Search NASA⌕ Search

SEARCH · Search NASA

Results for “throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Combined guaranteed throughput and best effort network-on-chip

A first packet-switched reservation request is received. Data associated with the first packet-switched reservation request is communicated through a first circuit-switched channel according to a best effort communication scheme. A second packet-switched reservation request is received. Data associated with the second packet-switched reservation request is communicated through a second circuit-switched channel according to a guaranteed throughput communication scheme.

97 MATHEMATICS AND COMPUTING↗

Pin base sensor for high-throughput macromolecular crystallography

Sensing methods and a compact, sample holding pin base sensor are provided for detecting if a sample pin is, for example, properly mounted on a goniometer used for automated, high throughput macromolecular crystallography. A first magnet is used for holding a magnetic base; a second magnet is disposed spaced apart from the first magnet. The first magnet and the second magnet have opposite orientation. A Hall-effect switch is located generally centrally between the first magnet and the second magnet. A state of the Hall-effect switch indicates if a sample pin is properly mounted on a mounting member, such as a goniometer.

Makarov, Oleg↗

A Custom High-Throughput Optical Mapping Instrument (OMI) for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom Optical Mapping Instrument (OMI) to improve measurement throughput time, facilitate automated measurements, and obtain spatial information relative to commercial benchtop spectrophotometer instruments. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. Example mapping measurements and their implications are given for specimens from other studies, including: (1) the depletion of the UV absorber is revealed for specimens beyond a certain size after standardized artificial ultraviolet (UV) weathering, (2) an optical degradation by internal haze formation is confirmed following Damp Heat (85°C/85% relative humidity) testing, (3) the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture, and (4) the local (millimeter-scale) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The Tracking Machine Learning challenge : Throughput phase

This paper reports on the second "Throughput" phase of the Tracking Machine Learning (TrackML) challenge on the Codalab platform. As in the first "Accuracy" phase, the participants had to solve a difficult experimental problem linked to tracking accurately the trajectory of particles as e.g. created at the Large Hadron Collider (LHC): given O($10^5$) points, the participants had to connect them into O($10^4$) individual groups that represent the particle trajectories which are approximated helical. While in the first phase only the accuracy mattered, the goal of this second phase was a compromise between the accuracy and the speed of inference. Both were measured on the Codalab platform where the participants had to upload their software. The best three participants had solutions with good accuracy and speed an order of magnitude faster than the state of the art when the challenge was designed. Although the core algorithms were less diverse than in the first phase, a diversity of techniques have been used and are described in this paper. The performance of the algorithms are analysed in depth and lessons derived.

Amrouche, Sabrina↗

Apparatus for high-throughput sequential tensile testing and methods thereof

The present invention relates, in part, to an apparatus configured to test a plurality of test samples within a sample cartridge. Such an apparatus can facilitate high-throughput tensile testing of such test samples. Also described herein are methods for using such an apparatus and for testing such test samples.

Boyce, Brad↗

New High-Throughput Measurement Systems for Radioactive Wastes Segregation and Free Release - 16166

The European Metrology Research Program (EMRP) is a coordinated research-and-development program that pursues the closer integration of national research programs. The EMRP Metrology for Decommissioning Nuclear Facilities 'MetroDecom' Joint Research Project ENV54 (JRP ENV54), a 36-month project started in September 2014, delivers research products addressing all aspects of the decommissioning process. This includes the characterization of waste materials present on the decommissioning site, pre-selection prior to free release or repository acceptance measurement, free-release measurement, the measurement of waste packages thermal power prior to the repository storage, and the monitoring of stored wastes and repositories in the very long term. This paper describes the track record of two JRP ENV54 working packages, which address the measurement facilities for pre-selection of waste materials prior to measurement for repository acceptance or possible free release (segregation measurement system); and free release (free release measurement system), based on a single standardized concept characterized by unique, patented lead-free shielding. The key objective is to improve the throughput, accuracy, reliability, modularity and mobility of segregation and free-release measurement. This will result in more reliable decision-making with regard to the safe release and disposal of radioactive wastes into the environment and, resulting in positive economic outcomes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗

High-Throughput Custom Monitoring for the Mu2e TDAQ System

In this project we are studying the application of programmable network hardware to provide a custom monitoring capability for the Mu2e Trigger and Data Acquisition System (TDAQ) system. The goal of the Mu2e experiment is to search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus. This experiment is intended to improve by four orders of magnitude the search sensitivity reached so far. We have a working prototype of a system that provides high-throughput, custom monitoring for the Mu2e TDAQ system. The custom Mu2e network packet header format is parsed as it crosses the network switch. Parsing extracts bits that convey information about error states at read-out controllers (ROCs). This information is periodically relayed to the switch controller, which in turn alerts experiment operators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Bayesian Integration Model of High-Throughput Proteomics and Metabolomics Data for Improved Early Detection of Microbial Infections

High-throughput (HTP) technologies offer the capability to evaluate the genome, proteome, and metabolome of organisms at a global scale. This opens up new opportunities to define complex signatures of disease that involve signals from multiple types of biomolecules. Integrating these data types however is difficult due to the heterogeneity of the data. We present a Bayesian approach to integration that uses posterior probabilities to assign class memberships to samples using individual and multiple data sources; these probabilities are based on lower level likelihood functions derived from standard statistical learning algorithms. We demonstrate this approach on microbial infections of mice, where the bronchial alveolar lavage fluid was analyzed by two HTP proteomic and one HTP metabolomic technologies. We demonstrate that integration of the three datasets improves classification accuracy to ~89% from the best individual dataset at ~83%. In addition, we present a new visualization tool called Visual Integration for Bayesian Evaluation (VIBE) that allows the user to observe classification accuracies at the class level and evaluate classification accuracies on any subset of available data types based on the posterior probability models defined for the individual and integrated data.

59 BASIC BIOLOGICAL SCIENCES↗

A High-Throughput Study of PtNiZr Catalysts for Application in PEM Fuel Cells

The effects of adding Zr to PtNi oxygen reduction reaction (ORR) electrocatalyst alloys were examined in a study aimed at probing the possibility of creating catalysts with enhanced resistance to corrosion in a PEM fuel cell environment. Samples consisting of pure Pt or PtNiZr alloys with a range of compositions (not exceeding 11 at.% Zr) were fabricated using co-sputter deposition. A high-throughput fabrication approach was used wherein 18 distinct thin film catalyst alloy samples with varying compositions were deposited onto a large-area substrate with individual Au current collector structures. A multi-channel pseudo-potentiostat allowed for the simultaneous quantitative study of catalytic activity for all 18 electrodes in a single test bath, a first for the study of ORR electrocatalysts. A properly stirred oxygenated 1 M H{sub 2}SO{sub 4} electrolyte solution was used to provide each electrode with a steady-state flow of reactants during electrochemical evaluation. The onset potentials, absolute current density values, and Tafel analysis data obtained using this technique were compared with literature reports. The analyses showed that most PtNiZr alloys tested offered improvements over pure Pt, however those surfaces with a high mole fraction (>4 at.%) of Zr exhibited reduced activity that was roughly inversely correlated to the amount of Zr present. Film composition, morphology, and crystallographic properties were examined using X-ray energy dispersive spectroscopy (XEDS), X-ray photoelectron spectroscopy (XPS), SEM, and synchrotron X-ray diffraction. These data were then correlated with electrochemical data to elucidate the relationships between composition, structure, and relative performance for this ternary system.

30 DIRECT ENERGY CONVERSION↗

High-Throughput Analysis of Serum Antigens Using Sandwich ELISAs on Microarrays

Enzyme-linked immunosorbent assay (ELISA) microarrays promise to be a powerful tool for the detection and validation of disease biomarkers. ELISA microarrays are capable of simultaneous detection of many proteins using a small sample volume. Although there are many potential pitfalls to the use of ELISA microarrays, these can be avoided by careful planning of experiments. In this chapter we describe a high-throughput protocol for processing ELISA microarrays that will result in reliable and reproducible data.

