Report for 2.2.1 Task 3: Develop and Document an Advanced Human System Interface for the Generic Pressurized Water Reactor Simulator

The report explains the development of four new Operator Work Displays (OWDs). The work is performed for Idaho National Laboratory (INL) by the Institute for Energy Technology (IFE). The OWDs are implemented, and initially tested at the Generic Pressurized Water Reactor (gPWR) simulator in HAlden Man Machine LABoratory (HAMMLAB). The OWDs are designed to bridge the gap between large overview displays and detailed operator workstation displays. The report presents their design rationale, which stem from: human factors findings, industrial standards and guidelines and research into visual perception for computer displays. The report presents initial experiences using the OWDs, and topics for further work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model MC&A for Pebble Bed Reactors (Technical Direction No. 5 Task 2.6 Letter Report)

In preparation for non-light water reactor (non-LWR) activities, US Nuclear Regulatory Commission (NRC) staff are advancing risk-informed and performance-based licensing approaches and addressing key policy issues. One non-LWR reactor concept is a pebble bed reactor (PBR). This reactor design uses spherical fuel elements (pebbles) that are continually added to and removed from the reactor core. The free movement of the fuel in this design presents new challenges for material control and accounting (MC&A) programs. Therefore, an assessment of MC&A program features and measures for a PBR was performed to help NRC staff develop associated MC&A regulations or regulatory guides. The current regulatory framework for non-LWR fuel cycles excludes support for licensing reviews for MC&A programs for PBRs. Licensing reviews of an MC&A program for PBRs can be facilitated by (1) a model MC&A program for a PBR based on identification and assessment of MC&A program features and recommended measures for a reference PBR and (2) a methodology for assessing MC&A performance that can help assess different MC&A program features and measures. This report supports the NRC’s non-LWR Vision and Strategy Near-Term Implementation Action Plans.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Contra: A New Language for Task- and Data-Parallellism [Slides]

A new language is beneficial to take advantage of emerging architectures, and existing and new software technologies. Contra is a new language to provide performance portable code and consists of two innovations, which are described. A current status and illustrations of the code are shown.

97 MATHEMATICS AND COMPUTING↗

Aluminum Spent Fuel Performance in Dry Storage Task 4 Aluminum Oxide Sampling of ATR Dry Stored Fuel

Milestone report on sampling of long-term dry-stored ATR spent fuel elements. It describes tooling, sample acquisition methods and analysis of the aluminum oxide samples by scanning electron microscopy, thermogravimetric analysis, X-ray diffraction and transmission electron microscopy. The observations provide input to projections on controls necessary for maintaining the integrity of the fuel during extended interim storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IEA/HPT Annex 53 Advanced Cooling/Refrigeration Technologies Development – Task 1 Report

Air conditioning (AC) and refrigeration systems account for a large share of today’s global energy consumption, and this demand is expected to increase sharply over the next 50 years unless actions are taken to ameliorate the increase. The adoption of AC in developed countries increased rapidly in the twentieth century, and the twenty-first century is expected to see increased adoption in developing countries—especially those with hotter climates and large, growing populations, such as India, China, Brazil, and Middle Eastern and African nations. The International Energy Agency (IEA) projects that by 2050, AC energy consumption levels will increase by 4.3 times over the 2010 levels for non-Organization of Economic Coordination and Development (OECD) countries vs. only 1.5 times for OECD countries (Figure 1).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CO2 injection with fracturing in geomechanically protected caprock: Task 6 of LLNL's Research Activities to Support DOE's Carbon Storage Program (FWP-FEW0191) (Final Technical Report)

Conventional principles of the design and operation of geologic carbon storage (GCS) require injecting CO 2 below the caprock fracturing pressure to ensure the integrity of the storage complex. In non-ideal storage reservoirs with relatively low permeability, modest injection rates can lead to pressure buildup and hydraulic fracturing of the reservoir and caprock. While the GCS community has generally viewed hydraulic fractures as a key risk to storage integrity, the actual behavior of a caprock hydraulic fracture, particularly from a geomechanical perspective, has not been thoroughly studied. The prevailing method of treating a hydraulic fracture as a high-permeability wing of the storage reservoir might have resulted in erroneous understanding of caprock hydraulic fracture behavior. Comprehensive analyses of monitoring data from the In Salah project suggested that one or more hydraulic fractures may have been created in the reservoir and lower caprock system during injection operations, but did not cause detectable leakage of CO 2 out of the storage complex. This observation coincides with a well-known phenomenon in the oil and gas industry: sedimentary rock formations have many inherent features that naturally protect the formations from unbounded vertical growth of hydraulic fractures.

