A program to develop a high-energy density primary battery with a minimum of 200 watt hours per pound of total battery weight Seventh quarterly report, Jan. 1 - Mar. 31, 1966
Cathodic materials for high energy density storage battery
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Cathodic materials for high energy density storage battery
Solute-intercalation-induced phase separation creates spatial heterogeneities in host materials, a phenomenon ubiquitous in batteries, hydrogen storage, and other energy devices. Despite many efforts, probing intercalation processes at the atomic scale has been a significant challenge. By utilizing liquid-phase transmission electron microscopy (TEM), we study hydrogen (de)intercalation in palladium nanocrystals as a model system and have achieved unprecedented atomic-resolution imaging of hydrogen intercalation wave dynamics. Our observations reveal that intercalation wave mechanisms, instead of shrinking-core mechanisms, prevail at ambient temperature for palladium nanocubes ranging from ∼60 nm down to ∼10 nm. Systematic image analysis uncovers the atomic evolution of the hydrogen intercalation wave, transitioning from nonplanar and inclined boundaries to those closely aligned with {100} planes. Our kinetic Monte Carlo simulations demonstrate that the observed intercalation wave dynamics correspond to sorption pathways minimizing the lattice mismatch strain at the phase boundary. In conclusion, unveiling the atomic intercalation pathways holds profound implications for engineering intercalation-mediated devices and advancements in energy sciences.
Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS 181 Attitudes and Practices Regarding Disposal of Liquid Nuclear Waste at Clinton Laboratories in the Very Early Years: A Historical Analysis, S. H. Stow; 202 Off-Site Nuclear Emergency Management in Germany Under the Auspices of the Federal Structure, A. Bayer, S. Bittner, and H. Korn; DESIGN FEATURES: 211 Twenty-Fourth DOE/NRC Nuclear Air-Cleaning and Treatment Conference, R. R. Bellamy, J. J. Hayes, R. D. Porco, and M. W. First; OPERATING EXPERIENCES: 222 Explosion in the Tomsk-7 Reprocessing Plant on April 6, 1993, M. L. Hyder, W. G. Lussie, and F. E. Witmer; 234 Reactor Shutdown Experience, Compiled by J. W. Cletcher; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 237 Assessment of Spent Fuel Cooling, J. G. Ibarra, W. R. Jones, G. F. Lanik, H. L. Ornstein, and S. V. Pullani; RECENT DEVELOPMENTS: 256 Reports, Standards, and Safety Guides, D. S. Queener; 260 Proposed Rule Changes as of June 30, 1996; ANNOUNCEMENTS: 210 Tennessee Industries Week; 221 21st International Symposium on The Scientific Basis for Nuclear Waste Management; 259 IAEA Programme of Scientific Meetings for 1997; 270 PSAM 4 (International Conference on Probabilistic Safety Assessment and Management); 265 The Authors; 268 Errata.
Evaluation of various anode-electrolyte and cathode-electrolyte combinations for high energy density battery
A series of experiments designed to study the nuclear cascade resulting from the passage of 1 to 3 GeV protons in matter has been in progress at the Brookhaven Cosmotron. Preliminary results on the fluxes of fast neutrons (upper limits) and of strongly interacting particles above 50 MeV are summarized here (Fig. 1 and Table 1). The four cases studied are: 1-GeV protons on Fe, on chondritic material, and on C 5 H 8 O 2 , and 3-GeV protons on Fe.
Mechanical forces can enhance the chemical depolymerization of synthetic polymers when shear flow accelerates chain scission. To quantify the extent of mechanically-accelerated scission, the effect of simple shear flow (duration and strength) with low Weissenberg and Deborah numbers was investigated by considering the impact of applied work in both simple shear and shear dominated mixed flows. Hydrogenated polyisoprene was chosen as a model linear, entangled system. The conditions (strain amplitude, frequency, and shearing time) necessary to increase chain scission were assessed in the rubbery melt. Shear flow accelerated chain scission at higher temperatures, suggesting an activated process. Isothermal scission versus work curves were superposed by applying shift factors a T,S , whose Arrhenius-like temperature dependence gave an apparent activation energy for chain scission of ~ 110 kJ/mol, which is likely a combination of the activation energy of viscosity and bond energy. This work provides a base for quantifying the impact of shear on depolymerization of polymer melts and highlight the connection between viscous dissipation and scission chemistry.
The Earth Radiation Budget Satellite (ERBS), Compton Gamma Ray Observatory (CGRO), Upper Atmosphere Research Satellite (UARS), and Extreme Ultraviolet Explorer (EUVE) spacecraft are operated from NASA's Goddard Space Flight Center (GSFC) in Greenbelt, Maryland. On-board power subsystems for each satellite employ NASA Standard 50 Ampere-hour (Ah) nickel-cadmium batteries in a parallel configuration. To date, these batteries have exhibited degradation over periods from several months (anomalous behavior, UARS and CGRO (MPS-1); to little if any, EUVE) to several years (old age, normal behavior, ERBS). Since the onset of degraded performance, each mission's Flight Operations Team (FOT), under the direction of their cognizant GSFC Project Personnel and Space Power Application Branch's Engineers has closely monitored the battery performance and implemented several charge control schemes in an effort to extend battery life. Various software and hardware solutions have been developed to minimize battery overcharge. Each of the four sections of this paper covers a brief overview of each mission's operational battery management and its associated spacecraft battery performance. Also included are new operational procedures developed on-orbit that may be of special interest to future mission definition and development.
Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Highly conductive nonaqueous electrolytes for high energy battery
Validated integrated modelling of JET ITER-like wall experiments in which fusion performance is driven by reactions between fast ions and intrinsically present metal wall impurities is presented. A steady-state L-mode plasma with dominant proton-beryllium fusion and neutron yields of up to ≈ 6·10 13 s -1 is developed in He and D, via radiofrequency heating of a H minority. The fusion drive is unambiguously confirmed by the neutral particle analyser, fast ion loss detector, and γ-ray diagnostics. Experiments are analysed via an integrated modelling framework, developed to model the two-stage proton beryllium-fusion chain and produce high-fidelity fusion product source terms. The modelling chain comprises TRANSP and JETTO for plasma core modelling, LOCUST for full orbit product tracking and collisional slowing-down, DRESS to resolve two- and three-body fusion kinematics, and MCNP for neutron transport calculations. Modelling shows that the primary 9 Be(p,n) 9 B reaction is the dominant neutron emitter at naturally present concentrations of beryllium in these experiments. The yield contribution of secondary reactions between fusion products and beryllium, 9 Be(d,n) 10 B and 9 Be(α,n) 12 C, is found to be negligible. The proton-deuteron knock-on effect in D plasmas is modelled, which is calculated to contribute ≈ 25% to the total neutron yield. For both He and D discharges the total computed neutron rates match fission chamber (FC) measurements within the combined experimental and computational uncertainty, with an average discrepancy of ≈ ± 20%. Realistic proton-beryllium neutron sources are propagated through JET’s MCNP neutron transport model which shows that 235 U FCs’ response is sensitive to p–Be source changes, with up to ≈ 10% variation compared to a D–D neutron source. We show that the high-energy tail of the fast proton minority can be studied with multi-foil neutron activation. The framework is also applied to the study of interactions between fast protons and boron impurities, of relevance to ITER. We calculate that in JET conditions a significant alpha source with DT-like energies could be generated through 11 B(p, α)2α fusion, and detected via γ-emission in secondary interactions between fast alphas and boron. The work represents an important step towards validating predictive integrated modelling capabilities for non-standard fusion reactions.
Explore the source record for details and available documents.
The superconducting gap defines the fundamental energy scale for the emergence of dissipationless transport and collective phenomena in a superconductor. In layered high-temperature cuprate superconductors, in which the Cooper pairs are confined to weakly coupled two-dimensional (2D) copper–oxygen (CuO 2 ) planes, terahertz (THz) spectroscopy at subgap millielectronvolt (meV) energies has provided crucial insights into the collective superfluid response perpendicular to the superconducting layers. However, within the CuO 2 planes, the collective superfluid response manifests as plasmonic charge oscillations at energies far exceeding the superconducting gap, obscured by strong dissipation. Here, in this study, we present spectroscopic evidence of a below-gap, 2D superfluid plasmon in few-layer Bi 2 Sr 2 CaCu 2 O 8+x and spatially resolve its deeply subdiffractive THz electrodynamics. By placing the superconductor in the near field of a spintronic THz emitter, we reveal this distinct resonance—absent in bulk samples and observed only in the superconducting phase—and determine its plasmonic nature by mapping the geometric anisotropy and dispersion. Crucially, these measurements offer a direct view of the momentum-dependent and frequency-dependent superconducting transition in two dimensions.
Deploying advanced building control strategies in small- and medium-sized commercial buildings (SMBs) is critical but constrained by two major challenges: (1) the lack of sensor and control infrastructure (SCI) and (2) the significant engineering effort required for implementation and configuration. While these barriers limit large-scale adoption in SMBs, they remain underexplored in the literature, which has largely emphasized feasibility over scalability.
Addition of fixed resistor between battery and clocked complementary metal oxide/semiconductor (CMOS) circuit reduces current drawn from battery. Basic idea to minimize current drawn from battery by operating CMOS circuit at lowest possible current consistent with use of simple, fixed off-the-shelf components. Prolongs lives of batteries in such low-power CMOS circuits as watches and calculators.
Solid-polymer electrolytes comprised of polypropylene carbonate (PPC) and varied sodium bis(fluorosulfonyl)imide (NaFSI) salt concentrations are investigated for implementation as a conductive solid polymer electrolyte into solid-state cathode composites utilizing a sodium-layered oxide active material. The ionic conductivity generally increases with NaFSI salt content, reaching ≈1 mS cm −1 at 80 °C at the highest salt concentration (PPC:NaFSI = 0.5:1). Through an all-in-one slurry casting method, Na 2/3 Ni 1/3 Mn 2/3 O 2 cathode composites are fabricated in which the dispersed PPC electrolyte acts as the primary binder. Enabled by a bilayer polymer electrolyte system, cycling performance with the PPC cathode electrolyte is optimized with respect to salt concentration and anode material. The best cyclability is achieved with a moderate salt concentration electrolyte (PPC:NaFSI = 5:1), showcasing an initial capacity of 83 mA h g −1 with a remarkable 80% capacity retention after 150 cycles at C/5 rate and 60 °C. The superior performance of the lower salt concentration electrolyte is attributed to better electrochemical stability, as confirmed by linear sweep voltammetry and online electrochemical mass spectrometry measurements. In conclusion, these results underscore the potential of carbonate-based polymer electrolytes and the importance of balancing electrolyte conductivity and stability in cell design.