59 BASIC BIOLOGICAL SCIENCES↗

High throughput protein production screening

Methods, compositions, and kits for the cell-free production and analysis of proteins are provided. The invention allows for the production of proteins from prokaryotic sequences or eukaryotic sequences, including human cDNAs using PCR and IVT methods and detecting the proteins through fluorescence or immunoblot techniques. This invention can be used to identify optimized PCR and WT conditions, codon usages and mutations. The methods are readily automated and can be used for high throughput analysis of protein expression levels, interactions, and functional states.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of gene expression patterns using high-throughput RNA in situ hybridizaion to whole-mount Drosophila embryos

We describe a high-throughput protocol for RNA in situ hybridization (ISH) to Drosophila embryos in a 96-well format. cDNA or genomic DNA templates are amplified by PCR and then digoxigenin-labeled ribonucleotides are incorporated into antisense RNA probes by in vitro transcription. The quality of each probe is evaluated before ISH using a RNA probe quantification (dot blot) assay. RNA probes are hybridized to fixed, mixed-staged Drosophila embryos in 96-well plates. The resulting stained embryos can be examined and photographed immediately or stored at 4oC for later analysis. Starting with fixed, staged embryos, the protocol takes 6 d from probe template production through hybridization. Preparation of fixed embryos requires a minimum of 2 weeks to collect embryos representing all stages. The method has been used to determine the expression patterns of over 6,000 genes throughout embryogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

High-throughput Accurate-wavelength Lens-based Visible Spectrometera

A scanning visible spectrometer has been prototyped to complement fixed-wavelength transmission grating spectrometers for charge exchange recombination spectroscopy. Fast f/1.8 200 mm commercial lenses are used with a large 2160 mm-1 grating for high throughput. A stepping-motor controlled sine drive positions the grating, which is mounted on a precision rotary table. A high-resolution optical encoder on the grating stage allows the grating angle to be measured with an absolute accuracy of 0.075 arcsec, corresponding to a wavelength error ≤ 0.005 Å. At this precision, changes in grating groove density due to thermal expansion and variations in the refractive index of air are important. An automated calibration procedure determines all relevant spectrometer parameters to high accuracy. Changes in bulk grating temperature, atmospheric temperature and pressure are monitored between the time of calibration and the time of measurement to insure a persistent wavelength calibration

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Revisit the VEC rule in high entropy alloys (HEAs) with high-throughput CALPHAD approach and its applications for material design-A case study with Al–Co–Cr–Fe–Ni system

Valence electron concentration (VEC) was treated as a useful parameter to predict solid solution phases, and the VEC rule was proposed for high entropy alloys (HEAs). However, this empirical rule has its limitations, which restricts its applications for phase predictions in HEAs. In this paper, we revisited the empirical VEC rule with the HT-CALPHAD approach in the Al–Co–Cr–Fe–Ni system. Our investigation showed that more than 90% compositions are observed to have BCC structures when 5.7≤VEC≤7.2 and we got 100% FCC structures when VEC≥8.4. Meanwhile, we proposed a data screening procedure to classify and discover the new HEAs. The concepts of average density (ρHEA), highest BCC/FCC temperatures ($T$ $^{max}_{BCC/FCC}$), and temperature ranges (ΔT BCC/FCC ) were introduced as useful data screening criteria to down-screen the candidate alloy compositions for specific engineering applications. In the current work, we have identified three HEA categories (refractory BCC HEAs, light-weight BCC HEA and refractory FCC HEAs) in the Al–Co–Cr–Fe–Ni system and proposed the best candidate in each group. Here, our investigation showed the HEA non-equiatomic composition space provides ample opportunities for the discovery of the next-generation HEAs.

36 MATERIALS SCIENCE↗