58 GEOSCIENCES↗

DECOVALEX2019 Task C: Results of Step 2 modeling

The work for Step 1 performed at Sandia National Laboratories and reported in Section 7 has been updated to incorporate new data and to conduct new simulations using a new larger base case domain. The new simulations also include statistical analysis for different fracture realizations. A sensitivity analysis was also conducted to the study of the effect of domain size. A much larger mesh was selected to minimize boundary effects. The DFN model was upscaled to the new base case domain and the much larger domain to generate relevant permeability and porosity fields for each case. The calculations updated for Step 2 are described in Section 12.1. New calculations have also been conducted to model the flooding of the CTD and the resulting pressure recovery. The modeling includes matching of pressure and chloride experimental data at the six observation locations in Well 12M133. The modeling was done for the 10 fracture realizations. The Step 2 recovery simulations are described in Section 12.2. The Step 2 work is summarized in Section 12.3.

42 ENGINEERING↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Report for 2.2.1 Task 5: Develop and Document a State-Based Alarm System for a Nuclear Power Plant Control Room Using Machine Learning

Idaho National Laboratory (INL) has contracted IFE to support human factors research and the development of leading-edge technology to support control room operators as the U.S. fleet undergoes modernization and digitalization in legacy plants and control rooms. As the nuclear industry starts to shift to more digital controls and systems, these upgrades provide more information to the main control room in the form of digital signals and values. Also, an increase in the number of alarms points is provided by the vendors. New digital control rooms shift from main control boards to soft controls, and alarm panels to a single display. This change to a single display has created a problem of alarm waterfall, a situation in which the addition of new alarm points causes an overload of information to the operator during either a plant disturbance or other than normal full power operations. IFE’s goal is to find a workable solution to assist operators in both handling and understanding incoming alarms during emergency situations under these waterfall conditions.

99 GENERAL AND MISCELLANEOUS↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 10: Controllability and Observability Analysis (Deliverable D7))

It is common to have less than full observability for distribution systems, as the number of available measurements are not sufficient. Considering increasing penetration of distributed energy resources (DERs), it is imperative to understand and control distribution systems better. Developed for the transmission system, the original numerical observability analysis methods were based on the canonical DC Power Flow (DC-PF) model. However, the DC-PF model is ill-suited for the distribution system in which line resistance to reactance (R/X) ratios can be near unity. In this report, we apply the non-iterative Observability Test (OT) and Observable Island Identification Procedure (OIIP) in to the gain matrix from the distribution system state estimator. Because sensors are few in distribution systems, pseudo-measurements based on historical load profiles and zero-injection virtual measurements are often employed to ensure observability. However, both the observability and the accuracy of the state estimates are uncertain when historical data is limited/unavailable.

42 ENGINEERING↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 11 & 12: Components and Capabilities of the Resiliency Driven Outage Management and Feeder Restoration System (Deliverable D8))

This report provides progress update for the development of a outage management, feeder restoration, and restoration action feasibility check modules as part of the AGGREGATE project. Details for integration with controllability module, data driven situational awareness of network and distributed energy resources as well cyber security plan for these modules integrated with GE ADMS are also presented in the report. These three modules for outage management, feeder restoration, and restoration action feasibility check modules are developed in MATLAB and validated with a modified IEEE 123-node feeder. Results demonstrate ability of these new modules to improve the restoration process post-disaster to enhance the system resilience.

