus X-1. It is suggested that without a direct test to show that the mass of the compact object in other systems similar to Cygnus X-1 (Circinus X-1 and GX339-4) exceeds the limit of the neutron star mass, a better understanding of the accretion disk phenomenon must be achieved to demonstrate how the properties peculiar to these systems are related to the black hole nature of the compact object. Current accretion disk models are examined, including the alpha-accretion disk and two-temperature accretion disk models.

Long, K. S.↗