42 ENGINEERING↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 13: Functional Specification Report(Deliverable D9))

This report provides functional specification for the AGGREGATE project and associated modules/ tools being developed for outage management and restoration with the Distributed Energy Resources (DERs). This report also provide initial validation of the developed modules and performance metrics. The AGGREGATE team at this stage has been collaborating with General Electric (GE) and Seattle City Light (SCL) to move forward from offline validation to online validation using commercial advanced distribution management system (ADMS). Hence, the functional specifications documents, which outline the requirement of various modules, is provided to address the integration of the modules, including 1) real-time model update and aggregation tools module, 2) observability and controllability metric module, 3) fault location solution service restoration module, 4) transmission-distribution co-simulation module, and 5) advanced distribution management system module. integration of different AGGREGATE modules and functional specification provides the foundation for online multi-scenario testing using SCL system model.

42 ENGINEERING↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 14: Model Verification/Validation Test Plan (Deliverable D10))

This report summarizes the technical progress and validation plan for each of AGGREGATE project modules, and integrated modules. The overall validation plan can be divided into two major parts. Firstly, it provides offline validation results of each module using the IEEE-123 node distribution system with certain modifications to support individual module results verification. The offline validation plan tentatively validated the usability and practicability of developed AGGREGATE tools. Secondly, the realworld test system - Seattle City Light (SCL) test feeder for verifying each module and the integrated modules using GE advanced distribution management system (ADMS) software.

42 ENGINEERING↗

Report for Task 15: Developed Tool Verification/Validation Report (Deliverable D11): AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency

This report summarizes the verification report for the developed modules. The team conducted verification in two phases. In phase 1, the modules were validated using offline validation methods and in phase 2 the modules were subjected to real-time validation. This report outlines the approach and the results for the modules under offline and real-time settings. The rest of the report details the functional workflow of AGGREGATE modules, we then transition to offline validation followed by real-time validation of modules. We conclude the report by discussing some of the key points of this report.

14 SOLAR ENERGY↗

Develop Safety Plan for Installation and Operation of the Observation Wells (SECARB Phase III Task 3.1.3a [Early] Project at Cranfield)

Sandia Technologies developed and deployed a worker health and safety plan for the CFU31_F2 and CFU 31F3 observation wells, covering the SECARB activities following drilling the wells to total depth. The purpose of this health and safety plan (HASP) is to assign responsibilities, establish personnel protection standards, specify safe operating procedures, and provide for contingencies that may arise during the Cranfield Phase III Monitor Well installation. This HASP has been developed in accordance with Sandia Technologies, LLC (Sandia) safety and health standard operating procedures. Specific programs and procedures, as required by site activities, are identified herein.

01 COAL, LIGNITE, AND PEAT↗

Washington Clean Energy Fund: Controller Development Project (Task 1.1 Preliminary Report Outlining Data Needs for Controller Development)

As a part of the Washington Clean Energy Fund, Avista Utilities has installed a UniEnergy Technologies vanadium redox-flow battery in Pullman, Washington to assess the value it could provide. PNNL is working with Avista to develop a controller for the battery that will maximize the value it provides. This controller will use forecasts for various electrical and financial parameters to define the optimal operating behavior of the battery. As a part of the controller development, PNNL is requesting certain data from Avista; this report outlines this data request.

25 ENERGY STORAGE↗

Task 15–NATCARB Atlas Update–CO 2 Sequestration Capacity Offshore Western Gulf of Mexico (SECARB CO 2 Capacity Assessment for Delineated Federal Waters)

The Gulf of Mexico Basin (GOM) is a world-class sedimentary wedge that offers huge potential for CO 2 sequestration. Our specific study area encompassed the western portions of the offshore Gulf of Mexico (GOM) that is under Federal jurisdiction (Bureau of Ocean Energy Management, Regulation and Enforcement “BOEMRE”; formerly MMS) and adjacent state waters of Louisiana and Mississippi. The study refined a previous assessment of the capacity of selected potential storage targets and inventoried existing infrastructure such as pipelines and wells.

01 COAL, LIGNITE, AND PEAT↗